| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹28.3 LAccepted-AOC | L1 | Accepted-AOC L1 | |
| 2 | L2₹34.0 L+₹4.5 L (15.4%)Rejected-Finance | L2 | Rejected-Finance L2 | |
| 3 | L3₹34.1 L+₹4.6 L (15.8%)Rejected-Finance 34 35 ASHOKA ESTATE NEAR S S PUBLIC SCHOOL SEWLA SARAI AGRA 282001 | AGRA | UTTAR PRADESH | 282001 | L3 | Rejected-Finance L3 | |
| 4 | L4₹34.2 L+₹4.8 L (16.2%)Rejected-Finance | L4 | Rejected-Finance L4 | |
| 5 | L5₹34.3 L+₹4.8 L (16.5%)Rejected-Finance | L5 | Rejected-Finance L5 |
Tender Value
₹49.9 L
EMD Value
₹99,800
Closing Date
12 Sept 2022, 6:00 pmClosed
GE Jaipur
Garrison Engineer, Military Engineer Services, Khatipura road, Jaipur 302012
REPAIR/MAINT OF INTERNAL ELECTRIFICATION WORK IN ZONE II A AREA AND REPAIR / MAINT OF CEILING FANS, GEYSER IN ZONE II A AND B AREA UNDER AGE E/M OF GE JAIPUR
2022_MES_545674_1
GE/J-37/2022-23
Open Tender
Electrical and Maintenance Works
Item Rate
330 days
Jaipur
Please refer Tender documents.
5 documents required · 5 mandatory
₹500
GE Jaipur
₹99,800
Yes
24 Sept 2022
16 Aug 2022
14 Sept 2022
16 Aug 2022
12 Sept 2022
29 Aug 2022
16 Aug 2022 - 28 Aug 2022
Amount
M&L for taking down ceiling fan/exhuast fan/fresh air fan/wall mounted fan/padestral fan for repair/servicing i.e. winding/greasing /oiling etc., any sweep size, any make and any type model, ceilng cable end with tape, dismandling the blades, removing fan and deposit the blades/motor to store for repairing/ servicing complete all as specified and as directed by Engineer-in-charge Note:- (i) Contractor will resposible for taking down ceiling fan from location and carrying with saftey and deposit for repair/sevicing i.e winding/greasing /oiling in E/M yard.
M&L for opening of ceiling fans to check the all parts and taking out of old burnt binding of fan and rewinding of fan with super enamelled copper winding wire of existing gauge including varnishing and reassembling after properly greasing the bearing/bush and replacement of twin core flexible copper wire PVC insulated 23/0.0076 one metre long and including S&F unserviceable connectors, wiring, capacitor clamp, split pin for fan incl reassembling the same and testing complete of Ceiling fan 1200 mm sweep (Note:- (Note:- (i) Contractor will be arranged all required T&P repair for ceiling fan/sevicing i.e winding/greasing /oiling in Piru line E/M Zone II yard (ii) Damaged screws, washer replaced under above items and rate quoted shall also be deemed to including the cost of the same.
All as per item No 2 above but Ceiling fan 1400 mm sweep.
All as per item No 2 above but Exhaust fan 450 mm sweep
All as per item No 2 above but Exhaust fan 375 mm sweep
All as per item No 2 above but Exhaust fan 300 mm sweep
All as per item No 2 above but Exhaust fan 250 mm sweep
All as per item No 2 above but Wall fan mounted fans/ cabin fans of any size & make
Supply only ball bearing No 6201. (Make : NBC/SKS or equivalent as approved by GE)
All as per item No 9 above but bearing No 6202
All as per item No 9 above but bearing No 6203.
All as per item No 9 above but bearing No 6204
S&F in repair AC film capacitor of 2.5 mfd, 440 volts suitable for any type ceiling fan in FR plastic casing including connection complete.
S&F in repair AC film capacitor of 4 mfd, 440 volts suitable for any type ceiling fan in FR plastic casing including connection complete.
Supply only gun metal copper bush for ceiling fan as per existing pattern.
Supply only as in repair blade screw for ceiling fans any size and make.
Supply only rubber real complete.
S&F as in repair PVC canopy including screws of any make/ size. (Note : Colour of canopy shall be as per existing fan).
S&F as in repair fan blades of size 1200mm or 1400 mm of any make. (Make : CROMPTON / ORIENT / BAJAJ or equivalent as approved by GE)
M&L scraping, cleaning and preparation of old painted surfaces of ceiling fans and spray painting with two coat of white enameled paint over a coat of red oxide primer complete.
Taking down, ceiling fan, opening and servicing, cleaning, greasing at site and including minor repair and re-fixing after testing complete
Renewal of rubber reel with a pair of clamp, nuts, bolts, split pins etc suitable for ceiling fan down rods of any size and make as required.
S&F in repair down rod of ceiling fan made of MS pipe 15 mm bore including cutting, threading, painting etc as 30 cm to 60 Cm required.
M&L for clamp and back plates fabricated from steel sections conforming to Gde Fe 410-O or Fe 310-O including nuts, bolts, washer, drilling holes for bolts in any shape or size for fixing ceiling fan complete.
S&F in repair PVC insulated and sheathed flexible 3 core cable with copper conductor of size 0.5 sqmm complete.
M&L for new hook/clamp for hanging ceiling at new location including cutting the existing PCC/RCC surface and making good with PCC or as directed.
Supply and fixing ceiling fan 1200mm sweep 50 Hz AC 230 votls, 5 star rated in white colour with bldc fan motor, blade set, 0.45 mtr down rod, canopy set, rubber reel including 0.5 Sqmm three core PVC insulated flexible copper conductor multistranded wire from fan motor to ceiling and writing MES No. on fan body as directed.
Taking down carefully storage type water heater (geyser) any make and capacity from clamp/bolts including disconnecting water and electric connection including checking defects and re fixing the same and connecting up after cleaning of geyser and repair complete. (Note - Repair work shall be measured separately).
Supply only geyser apparatus plate (any make, any type) copper alloy chromium plated suitable for geysers 25/50 litre capacity including rubber gasket, nuts / bolts etc complete.
Supply only heating element 2.0 KW, 230 volts, ISI marked suitable for 25/ 50 litre capacity geysers of any type as required.
Supply only thermostat ISI marked suitable for 25/50 litres geysers as required.
Supply only stainless steel inner tank suitable for 25 litre capacity geysers housing complete.
Supply only stainless steel inner tank suitable for 50 litre capacity geysers housing complete
Repair of inner copper tank of geysers 25/50 litre capacity with gas welding not exceeding 5 mm thick to make it leak proof complete.
Repair of apparatus plate of geysers 25/50 litre capacity by brazing not exceeding 5 mm thick complete.
Supply only dis cut out switch suitable for 25 litre capacity geysers complete.
Supply only capillary thermostat set suitable for 25 litre capacity geysers complete.
S&F in repair brass chromium plated, flexible pipe connection 15 mm bore 450 mm long heavy duty suitable for hot water supply with two numbers brass chromium plated nuts at end complete.
M&L for preparation of old painted surface by removing old paint etc and painting of geyser 25/50 litre with two coats of synthetic enamelled white paint and writing MES No (Letters height 10 cm) complete.
S&F in repair of PVC insulated over all PVC sheathed three core copper cable of size 4 sqmm complete.
Supply and fixing in replacement hot water tank made out of 2.5mm thick MS sheet duly welded with seamless welding, water leak proof with all accessories such as inlet water connection, outlet water connection, normal water connection, overflow water connection etc including fixing PUF insulation 32 mm thick capacit 200 ltr all as required.
Supply and fixing in replacement hot water tank made out of 2.5mm thick MS sheet duly welded with seamless welding, water leak proof with all accessories such as inlet water connection, outlet water connection, normal water connection, overflow water connection etc including fixing PUF insulation 32 mm thick capacit 300 ltr all as required
S&F in replacement hot water pipe duly insulated with glass wool and aluminium cladding 15mm bore.
Servicing of solar collector panel of capacity 200/ 300 ltrs, cleaning the entire panel thoroughly after opening it, minor repair like nuts, bolts, washer, clamps etc as required and testing complete all as directed.
S&F water heater 50 litre capacity horizontal type BEE star rating 5 in approved colour, heating element 2.0 KW, adjustable temperature setting knob for temperature setting between 25° C to 75° C, outer tank made of non metallic engineering plastic, inner tank made of extra thick superior cold rolled steel provided with high density PUF insullation complete. Make Havells Monza EC H or equivalent as approved by GE.
S&F water heater 50 litre capacity BEE star rating 5 in approved colour, heating element 2.0 KW, adjustable temperature setting knob for temperature setting between 25° C to 75° C, outer tank made of non metallic engineering plastic, inner tank made of extra thick superior cold rolled steel provided with high density PUF insullation complete.
S&F water heater 25 litre capacity BEE star rating 5 in approved colour, heating element 2.0 KW, adjustable temperature setting knob for temperature setting between 25° C to 75° C, outer tank made of non metallic engineering plastic, inner tank made of extra thick superior cold rolled steel provided with high density PUF insullation complete.
Supply and fix in replacement of motor of existing capacity, for PVC fresh air fan 200 mm sweep any make or as specified by Engr in charge
Supply and fix in replacement of motor of existing capacity, for PVC fresh air fan 250 mm sweep any make or as specified by Engr in charge
Supply and fix in replacement of motor of existing capacity, for PVC fresh air fan 300 mm sweep any make or as specified by Engr in charge
Supply and fix in replacement PVC fresh air fan 200 mm sweep with louvers, fan motor and accessories complete including making connections.
Supply and fix PVC fresh air fan 250 mm sweep with louvers, fan motor and accessories complete including making connections.
Supply and fix PVC fresh air fan 300 mm sweep with louvers, fan motor and accessories complete including making connections.
Supply only PVC insulation tape of superior quality
Taking down old louver and supply and fix new louver of exhaust fan of size 300 mm complete all as specified and directed by Engr-in- charge.
Taking down old louver and supply and fix new louver of exhaust fan of size 250 mm complete all as specified and directed by Engr-in- charge.
S & F in replacement 20 amps single pole and neutral socket outlet with 2 pole and earty metal enclosed plug top in poweder coated CRCA steel ssheet enclosre recess mounted with chained matel cover for socket out let including one no single pole MCB 20 Amps.
Supply only 20 amps single pole and neutral socket outlet with 2 pole and earty metal enclosed plug top in poweder coated CRCA steel sheet enclosre recess mounted with chained matel cover for socket out let with including one no single pole MCB 20 Amps.
Taking down carefully surface aluminum or copper point wiring including PVC concealed conduit for (light, fan, socket, bell or power) including fixture and fittings such as switches, ceiling rose, regulators, sockets, light fittings etc and making good disturbed surfaces complete.
M&L for point wiring with 1100 volts grade PVC insulated FRLS multistranded copper conductor cable 1.5 Sqmm (Phase-Red, Neutral-Black) and earth continuity conductor 1.5 Sqmm (Green) drawn into and including concealed rigid non metallic PVC condiut medium grade not less than 20mm dia ISI marked ivory colour with all conduit fittings/fixing accessories and unwelded sunken galvanised pressed steel terminal boxes of thickness not less than 1.0 mm covered with 3 mm thick phenoic laminated white sheet cover for mounting switches, scokets, fan regulators as required for one light point controlled by one switch.
All as per item No. 60 here-in-before but one fan point controlled by one switch.
All as per item No. 60 above but one light point controlled by two, two way switch.
All as per item No. 60 here-in-before but one socket outlet 6 amp controlled by one switch on the same board with other switches.
All as per item No. 60 here-in-before but one socket outlet 6 amp controlled by one switch on indepdendent board.
All as per item No. 60 here-in-before but one bell point controlled by one bell push.
M&L for point wiring with 1100 volts grade PVC insulated FRLS multistranded copper conductor cable 4.0 sqmm (Phase - Red, Neutral - Black) and earth continuity conductor 4.0 sqmm (Green) drawn into and including concealed conduit and terminated in and including modular metal flush boxes for mounting modular cover plate & frame for one socket point 16 Amps controlled by one switch.
M&L for point wiring with 1100 volts grade PVC insulatd FRLS multistranded copper conductor cable 1.5 Sqmm (Phase-Red, Neutral-Black) and earth continuity conductor 1.5 Sqmm (Green) drawn into and including PVC casing-capping not less than 32x16 mm ISI marked ivory colour with all fittings/fixing accessories and unwelded sunken galvnised pressed steel terminal boxes of thickness not less than 1.0 mm covered with 3mm thick phenlic laminated white sheet cover/ PVC gang box for mounting sheet cover for mounting switches, sockets, fan regulators one light point controlled by one switch.
All as per item No. 67 here-in-before but one fan point controlled by one switch.
All as per item No. 67 here-in-before but one light point controlled by two, two way switch.
All as per item No. 67 here-in-before but one socket outlet 6 amp controlled by one switch on the same board with other switches.
All as per item No. 67 here-in-before but one socket outlet 6 amp controlled by one switch on indepdendent board.
All as per item No. 67 here-in-before but one bell point controlled by one bell push.
M&L for point wiring with 1100 volts grade PVC insulatd FRLS multistranded copper conductor cable 4.0 Sqmm (Phase-Red, Neutral-Black) and earth continuity conductor 4.0 Sqmm (Green) drawn into and including PVC casing-capping not less than 32x16mm ISI marked ivory colour with all fittings/fixing accessories and unwelded sunken galvnised pressed steel terminal boxes of thickness not less than 1.0mm covered with 3mm thick phenlic laminated white sheet cover / PVC Gang box for mounting sheet cover for mounting switches, sockets for one 16 Amps socket outlet point controlled by one switch on independent board.
S&F angle holder, insulated polycarbonate body with back plate complete.
S&F switch piano flush button single pole one way 6 Amp complete.
S&F switch piano flush button single pole one way 16 Amp complete.
S&F flush type, 6 Amp, single pole, two way complete.
S&F bell push, flush type, 6 Amps 240 volts complete.
S&F socket outlet, 2-in-1, 3 pin 6 & 16 Amps flush type compete.
S&F socket outlet, 2-in-1, 3 pin 6 Amps flush type compete.
S&F in repair switch piano flush button single pole one way 6 Amp complete.
S&F in repair switch piano flush button single pole one way 16 Amp complete.
S&F in repair flush type, 6 Amp, single pole, two way complete.
S&F in repair bell push, flush type, 6 Amps 240 volts complete.
S&F in repair socket outlet, 2-in-1, 3 pin 6 & 16 Amps flush type compete.
S&F in repair socket outlet, 2-in-1, 3 pin 6 Amps flush type compete.
S&F in repair modular hum free electronic step fan regulator, 120 watt 2 module all as per Legrand cat ref no. 675530 or equivalent as approved by GE.
S&F modular fan regulator 120 watts, 2-module AC 230 Volts.
S&F in repair Fan step regulator, 120W - 2 module on existing as per requirement complete all as specified and as directed by Engineer-in-charge.
S&F in repair modular hum free electronic step fan regulator, 100 watt 2 module all as per Legrand Britzy cat ref no. 673430 or equivalent as approved by GE.
S&F in repair hum free electronic step fan regulator 120-280 volts of 100 watts capacity (socket type) including connecting up complete.
S&F hum free electronic step fan regulator 120-280 volts of 100 watts capacity (socket type) including connecting up complete.
S&F in repair stepped type electronic fan regulator flush type on existing laminated sheet all as specified and as directed by Engineer-in-charge.
S&F wire less door bell AC 240 volts, single pole complete.
S&F door bell AC 240 volts, single pole complete.
S&F ceiling rose 3 plates polycarbonate body complete.
S&F modular switch one way 6 amp 1 module all as per Legrand Britzy cat ref no. 673401 or equivalent as approved by GE.
Supplying and fixing modular socket 6 - 2/3 pin combined 2 module all as per Legrand Mylinc cat ref no. 675555 or equivalent as approved by GE.
Supplying and fixing modular switch one way 16 amp 1 module all as per Legrand Mylinc cat ref no. 675511 or equivalent as approved by GE.
S&F modular socket 6/16 Amps, 2/3pin combined 2 module AC 230 volts.
S&F Modular 2 way 10 A switch 1 Module
Supplying and fixing in repair modular socket 6 - 2/3 pin combined 2 module all as per Legrand Mylinc cat ref no. 675555 or equivalent as approved by GE.
S&F repair modular socket 6 Amps, 2/3 pin combined 2 module AC 230 volts.
S&F repair modular switch 1 way 16 Amps, 230 volts, 1 module.
Supplying and fixing repair modular socket 6/16 - 2/3 pin combined 2 module all as per Legrand Mylinc cat ref no. 675555 or equivalent as approved by GE.
S&F repair Modular 2 way 10 A switch 1 Module
Supplying and fixing repair modular socket 6/16 - 2/3 pin combined 2 module all as per Legrand Mylinc cat ref no. 675555 or equivalent as approved by GE.
S&F in repair modular socket 6/16 - 2/3 pin combined 2 module all as per Legrand Britzy cat ref no. 673455 or equivalent as approved by GE.
Supplying and fixing repair modular socket 6 amp 2/3 pin combined 2 module all as per Legrand Mylinc cat ref no. 675550 or equivalent as approved by GE.
S&F modular blanking plate 1 module.
S&F modular whiter cover plate with frame 3 module.
S&F modular whiter cover plate with frame 4 module.
S&F modular whiter cover plate with frame 6 module.
S&F modular whiter cover plate with frame 8 module.
S & F in repair plastic surface boxes 3 moduler for fixing modular switch and socket
S & F in repair plastic surface boxes 4 moduler for fixing modular switch and socket
S & F in repair plastic surface boxes 6 moduler for fixing modular switch and socket
S & F in repair plastic surface boxes 8 moduler for fixing modular switch and socket
Taking down carefully sub main wiring with PVC casing capping/PVC surface conduit and making good disturbed surfaces complete.
M&L for submain wiring with two runs of single core PVC insulated and unsheathed, multistranded FRLS copper conductor of size 4.00 sqmm, LT cable, 1100 volts grade and one run of 4 sqmm single core, multistrand copper conductor (green) as earth continuity conductor drawn into 20 mm dia concealed conduit complete all as specified and directed. NOTE: Two runs of 4 sqmm cable, one run of 4 sqmm cable along with conduit including acessories shall be measured as one running metre of submain wiring.
M&L for submain wiring with two runs of single core PVC insulated and unsheathed, multistranded FRLS copper conductor of size 6.00 sqmm, LT cable, 1100 volts grade and one run of 6 sqmm single core, multistrand copper conductor (green) as earth continuity conductor drawn into 20 mm dia concealed conduit complete all as specified and directed. NOTE: Two runs of 6 sqmm cable, one run of 6 sqmm cable along with conduit including acessories shall be measured as one running metre of submain wiring.
All as per item No. 121 above but 2x10 Sqmm + 1x10 Sqmm earth in 25mm dia conduit.
S&F in repair MCBs of 'C' series single pole 6 to 32 Amps having breaking capacity 10 KA, ISI marked including required wiring connections with copper lugs of suitable size provided in MCB DBs complete.
S&F in repair MCBs of 'C' series SPN 10 to 32 Amps having breaking capacity 10 KA, ISI marked including required wiring connections with copper lugs of suitable size provided in MCB DBs complete. Make : Legrand Cat Ref No. 408631 to 408636 or equivalent in Schneider/Hager as approved.
S&F in repair MCBs of 'C' series four pole 63 Amps having breaking capacity 10 KA, ISI marked including required wiring connections with copper lugs of suitable size provided in MCB DBs complete.
S&F in repair MCBs of 'C' series single pole 20 Amps having breaking capacity 10 KA, ISI marked including required wiring connections with copper lugs of suitable size provided in MCB DBs complete.
S&F in repair MCCB four pole, 125 Amps, 16 KA thermally adjustable between 70 to 100% including 4 spreader link set of same make as that of MCCB for connection, required lugs as required.
S&F in repair LED batten (1.2M) made of CRCA sheet housing with a PC glossy diffuser duly prewired connection having a nominal system lumen output of 2000 lumens at a minimum system efficacy of 115 lumen per watt and total power consumption not more than 20 watt including driver. It has a rated system life time of 40000 burning hours at L70 and should have a color temperature of 6500K, CRI>80, THD<10% and PF>0.95 complete.
S&F in recess mounted LED panel of round shaped , cap 12 W, Long life 25000 burning hours including making connection Complete.
S&F in repair recess mounted LED panel of size 2'x2', through replacing old fluorescent light with LED lights 04 nos in each panel 32 W, Long life 25000 burning hours including making connection Complete.
S&F in repair LED fixture 10 watt having lumen output 100 lumens per watt including connection.
S&F in repair LED bulk head fitting 9 watt IP 66 & IK 09 with pressure die cast aluminium housing & polycarbonate diffuser duly pre wired connection with 0.75 Sqmm PVC insulated & sheathed three core flexible multi stranded copper conductor cable complete.
Supply and fixing in repairs energy efficient recessed mounted LED luminaire suitable for 2'x2' grid ceiling with fullglow fully diffused diffuser and lumen output of 3600 lumens having constant current electronic driver of 36 watt duly connected with 0.5 sqmm white colour PVC insulated & sheathed three core flexible multi stranded copper conductor cable as required.
Supply and fixing in repairs energy efficient recessed mounted LED luminaire suitable for 180 mm dia ceiling with flat diffuser and lumen output of 115 lumens per watt of 18 watt having constant current electronic driver duly connected with 0.5 sqmm white colour PVC insulated & sheathed three core flexible multi stranded copper conductor cable as required PF not lessthen 0.95 ITHD lesthen or equaal 10% opreting voltage 140-270 Volt .
Supply and fixing in repair LED based Bollard 10 Watt with MS pipe housing with glare free PMHA Difuser , IP 65 hight of light 1 mtr including Mortar Base and connetion wire of suitabe size complete .
M&L for earthing with galvanized steel earth plate electrode 600mmx600mmx6mm thick buried directly in ground (earth pit not less than 2.25 meter deep below normal ground level) with the top edge of the plate not less than 1.5m below normal ground level connected to galvanized earth lead wire 4mm dia by means of steel bolts, nuts, check nuts and washers all as shown in electrical plate No. 03 of SSR Part -I connected to earthing point and including 15mm bore light grade G.I. protection pipe (upto 7.5 mtr from edge of the pit), PCC pit in mix 1:3:6 type C1 with PCC 1:2:4 type B-1, 40mm thick cover, watering arrangement with funnel and wire mesh and 20mm bore light grade G.I. watering pipe, common salt and charcoal filling, necessary excavation and earh work including testing on completion.
Taking down MCB distribution boards with incoming and outgoing controls any make any capacity after disconnecting complete.
S&F MCB distribution board, tripple pole and neutral, powder coated CRCA steel sheet, suitable for MCCB incomer upto 160 Amps, 4 way 415 volts, degree of protection IP 43, IK-09 with reversible double door, recess mounted, having 250 Amps insulated tinned copper bus bar, neutral busbar, earth bar, din bar, detachable gland plate, interconnection, earthing connection, blanking plates in unused spaces as required.
S&F in repair single pole and neutral enclosure with a two pin and earth plug and socket complete with one Double pole MCB 20 Amps
S&F MCB distribution board, powder coated, CRCA steel sheet, degree of protection IP 43, IK-09 with reversible double door, recess mounted , having insulated 100 Amps tinned copper bus bar, neutral bus bar, earth bar, din bar, detachable gland plate, interconnection, earthing connection, blanking plates in unused spaces as required with SPN, 240 volts, 4 ways.
All as per item No 140 above but SPN, 240 volts, 8 ways.
All as per item No 140 above but SPN, 240 volts, 12 ways.
All as per item No 140 above but TPN 415 volts, 4 ways.
S&F in repair exhaust fan of sweep 200 mm made of sturdy Engineering plastic complete with louvers shutter, voltage 230V, 50 Hz, RPM 1200, Copper winding complete all as directed
S&F in repair exhaust fan of sweep 250 mm made of sturdy Engineering plastic complete with louvers shutter, voltage 230V, 50 Hz, RPM 1200, Copper winding complete all as directed
S&F in repair exhaust fan of sweep 300 mm made of sturdy Engineering plastic complete with louvers shutter, voltage 230V, 50 Hz, RPM 1200, Copper winding complete all as directed
Supply, installation, testing and commissioning of LT panel board fabricated out of 2mm thick stainless steel (SS 316) with copper bus bar 4 pole equal of capacity in colour code R, Y & B, 200 Amps 415 Volts indoor type wall mounted of size not less than 750mmx650mmx250mm, installed on procelain insulators with bus bar chamber. The panel shall be dust and vermin proof, protection class IP 42 class, front opening & compartmental type with approach for cable entry and for easy maintenance duly internally wired with FRLS, PVC insualated stranded copper conductor cable of 1.0 Sqmm including LED indicator for R, Y & B and comprising of the following :- Incoming : One number MCCB 125 Amps 4 pole 16 KA 415 Volts, 70-100%, 50 Hz Make Legrand /Hager/Schneider. Outgoing : (a) MCB DP 40 Amps 'C' series 10 KA AC 240 volts-05 Nos. (b) Fixing only old serviceable Single phase tamper proof meter with optical port 10 to 60 Amps-04 Nos.
Supply only angle holder, insulated polycarbonate body with back plate complete.
Supply only LED driver sutable for LED reccessed panel light cap not more than 40 watt, Make Philips driver 441537008480 or equivalent as approved by GE
Supply only switch piano flush button single pole one way 6 Amp complete.
SSupply only switch piano flush button single pole one way 16 Amp complete.
Supply only flush type, 6 Amp, single pole, two way complete.
Supply only bell push, flush type, 6 Amps 240 volts complete.
Supply only socket outlet, 2-in-1, 3 pin 6 & 16 Amps flush type compete.
Supply only socket outlet, 2-in-1, 3 pin 6 Amps flush type compete.
Supply only hum free electronic step fan regulator 120-280 volts of 100 watts capacity (socket type) including connecting up complete.
Supply only door bell AC 240 volts, single pole complete.
Spply only insulation tape of superior quality for day to day maintenece Make : Anchor or equivalent as approved by GE
Supply only PVC insulated FRLS multistranded copper conductor cable 1.5 Sqmm
Supply and fixing in repair PVC insulated alluminium wire of 6 Sqmm twin core wire at wall/in trench or as specified by engineer in charge
Excavation in trenches not exceeding 1.5 m wide and n.exc. 1.5 m deep for foundation of poles/stay/cable etc including getting out in any type of soil complete all as specified and directed by Engr-in-Charge.
Returning filling in (soil) including spreading levelling, watering and well ramming in layers not exc 25cm thick complete
Removal of excavated soil to a distance n.exc 50 m and depositing where directed at a level not exc 1.5 mtr above the ground level/starting point compalete.
M&L Sand cushioning to the under ground electric cable complete all as specified considering 19.75 of SSR part -I
M&L Sub Class 'B' brick covering protection to the eletric cable laid dry flat transversally along the length of cable on sand cushioning with width equal to length of brick complete.
Dismantling and taking out UG cable any size unserviceable items fixed in any position and removal from site, all as directed.
S&F 1100 volt grade heavy duty XLPE cable with PVC insulated aluminum conductor served with inner sheathing of PVC tape armoured with galvanized steel strip or wire and overall PVC sheathed of size 25 Sqmm nominal cross section 4 core laid in trenches,fixed to pole or passing through pipes including all necessary clamps, nuts, bolts washers complete all as specified and directed.
Schedule of Credit
SHREE BHAGWATI ENTERPRISES
M/S SHARADA ASOCIATE
M/S Sheeba Enterprises
Shree Karni Electrovision
M/S TRADE LINKERS
M/s Prakash Enterprises
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .