| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹22.8 LAccepted-AOC FLAT NO 10 S NO 98 PLAT NO 78 SAI SAYAJI PARK A RIGHT BHUSARI COLONY KOTHRUD PUNE 411 038 | PUNE | MAHARASHTRA | 411038 | 1 | Accepted-AOC L1 | |
| 2 | 2₹26.4 L+₹3.6 L (15.8%)Rejected-Finance 18969 A 1 SHRI GURU TEG BAHADUR NAGAR BIBIWALA ROAD STREET NO 15 BATHINDA 151001 | BATHINDA | BATHINDA | PUNJAB | 151001 | 2 | Rejected-Finance Not Lowest | |
| 3 | 3₹27.5 L+₹4.7 L (20.7%)Rejected-Finance | 3 | Rejected-Finance Not Lowest | |
| 4 | 4₹27.7 L+₹4.9 L (21.3%)Rejected-Finance | 4 | Rejected-Finance Not Lowest | |
| 5 | 5₹31.2 L+₹8.3 L (36.6%)Rejected-Finance INDEX NO B 33 NC R O KRALPORA DISTT BUDGAM SRINAGAR J K 190019 | SRINAGAR | BUDGAM | JAMMU AND KASHMIR | 190019 | 5 | Rejected-Finance Not Lowest |
Tender Value
₹28.3 L
EMD Value
₹56,600
Closing Date
24 Feb 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
CWE Bathinda
HQ CWE Bathinda
PROVN OF GUARD ROOM AT OLD SHIVAJI ENCLAVE AND NEAR MANOJ PANDEY GATE OF ARMED REGMT AT BATHINDA MIL STATION UNDER GE (N) BATHINDA
2021_MES_460427_4
CWE BTD 8216/E8
Open Tender
Civil Works
Lump-sum
180 days
Bathinda
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
GE (North) Bathinda
₹56,600
Yes
10 Mar 2022
28 Jan 2022
26 Feb 2022
28 Jan 2022
24 Feb 2022
5 Feb 2022
28 Jan 2022 - 4 Feb 2022
60 days
Amount
SCHEDULE 'A' PART-I (BUILDING AND STRUCTURE WORKS)
Lump sum price worked out by the Contractor for “Building / Structure Work” as listed in Schedule ‘A’ Part - I Above / Below the lump sum price inserted by the MES against this Schedule under Col 6.
SCHEDULE 'A' PART-II (INTERNAL WATER SUPPLY)
Lump sum price worked out by the Contractor for “Internal Water Supply Works” as listed in Schedule ‘A’ Part -II Above / Below the lump sum price inserted by the MES against this Schedule under Col 6.
SCHEDULE 'A' PART-III (SECTION-'A') (INTERNAL ELECTRIC SUPPLY)
Lump sum price worked out by the Contractor for “Internal ElectricSupply Works” as listed in Schedule ‘A’ Part -III (Section-'A') Above / Below the lump sum price inserted by the MES against this Schedule under Col 6.
SCHEDULE 'A' PART-III (SECTION-'B') (INTERNAL ELECTRIC SUPPLY)
S & F 18/20 watt Retro LED tube light fitting, wall/surface mounted, IP 20 protection, conforming to IS 16106/IS 16107, minimum 6000K batten decorative type 4 feet long polycarbonate body, white, in built LED driver, power factor>0.95 , Make – all as per Crompton Cat Part No. DMLN1LT8-16 (for batten) and Cat part No. LT8-20-865-2 (for tube light) OR Equivalent model of any make given in Appdx 'B' including 18/20 watt tube rod or equivalent model of any make given in Appx 'B' connecting to electric point by using PVC insulated twin core copper conductor cable of suitable size all as specifies and as directed.
S & F energy efficient LED street light fitting of 25 Watt with PDC aluminium body and clear glass with lens for wide beam distribution, top maintainable type with IP-66 degree of protection, PF > 0.95 with voltage range 140 to 270 Volt, fitting should be provided with inbuilt 5 KV minimum surge protection, short circuit and over voltage protection facility for Driver and fitting including 25 watt LED lamp with GI brackrt - 01 No, MS clamp-02 Nos suitable for walls/ columns and making electrical connection with providing of 1.50 metre long twin core round copper conductor cable of suitable size and testing complete all as per SYSKA cat part No. SSK-SLF-CF-25W-WL or equivalent model of any make given in Appx 'B', Cat Part No. as approved by GE complete all as specified.
S & F LED mirror light fitting of 09/10 watt, 6000K, linear & compact with decorative grey end caps, polycarbonate body and ribbed opal diffuser complete including 07 watt tube rod make all as Model No LCTL-9-CDL of Crompton or equivalent model of approved make from list of make given in Appx 'B' including connecting to electric point by using PVC insulated twin core copper conductor cable of suitable size all specified and as directed.
S & F Exhaust fan 300mm sweep . Including electrical connection by providing twin core round copper conductor of suitable size complete all as specified. Make – Havells / Crompton / Bajaj
S & F Ceiling fan 1200mm sweep . BEE 5 star rated including electrical connection by providing twin core round copper conductor of suitable size complete all as specified. Make – Havells / Crompton / Bajaj
S & F only LED Bulb 9 Watt complete all as specified. Make – Havells / Crompton / Bajaj
M & L earthing complete with galvanised steel earth plate electrode 600 x 600 x 6 mm thick burried directly in ground to depth of pit not less than 2.25 m below normal ground level with top edge of the plate not less than 1.5 m below normal ground level surrounded from all sides by 15 cm thick packed layer of charcoal / coal dust and common salt filling in alternate layers and connected to galvanised earth lead wire 4 mm dia by means of bolts, nuts, check nuts and washers of GI or steel including GI protection pipe 15mm dia light grade upto the extent of 7.5 metre and connecting to earthing test point, main switch board including GI pipe 20 mm dia light grade for watering, MS funnel and bringing out the watering pipe upto 30 cm above the normal ground level plugged at top including all fitting including PCC earth pit with PCC 1:2:4 type B-1 using 20mm graded stone aggregate and RCC pit cover including necessary earthwork and excavation in any type of soil complete all as specified as shown in electrical plate No 3 of SSR Part-I and testing on completion. Note :- (a) PCC chamber shall be constructed at least 1.5 m away from earth pit. Pipe for watering shall be provided in slanting manner. (b) 4mm dia GI wire and 15mm dia light grade GI protection pipe upto 7.5 metre shall deemed to be included in quoted rate.
SUB TOTAL
SCHEDULE 'A' PART-IV (EXTERNAL ELECTRIC SUPPLY)
Lump sum price worked out by the Contractor for “External Electric Supply Works” as listed in Schedule ‘A’ Part -IV Above / Below the lump sum price inserted by the MES against this Schedule under Col 6.
SCHEDULE 'A' PART-V (SEWAGE DISPOSAL)
Lump sum price worked out by the Contractor for “Sewage Disposal Works” as listed in Schedule ‘A’ Part -V Above / Below the lump sum price inserted by the MES against this Schedule under Col 6.
SCHEDULE 'A' PART- VI (ROAD AND PATH)
Lump sum price worked out by the Contractor for “Road and path” as listed in Schedule ‘A’ Part -VI Above / Below the lump sum price inserted by the MES against this Schedule under Col 6.
SCHEDULE 'A' PART- VII (SECTION-'A') (EXTERNAL WATER SUPPY)
Lump sum price worked out by the Contractor for “External Water Suppy” as listed in Schedule ‘A’ Part -VII Above / Below the lump sum price inserted by the MES against this Schedule under Col 6.
SCHEDULE 'A' PART-VII (SECTION-'B') (EXTERNAL WATER SUPPY)
M & L Cutting into existing GI / CI Pipes line up to 100mm dia and inserting Tee , Tail Pieces , Socket, as required , and making new connection including excavation antd earth work if necessary all as specified and as directed.
SUB TOTAL
SHARDA ENTERPRIES
K L JINDAL AND CO.
RAMA AUTOS
G N CONSTRUCTIONS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .