| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹59.9 LAccepted-AOC | L1 | Accepted-AOC lowest bidder | |
| 2 | L2₹61.9 L+₹1.0 L (1.68%)Rejected-AOC | L2 | Rejected-AOC Being other than lowest | |
| 3 | L3₹63.4 L+₹2.6 L (4.21%)Rejected-AOC 7TH MILE UPPER SHILLONG P O NONGLYER SHILLONG MEGHALAYA | EAST KHASI HILLS | MEGHALAYA | 793009 | L3 | Rejected-AOC Being other than lowest | |
| 4 | L4₹65.4 L+₹4.6 L (7.56%)Rejected-AOC | L4 | Rejected-AOC Being other than lowest | |
| 5 | L5₹65.4 L+₹4.6 L (7.57%)Rejected-AOC | L5 | Rejected-AOC Being other than lowest |
Tender Value
Refer Docs
Closing Date
27 Dec 2022, 6:00 pmClosed
CWE (AF) Chandigarh
HQ CWE (AF) Chandigarh PIN-160003
SPECIAL REPAIRS TO CERTAIN BUILDINGS IN DOMESTIC AREA AT AF STATION AMRITSAR
2022_MES_564324_1
CWE/AF CHD/ASR/T-35/2022-2023
Open Tender
Civil Works
Item Rate
180 days
A
As per NIT
8 documents required · 8 mandatory
₹1,000
AGE(I)(AF) Amritsar
Exempted
24 Feb 2023
21 Nov 2022
3 Jan 2023
21 Nov 2022
27 Dec 2022
13 Dec 2022
Amount
Building Work
Dismantling brick tiles or terracing tiles, single layer on roof including segregating and stacking serviceable brick tiles and removal of unserviceable brick tiles / brick bats and rubbish outside defence land, complete all as specified and directed.
Demolition of mud phuska on roofs, any thickness, including plaster and leeping plaster and bottom layer of polythene film if any, including removal of retrieved material outside defence land, complete all as specified directed.
Demolition of cement concrete ( unreinforced) of any description and in any position not otherwise specially provided for including removal of debries out of defence land complete all as specified and directed
Material and labour for roughening surfaces of old concrete slab by picking/wire brush, sweeping clean and washing down with water to remove dust etc. and brushing neat cement slurry @ 3.00 Kg/Sqm on roof surface, and removal of rubbish outside defence land complete all as specified and directed
Material and labour for average 50mm thick plain cement concrete (1:2:4) type B-1 using 20mm graded crushed stone aggregate using water proofing compound as per manufacturer's instructions, as in padding on roof, in required thickness to maintain desired slope, finished even and fair to receive tiles/ APP membrane, complete all as specified and directed. Note:- Supply only integral water proofing compound will be measured and paid for separately.
Material and Labour for PCC (1:2:4) type B-1, using 20mm graded crushed stone aggregates, as in coping, roof padding, roof kerb, mud stops, kneelers, apex stones, bed plates,benching, water trough etc including weathering, slightly rounded or chamfered angle and throating, including necessary form work, complete all as specified and directed.
Material & labour for Cleaning and preparation of roof (RCC/Brick tiles/Cement concrete) surfaces and made free of dirt, foreign particles, laitance, followed by grinding all protrusions to make surface modulated. Thereafter, inspection for cracks on the surface caused by thermal expansion/contraction, and repairing the cracks after making “V” groove with suitable cutter machine, filled with Repair Morter/General Purpose Grout in the proportions as recommended by manufacturer, supplying and applying High performance Hybrid Polyurea waterproofing coating spray/hand applied liquid membrane with following specifications: (a) Elongation of range 400%-600% (b) Tensile strength of 8-12 N/mm2 (c) Crack bridging ability of 3.00- 4.00 mm (d) Hardness (Shore’A’, ASTM D2240) of range 50-70 The application shall include final base preparation, epoxy primer application in rato 1:1 (resin:hardner) with 100% water dilution and application of Hybrid ployurea in two coats in 6 hrs interval to achieve total min thickness 1 to 1.50 mm. The application/treatment shall be carried out by authorised rep of approved specialist firm/manufacturer. Make- SIKA/FOSROC/Asian Paints/Berger. Note:- The defect liability period of water proofing treatment to RCC roof slab including sunken floors shall be 10 years and the contractor shall be responsible to keep the entire building(s) free from leakage/seepage for a period of 10 years after certified date of completion. The contractor may obtain a similar guarantee from the specialist firm engaged by him for the purpose.
Taking down cement plaster of any description on brick walls or concrete surfaecs etc. including raking out joints, hacking for key, scrubbing down with water for buildings upto double storey height complete all as specified and directed .
M&L for rendering 10mm thick cement plaster in cement mortar (1:3) on concrete surfaces as in ceiling, finished even and smooth without extra cement complete all as specified.
Material and labour for rendering 15mm thick in cement mortar (1:4), using water proofing compound as per manufacturer's instructions, on brick/concrete surfaces of walls, finished even fair , complete all as specified and directed. Note :- 1. Supply only water proofing compound will be measured and paid for separately.
Material and labour for rendering 20mm thick cement plaster in two layers (15 mm + 5 mm) on concrete surfaces in cement mortar (1:4) in patches at columns, chajja, canpoy and soffits with & including supply and fixing chicken wire mesh, including necessary scafolding arrangement as required at site, complete all as specified and directed.
M&L for rendering cement plaster 15 mm thick in cement mortar (1:6) on fair faces of brick work or concrete surfaces, finished even and smooth without using extra cement complete all as specified and directed.
Material and labour for preparation of new plastered ceiling surfaces and applying three coats of white wash, complete all as specified and directed.
Material and labour for complete removal of existing treatment & preparation of old plastered for ceiling surfaces and applying two coats of white wash complete all as specified and directed.
Material and labour for preparation of new wall surfaces and applying 1mm thick Birla/JK wall care putty to obtain smooth regular/even finish and applying two coats of oil bound distemper, complete all as specified and directed
Material and labour for complete removal of existing treatment & preparation of old plaster surfaces for wall any description two coats of oil bound distemper with 1mm wall care putty complete all as specified and directed
Material and labour for preparing new plastered surfaces on walls and applying Premium Acrylic Smooth exterior paint with Silicon additives of required shade, (Two coats shall be applied @ 1.43 ltr/10 sqm over and including 1mm wall care putty incl priming coat of exterior primer applied @ 2.20 kg/10 sqm), complete all as specified and directed.
Material and labour for complete removal of existing treatment of wall and applying Premium Acrylic Smooth exterior paint with Silicon additives of required shade, (Two coats shall be applied @ 1.43 ltr/10 sqm over and including 1mm wall care putty incl priming coat of exterior primer applied @ 2.20 kg/10 sqm), complete all as specified and directed.
Supply only integral water proofing compound, complete all as specified and directed.
Dismantling floor hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises including removal of debries out of defence land complete all as specified and directed.
Material and labour for Non skid matt finish jointless coloured ceramic tiles 7 to 8 mm thick (square/rectangular ) area each tiles exceeding 0.18 sqm but not exceeding 0.38 sqm as in floor etc set and jointed in neat cement slurry @ 3Kg/Sqm and pointed in white or coloured cement to match over and including 15 mm thick screed bed or bedding layer in C:M 1:6 complete all as specified and directed.
All as per item No 1.21 above but as in dado, riser & skirting over & incl 10mm thick rendering in CM 1:4
Material and labour for first quality coloured glazed ceramic tiles of size 350 x 250 x 7mm /450x350x7 mm thick as in skirting, dado, set and jointed in neat cement slurry, over and including 10 mm thick rendering of cement mortar (1:4), including pointing in white cement with pigment to match the shade of tiles, complete all as specified.
Material and labour for Non skid jointless coloured ceramic tiles 7 to 8 mm thick (square/rectangular ) area each tiles exceeding 0.11 sqm but not exceeding 0.18 sqm as in floor etc set and jointed in neat cement slurry @ 3Kg/Sqm and pointed in white or coloured cement to match over and including 15 mm thick screed bed or bedding layer in C:M 1:6 complete all as specified and directed.
Material and labour for 17-19 mm thick Granite black/brown in colour (of any type), (table rubbed and polished), machine cut, as on cooking platforms, window cills, steps and like, set in neat grey cement slurry @ 3Kg/Sqm, laid over and including 15mm thick bedding layer in cement mortar (1:4), including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite, complete all as specified and directed.
Material and Labour for machine cut Kota stone flooring 18-20mm thick, over 20 mm thick cement mortar (1:4) screed bedding base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab rubbing and mirror polishing, complete all as specified and directed.
Material and Labour for machine cut Kota stone 10-15 mm thick as in riser of steps, dado, skirting and pillar, vertical surface, including taking down cement plaster on walls and raking out joints, hacking for key, scrubing down with water etc and rendering 10 mm thick on other than fair face of brick or concrete suface in CM 1:4, complete all as specified and directed
Mirror polishing on marble/granite/Kota stone/stone work where ever required (verticle/horizotal surface) to give high gloss finish complete all as specified and directed.
Material and Labour for Vitrified chequred tiles light shade 9-10 mm thick (squqre/rectangular), polished, area of each tile not exc 0.11 sqm in floors etc, set and jointed in neat cement slurry and pointed in white or coloured cement to match, over and including 15 mm thick screed bed or bedding layer in CM 1:6 for laying floor finishes, complete all as specified and directed
Demolition of reinforced concrete of any description and in any position not otherwise specifically provided for, in ground floor, Ist floor, in isolated wall/windows, chajjas, balconies, precast cover slab etc and removing rubbish out sie MoD land, complete all as specified and directed.
Demolition of brick masonry work built in cement mortar including all quoins, arches, pillars, staging etc. and removal of rubbish outside MOD land, complete all as specified and directed.
Material and labourfor brickwork with using subclass 'B' old size bricks, straight or curved on plan exc 6m mean radius, built in cement mortar (1:6), complete all as specified and directed.
Material and labour for brickwork in half brick thick wall using subclass 'B' old size bricks, straight or curved on plan exc 6m mean radius, built in cement mortar (1:4), complete all as specified and directed.
Material and labour for first quality vitrified ceramic light shade coloured tiles 9-10 mm thick, (square/rectangular), area of each tile exceeding 0.42 Sqm, not exceeding 1.00 Sqm, as in floors etc, set and jointed in neat cement slurry @ 3Kg/Sqm and pointed in white cement mixed with pigment or coloured cement to match the shade of tiles, including screed bed or bedding layer of cement mortar 1:6, 15 mm thick, complete all as specified and directed.
Material and labour for first quality vitrified ceramic light shade coloured tiles 9-10 mm thick, (square/rectangular), area of each tile exceeding 0.42 Sqm, not exceeding 1.00 Sqm, vertical surface, set and jointed in neat cement slurry @ 3Kg/Sqm and pointed in white cement mixed with pigment or coloured cement to match the shade of tiles, including rendering in cement mortar 1:3, 15 mm thick, complete all as specified and directed.
Material and labour for RCC nominal mix (1:2:4), type B-1, using 20 mm graded crushed stone aggregate as in slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like , complete all as specified and directed.
Material and labour for formwork for flat fair finished surfaces of concrete to sides and soffits of lintels, cantilevers, shelves including supports, overhangs, etc also splay between floors and beam, complete all as specified and directed.
Material and labour for Formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; flat fair finished concrete surfaces, not exceeding 200 mm thick (Horizontal or sloping) complete all as specified and directed.
Material and labour for TMT steel bars, 10 mm dia and over , cut to length, bent to shape required including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia complete all as specified and as directed.
Material and Labour for mild steel TMT bars 8 mm dia and over upto 10 mm dia as in stirrups, cut to length, bent to shape required, including cranking, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips complete all as specified.
Taking down chowkats or frames with shutters (without taking off shutters from the frame), not exceeding 1.5 Sqm each and removal, including making good the disturbed surface in CM(1:4) and finishing as per existing specifications and removal of debris outside MOD land, complete all as specified and directed.
Taking down chowkats or frames with shutters (without taking off shutters from the frame), exceeding 1.5 sqm but not exceeding 4 sqm each and removal, including making good the disturbed surface in CM(1:4) and finishing as per existing specifications and removal of debris outside MOD land, complete all as specified and directed.
Supply and fixing solid PVC door frame of size 50mm x 47mm made out of 5mm wood grain PVC sheet reinforced with MS Square tube, supplying and fixing in opening as per specifications, complete all as specified and directed.
Supply and fixing factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of MS tube for top and bottom rails. MS frame shall be covered with heat moulded wood grain prelaminated printed PVC sheet ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail, panelling of wood grain printed PVC sheet to be fitted in the M.S. frame welded/ sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement, supplying and fixing in the frame at site complete all as specified and directed.
Supply and fixing factory made pressed steel frames for doors with two rebates, of size 125mmx60mm, made out of 1.25mm thick sheet, including necessary fixing lugs, hinges, lock strike plate, etc,including back filling of PCC1:3:6 type C-0, and one shop cot of primer, complete all as specified and directed.
Supply and fixing factory made pressed steel frames for doors with single rebate, of size 105mmx60mm, made out of 1.25mm thick sheet, including necessary fixing lugs, hinges, lock strike plate, etc,including back filling of PCC1:3:6 type C-0, and one shop cot of primer, complete all as specified and directed.
Supply and fixing flush shutters 35 mm thick, solid core construction with block board core and plywood face panels commercial type on both sides, both faces covered with decorative wood grain 0.5mm thick sheet, duly provided with 6mm thick Teakwood lipping on edges, fitted to chowkats, complete all as specified & directed.
Supply and fixing second class hard wood 35 mm thick plain, glazed and skelton factory made shutters, open rebated and prepared to receive glass, gauge etc (without shash bars), edges of framing plain, chamfered or rounded, fitted with cut and mitred beads for securing glass etc, sizes of members of shutter as specified in SSR Part I, Section 8, Clause 8.24(a), kiln seasoned and chemically pressure treated , supplied and fitted to chowkats complete all as specified and and directed. Note:- Glass or Wire cloth in panels will be measured and paid separately.
Taking down shutters of any description exceeding 1.0 Sqm but not exceeding 2.0 Sqm each, from chowkhats/frames and removal to store for reuse or credit, complete all specified and directed
Supply and fixing flush shutters 25 mm thick, solid core construction with block board core and plywood face panels commercial type on both sides, one face covered with decorative wood grain 0.5mm thick sheet, duly provided with 6mm thick Teakwood lipping on edges, fitted to chowkats, complete all as specified & directed.
Supply and fixing stainless steel butt hinges of size 100mm, complete all as specified and directed.
Supply and fixing 150 mm long, extruded aluminium alloy handles, fabricated type, anodized, complete all as specified and directed.
Supply and fixing 200 mm long aluminium anodized, barrel tower bolt of extruded section, ISI marked, complete all as specified and directed.
Supply and fixing Aluminium alloy, anodised, sliding door bolts 250mm long, with hasp and staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminium alloy 12mm dia, complete all as specified and directed.
Supply and fixing 50 mm door stopper of aluminium alloy body and tongue, double legs, anodised, with hard drawn steel spring fixed in door, complete all as specified and directed.
Supply and fixing MS 200mm long ordinary helical spring, including rollers and roller plate on wooden or angle iron frame with flat iron and necessary bolt or welding, complete all as specified and as directed.
Supply and fixing Factory made box type steel window with pintol hinges & 2 Nos 150 mm mild steel tower bolts to each shutter, steel handles and with glazing bars, dovetailed or welded in glazed shutter and without glazing bars for wire gauged shutter , including provision of grill, all as per drawing and with one shop coat of zinc chromate primer, complete all as specified and shown on Drawing No CEAF/STD-184-2012 Sheets 1/3, 2/3 & 3/3. Note:- Sheet glass and wire cloth will be measured and paid separately.
Dismantling cross-arms of M.S. channel or angle sections etc. complete and setting aside for re-use within 50m or remove to store, complete all as specified & directed
Supply and fixing framed work such as coolar stand, grills, gratings, etc., with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work con- forming to Fe.290.Gde-E-165, complete all as specified and directed.
Supply and fixing stainless steel wire cloth, 0.36mm nominal dia of wire and average width of aperture 1.40mm fixed to steel frames with stainless steel tacks, or stainless steel wire staples, or fixed to wooden frames with first class hard wood bead, complete all as specified and directed.
Supply and fixing plain sheet glass 3 mm thick, ordinary quality, not exceeding 0.50 Sqm each pane, and glazing with oil putty and securing pins, complete all as specified and directed.
Material and labour, applying two coats of synthetic enamel paint over on new steel surfaces over 10cm width or girth, including preparation of steel surface, complete all as specified and directed.
Material and labour, applying two coats of synthetic enamel paint over and including a coat of red oxide primer, on new steel surfaces over 10cm width or girth, including preparation of steel surface, complete all as specified and directed.
Material and labour for preparation of old steel or iron surfaces over 10cm width or girth not otherwise described and applying two coats of synthetic enamel paint, complete all as specified and directed.
Material and labour applying two coats of synthetic enamel paint over and including a coat of pink primer, on new wooden surfaces over 10cm width or girth, including preparation of wooden surface, complete all as specified and directed.
Material and labour for preparation of old wooden surfaces over 10cm width or girth not otherwise described and applying two coats of synthetic enamel paint, complete all as specified and directed.
Supply and fixing in repairs Stainless steel sink with drainage board made of 1.00 mm thick sheet for kitchen with plugs washers & wastes, including bedding in cement mortar on to dwarf wall or including fixing cantilever brackets and connecting union to pipe overall size 915mmx460mm with bowl size 410mmx330mmx160mm, with and including PVC waste pipe and CP waste coupling 32 mm, complete all as specified directed.
Supply and fixing Vitreous china wash hand basin, white, flat back, size 550mm x 400mm, including brackets and cutting for and pinning in ends of brackets, complete including CP brass waste coupling, PVC waste pipe, brackets & including taking down old and removal of old from site, complete all as specified.
Supply and fixing vitreous china wash down water closet squatt pan, Indian type (Orissa pattern), of size 580mmx440mm, white with integral foot rests (excluding flushing cistern but including CI ‘P’/’S’ trap), set in & jointed with appripriate adhesive/mortar including embedding in concrete including 32mm CP long bend flush pipe suitable for flush cock & jointing with adhesive, and taking out old water closet and removal of debris outside MOD land, complete all as specified and directed.
Supply and fixing in repairs vitreous china wash down water closet (pedestal pattern) white pedestal pan and trap, including connection to drain ( or out going pipe ) and to flushing pipe, antisyphonage pipe, with plastic water closet seat cover white, closed pattern with flat bottom including flushing jet and mild steel chromium plated or aluminised hinging device etc, including 32 mm CP long bend flush pipe suitable for flush cock, complete all as specified and directed.
Supply and fixing vitreous china urinal, full stall type, (back or corner wall type), white, complete including providing and fixing plugs, bedding urinal against wall in cement mortar [1:2], securing urinal to plugs with and including 60 mm long brass screws, pointing around urinal back in cement, including 32 mm dia brass chromium plated waste fittings with long screw shanks and fly nuts, flange end bedded in red lead cement and other end fixed, rubber plug with rings, including CI Brackets, grating and union for discharge pipe, PTMT Urinal spreader, PVC waste pipe, CP screws etc, complete all as specified and as directed.
Supply and fixing Vitreous china urinal partition white of size 310 mm x 700 mm, complete all as specified & directed
Supply and fixing in repairs 32 mm flushing cock, concealed type, cast copper alloy, screwed down, high pressure, fancy type chromium plated, screwed, both ends for iron pipe or for unions and fixed, complete all as specified & directed. Make- Cera Catpart no F8010108 or euivalent in the makes mentioned in Appx 'B'.
Supply and fixing pillar tap long neck, cast copper alloy, chromium plated, fancy type, with capstan head, screwed down high pressure, with or without lettered ‘Hot’ or ‘Cold’ with long screwed shank and fly nuts, screwed for iron pipe 15mm bore dia and fixed to WHB and connections to iron pipe, as in repairs, complete all as specified and directed.
Supply and fixing 450 mm long PVC connection 15 mm size with PTMT nuts, complete all as specified and directed.
Taking up or down existing steel water tubing and connections, 15mm bore for re-fixing or removing from site to store for reuse or credit, including taking down standard fittings, complete all as specified and directed. Note : Cost of cutting chases as required shall be deemed to be included in quoted rate against this item.
Taking up or down existing steel water tubing and connections, 20mm bore for re-fixing or removing from site to store for reuse or credit, including taking down standard fittings, complete all as specified and directed. Note : Cost of cutting chases as required shall be deemed to be included in quoted rate against this item.
Taking up or down existing steel water tubing and connections, 25 or 32 mm bore for re-fixing or removing from site to store for reuse or credit, including taking down standard fittings, complete all as specified and directed. Note : Cost of cutting chases as required shall be deemed to be included in quoted rate against this item.
Taking up or down existing steel water tubing and connections, 40 or 50 mm bore for re-fixing or removing from site to store for reuse or credit, including taking down standard fittings, complete all as specified and directed. Note : Cost of cutting chases as required shall be deemed to be included in quoted rate against this item.
Supply and fixing galvanized steel water tubes 15mm bore, medium grade, with all standard fittings such as bends, elbows, tees etc, concealed/on surface, fixed to walls and ceiling or laid in floors, including making good the chases etc in cement mortar(1:3) after fixing of pipe, complete all as specified and directed.
Supply and fixing galvanized steel water tubes 20mm bore, medium grade, with all standard fittings such as bends, elbows, tees etc, concealed/on surface, fixed to walls and ceiling or laid in floors, including making good the chases etc in cement mortar(1:3) after fixing of pipe, complete all as specified and directed.
Supply and fixing galvanized steel water tubes 25mm bore, medium grade, with all standard fittings such as bends, elbows, tees etc, concealed/on surface, fixed to walls and ceiling or laid in floors, including making good the chases etc in cement mortar(1:3) after fixing of pipe, complete all as specified and directed.
Supply and fixing galvanized steel water tubes 32mm bore, medium grade, with all standard fittings such as bends, elbows, tees etc, concealed/on surface, fixed to walls and ceiling or laid in floors, including making good the chases etc in cement mortar(1:3) after fixing of pipe, complete all as specified and directed.
Supply and fixing galvanized steel water tubes 40mm bore, medium grade, with all standard fittings such as bends, elbows, tees etc, concealed/on surface, fixed to walls and ceiling or laid in floors, including making good the chases etc in cement mortar(1:3) after fixing of pipe, complete all as specified and directed.
Supply and fixing bib tap, cast copper alloy, fancy type, chromium plated, with capstan head, screwed down high pressure, screwed for iron pipe or for brass ferrule 15mm bore dia, fixed as in repair, including removal of old to store for reuse or for credit, complete all as specified and directed.
Supply and Fixing in repairs Brass chromium plated shower rose 125 mm size with or without swivel joints, fancy type with CP arm concealed type with CP cup including fixing to steel pipe or union 15mm bore, complete all as specified and directed.
Supply and Fixing Towel Rail 600mm long of PTMT fixed with and including chromium plated brass screws and wooden/plastic cleats (Minimum weight 190gms), complete all as specified and directed. ,
Supply and fixing in repairs Soap Dish ccomplete all as specified and directed. Make : Prayag Cat No. BA-45 or equivalent make as per Appx 'B'
Supply and fixing CP peg set of 5 including necessary fixing arrangement, complete all as specified and directed by Engineer - in -Charge.
Supply and fixing stop valve, cast copper alloy, fancy type, long shank and cup (concealed type), chromium plated, screwed down high pressure, screwed for iron pipe or for brass ferrule 15mm bore, fixed as in repair, including removal of old to store for reuse or for credit, complete all as specified and directed.
Supply and fixing in repair 25 mm Ball valves high pressure of PTMT with epoxy coated Aluminium rod & highdensity plastic ball screwed for iron pipe and fixed. (Minimum weight - 455gms), complete all as specified and directed.
Supply and fixing in repairs 15 mm size angle valve of PTMT, any colour high pressure screwed for iron pipes (minimum weight 90 gram), complete all as specified and directed.
Supply and fixing in repairs110 mm bore PVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in trenches or in floors, complete all as specified and directed.
Supply and fixing PVC (SWR) bend any radius for 110 mm bore pipe incl jointing material, complete all as specified and directed.
Supply and fixing PVC (SWR) junction single, (Single T) equal or unequal for 110mm dia bore, complete as specified and directed.
Supply and fixing in repair 110 mm dia PVC (SWR ) floor trap/ nahani trap with grating, plain with grating including jointing with solvent cement complete all as specified and directed
Supply and fixing in repair bevelled edge mirror of superior quality glass of size as approved by Engr-in-Charge, mounted on 6-8 mm thick AC building board or commercial plywood and fixed to wooden plugs with chromium plated brass screws and cup washers including removal of old mirror, complete all as specified and directed.
Supply and fixing/hoisting in repair, rotational moulded polyethylene (HDPE) water storage tanks (cylindrical vertical with closed top), 500 litres capacity ‘triple layered’, with ISI marking embossed on it, hoisted and fixed in position including inlet, outlet and drain pipe with plug, including dismantling old water tank and removing to store, complete all as specified and directed.
Supply and fixing/hoisting in repair, rotational moulded polyethylene (HDPE) water storage tanks (cylindrical vertical with closed top), 1000 litres capacity ‘triple layered’, with ISI marking embossed on it, hoisted and fixed in position including inlet, outlet and drain pipe with plug, including dismantling old water tank and removing to store, complete all as specified and directed.
Supply and fixing in repairs 15 mm ball valves (Minimum weight 142 gms) high pressure of PTMT with epoxy coated aluminium rod & high density plastic ball screwed for iron pipe and fixed, complete all as specified and directed.
Supply and fixing Gun-metal globe or gate valves, half turn, screwed down, high pressure,heavy duty, ISI marked , with MS handle, screwed both ends for iron pipe or for unions of 15mm bore dia, including taking down old & removal, complete all as specified and directed.
Supply and fixing in repairs 20 mm ball valves (Minimum weight 210 gms) high pressure of PTMT with epoxy coated aluminium rod & high density plastic ball screwed for iron pipe and fixed, complete all as specified and directed.
Supply and fixing Gun-metal globe or gate valves, half turn, screwed down, high pressure,heavy duty, ISI marked , with MS handle, screwed both ends for iron pipe or for unions of 20 mm bore dia, including taking down old & removal, complete all as specified and directed.
Demolition of cement concrete ( unreinforced) in ground floors and pavings n. exc 15 cm thickness (below or above ground level ), complete all as specified and directed
Material and labour for 75 mm thick plain cement concrete 1:4:8 type D-2 using 40mm graded crushed stone aggregate as in sub base of floors, complete all as specified and directed.
Material and labour for 75mm thick Plain cement concrete (1:3:6), Type C-2, using 40 mm graded stone aggregate as in plinth protection, finished the surface even and fair, complete all as specified.
Supply and fixing in repairs aluminium anodised curtain rod of 20mm dia, complete all as specified and directed.
Supply and fixing in repair Aluminum anodised brackets for curtain rod of 20mm dia fixed to wall complete all as specified and directed.
Material and labour for water proofing treatment to sunken portion of WC's, bathroom etc by applying cement slurry mixed with Acrylic based polymer modified cementitious composite coimpound coating of approved make complete all as specified and as directed, comprising of following : (a) Demolition of lean concrete/red bajri/moorum up to 45 cm depth and removing (b) cleaning the surcace and applying 15mm thick plaster in cement mortar (1:4) using water proofing compound @ 3% by weight of cement on floor and sides of wall of sunken portion and finished the surface even & smooth using extra cement complete. (c) First layer of slurry of cement @ 0.488 Kg/Sqm mixed with acrylic based polymer modified cementitious composite compound @ 0.253Kg/Sqm after curing of 4 hours (d) Second layer of slurry of cement @ 0.242 Kg/Sqm mixed with acrylic based polymer modified cementitious composite compound @ 0.126Kg/Sqm after curing of 4 hours followed by curing for 48 hours.(d) After treatment of surface suken portion to be tested for water tightness, if any leakage or seepage is observed same shall be to rectified before filling the sunken portion (e) M& L for providing lean cement concrete 1:5:10 type E-2 using 40 mm graded stone aggregate in sunken filling . 200 mm long spout having dia 50mm made of GI pipe to be provided (f) M&L for providing 1:2:4 cement concrete for sub base flooring 40mm thick under tiling complete all as specified and directed
Dismantling wall and ceiling boards (fibre, pulp, insulation, etc) or insulation boards/ slabs blankets, any thickness, including cover fillets complete all as specified and directed.
Dismantling timber scantling in framed work and 40 sq. cm over in section, in any position complete all as specified and directed.
Dismantling plain or corrugated Asbestos cement (corrugated, semicorrugated, etc.) sheets in roof coverings, complete all as specified and directed.
Material and labour for Providing and fixing non-asbestos cement building tile 6 mm thick in ceiling fixed with screws, including provision of anodised aluminium snap grid frame work of size 605 mm x 605 mm and G.I. hangers 6 mm dia (upto 1200 mm length) adjusting level fixed to roof slabs by means of ceilling cleats made out of G.I. flat 40 mm x 3 mm size, 60mm long and expansion hold fasteners 12.5mm dia. 40mm long for false ceiling complete all as specified and directed.
Supply and fixing Powder coated Anodised aluminium frame for doors, windows ventilators with one or more rebates including joining cleat for fixing etc., with minimum thickness of powder coating 50 micron, complete shall as specified.
Supply and fixing Anodised Aluminium door shutter, powder coated with minimum thickness of powder coating 50 micron, aluminium section weighing 0.55 KG / RM including necessary Joining Cleats, Glazing Clips, Rubber Packing, Rubber Neoprene Packing, Screws, Anodised Aluminium Snap Beading, Anodised Aluminium Fittings in each shutter such as Handles, 200 mm Long [2 Nos], Hinges , hydraulic door closer, floor stopper , 100 mm long vertical 4 lever mortice door lock etc complete all as specified and as directed.
Supply and fixing Powder coated (thickness of powder coating not less than 50 micron) Anodised aluminium window and ventilator shutters, fixed type without sash bars, aluminium sections weighing 0.55 Kg/m, with minimum thickness of powder coating 50 micron, including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws, anodised aluminium fittings such as peg stays 150 mm long (1 No.), hinges type B-21, 100mm long (2 Nos), suitable handle (2 Nos.) complete shall as specified and directed.
Supply and fixing Mortice lock, vertical type, size 100 mm made of brass with two lever complete all as specified and directed.
Supply and fixing Door closer aluminium die cast body, hydraulically regulated, designation No. 3, universal type, suitable for door shutters of 851 to 1000 mm in width and of weight between 61 to 80 kg and fixed , complete all as specified and directed.
Supply and fixing 5.5 mm thick sheet glass ordinary quality in square or rectangular shape, in size n.exc .5 sqm each in aluminium door or window shutter including taking out old damaged glass pane complete all as specified and directed
Supply and Fixing Pre-painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick, of any colour (as approved by GE), having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws, complete all as specified and directed.
Material and labour for mild steel as in framed work of doors or gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing similar work conforming to Fe 410-W (Gde- E- 250) quality- A ,including mild steel flat iron as in hold fast including cuting holes for inserting hold fast and PCC 1:2:4 type B-1 using 20 mm graded stone aggregateas in bed block of size 150mm x230 or 115 mm x 75 mm (06 Nos in each door )complete all as specified and directed
Supply and Fixing Steel work in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I.S 1161-1979 grade St. 240 all as specified and directed.
Raking out cement/cement mortar in joints/pointing to brick work or brick tiles, laid flat, in floors, surface channels, roofs, etc., complete all as specified and directed
Material and labour for Flush pointiong to bricks laid flat or brick tiles in CM 1:3 mixed with liquid water proofing compound @ of 2% in pavings, complete all as specified and directed.
Material and labour for cutting holes in brick wall, size not exceeding 150Sqmm, including all necessary making good and match with the existing surface, complete all as specified and directed.
Material and labour for cutting chases in brick wall, size not exceeding 200Sqmm, including all necessary making good and match with the existing surface, complete all as specified and directed.
INTERNAL ELECRIFICATION WORK
Taking down carefully copper/aluminium point wiring (light, fan, socket or power) complete, including GI earth wire on batten or in PVC conduit or in MS Conduit including fixtures and fittings such as switches, ceiling roses, pendants, fan regulators, sockets etc, removing materials to store for keeping in safe custody for reuse or for credit (credit for above items shall be made as per conditions separately) and making good disturbed surface of walls, floors, etc., complete all as specified and directed.
Material and labour for point wiring with single core multi stranded copper conductor 1.5 Sqmm (nominal area) PVC insulated unsheathed FRLS colour code cable of 1100 volts grade drawn through and including non metalic rigid PVC conduit medium duty of suitable size with all standard fittings such as Tee junction, bends etc, concealed in wall/fixed on ceiling including including modular cover plate and boxes for housing switches, fan regulators etc, including 1.5 Sqmm (nominal area) multi stranded copper conductor PVC insulated unsheathed FRLS colour code cable of 1100 volts grade for earth continuity, as for one light/exhaust fan/bell point or fan point (through regulator), controlled by one switch, complete all as specified and directed. Note(s) : (i) Rate quoted shall be deemed to include cutting chases for concealing conduit and making good in cement mortar (1:4) or PCC (1:2:4) as required. (ii). Switches and fan regulator etc., shall be measured and paid separately.
All as per item No 3.02 here-in-before but for 3/5 pin socket outlet 6 Amps multipurpose on independent board.
All as per item No 3.02 here-in-before but for 2/3 pin socket outlet 6 Amps on same board with other switches.
All as per item No 3.02 above but with 2.5 sqmm cable insulated for 3 pin 15 amp multipurpose socket outlet including 2.5 sqmm PVC insulated copper wire for earth continuity on independent board.
Supply and fixing switch piano, flush type, single pole, one way, 6Amp, 230volts, complete all as specified and directed.
Supply and fixing switch piano, flush type, single pole, one way, 16Amp, 230volts, complete all as specified and directed.
Supply and fixing socket outlet, flush type, 2 in 1, multi purpose, 5 pin, 6Amps, 230volts, complete all as specified and directed.
Supply and fixing socket outlet, flush type, 2 in 1, multi purpose 6 pin, 6Amps & 16Amps, 230 volts, complete all as specified and directed.
Supply and fixing Lamp Holder, insulated body, bakelite/ PVC/Polycarbonate type with back plate suitable for batten fittings/ conduit (as required), complete all as specified and directed.
Supply and fixing LED lights fitting 1x 20W, 220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose, complete all as specified and directed.
Supply and fixing ceiling rose, surface bakelite, polycarbonate / PVC isolated body, 65mmx50mm, two to three terminals, (ISI marked), complete all as specified and directed.
Supply and fixing electronic fan regulator, step type (4/5 steps), flush type, for 1200/1400 mm sweep ceiling fans including necessary connections 240 Volt, 50Hz, 300watts, complete all as specified and directed.
Taking down old u/s exhaust fan and Supply and fixing single phase propeller type ventilating (Exhaust fan ), steel body, AC 230 volts, 450 mm sweep, Heavy duty motor, double ball bearing, complete with blades, frame and louvers, complete all specified and directed. (Old retreived exhaust fan shall be deposited in MES store yard)
Taking down old u/s exhaust fan and Supply and fixing exhaust fan made of sturdy Engineering plastic complete with louvers shutter, voltage 230V, 50 Hz, RPM 1200, Copper winding, of sweep 300mm , complete all specified and directed. (Old retreived exhaust fan shall be deposited in MES store yard)
Taking down old u/s water heater and Supply & fixing electric water heater, storage type, steel body, heating element upto 2 KW, capacity 25 litre, BEE 5 Star rated, complete with all accessories such as safety valve, thermostat, NRV, connection piece etc, complete all specified and directed. (Old retreived water heater shall be deposited to MES store yard)
Supply and fixing in replacement MCBs Distribution board sheet metal enclosures, SPN 240 Volts, 08 ways with 200 amps rated bus bar, double door for MCBs, with IP 43 protection, including blanking plate as required, including making good the disturbed surfaces to match with the existing, complete all as specified and directed
Supply and fixing MCB DP, 240 Volts, AC, B curve, 10 KA, 40 Amps,complete all as specified and as directed
Supply and fixing MCB single pole, 240 Volts, AC, B curve, 10 KA, 6 to 32 Amps complete all as specified and as directed
Material and labour for Sub Main Wiring (in replacement) with two single core 6 Sqmm (nominal area) multi stranded copper conductor FRLS PVC insulated and unsheathed colour code cables, drawn in and including non-metalic rigid PVC conduit, heavy duty of 25 mm dia, including standard fittings such as Tees, junction, bands etc., conduit concealed in wall & fixed on ceiling with suitable clamps with and including one run of continuous multi stranded copper conductor 6 Sqmm (nominal area) FRLS PVC insulated and unsheathed colour code cable for earth continuity, 1100 volts grade , complete all as specified and directed. Note(s): (i) Two runs of 6 Sqmm main cable + one run of 6 Sqmm cable for earth continuity and PVC conduit shall be measured as one unit/one Running Metre. (ii) Rate quoted shall be deemed to include cutting chases for concealing conduit and making good in cement mortar (1:4) or PCC (1:2:4) as required.
Supply and fixing LED street light fitting 35 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection, complete all as specified and as directed.
Taking down existing Celling fan 1200/1400mm sweep and depositing in MES E/M store and reflxing the same at its old position/location, including provision of requried nuts bolts, fastner, transportation etc, complete all as specified and directed.
EXTERNAL ELECRIFICATION WORK
Clean dry sand laid in trenches/ducts for bedding and cushioning to cable, 8cm in depth before laying the cable and 15 cm in depth after laying the cable including spreading, levelling and consolidation complete all as specified and directed. Note : Consolidated/punned thickness of 18 cm (overall) shall be measured for payment purpose.
Supply and laying well burnt sub class 'B' bricks for cable protection laid flat ,length wise, perpendicular to the axis of cable, complete all as specified.
Supply and laying / fixing , GI pipe light grade 40 mm dia for cable protection fixed to pole/wall or laid under floor/ road/ pavement, including MS clamp/nuts & bolts etc, including taking out old GI pipe, complete all as specified and directed.
Material and labour for vertical type sheet steel enclosure distribution boards, double door factory made 3 phase 415 volts 4 way with 200 amps rating copper bus bar of suitable size and PVC insulated copper jumpers from the MCCB to the out going circuits (one incoming MCCB and 12 outgoing MCBs circuits) comprising of 3 phase 4 wire of suitable rating including MCCB 160 amps, 25 KA, TP, 415 volts, 50 Hz = 01 No and 12 Nos MCBs 6-32 Amps, including taking out old board, complete all as specified and directed.
Supply, laying, jointing, testing and commissioning of Low Tension (LT) XLPE insulated, galvanized steel strip armoured, heavy duty, electric power cable, cross sectional area 50 Sqmm 3.5core aluminum conductor 1100 volts grade under ground cable including both side connection with cable lugs etc, laid in trenches, along poles or passing through pipes or laid under floor or through walls etc, complete all as specified and as directed. Note : Excavation and earth work, sand cushioning and precast concrete cable cover/bricks for protection of cable shall be measured and paid separately.
Supply, laying, jointing, testing and commissioning of Low Tension (LT) XLPE insulated, galvanized steel strip armoured, heavy duty, electric power cable, cross sectional area 35 Sqmm 4 core aluminum conductor 1100 volts grade under ground cable including both side connection with cable lugs etc, laid in trenches, along poles or passing through pipes or laid under floor or through walls etc, complete all as specified and as directed. Note : Excavation and earth work, sand cushioning and precast concrete cable cover/bricks for protection of cable shall be measured and paid separately.
Material and labour for earthing complete with GI earth plate electrode of size 600mm x 600mm x 6mm thick burried directly in ground vertically (depth of pit not less than 2.25 m below normal ground level), with top edge of earth plate not less than 1.5m below normal ground level, earth plate surrounded from all sides by 15cm thick packed alternate layers of charcoal dust and common salt, electrode connections using galvanized iron wire 4mm dia (upto body of equipment) by means of nuts, bolts, check nuts & GI washers, connected to main switch board or main control board or test point, protected by galvanized iron pipe light grade 40mm dia bore, and watering pipe 20mm dia bore GI medium grade with funnel & wire mesh including all necessary excavation & earth work, PCC chamber in PCC (1:2:4) type B-1 & RCC cover, all as shown in electrical plate No 3 of MES Schedule Part-I (2009), testing on completion, complete including dismantling of existing earthing all as specified and directed. Note(s) :- (i) RCC pit cover shall be pre-cast of RCC (1:2:4) type B-1, 80mm thick reinforced with XPM not less than 4Kg/Sqm. (ii) PCC chamber shall be constructed 500 mm away from the edge of earth pit. (iii) Rate shall include GI strip and protection pipe of length 7.5m, excess beyond 7.5m length required at site shall be measured and paid separately. (iv) Earth resistance should be less than 3Ohm. In case the test results are not found below 3Ohm, complete earthing will be redone without any extra cost to Govt.
Material and labour for earthing complete with GI earth plate electrode of size 600mm x 600mm x 6mm thick burried directly in ground vertically (depth of pit not less than 2.25 m below normal ground level), with top edge of earth plate not less than 1.5m below normal ground level, earth plate surrounded from all sides by 15cm thick packed alternate layers of charcoal dust and common salt, electrode connections using galvanized iron strip of size 25 mm x 4 mm thick (upto body of equipment) by means of nuts, bolts, check nuts & GI washers, connected to main switch board or main control board or test point, protected by galvanized iron pipe light grade 40mm dia bore, and watering pipe 20mm dia bore GI medium grade with funnel & wire mesh including all necessary excavation & earth work, PCC chamber in PCC (1:2:4) type B-1 & RCC cover, all as shown in electrical plate No 3 of MES Schedule Part-I (2009), testing on completion, complete including dismantling of existing earthing all as specified and directed. Note(s) :- (i) RCC pit cover shall be pre-cast of RCC (1:2:4) type B-1, 80mm thick reinforced with XPM not less than 4Kg/Sqm. (ii) PCC chamber shall be constructed 500 mm away from the edge of earth pit. (iii) Rate shall include GI strip and protection pipe of length 7.5m, excess beyond 7.5m length required at site shall be measured and paid separately. (iv) Earth resistance should be less than 3Ohm. In case the test results are not found below 3Ohm, complete earthing will be redone without any extra cost to Govt.
Taking down existing old u/s LT panel and Supply, installation, testing and commissioning factory made, tested (Including submission of CPRI type tested certificate ) LT panel board cubical outdoor type of size 0.75 x 0.75 x 0.40 mtr, plate mounted, suitable for 415 volts 3 phase, 4 wire,50 HZ AC supply system, having bus bar chamber with insulated copper bus bar of rating 400 Amp installed on poreclain/ SMC insulator. The panel shall be dust and vermin proof, IP -65 class protection and made of 3.15 mm CRCA MS sheet and 40X40X6 mm thick MS angle iron frame work, powder coated finished over one coat of red oxide on out side surface and painted in side with two coats of red oxide primer, rear opening type with apran for cable entery, closing locking arrangement, including internal wiring with PVC insulated solid copper conductor FRLS cable IS 694 marked , 1100 volts grade of appropriate size (but not less than 4.0 sqmm) and comprising of the following including necessary PCC in 1:2:4 type B1 using 20mm graded stone aggregate for platform of suitable size etc all as deirected with the following fitments:- (a) MCCB 4 pole 415 volt 250 amp rating braking capacity 36 KA incoming (Adjustable Overload 40-100%) - 01 No. (b) Bus bar: Providing suitable size of Bus bar of aluminium 400 amp rating with coloured heat shrinkable insulated sleeves 415 volts as per IS of suitable size mounted on DMC/epoxy insulator
EXTERNAL WATER SUPPLY WORK
Supply & laying GI pipes 80 mm bore, medium grade, with all standard fittings such as bends, elbows, tees etc, laid in trenches or on walls, including taking up or down existing steel water tubing and connections for re-fixing or removing from site to store for reuse or credit, including taking down standard fittings, complete all as specified and as directed.
Supply & laying GI pipes 50 mm bore, medium grade, with all standard fittings such as bends, elbows, tees etc, laid in trenches or on walls, including taking up or down existing steel water tubing and connections for re-fixing or removing from site to store for reuse or credit, including taking down standard fittings, complete all as specified and as directed.
Supply & laying GI pipes 40 mm bore, medium grade, with all standard fittings such as bends, elbows, tees etc, laid in trenches or on walls, including taking up or down existing steel water tubing and connections for re-fixing or removing from site to store for reuse or credit, including taking down standard fittings, complete all as specified and as directed.
Supply & laying GI pipes 25 mm bore, medium grade, with all standard fittings such as bends, elbows, tees etc, laid in trenches or on walls, including taking up or down existing steel water tubing and connections for re-fixing or removing from site to store for reuse or credit, including taking down standard fittings, complete all as specified and as directed.
Supply and Fixing Gun metal globe/gate valve (ISI marked), high pressure, heavy duty, with iron wheel head screwed both ends for iron pipe of 50 mm dia fixed in repair, complete all as specified and directed.
Supply and Fixing Gun metal globe/gate valve (ISI marked), high pressure, heavy duty, with iron wheel head screwed both ends for iron pipe of 40 mm dia fixed in repair, complete all as specified and directed.
Supply and Fixing Gun metal globe/gate valve (ISI marked), high pressure, heavy duty, with iron wheel head screwed both ends for iron pipe of 25 mm dia fixed in repair, complete all as specified and directed.
COMMON ITEMS FOR EXTERNAL ELECRIFICATION AND EXTERNAL WATER SUPPLY WORK
Excavation in trenches in soft/loose soil not exceeding 1.5 meter wide and not exceeding 1.5 meter deep for laying of cables, pipes and foundation of poles etc. and getting out complete all as spceified and directed.
Returning, filling in trenches (soil) including spreading leveling and well ramming in layers not exc 25 cm thick complete all as specified and directed.
Removal of surplus excavated soil to a distance not exc 50 mtr and depositing where directed at a level not exc 1.5 mtr above the starting point, complete all as specified and directed.
Note: The Total amount shall subject to adjustment of credit of Rs. 95,549.50 for old Materials as per Schedule of Credit.
M/s AKG Engineers & Contractors
kapoor and co
VISHWAMITRA CONSTRUCTIONS
M/S BALWINDER SINGH
B.J.CONSTRUCTION CO
GEE EMM ASSOCIATES
AAR KAY BEE ENTERPRISES
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .