Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹40.5 LAccepted-AOC | ₹40.5 L Quoted ₹42.9 L | L1 | Accepted-AOC Eligible |
| 2 | L2₹45.6 L+₹2.6 L (6.08%)Rejected-AOC RCP GURUDWARA ROAD WARD NO 29 SURATGARH SRI GANGANAGAR 335804 | SURATGARH | SRI GANGANAGAR | RAJASTHAN | 335804 | ₹45.6 L+₹2.6 L (6.08%) | L2 | Rejected-AOC Not Eligible |
Tender Value
₹39.6 L
EMD Value
₹79,240
Closing Date
7 Apr 2025, 6:00 pmClosed
CWE AF BIKANER
HQ CWE AF BIKANER
REPAIR/MAINT OF HT UG CABLE, TRANSFORMERS, VCBS, CAPACITOR PANELS AND CONNECTED E/M WKS AT AF STN SURATGARH
2025_MES_699391_1
81599/E8
Open Tender
Civil Works
Item Rate
90 days
GE AF SURATGARH
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE AF SURATGARH
₹79,240
Yes
29 May 2025
25 Feb 2025
9 Apr 2025
25 Feb 2025
7 Apr 2025
24 Mar 2025
Amount
Dismantling and removing and setting aside for credit to contractor PCC poles any type/size by breaking PCC foundation after disconnecting electrical connection incl site clearance complete all as specified and directed by Engr-in- Charge.
Dismantling and removing and setting aside for credit to contractor steel tubular pole any type/size by breaking PCC foundation after disconnecting electrical connection incl site clearance and depositing to AGE E/M store yard complete all as specified and directed by Engr-in- Charge.
Supply and fixing in replacement steel tubular swaged poles complete with cast iron base plate, finial taper plug, bolts, nuts & screws as specified type 410 SP-55 (11.0 metres long) including one coat primer and two coat aluminium paint all as specified and directed by Engr-in-Charge
M&L in replacement cross arms, bracings, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers welding, bending cold or hot drilling holes for bolts, in any shape or size as indicated or directed and inclusive of one primer coat and one finishing coat of paint all as directed by Engr-in-Charge.
Dismantling taking out carefully old/unserviceable UG cable any type any size from trenches/poles/ducts/ HT panels after dismentling ends from OH conductors/MCCBs/joint boxes for relaying/refixing or carrying to store for Sch of Credit.
Supply, laying, connecting and testing in replacement XLPE insulated, screened, PVC bedded galvanised steel strip or wire armoured electric power cable (heavy duty) with stranded aluminium conductor for 11 KV working voltage cross sectional area 3 core, 95 sqmm complete.
All as per item No 6.00 above but of size 3 core 120 sqmm
All as per item No 6.00 above but of size 3 core 150 sqmm
All as per item No 6.00 above but of size 3 core 300 sqmm
Supply, laying and testing in repair XLPE insulated screened PVC bedded, galvanised steel strip/ wire armoured, electric power cables (Heavy Duty) with stranded Aluminium conductor, 33 KV grade of size 3 core 300 Sqmm complete all as specified and directed including taking down old unsv cable.
Labour only for relaying cable in trenches passing through pipe or fixed to pole at existing places or carrying to other location, upto 11KV/33KV grade heavy duty cable size upto 300 sqmm 3 core obtained from item No-05 here-in-before with required aluminium cable lugs all as specified and directed.
Supply and fixing in replacement cable jointing kit for 11 KV (earthed) grade cable for indoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 95 sqmm
All as per item No 12.00 above but joint of size120 to 185 sqmm
All as per item No 12.00 above bu joint of size 240 to 300 sqmm
Supply and fixing in replacement cable jointing kit for 11 KV (earthed) grade cable for outdoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 95 sqmm
All as per item No 15.00 above but joint of size 120 to 185 sqmm
All as per item No 15.00 above but joint of size 240 to 300 sqmm
Supply and fixing in replacement cable jointing kit for 11 KV (earthed) grade cable for straight through heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 95 sqmm
All as per item No 18.00 above but straight through joint of size 120 to 185 sqmm
All as per item No 18.00 above but straight through joint of size 240 to 300 sqmm
Supply and fixing in replacement cable end termination, outdoor, heat shrinkable type joint complete with jointing material and accessories suitable for 33 KV, 3 core 300 sqmm, XLPE armoured aluminium conductor cable complete all as specified and directed.
All as per item No 21.00 above but indoor type joint
All as per item No 21.00 above but straight through joint
Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out Soft /Loose Soil.
Excavating in trenches, n.exc 1.5 m wide but n.exc 3 m in depth; for foundation, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out in hard/dense soil complete.
Returning filling in including spreading levelling watering and well ramming in n.exc. 25 Cum complete all as directed by Engr-in-Charge.
Removing the excavated material ( soil ) n.exc. 50m and depositing where directed at a level n.exc. 1.5m above the starting point all as directed by Engr-in-charge.
Supply & spread sand for cushioning of cables laid in trenches all as specified in SSR Part -I and directed by Engr-in-Charge. Note:- Punned thickness shall be measured
Supply and laying unreinforced precast concrete cable cover, class HV, Type I flat of size 300mm x 180mm x40mm all as directed by Engr-in-Charge
Supply and fixing in replacement GI tubing light grade with all fittings for protection of cable laid in tranches or fixing to pole , wall with suitable size of FI clamp complete of following sizes:-
a) 100 mm dia bore
b) 80 mm dia bore
Supply and fixing in replacement pin type, porcelain, vitreous, white brown or green insulator including one galvanised mild steel spindle, two galvanised iron washers and one galvanised iron nut, 150mm height, 150mm dia for 11000 volts grade incl taking down old/unsv all as specified and directed.
Supply and fixing in replacement disc type, porcelain vitreous 145 mm high and 255 mm dia ball and socket type white, brown or green insulator single disc assembly for conductors working pressure 11 KV grade incl taking down old/unsvall as directed by Engr-in-Charge.
S&F in replacement disc Type, Porcelain, vitreous, white, brown green insulator including galvanised mild steel straps, washers, insulator bolts, washers and nuts for 33 KV complete incl taking down old/unsvall as specified and directed.
Supply and fixing in replacement pin type, porcelain, vitreous, white, brown or green insulator including one galvanised mild steel spindle, two galvanised iron washers and one galvanised iron nut, for 33KV grade complete incl taking down old/unsv all as specified and directed.
Supply and fixing in replacement gang operated air Brake switch triple pole mechanically operated mounted on insulator & steel frame with operating mechanisam worked from ground level suitable for11 KV for current rating upto 400 Amp of approved make with and including operating rod, GI tubing 25mm dia medium grade single piece of suitable length and insulated handle complete incl taking down old/unsv all as specified. . Note : AB switch shall consist of three insulators per phase and 12 isolators in all.
All as per item No 35.00 but 33 KV 400 Amp, operating horizontal direction incl taking down old/unsvall as specified and directed
Supply and fixing in replacement HT 33 KV outdoor type dropout fuses double stack channel type complete with insulator of rating up to 400 Amps incl taking down old/unsvcomplete all as specified and directed.
Material and labour for bituminous road cutting to a width of 60cm and depth 90cm for laying of HT cable and making surface good with PCC (1:3:6) type B1(using 20mm grade stone aggregate) thickness upto 40 mm
Material and labour for scrapping of old painted surfaces of electric pole covered by dust and other deposited materials by cleaning from steel tubular pole of length upto 11 metres including cross arms, bracing, clamps etc and painting with one coat of aluminium paint, retaining & repainting marking on pole & replacement of reflective band of width 4 cm RED-YELLOW-RED alternate coloured 3 numbers all as specified & directed by Engr-in-Charge.
Material and labour for scrapping existing deteriorated old aluminium paint by hard wire brush painting the existing 2 pole structure by aluminium paint including cross arms, support angles, clamps and any other structural part complete all as directed by Engr-in-Charge
All as per Ser item No. 40.00 herein above but for 4 pole structure.
All as per Ser item No.40.00 herein above but for 6 pole structure.
Material and labour for fault detection in damaged HT/LT UG cable by using cable fault detector/locator vehicle mounted comprising of surge generator pulse, ECHO fault locator with high frequency distance calculator etc to accuracy of 2 meter for various location inside AF Stn for UG cables of any size any type upto 33 KV incl excavation & Earthwork in any type of stratra to usually inspect/repair the damaged cable when and where required all as directed by Engr-in-Charge. Note : (i) Compaint will be notified to contractor on mobile phone at any time and contractor is responsible to rectify the fault within 4 hrs after notification, failing which Rs. 500/- per hrs shall be recovered from contractors dues. (ii) Rates included necessary earth work in any type of strata or road for opening the cable and prepare the cable ready to jointing work and making good to match with existing finishes.
Material and labour for Loose filling with aggregates of broken stone gauge 40 to 80 mm in HT substation yard complete including removal of any debris etc all as specified and as directed
Material and labour earth continuity conductor or main earthing lead of size 32x6mm galvanised iron strip fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to ples or any other indicated situation for loop earthing etc incl taking down old/unsv all as directed.
Supply and fixing earth continuity conductor or main earthing lead of size 20x3 mm copper strip fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to ples or any other indicated situation for loop earthing etc incl taking down old/unsv all as directed.
Cutting of tree branches of any girth along HT OH lines at a distance not less than 2 meter on either side of the pole cleaning of bushes and shrubes of any type along entire RM of pole. Cleaning /prunning should be carried out as and when required during entire running period of contract or as when directed by E-I-C. A fine of one time quoted rate per running metre will be deducted if the over groth is found along the pole all as directed by Engr-in- Charge.
Cutting of tree branches/grass at MRS /sub station compound and cleaning & removal of all the wasted materials at far distance from 4 pole/ two pole structure/sub stn, cleaning of ducts including leveling of undulated land complete all as specified and directed by Engr -in-Charge.
Cleaning of surrounding area of 2 pole/4 pole structure inside fencing by cutting of tree branches/grass , removal of all the wasted materials at far distance from 4 pole/ two pole structure/including leveling of undulated land complete all as specified and directed by Engr -in-Charge.
Demolition of cement concrete unreinforced of any description and in any position not otherwise specially provided for all as directed by Engr-in-Charge
Material and labour for PCC 1:3:6 type C2 using 40 mm graded stone aggregate for mass filling of poles etc complete all as specified & directed.
Material and labour for PCC 1:2:4 type B1 using 20mm graded stone aggregateas for coping including necessary form work all as directed by Engr-in-Charge
Stringing/Tension adjustment for the Sag of Overhead HT Line 3 wire including guard wire to the required tension complete all as directed by Engr-in-Charge for the following :-
Set of three conductor
Guard wire with Cradle
Disconnecting of all HT cable, opening of RMU of any make, rating 11 KV 400/800 Amps capacity and servicing / overhauling, taking out and removing unserviceable / defective parts including cleaning & servicing, greasing, oiling of the parts etc and replacement of unserviceable parts with new one, if required, reassembling and testing RMU ,reconnecting all cables complete all a specified and directed.
Supply and fixing in replacement glow sign board box type printed on poly carbonated sheet of size 300 x 100 x 25 cm having provision of 3 x LED tube light inside the box and 10 mtrs 3 core 1.5 sqmm circular PVC connecting wire with hanging arrangment incl taking down old/unsv all as directed by engr -in charge. Note :- Background, font size & colour and material to be printed on board shall be as per direction of Engr-in-Charge.
Supply and fixing shock treatment chart duly printed with hindi & english, fitted with woden card board of size 100 CM x60CM with hanging arrengment for installations incl taking down old/unsv all as directed by Engr-in charge
All as per item no 56.00 above but chart prevention from fire.
Material and labour chequered plate of size 4 mm thick laid over cable ducts as duct cover..
Material and labour in replacement of jumper connection not less than 1.5 Mtr long between bus system to GOD and GOD to DO fuse unit with jumper made of 11/33 KV aluminum conductor (11/33 KV) including clamps, crimple, PVC slveeeves inclding taking down burnt out jumpers complete all as specifid and directed.
Supply & fixing lightning arrestors expulsion type complete with all fittings, suitable for 11 KV grade transmission class, discharge capacity 65KA including brackets, clamps, nuts washers and connecting to 4 mm dia GI earth wire including taking out old unservicable lightining arrester all complete all as specified and directed.
Supply & fixing lightning arrestors expulsion type complete with all fittings, suitable for 33 KV grade transmission class, discharge capacity 65KA including brackets, clamps, nuts washers and connecting to 4 mm dia GI earth wire including taking out old unservicable lightining arrester all complete all as specified and directed.
Supply and fixing cable route indicator for HT UG cable of 11000 Volts bolted with 40x6mm flat iron member of height 0.60m and 80mm dia CI plate, embeded in PCC 1:3:6 type C-2 of size 20cm x20cm x30cm block complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing ACSR conductor of any type/size on existing poles including fixing to insulators with binding wire or aluminium taps complete all as directed .
Dismantling and taking down by removing HT and LT connection of indoor/outdoor type 11/0.433KV transformer capacity 100 KVA to 630KVA from existing plateform / 4 Pole / 2 Pole structure, lowering the same carefully and shifting to other location within Air Force Station as directed by Engineer-in-Charge with and including reinstallation by any means of arrangement and testing complete all as specified and directed.
Supply and fixing marshaling box complete with all sensor for protection of winding temprature , oil temprature etc suitable for 5 MVA/3MVA Transformer or as per existing incl connection and taking down unsv all as specified and directed.
Supply and fixing Aux contactor suitable for 5 MVA AVR Unit incl taking down old/unsv all as specified and directed
Material and labour for filteration and dehydration of transformer oil by dehydration machine to achieve the die-electric strength/ insulation value upto 65 KV/40KV (RMS) at standard gap of electrodes 2.5 mm for one minute in 33 KV/11 KV transformer capacity 3 MVA TO 5 MVA including insulation testing of oil with help of suitable equipments before and after dehydration including BDV Test compete all as specified and directed. Note: (i) Contractor will have to arrange the dehydration machine and transformer oil dielectric strength testing equipment as mentioned and same shall be deemed to be included in the item rate quoted. (ii) Test result of transformer oil before and after dehydartion is required to submit by contractor duly signed by all concerned. (iii) The contractor shall ensure that the conservator tanks are full to its level before commencement of dehydration process. (iv) Additional quantity of transformer oil if any required for making the oil level upto the requirement in transformer shall be measured and paid separately as supply and filling but its cost of heating shall be deemed to be included in the rate quoted for above item.
Supply and filling transformer power oil meeting IEC 60296-2003-11, 3rd edition standard specification and ASTMD 1275B test requirements for corrosive sulpher of BDV not be less than 70 KV at 2.5mm gap for reduced level of transformer due to evaporation/ leakage/losses due to dehydration in HT 33 KV transformer/HT 11 KV AVR transformer/11 KV distribution transformer all as as specified and directed.
Supply and replacing of silica gel crystel filled in the breather of any capacity of transformer complete all as directed.
Disconnecting, opening of VCB of any description and any make of rating 11 KV 400/800 Amps capacity for servicing / overhauling, taking out and removing unserviceable / defective parts including cleaning & servicing, greasing, oiling of the parts etc and replacement of unserviceable parts with new one, reassembling the VCB after overhauling/ servicing and its testing complete all a specified and directed. Note: (i) Replacement of unserviceable parts shall be measured and paid for separately under appropriate item of Sch 'A' as supply only but fixing charges of the parts replaced /repaired is deemed to be included in this item. (ii) Servicing shall be got carried out by the authorised rep of the VCB manufacturer and the service engineer will submit a service report for each VCB. (iii) Any item not included in CA and required for successful operation of the panel will be provided by the contractor & same shall deemed to be included rate quoted.
Supply only following items/spare parts suitable for 11KV VCB, 400/800 Amps capacity of dismantled / fixed under Sch 'A' item No: 70 here-in-before complete all as specified and directed.
Vaccum Interrupter type WL-33379 or as per exixting suitable for 11 KV VCB Panel complete all as specefied and directed.
Isolating contact assembly 400/800 Amps with complete set of contact (set of six) suitable for 11 KV VCB Panel complete all as specefied and directed.
Tripping Coil assembly 30 Volts DC suitable for 11 KV VCB Panel complete all as specefied and directed.
Close Coil assembly 30 Volts DC suitable for 11 KV VCB Panel complete all as specefied and directed.
Motor & Gear assembly 110V DC and 220 AC for 11 KV VCB Panel complete all as specefied and directed.
TNC switch for 11 KV VCB Panel complete all as specefied and directed.
Indication lamp LED type suitable for 230 Volts AC 50Hz and 110/30 Volts DC supply.
Micro processor base relay (02 O/C + 01 EF) for 11 KV VCB panel , rating 5 Amps, Auxiliary supply 24-110 Volt DC
Cast resin type 11KV VCB three phase current transformer having ratio 100+50/5+5A as per IS: 2705 having protection core class 5P10, burden of 15VA and metering core class CL1.0 and burden of 15VA, breaking capacity of 13.1 KV for 1.0 second
11KV VCB three phase indoor oil cooled PT of ratio 11KV/RT 3/10V/RT 3/110/RT 3 class 0.5-3, burden 100VA, insulation level 35/75 KV, voltage factor 1.2 cont and 1.9 for 30 sec, conforming to IS-3156
Supply and fixing in replacement HT fuse wire upto 60 amp as per site requirement mounting on insulator of 2 Pole/4 Pole structure complete with fused barrel for 11 KV complete all as specifed and directed.
Supply install ,testing and commissioning in replacement of Power pack unit input voltage 180-250 Volts and out put voltage 110 Volts DC having 4-digit degital Volt & Ammeter, High resolution D/A, A/D converter , Digital interface as standard function etc. including taking out US battery bank unit complete all as specified and as directed
Supply install ,testing and commissioning in replacement of Power pack unit input voltage 110 Voltage and out put voltage 24 Volt DC having 4-digit degital Volt & Ammeter, High resolution D/A, A/D converter , Digital interface as standard function etc. including taking out US battery bank unit complete all as specified and as directed
Disconnecting, opening of HT Capacitor bank of any description and any make of rating 11 KV indoor capacitor switching panel and outdoor capacitor bank type with automatic/manual control having output 2400 KVAR (Step rating proposed : 400 KVAR x 2+800 KVAR x 2 desired 0.99) for servicing / overhauling, taking out and removing unserviceable / defective parts including cleaning & servicing, greasing, oiling of the parts etc and replacement of unserviceable parts with new one, reassembling the HT Capacitor Bank after overhauling/ servicing and its testing complete all a specified and directed. Note: (i) Replacement of unserviceable parts shall be measured and paid for separately under appropriate item of Sch 'A' as supply only
Supply only HT HRC Fuses suitable for 11 KV, 400 KVAR complete all as specified and directed.
Supply only HT HRC Fuses suitable for 11 KV, 800 KVAR complete all as specified and directed.
Supply only NDVR Relay suitable for 400 KVAR step complete all as specified and directed.
Supply only Contactor coil 180 to 240 volt
Supply only Copper bus bar 50x10 mm length 1 mtr as per site requirement
Supply and fixing in replacement of transformer HT/LT bush as per site requirement suitable upto 630 KV transformer after disconnecting /removing overhead conductor / underground cables and earth strips etc and reconnections, testing and recommissioning of transformer to full satisfaction of Engineer-in-charge.
Repair to distribution transformer step down 11/0.433 KV indoor/outdoor type of capacity 100 KVA to 250 KVA, after dismantling the transformer carefully, opening the top cover of transformer for inspection /repair, draining out the transformer oil from the housing complete, taking out the core and winding by disconnecting the internal connections, removing the carbon/sludge deposit in transformer housing core, replacement of unserviceable rubber bushes and washers, replacement of tap changer winding and thimbles, replacement of silica gel, replacement of top cover gasket set including pasting with pasting material, replacement of worn out nut and bolts, replacement of unserviceable LT & HT bushes, cutting the burnt out winding and re-winding the same with suitable size of super enamelled copper/ aluminium wire as per existing guage, insulating the winding connection by using fire proof sleeve and fire proof tape, varnishing the coil, keeping the coils in electric oven chamber for 24 hrs to remove the moisture, painting of complete transformer body from outside and inside, marking of MES/SM Number etc, replacement of conservator tank glass, re-installing the core and winding inside properly, making the all connection with suitable copper lugs, filling of new transformer oil, reinstalling the top cover after cleaning and painting of housing, conservator tank, expulsion vent etc, Meggering the LT and HT side of the Transformer and testing complete all as specified and directed by Engineer-in-Charge. Note :- (i) Winding wire for making of coils, HT/LT bushes, new transformer oil will be measured & paid seperately (ii) Contractor is required to submit test report for repaired transformer duly signed by Engineer-in-Charge before installation.
All as per Srl item No 77.00 above but of capacity 11 / 0.433 KV, above 250 KVA upto 630 KVA complete all as directed.
Supply only brass terminal rod with nuts, bolts washers & bushings suitable for HT and LT side of the transformer of any make and capacity upto 100KVA complete.
Supply only super enamelled copper conductor wire of suitable gauge and size as per requirement for rewinding of 11/0.433 KV distribution transformer complete all as directed.
Supply only super enamelled aluminium conductor wire of suitable gauge and size as per requirement for rewinding of 11/0.433 KV distribution transformer complete all as directed.
Supply only tap changing switch suitable for operation on 11/0.433 KV distribution transformer with tappings on 2.5%, 5% and 7.5% on required basis for upto 630KVA capacity transformer.
Supply and replacing silica gel breather clear view type including first fill of good quality silica gel of capacity suitable for 100 KVA to 250 KVA transformer.
Supply and replacing silica gel breather clear view type including first fill of good quality silica gel of capacity suitable for 250 KVA to 630 KVA transformer.
Supply silica gel crystel filled in the breather of capacity suitable for 100 KVA to 630 KVA transformer complete all as directed.
Material and labour for cleaning and preparation of steel surfaces of existing dull painting of transformer outdoor type including radiators, cooling ducts, vent pipes, condensor etc and applying two coats of synthetic enameled paint (heat resistant type) according to to IS colour code by spray machine including writing MES /SM No. in capital letters of suitable size on body for capacity upto 160KVA transformer outdoor/indoor complete all as specified and directed
All as per item No: 86.00 but capacity above 200 KVA and upto 630 KVA.
Supply, installation, testing and commissioning of 33 KV single phase outdoor oil cooled PT of ratio 33KV/RT3/110 /RT3, Class 0.5, Burden100 VA -50 VA insulation level 70/170 KVP voltage factor 1.2 cont and 1.5 for 30 sec, conforming to IS 3156 incl taking down old/unsv the same all as specified and directed by Engr-in-Chage
Supply, installation, testing and commssioning of 33 KV single phase outdoor oil cooled CT of ratio 400/5-5 amp class 1.0 - 5P10 burden 15 VA insulation level 70 KV/170KV as per IS 2705 incl taking down old/unsv same all as specified and directed by Engr-in-Chage.
Repair to distribution Power transformer 33/11 KV outdoor type of capacity 3 MVA to 5 MVA , after dismantling the transformer carefully, opening the top cover of transformer for inspection /repair, draining out the transformer oil from the housing complete, replacement of unserviceable rubber bushes and washers, replacement of tap changer winding and thimbles, replacement of silica gel, replacement of all gasket set including pasting with pasting material, replacement of worn out nut and bolts, replacement of unserviceable HT bushes, painting of complete transformer body from outside and inside, marking of MES/SM Number etc, replacement of conservator tank glass, filling of new transformer oil, reinstalling the top cover after cleaning and painting of housing, conservator tank, expulsion vent etc, Meggering the Transformer and testing complete all as specified and directed by Engineer-in-Charge. Note :- transformer oil will be measured & paid seperately (ii) Contractor is required to submit test report for repaired transformer duly signed by Engineer-in-Charge before installation.
Supply and fixing in replacement expulsion fuse unit single pole mounted on insulator & steel frame complete with fused barrel (drop out fuse) suitable for 11 KV for current rating upto 20 Amp incl taking down old/unsv fuse unit complete all as specifed and directed.
Repairing / Servicing the Air break isolating switch HT 11 KV 200/400 Amps by replacing the defective major spares parts including provn of minor bolts nuts etc all as specified and directed. Note :- Major spare parts will be measured & paid seperately
Supply only Male contact/moving Contact Blade
Supply only Female contact/Fix Contact Jaw
Supply only Tinned copper Flexible jumper 200A/400 A
Supply only MS jumper carrier
Supply only Back Connector plate
Supply only Petroleum Jelly
Material and labour for earthing complete with copper plate earth electrode 600X600X3.15mm thick buried directly in ground (earth pit not less than 2.25 meter below ground level) with top edge of the plate not less than 1.5 metre below normal ground level connected to copper strip 20x3mm at two points by means of bolts and nut, check nut and washers including charcoal dust, common salt, necessary excavation in hard/dense soil, returning filling in and removal of surplus soil to a distance up to 50metres, PCC pit in 1:3:6 type CI (using 20mm grade stone aggregate) RCC 1:2:4 type B-1 (using 20mm grade stone aggregate ) 50mm thick pit cover, reinforced with 8mm dia TMT bars 75mm c/c, both ways MS handle 12mm dia, GI funnel, wire mesh and GI watering pipe of 20mm bore GI (light grade) and earth lead protection pipe 40mm bore (light grade) all as specified, directed and shown in electrical plate No 3 of SSR Part-I including testing and replacment of old unserviceable earthing, complete all as specified and as directed by Engineer-in-Charge. Note : GI strip and protection pipes 40 mm GI light grade up to 7.5 metre is included in unit rate and beyond that the same will be measured separately.
Material and labour for danger notice plate of 1.6 mm thick mild steel sheet vitreous, enamelled white with letters, figures and conventional skull and bones in signal red colour and fixed with MS clamps made of 25x3m MS flat, bolts and nuts for HT 25x20cm size incl taking down old/unsv plate complete all as specified and directed
Supply and fix in replacement of PCB (card) all mice and transistor of 5 KVA UPS input voltate 185 -265 Volt and out put voltage 110 volt DC complete incl taking down unsv as per existing make all as specified and directed by Engr-in-charge
Supply and fixing in replacement of 4 ZONE Microprocessor Based Main Fire Alarm Control Panel including, testing & commissioning complete complete with visual indications for short circuit fault, open circuit fault, fire condition and all other standard facilities as per IS:2189 with mimic diagram for all area/zone covered, complete with all connections, interconnections, wall mounted type fabricated out of 1.6 mm CRCA sheet, dust and vermin proof, power coated, solid-state sector control panel made in standard cabinet with Zone healthy, isolate, healthy, short , open , fire signal, visual test mode, suitable for operation 220 volts AC power supply / 24 V DC output, automatic battery charger, 24 volts maintenance free batteries sufficient for 30 Minutes during an emergency conditions etc. complete in all respect.
Supply and fixing in replacement of heat detector operating at 54§C/57§C with rate of rise cum fixed temperature (dual thermistor) type with mounting base including testing & commissioning complete with all connection etc. as required.
Supply and fixing in replacement of smoke detector with builtin LED and mounting base complete with all connections including testing & commissioning complete etc as required.
Supply and fixing in replacement of of manual call boxes of MS construction in surface/recess with stainless steel chain & hammer assembly complete with glass and push button etc. as required.
Supply and fixing in replacement of response indicator on surface/recess MS box having two LEDs metallic cover complete with all connections etc. as required.
S&F in replacement of fire alarm sounder with facility to make announcement, mounted in M.S. box (16 SWG) with hinged cover plate & suitable for operation with amplifier i/c line matching transformer testing & commissioning etc complete as required. Agni 2.00 410.00 820.00 7 Supply & fixing PVC insulated PVC sheathed str
Supply and fixing in replacement PVC insulated PVC sheathed stranded armoured (ISI Marked) copper conductor 3 core, 1.5 sqmm FRLS cable on surface, including connection and steel conduit not less than 32mm dia with clam, etc. complete as required.
Supply and fixing in replacement WTI relay suitable for 3.15 MVA /5 MVA transformer control Panle complete all as specified and directed by Engr-in-charge.
Supply and fixing in replacement OTI relay suitable for 3.15 MVA/ 5 MVA transformer control Panle complete incl taking down unsv all as specified and directed by Engr-in-charge.
Supply and fixing in replacement Master tripping relay with display suitable for 3.15 MVA/5 MVA transformer control Panle complete incl taking down unsv all as specified and directed by Engr-in-charge.
Dismantling existing ACSR conductor of any size/type overhead line from PCC/Steel poles complete all as specified and directed by Engineer-in-Charge.
Dismantling existing MS works such as cross arms, clamps, hooks etc from PCC/Steel poles complete all as specified and directed by Engineer-in-Charge.
Taking down of existing any type or any size of insulator from PCC/Steel poles complete all as specified and directed by Engineer-in-Charge.
Relaying of existing any type or any size cable cover in trench for cable protection in trench retrieved from item No 11 of this schedule complete all as specified and directed by Engineer-in-Charge.
SRI SAI CONSTRUCTION COMPANY (BID ID -3274065)
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .