SITC of 08 Passenger Lift for Lab-Cum-Lecture Block under Upgradation of Existing Infrastructure Residential Quarters / Labs / Classrooms (CAPEX) at FoFy Rangil, SKUAST-K.
2026_SKUST_325659_1
E-NIT-58 of 2026-27
Open Tender
Miscellaneous Works
Percentage
90 days
FoFy Rangil, SKUAST-K
Please refer Tender documents.
6 documents required · 6 mandatory
₹2,000
Assistant comptroller
₹71,100
22 Sept 2026
22 Sept 2026
6 Oct 2026
22 Sept 2026
5 Oct 2026
25 Sept 2026
This is a percentage-rate BOQ. The schedule below shows estimated quantities and rates. Bidders quote a single percentage above or below the total estimated cost.
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Passenger Lift with the following Specifications as per IS:-14665 (2000) along with AMC of 3 years.
capacity passenger ,Machine room less (MRL) General Specification for Electrical Works (Part-III Lift & Escalator) 2003, BIS Codes, NBC 2016 as amended upto date having provision for barrier free access as per Harmonised Guidelines & Standards for Universal Accessibility in India - 2021 of MoHUA, serving different floors in the lift shaft as per detailed specifications enclosed and as under including all other equipment and accessories complete as required :- | 1 | No. | 22,30,000 | ₹22,30,000 |
| 1.01 | Supply, Installation, Testing & Commissioning of 8 Passenger (G+3). The lift shall be suitable for 8 passengers of standard design having speed of 1.0 m/s serving from ground to 3rd floor i.e. 04 stops and 04 landings. The elevator shall be of state of art technology, energy efficient drive and all its components/ accessories shall conform to relevant IS standards.
• (The Defect Liability Period (DLP) of the equipment shall be 01 years with 3 years of CMC post DLP)
• Machine – Gearless machine located in the shaft on the top of guiderails
• Power Supply – 400/415 V (3 Phase AC)
• Control – Simple Collective Selective Control (VF regenerative drive)
• Available Hoist way dimensions -
1) 1550mm (W) x2000mm (D) • Car travel - 12 m. • Overhead - 4000mm • Pit depth - 1350mm. • Landing door – 2 panel automatic centre
Door opening :One side only
• Car design - Stainless steel in SS hairline finish. • Car floor - Granite
• Handrail - round handrail in stainless steel finish provided on rear wall of car.
• Alarm button in car operating panel with battery back-up.
• Automatic operation for car fan. • Anti-nuisance (empty car) | - | - | - | - |
| 1.02 | • Anti-nuisance (car call cancellation at direction reversal)
• Blower fan in car for ventilation • Braille on push buttons
• Door open and door close buttons in car operating panel. • Door closing retries
• Door nudging • Emergency light • Full load by-pass • Infra–red screen for car door
• Intercom Provision With Instrument • Motor overheat protection.
• Overload function with audio-visuals indication in car operating panel. • Phase failure and phase reversal protection.
• Automatic rescue device in case of power failure. • Attendant control.Car arrival chime on car top/voice synthesizer.
• LCD dot matrix scrolling display in car operating panel. • LCD matrix scrolling display in landing operating panel on all floors.• Fireman control. •
Fireman emergency return | - | - | - | - |
| 1.03 | STOPS: 4 Stops With (all opening on the same side)
Drive :Microprocessor Based V3F Drive.
Machine : P M Gearless (Located in shaft on top of guide rails)
Car Finish :
Rear Mid Panel = SS Honey Comb Rear Corner Panels = SS Honey Comb Side Mid Panels = SS Honey Comb Side Corner Panels = SS Honey Comb Front Panels = SS Honey Comb ,opening door in stainless steel SS hairline finish.
False Ceiling Finish: SS Mirror FinishHand Rail :Stainless Steel Hair Line Finish Handrails on rear car panel.
Ventilation:Cross flow fan.
Flooring:Granite Flooring /anti skid /equivalent.
Door Operator: DC Door Operator / Telescopic . | - | - | - | - |
| 1.04 | Standard Features :
(i) Speed-1.0- 1.5 MPS (ii)Floors-5(G+4) (iii) Travel-17 metres(approx) (iv) Stops & opening : 4 stops and 4 openings (v) Controller: A.C. variable voltage & variable frequency (vi) Automatic rescue device (ARD) complete with dry maintenance free batteries as required. (vii) Operation: Microprocessor based single automatic push button/simplex selective collective/ duplex collective selective with/without attendant (viii) Power-415 Volts+10%, 3 phase, 50 Hz, 4 wires system (ix) Car Enclosure: Stainless steel scratch proof (Moon Rock/Honeycomb/ Hairline Finish) on all sides and stainless steel decorative ceiling with fans (indirect throw) and LED fitting. (x) The car flooring should be smooth and antiskid as approved by engineer-in-charge. (xi) Type of doors:- (a) Car: Power operated, centre opening horizontal sliding stainless steel scratch proof (Moon Rock/Honeycomb/ Hairline Finish). (b) Landing doors: stainless steel scratch proof . (xii) A hand rail not less that 600mm long at 900mm above floor level to be fixed adjacent to control panel in the lift car. (xiii) Voice announcement system in the car to announce the position of the elevator in the hoist way as the car passes or stops at floor served by the elevator. | - | - | - | - |
| 1.05 | (xiv) Closed loop Control System, protection against power fluctuation, self diagnostic control, Landing 112 DELHI SCHEDULE OF RATES (E&M)-2025 doors 2 hours Fire rated, Overload detection and protection, Overs peed Governer, Dot Matrix LED D & P Indicators In Car &Landings, BMS Compatibility, tamper proof infrared curtain covering almost the entire height of the lift car door, Alarm horn, Anti Nuisance Operation, CCTV camera system with 4 MP IP camera, suitable NVR and HDD for 30 days storage backup , Firemen switch, 2/3 way intercom, Emergency Stop Switch with battery backup for fan and light fitting for 1 hour, pit ladder. (xv) The lift doors shall have a vision panel to enable persons with hearing impairment to signal for help or assistance in the event of an emergency. (xvi)An appropriate technological support be provided (Through emergency messaging |services or alarms etc.) to respond to the emergency requirements of person with hearing impairment or deafness. (xvii) In case of failure of ARD or other electronic devices, a provision of manual rescue be provided. | - | - | - | - |
| 1.06 | Anti-nuisance Car Call Protection
Control System :- Simplex automatic operation Overload Device Nudging
Floor Annoucement Syatem with Music Emergency Firemen’s Service Emergency Car Light Unit
Infrared Curtain Door Protection
Full Car Operating Panel 8 Press & Speak Phone Door Time Protection
Emergency Alarm Button
Extra Door Time of Lobby & Parking Door Open/Close Button
Automatic Rescue Device with Dry Maintenance Free Batteries Auto Fan Cut Off
Provision of CCTV Camera
Fire Rating of Landing Doors for 2 Hours Floor Annuciator with Music
Provision of 3 way intercom with instrument. Indicators in Car and Landings | - | - | - | - |
| 2 | Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm) | 12 | Rmt | 160 | ₹1,920 |
| 3 | Providing and fixing 25 mm X 5 mm G.I. strip in 40 mm dia G.I. pipe from earth electrode including connection with G.I. nut,
bolt, spring, washer excavation and re-filling etc. as required. | 50 | Rmt | 755 | ₹37,750 |
| 4 | S/L of 4 X 16 sq. mm + 2 X 6 sq. mm earth wire and termination works etc in PVC conduit | 50 | Rmt | 1,454 | ₹72,700 |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.49 MB
BOQ_1100920.xls
BOQ • 0.34 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .