Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹17.1 LAccepted-Finance | L1 | Accepted-Finance Being L1 Bidder | |
| 2 | L2₹20.0 L+₹2.9 L (16.8%)Rejected-Finance BLDG NO 22 2079 COAST GUARD ROAD NEAR COAST GUARD FAMILY ACCOMMODATION MUNDAMVELI PO PALLURUTHY VII ERNAKULAM 682 507 | ERNAKULAM | ERNAKULAM | KERALA | 682507 | L2 | Rejected-Finance Not being L1 Bidder | |
| 3 | L3₹20.1 L+₹3.0 L (17.4%)Rejected-Finance | L3 | Rejected-Finance Not being L1 Bidder | |
| 4 | L4₹20.5 L+₹3.4 L (19.8%)Rejected-Finance | L4 | Rejected-Finance Not being L1 Bidder |
Tender Value
₹26 L
EMD Value
₹52,000
Closing Date
25 Aug 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE NAVY LAKSHADWEEP
GE NAVY LAKSHADWEEP Coast Guard Road, Kavaratti Island, Lakshadweep
ADDITION ALTERATION TO P 01 BUILDING AND PROVISION OF LIGHTNING ARRESTORS AT VARIOUS BUILDINGS STRUCTURES AT ANDROTH UNDER GE NAVY LAKSHADWEEP
2021_MES_463486_1
8281/E8
Open Tender
Civil Works
Item Rate
180 days
GE NAVY LAKSHADWEEP
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE NAVY LAKSHADWEEP
₹52,000
Yes
30 Sept 2021
29 Jul 2021
27 Aug 2021
29 Jul 2021
25 Aug 2021
11 Aug 2021
29 Jul 2021 - 7 Aug 2021
60 days
Amount
PROVISION OF LIGHNING ARRESTORS AT VARIOUS BUILDINGS/STRUCTURES AT ANDROTH Material and Labour for copper earthing complete for with Copper earth plate electrode of size 600 mm x 600 mm x 3.15 mm thick buried directly in ground earth pit not less than 2.25 Mtr deep below ground level with top edge of the plate not less than 1.5 Mtr below normal ground level, Alternate layers of charcoal & common salt Crystal, in and including back filling compound(BFC Chemical) in layers upto the top edge/ ground level and connected to copper earth strip 20 x 3 mm by means of bolts, nuts, check nuts & washers of copper and connecting to earth dolly, equipment all as shown in electrical plate No. 3 of SSR Part I of 2010 & testing complete including 40mm dia light grade GI pipe upto 7.5 mtr long, excavation in any type of strata, RCC ( 1:2:4 ) type B1 earthing chamber, reinforced with 8mm dia TMT bars @ 7.5 cm c/c both ways, pre cast slab 50 mm thick in cement concrete ( 1:3:6 ) type C1 ( reinforced with welded steel wire fabric (XPM) weight not less than 4 Kg / Sqm with frame, including 20 mm bore water pipe medium grade GI Tubing including GI Funnel , wire mesh etc complete all as specified in EP No. 3 fo SSR Part I 2010 and as directed by Engineer-in-Charge. NOTE :- (i) Copper earth continuity conductor 20x3 and GI light grade protection pipe 40mm dia beyond 7.5 mtr shall be measured and paid under the respective items). (ii) The rate is is inclusive of excavation and earthwork in any type of soil, RFR and removal
Supply & laying of lightening conductor madeup of copper conductor fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc... as required using 20 x 3 mm strips including all connection all as specified and as directed by Engineer in Charge
Supply and fix Air termination, single pointed, copper rod 12mm dia and 300mm long including all connection all as specified and as directed by Engineer in Charge
Supply and fix porcelain insulators of height not less than 50 mm clearance fixed to floor/wall/celing and provision for fixing lightening conductor including necessary fixing arrangements such as nut, bolts or welding etc.. Complete all as speified and as directed by Engineer in Charge
Supply and lay GI pipe, light grade of 40mm dia in trenches / fixed on walls / on roof for mechanical protection to copper strip of size 20x3 mm with all fittings such as bends, sockets, reducers union etc, complete all as specified and as directed by Engineer in Charge
Cutting the existing PCC road of width 0.25 Mtr x 0.25 Mtr depth x 3.0 Mtr length for laying the GI pipe light grade with all fittings such as bends, sockets, reducers union etc... including excavation in any type of soil, RFR , removal and filling with PCC (1:2:4), Type B-1 upto 15 cmon the top portio matching with the existing PCC road surfaces and remaining depth with the retrived earth for making the the road cut portion good all as specified and as directed by Engineer in Charge
Excavation in trenches not exceeding 1.5 mtr wide and not exceeding 1.5 m in depth for taking out /for laying under ground cables/pipes etc and getting out in soft/loose soil complete all as specified and as directed by Engineer in Charge
Returning filling in including spreading, levelling, watering and well ramming in layers not exceeding 25 cms complete all as specified and as directed by Engineer in Charge
Removing excavated soil to a distance n-exc 50 mtr and depositing where directed at a level not exceeding 1.5 mtr above the starting point complete all as specified and as directed by Engineer in Charge
Material and Labour for test point terminal block made out of gun metal of phosphorus bronze of size 75 x 7 5x 25mm, copper strip of 32x6 mm, 100mm long, drilled and secured using 4 nos. 8mm dia, 25mm long hexagonal head brass screws including box of size 90 x 90 x 90mm made of 1.6 mm plain steel sheet painted with two coat of epoxy enamel paint over coat of epoxy primer and secured to wall for protection of test point complete as specified and as directed by Enginner-In-Charge
Supply and lay 25 mm dia bore of CPVC Pipes SDR 11 & Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors complete all as specified and as directed by Engineer in Charge
Supply and fix ball valve, CPVC of size 25 mm dia fixed complete all as specified and as directed by Engineer in Charge
Material and labour for PCC (1 : 3 : 6) type C2 using 40mm graded stone aggregate for foundation, filling and mass concrete, including necessary use and waste of form work complete all as specified and as directed by Engineer in Charge.
ADDITION/ ALTERATION TO P-01 BUILDING AT ND ANDROTH Taking down Chowkhats or frames exc. 1.5 sqm but not exc. 4 sqm each, with shutters (without taking off shutters from the frames) complete all as specified and as directed by Engineer in charge.
Taking down Chowkhats or frames not exc. 1.5 sqm each (without taking off shutters from the frames) complete all as specified and as directed by Engineer in charge.
Material and Labour for second class hard wood plain solid, straight Chowkats and frames wrought framed rebatted on the solid, rounded or chamfered put together with glue, pinned at joints complete all as specified and as directed by Engineer in charge.
Supply and fix factory made Plain, framed, panelled shutters (any number of panels) of Second class Hardwood, with panels of timber flat on both sides (feather edged), or of veneered particle board medium density, wood particle board with commercial face veneers, supplied and fitted to chowkats, thickness of shutter 30mm, complete all as specified and as directed by Engineer in charge.
Supply and fix for factory made solid panel PVC moulded door shutter, 28 to 30 mm thick (stiles) with 2,4 or 6 raised panel design 2mm thick 3D wood grain moulded PVC sheet polyurethane painted on the front face & 2mm prelam PVC sheet on back face complete all as specified and as directed by Engineer in charge.
Supply and fix 35mm thick plain factory made second class hard wood skeleton shutters,open rebated and prepared to receive glass, guage etc (without sash bars) edges of framing plain, chamfered or rounded, fitted with cut and mitered bead for securing glass etc... with size of member of shutters complete all as specified and as directed by Engineer in charge.
Cutting holes in brick walls built in cement mortar or cement lime mortar and stone walls built in lime mortar, depth of embedded portion of holdfasts or lugs measured from the face of the jamb into the wall exc half brick but Not exc. one brick complete all as specified and as directed by Engineer in charge.
Supply and fix hold fasts and similar small articles confirming to Fe-290 Gde-E-165, complete all as specified and as directed by Engineer in charge.
Supply and fix 125 mm Extruded aluminium alloy handles, fabricated type, anodised complete all as specified and as directed by Engineer in charge.
Supply and fix 150 mm Extruded aluminium alloy handles, fabricated type, anodised complete all as specified and as directed by Engineer in charge.
Supply and fix 100 mm Butt hinges, type C-21, extruded aluminium alloy with galvanised mild steel hinge pin, anodised and fixed, complete all as specified and as directed by Engineer in charge.
Supply and fix Aluminium anodised, barrel tower bolts of extruded section and fixed, 200mm long, complete all as specified and as directed by Engineer in charge.
Supply and fix Aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy and fixed, 300mm long, complete all as specified and as directed by Engineer in charge.
Material and Labour for Aluminium powder coated (minimum thickness of powder coating 50 micron) frame for doors, windows, ventilators with one or more rebates including joining cleat for fixing etc. complete all as specified and as directed by Engineer in charge.
Material and Labour for Aluminium powder coated (minimum thickness of powder coating 50 micron) window and ventilator shutters, side hung type without sash bars, aluminium sections weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws, anodised aluminium fittings such as peg stays 150mm long (1 no.). hinges type B-21 100mm long (2 no.) suitable handle (1 no.) complete all as specified and as directed by Engineer in charge.
Supply and fix Sheet glass 4mm thick, ordinary quality, fixed with oil putty or with glazing clips, in square n exc 0.5 sq. m each pane complete all as specified and as directed by Engineer in charge.
Supply and fix Aluminium alloy wire cloth, 0.45 mm nominal dia of wire and average width of aperture 1.40mm and fixed with aluminium wire staples complete all as specified and as directed by Engineer in charge.
Dismantling framed work such as grills grating etc complete all as specified and as directed by Engineer in charge.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified and as directed by Engineer in charge.
Material and Labour Glazed ceramic coloured tiles in vertical surface 350x 250x 7 mm/ 450X 350X 7 mm thick, set and jointed in neat cement slurry and pointed in white or coloured cement to match over 15 mm thick backing plaster in CM (1:3) complete all as specified and as directed by Engineer in charge.
Material and Labour non skid ceramic coloured tiles (300X300X7mm) thick in floors etc... set and jointed in neat cement slurry and pointed in white or coloured cement to match over 20 mm thick screed bed in CM (1:4) complete all as specified and as directed by Engineer in charge.
Material and Labour for joint free, coloured, rectified ceramic tiles of size (600x600mm), thickness not less than 8 mm, conforming to IS-15622 with approved make / pattern and colour borders, in floors, set and jointed in neat cement slurry and pointed in white or coloured cement to match over 20 mm thick screed bed in CM (1:4) complete all as specified and as directed by Engineer in charge.
Demolition of reinforced cement concrete as in roofs, floor, chajjas, fins, beams and similar suspended work all, reinforcement cut as required to facilitate demolition, complete all as specified and as directed by Engineer in charge.
Material and Labour Mild steel TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips and including embedding reinforcement bars into exisiting RCC beams, complete all as specified and as directed by Engineer in charge.
Material and Labour Mild steel TMT bars 6mm to 8mm dia , cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and as directed by Engineer in charge.
Material and Labour for formwork to challah hoods, chajjas, lintels, fins, troughs and similar items including edges, rough finished surfaces of concrete, Flat complete all as specified and as directed by Egineer-in charge.
Material and Labour for reinforced cement concrete nominal (1:1.5:3) Type A1 using 20mm graded aggregate in chajjas, fins, fascia etc. Including use of concrete repair chemical/ latex, Pidicrete URP 301 (Make: Dr. Fixit) and embedding/ Hooking new reinforcement complete all as specified and a directed. Note: (a) Quality and mixing of concrete repair chemical/latex shall be as per Manufacturers instruction and the rates quoted are deemed to include for the same. (b) Reinforcement shall be measured and paid separately.
Material and Labour for reinforced cement concrete nominal mix (1: 1.5 : 3), Type A1, using 20 mm graded aggregate in Beams, cantilevers, bressummers, lintels over 1.5m span, Including embedding new reinforcement to existing concrete all as specified and as directed by Engineer in Charge.
Material and Labour Providing, cement concrete in roof kerbs or mud stops, rounded or chamfered on edges, type B0, PCC (1:2:4) using 12.5 mm graded aggregate all as specified and as directed by Engineer in Charge.
Demolition of Precast cement concrete solid blocks masonry built in cement mortar complete all as specified and as directed by Engineer in Charge.
Material and Labour for Precast cement concrete solid blocks masonry type C1 (1:3:6) using 20 mm graded aggregate, exceeding 10 cm in width and setting in cement mortar (1:6) all as specified and as directed by Engineer in Charge.
Taking down cement or cement lime plaster, any description on brick or stone walls, etc. including raking out joints, hacking for key, scrubbing down with water, etc. all as specified and as directed by Engineer in charge. (Note: The work to be carried out by providing necessary scaffolding)
Material and Labour for rendering 10mm thick on fair faces of brick work or concrete surfaces in CM (1:6) and finished even and smooth without using extra cement complete all as specified and as directed by Engineer in Charge.
Material and Labour for rendering 5mm thick in CM (1:4) with using water proofing compound over 10 mm thick rendering in CM (1:6) on external surfaces of block masonry, finished even and smooth without using extra cement complete all as specified and as directed by Engineer in Charge. (Note: the work to be carried out by providing necessary scaffolding )
Supply only integral water proofing compound
Material and Labour for applying 1mm thick wall care putty on newly plastered surface of walls all as specified and as directed by Engineer in Charge.
Material and Labour for complete removal of existing treatment on walls and applying two coats of antifungal exterior weather proof emulsion paint over a coat of alkali resitant primer complete all as specified and as directed (Note: the work to be carried out by providing necessary scaffolding)
Material and Labour for preparation of newly plastered wall surfaces and applying two coats of antifungal exterior weather proof emulsion paint over a coat of alkali reistant primer complete all as specified and as directed by Engineer in charge. (Note: the work to be carried out by providing necessary scaffolding)
Material and Labour for preparation of newly plastered and putty finished surfaces of wall and applying two coats of oil bound acrylic distemper over a coat of alkali resistant primer complete all as specified and as directed by Engineer in Charge.
Material and Labour for preparation of old treated surfaces of wall and applying one coat of oil bound acrylic distemper complete all as specified and as directed by Engineer in Charge.
Material and Labour preperation of old decorated surfaces of ceiling and applying one coat of white wash complete all as specified and as directed by Engineer in Charge.
Supply and fix in repairs, Fancy type Bib taps, cast copper alloy with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule and fixed, Bore dia of pipe 15mm complete all as specified and as directed by Engineer in Charge.
Supply and fix in repairs, Fancy type Stop valves, chromium plated, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed, Bore dia of pipe 15mm complete all as specified and as directed by Engineer in Charge.
Supply and fix in repairs, Fancy type Stop valves, chromium plated with long shank and cup (concealed type), screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed, Bore dia of pipe 15mm complete all as specified and as directed by Engineer in Charge.
Supply and fix in repairs PVC flushing cistem 10 ltr capacity, high or low level, including brackets etc... all as specified and as directed by Engineer in charge.
Supply and fix in repairs, Fancy type Pillar taps, cast copper alloy, with capstan heads, chromium plated, screwed down high pressure, with or without lettered 'Hot' or 'Cold' with long screwed shanks and fly-nuts, screwed for iron pipe and fixed, Bore dia of pipe 15mm complete all as specified and as directed by Engineer in Charge.
Supply and fix PVC connections 15mm size with PTMT nuts of length 600mm complete all as specified and as directed by Engineer in Charge.
Supply and fix in repairs swivel shower rose of PTMT, any colour, for fixing with 15 mm pipe including shower arm 15mm size, 195 mm long with bend of 45 degrees with flange of PTMT, any colour, complete all as specified and as directed by Engineer in Charge.
Taking down GI tubing 15 mm dia with connections complete all as specified and as directed by Engineer in Charge.
Taking down GI tubing 20 mm dia with connections complete all as specified and as directed by Engineer in Charge.
Supply and laying of CPVC 20 mm outer dia of pipes, SDR 11 & plain CPVC SDR 11 fittings on walls/ceiling or laying in floors complete all as specified and as directed by Engineer in Charge.
Supply and laying of CPVC 25 mm outer dia of pipes, SDR 11 & plain CPVC SDR 11 fittings on walls/ceiling or laying in floors complete all as specified and as directed by Engineer in Charge.
Taking down PVC pipes of any size including all fittings,heads,shoes,bends,swan-necks,etc and removng from the site, complete all as specified and as directed by Engineer in Charge.
Supply and fix 110 mm bore PVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in trenches or in floors or fixed to walls, including necessary fittings, complete all as specified and as directed by Engineer in Charge.
Supply and fix 75 mm bore PVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in trenches or in floors or fixed to walls, including necessary fittings complete all as specified and as directed by Engineer in Charge.
Material and Labour PVC (SWR) floor trap, plain with grating including jointing with solvent cement, Diameter of outlet 75mm, complete all as specified and as directed by Engineer in Charge.
Material and Labour PVC (SWR) gully trap 125/110 mm, setting and jointing with solvent cement complete all as specified and as directed by Engineer in Charge.
Supply and fix PVC (SWR) vent cowl, Bore 110mm dia, complete all as specified and as directed by Engineer in Charge.
Supply and fix PVC (SWR) vent cowl, Bore 75mm dia, complete all as specified and as directed by Engineer in Charge.
Supply and fix in repairs Vitreous china wash down water closet pan (pedestal pattern),white (excluding fixing bolts,flushing cistern and flush pipe complete all as specified and as directed by Engineer in Charge.
Material and Labour for providing 75mm thick PCC (1:2:4) type B2 (using 40mm graded stone aggregates) as in plinth protection finished even and smooth without using extra cement, including providing dummy joints at 2 meter center to centre and filling with sealing compound, complete all a specified and as directed by Engineer in Charge.
Material and Labour for preparing new surfaces of wood or wood based material exc 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer, complete all a specified and as directed by Engineer in Charge.
Supply and fix in repairs vitrious china wash basin white flat back size 550X400 mm excluding taps, waste pipe,chain and plug and porcelain stopper but including brackets, complete all a specified and as directed by Engineer in Charge.
Demolition of cement concrete in any position complete all as specified and as directed by Engineer in Charge.
Material and Labour for providing PCC, (1:2:4), type B-2 (using 40mm graded stone aggregates) as in flooring, 100mm thick, finished fair and even without using extra cement but with impression while the concrete is green all as specified and as directed by Engineer in charge.
Material and Labour for providing PCC, type B-1, (1:2:4) (using 20mm graded aggregate) 40 mm thick, as in roof padding concrete, finished fair and even all as specified and as directed by Engineer in charge.
Supply and laying APP modified polymeric water proofing membrane (torch applied) of 3.60 kg/sqm , minimum 3mm thick, reinforced with non-woven polyester matt weighing not less than 160 gms/Sqm, laid over roof surface with 100mm overlap and 150 mm end lap, including on vertical surfaces of fins, sealing complete with thermo fusion torch application over a tack coat of hot bitumen @ 1.2 kg/sqm, bitumen grade 85/25 over compatible bitumen primer at the rate of 0.25 Kg/Sqm including cleaning surfaces and subsequently one coat of hot blown bitumen grade 85/25 @ 1.2 Kg/sqm applied over water proofing membrane and finally one coat of solar reflective bituminous aluminium paint applied @ 0.10 Kg/Sqm as surface finish, including taking down the existing treatment, complete all as per manufacturers instructions and as specified and as directed by Engineer in Charge.
Supply and fix rotational moulded polythene water storage, triple layered (cylindirical vertical with closed top) hoisting, fixed in position and connecting pipes, capacity 500 ltrs, including dismantling of old water tank and taking into credit, complete all as specified and as directed by Engineer in Charge.
Taking down carefully existing aluminium/copper point wiring on batten or in PVC conduit or in MS conduit with GI earth wire etc (for light, fan, socket or power ) complete and making good the disturbed surfaces of walls, Floors, ceilings etc to match with existing complete all as specified and as directed by Engineer in charge.
Taking down carefully by unscrewing from boards/outlet boxes, fittings and fixtures such as switches, sockets ,ceiling roses, lamp holders, brackets, ceiling fittings, bulk head fittings, tube light fittings,ceiling fans ,exhaust fans and regulators ceiling rose etc complete all as specified and as directed by Engineer in charge.
Material and Labour for Point wiring with PVC insulated unsheathed and multistranded copper conductor cable ISI marked, 1100 volt grade. FRLS of size 1.5 Sqmm drawn in and including concealed PVC rigid conduite of size not less than 20mm dia with modular metal flush box concealed and modular white plates with frame of suitable size as required at site with PVC insulated unsheathed stranded copper conductor of size 1.5 Sqmm as earth wire connected common earth dolly as specified for one light point controlled by one switch for light/Fan complete all as specified and as directed by Engineer in charge. Note : (i) Rate quoted should include cost of modular metal flux box concealed and making good to walls (ii) Rate quoted is deemed to include for modular white cover plate with frame. (iii) Necessary blank plate as required at site.
All as per item No 85 here in before but one 3 pin 5 amps switch sockets on same board complete all as specified and as directed by Engineer in charge.
All as per item No 85 here in before but one 3 pin 5 amps switch sockets on independent board complete all as specified and as directed by Engineer in charge.
All as per item No 85 here in before but with cable size 2.5 Sqmm and 2.5 Sqmm as earthwire for 3/5 pin socket out let independent, 15/16 Amps complete all as specified and as directed by Engineer in charge.
Material and Labour Submain wiring with Two runs of 2.5 sqmm size multi stranded copper conductor PVC insulated unsheathed cable (FRLS) in and including PVC rigid non metalic conduit and one run of PVC insulated cable of size 2.5 sqmm size multi stranded copper conductor PVC insulated and unsheathed for continious earth wire including complete all as specified and as directed by Engineer in charge.
Supply and fix modular Switch and socket combination 3 pin 5 Amp AC 230 Volts flush type complete all as specified and as directed by Engineer in charge.
Supply and fix modular Switch and socket combination 6 pin 15 Amp AC 230 V complete all as specified and as directed by Engineer in charge.
Supply and fix modular type switch 6 Amp single pole one way complete all as specified and as directed by Engineer in charge.
Supply and fix Ceiling rose, three terminals, polycarbonate, isolated body complete all as specified and as directed by Engineer in charge.
Supply and fix modular type Socket, 6A - 2/3 pin combined 2 module complete all as specified and as directed by Engineer in charge.
Supply and fix in replacement modular Fan step Regulator, 120 Watt, 2 module, hum free complete all as specified and as directed by Engineer in charge.
Supply and fix Surface and wall mounted LED 20Watt 4ft long batten, extruded aluminium housing provided for efficient heat dissipation with polycarbonate diffuser & integrated electronic driver with industrial grade heavy duty driver having THD<10% suitable pre wired and testing including all connections complete all as specified and as directed by Engineer in charge. Make: Havells Cat Part No. ENDURALINEARNEOBS20WLED865SPCWH or equivalent in Philips/Bajaj/Wipro/Crompton/Osram/Luker as approved by GE
Supply and fix ceiling fan 1200 mm sweep complete with necessary fixing accessories such as clamps,nuts,bolts ,cottor pins etc. and testing all as specified and as directed by Engineer in charge.
Supply and fix in replacement exhaust fan 300 mm sweep made of synthetic material complete with necessary fixing accessories including civil works and testing complete all as specified and as directed by Engineer in charge.
Supply and fix in replacement sheet metal enclosure with two pin socket , chain plug cover with MCB SPN of 20 Amp capacity with alignment 10 KA, ‘B’ series complete all as specified and as directed by Engineer in charge.
Supply and fix Surface and wall mounted LED 10 Watt 2Ft long batten, extruded aluminium housing provided for efficient heat dissipation with polycarbonate diffuser & integrated electronic driver with industrial grade heavy duty driver having THD<10% suitable pre wired and testing including all connections complete all as specified and as directed by Engineer in charge. Make: Havells Cat Part No. ENDURALINEARNEOBS10WLED865SPCWH or equivalent in Philips/Bajaj/Wipro/Crompton/Osram/Luker as approved by GE
Supply and fix LED 24 W building security light luminaire epoxy coated,energy saving and environmental friendly long life LED street light made up of pressure die cast aluminium housing with high efficient LED as lighting source and PC cover having TOP Opening seperate driver compartment with IP66 protection and impact resistance of IK07 complete all as specified and as directed by Engineer in charge. Make: Havells Cat Part No. ENDURAPEARLSL30WLED757SASYTOPCMP or equivalent in Philips/Bajaj/Wipro/Crompton/Osram/Luker as approved by GE
Supply and fix in replacement MCB SPN 40 Amp 240 V , 50 Hz, complete all as specified and as directed by Engineer in charge.
Supply and fix in replacement MCB SP 5 to 30 Amp, 240 V, "B" Series, complete all as specified and as directed by Engineer in charge.
Supply and fix in replacement MCB DB SPN 8 way with 200 Amp copper bus bar double door type complete all as specified and as directed by Engineer in charge.
Material and Labour for Earthing complete with galvanised steel plate electrode 600 x 600 x6mm thick buried directly in ground vertically to a depth not less than 2.25mtr below ground level with top edge of earth plate at a depth 1.5mtr below ground level connected with galvanised steel strip of size 25 x 4 mm up to DB/main switch as earthing lead by means of nuts bolts and washers of galvanized iron protected by 15mm dia light grade GI tubing, funnel, wire mesh, 20mm bore GI tubing medium grade watering pipe, including concrete pit in PCC 1:3:6 type C-1, precast RCC (1:2:4) type B-1 cover slab of size 350x350x50mm reinforced with 8mm dia TMT bars @ 15cm c/c in both ways and 10mm dia MS handle of suitable size, charcole and slat in alternate layers necessary excavation and earth work in soft/loose soil all as shown in Electrical plate No. 3 of SSR part-I and testing complete including taking down of unserviceable materials of old earthing complete all as specified and as directed by Engineer in charge.
FUTURE ONE FACILITY MANAGEMENT
SKY CONSTRUCTIONS
STANDARD ENGINEERING
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .