Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹37.8 LAccepted-Finance | ₹37.8 L | L1 | Accepted-Finance Lowest quoted |
| 2 | L2₹39.1 LRejected-Finance | ₹39.1 L | L2 | Rejected-Finance Highest quoted |
| Sl No | Description | Qty | Unit | Shiva Engineering Work L1 | VS CONSTRUCTION L2 |
|---|---|---|---|---|---|
| 1.00ATTENDING MAJOR LEAK AND BURST IN AC PIPELINES | |||||
| 1.10Attending Leaks and bursts in the AC pipelines using MS Barrel, as per the standard procedure including earthwork excavation, dewatering, removing, relaying, jointing, civil works, cost of materials and all other incidental charges, etc complete | |||||
| 1.20 | 300mm AC CL15 pipes | 10 | Nos | 63,026 ₹6.3 L | 64,500 ₹6.5 L |
| 1.30SUPPLY, DELIVERY AND LAYING OF 300MM AND 250MM DI PIPELINES | |||||
| 1.40Supply and delivery of centrifugaly cast (spun) Ductile Iron pipes to the site of work confirming to IS 8329/2000 with inside lining with cement mortor of standard thickness and specifications and outside coating of Metalic Zinc as per IS specifications. The cost of pipes should include loading, freight, transit insurance, incidental charges, packing, taxes and transportation charges to stack yard in good condition etc., complete (the cost excluding unloading from lorries at stack yard and stacking which will be paid seperately) as directed by Departmental officers | |||||
| 1.50 | 300 mm K9 Class S/S Pipes | 245 | M | 5,100 ₹12.5 L | 5,250 ₹12.9 L |
| 1.60 | 250 mm K9 Class S/S Pipes | 50 | M | 4,019 ₹2.0 L | 4,125 ₹2.1 L |
| 1.70Supply and delivery of centrifugaly cast (spun) Ductile Iron pipes Flanged pipes PN 10 to the site of work confirming to IS 8329/2000 with inside lining with cement mortor of standard thickness and specifications and outside coating of Metalic Zinc as per IS specifications. The cost of pipes should include loading, freight, transit insurance, incidental charges, packing, taxes and transportation charges to stack yard in good condition etc., complete (the cost excluding unloading from lorries at stack yard and stacking which will be paid seperately) as directed by Departmental officers | |||||
| 1.80 | 250 mm DI class PN10 D/F pipes - 1 m | 5 | Nos | 9,555 ₹47,775 | 10,150 ₹50,750 |
| 1.90Supply and delivery of the following GI Pipes and Specials etc complete as directed by Departmental officers | |||||
Tender Value
₹45 L
EMD Value
₹45,000
Closing Date
26 Mar 2025, 3:00 pmClosed
THE COMMISSIONER
Salem City Municipal Corporation, Fort Main Road, Salem.
Improvement of Water Supply Distribution Network in Division No 51,52 ,Zone- IV, Salem City Municipal Corporation
2025_MAWS_533736_1
E2-Est No 634-WS-2024-2025
Open Tender
Civil Works
15 days
Salem city Municipal Corporation
Please refer Tender documents.
1 document required · 1 mandatory
₹0
₹45,000
15 Dec 2025
19 Mar 2025
26 Mar 2025
19 Mar 2025
26 Mar 2025
19 Mar 2025
Amount
ATTENDING MAJOR LEAK AND BURST IN AC PIPELINES
Attending Leaks and bursts in the AC pipelines using MS Barrel, as per the standard procedure including earthwork excavation, dewatering, removing, relaying, jointing, civil works, cost of materials and all other incidental charges, etc complete
300mm AC CL15 pipes
SUPPLY, DELIVERY AND LAYING OF 300MM AND 250MM DI PIPELINES
Supply and delivery of centrifugaly cast (spun) Ductile Iron pipes to the site of work confirming to IS 8329/2000 with inside lining with cement mortor of standard thickness and specifications and outside coating of Metalic Zinc as per IS specifications. The cost of pipes should include loading, freight, transit insurance, incidental charges, packing, taxes and transportation charges to stack yard in good condition etc., complete (the cost excluding unloading from lorries at stack yard and stacking which will be paid seperately) as directed by Departmental officers
300 mm K9 Class S/S Pipes
250 mm K9 Class S/S Pipes
Supply and delivery of centrifugaly cast (spun) Ductile Iron pipes Flanged pipes PN 10 to the site of work confirming to IS 8329/2000 with inside lining with cement mortor of standard thickness and specifications and outside coating of Metalic Zinc as per IS specifications. The cost of pipes should include loading, freight, transit insurance, incidental charges, packing, taxes and transportation charges to stack yard in good condition etc., complete (the cost excluding unloading from lorries at stack yard and stacking which will be paid seperately) as directed by Departmental officers
250 mm DI class PN10 D/F pipes - 1 m
Supply and delivery of the following GI Pipes and Specials etc complete as directed by Departmental officers
100mm GI pipe
100 mm GI Flange set
100mm GI Elbow
150mm GI pipe
150mm GI Elbow
150mm GI Tee
150mm GI Bend
150 mm GI Flange set
Supply and delivery of DI specials confirming to the relevant IS specification supplied at the site of work including loading, freight, unloading, stacking at site, transit insurance charges etc. complete. - For Pumpin mains and Valves
S/S Specials in Kg - 250 mm - 300 mm
Supply and delivery ofCI sluice valves non raising spindle types to pressure rating of 1.6 PN to be used in pump houses (long body/ long face to face) conforming to is and with 5 years warranty
250mm CI Sluice valve
Supply and Delivery of DI D/F Gate valves (Soft Seated) resilient seated soft sealing gate valves with body bonnet of ductile cast iron of grade GGG40 or equivalent grade, wedge fully rubber lined with EPDM, replaceable spindle nut, without gland packing and with 3 O-Ring protection on the shaft and seals of NBR and the valves should be of vaccum tight and 100% leak proof with face to face dimentions as EPR BS 5163-89/ ISI 14846-2000/ DIN 3202 F 4. All the valves should be with electrostatic powder coating both inside and outside with pocket less straight thro' body passage. All the valves are to be compatible for burried application with pressure rating PN 10/16, etc. complete..
250mm DI Sluice valve
Earth work excavation and depositing on bank with initial lead of 10 m and lift of 2 M in narrow trenches having bed width 1.25m & below for laying of pipes for water supply and sewerage works in the following type of soils as directed by Departmental officers
For 300mm DI Pipe
Medium rock and dence medium rock requiring blasting
Hard rock measured in solid including blasting and stacking
For 250mm DI Pipe
Medium rock and dence medium rock not requiring blasting
Cutting of road surface for pipeline trenches and disposing of the excavated materials as directed by the Engineer including barricading, Danger ligthing etc. as directed by Departmental officers
Cutting of B.T. Roads (or) Maccadam road for laying of following dia pipes
300 mm DI Pipes
Lowering GI / DI pipes and specials in the trenches and laying to proper grade and alignment as per standard specifications as directed by Departmental officers
300 mm DI Pipes
250mm DI Pipes
150mm GI Pipes
Barricading work (Where the lines are in narrow width of municipality area, busy streets like Market, Busstand and in the Highways etc.) for laying of pipe line using casurina poles at 1.50m center to center (8cm to 10cm dia. and 1.80m height) vertical with horizontal poles in two rows, painting the vertical poles in the road facing sides with ready mix paint, tying the vertical and horizontal poles with coir rope including supplying, delivery and fixing of GI sheet (0.90m x 0.8mm thick) in the horizontal poles and fixing 75mm dia. reflectors including earth work excavation for fixing vertical posts and finally removing and stacking the materials safely for further use etc., complete as directed by Departmental officers
Refilling with excavated earth (other than sand) in respect of following sizes of pipes watered well rammed and consolidated etc. complete complying with standard specification for filling the trenches after the pipes and specials are laid, jointed and tested .
300 mm DI Pipes
250 mm DI Pipes
Testing of MS/P.V.C/ HDPE/ D.I Pipes with hydraulic testing equipment by filling with water (Including cost of water @ Rs.60/KL) and testing to recommended pressure inconvenient stetches and attending the bursts if any occurred during the test, excluding the cost of pipes,including other incidential and operational charges etc., complete for the following diameter of pipes as per standard specifications as directed by Departmental officers
300 mm K9 Class S/S Pipes
250 mm K9 Class S/S Pipes
Convenyance of pipe of various type/sizes of the following pipes including, unloading from lorries at Stackyard and stacking properly and Loading in to Lorries at Stackyard, transportation charges up to 8km from stockyard and unloading from lorries at site/ along the alignment carefully as directed by Departmental officers
I. C.I / D.I /G.I Pipes
Over 200 mm up to 350 mm
Jointing the DI S/S Pipes and specials with Rubber Gasket (Tyton joints) including cost of lubricants etc., complete as per standard specifications.. (including cost of jointing materials) as directed by Departmental officers
300mm DI S/S Pipes and specials
250mm DI S/S Pipes and specials
Jointing the C.I/ D.I Double flanged pipes SS 97, 98 and specials with rubber insertion to the required specifications with M.S. bolts and nuts, complete.and as directed by the TWAD Board officers (including cost of jointing materials) as directed by Departmental officers
For depth up to 2m (for works above water level)
250 mm C.I/D.I D/F Pipes and specials
Jointing the C.I/D.I S/S Pipes SS 97, 98 and specials with neat cement or cement morter and spun yarn including caulking the joints curing as per standard specifications. (including cost of jointing materials) as directed by Departmental officers
For depth up to 2m
250mm dia C.I/D.I Pipes and specials
Construction of masonry pit as per TWAD Type design for Valve pit including lowering and fixing the valves including earth work excavation for foundation, P.C.C. 1:4:8 using 40mm HBG metal for levelling course, brick work in CM 1:5 for side wall, plastering with CM 1:3, 12mm thick, RCC 1:1½:3 using 20mm HBG stone jelly for cover slab, providing cut stone in CM 1:3 including supply, fabricating and placing of RTS grills for the following valves including charges for precasting and fixing surface box, valves and laying pipes and specials specials in position, refilling the sides of the pit etc., complete as directed by Departmental officers
250 mm Sluice valve
Providing Thrust Blocks for the following sizes (vide separate estimate)
200 mm - 90 deg bend
SUPPLY, DELIVERY AND ERECTION OF OWS PUMPSETS
Supply and delivery of wet type Open well Submersible pumpsets capable of discharging the following pumpage in lpm against noted head in m suitable for erection into the Infiltratin well / Open well of 4.5m/3.5m/any dia with stainless steel shaft, bronze impeller and stainer with brass screws, water lubricated bearings with sand guard. The non-return valve located at the top of the pump in the discharge outlet connection is to be designed with minimum frictin. The pump should be directly coupled to 2880 rpm, 3phase, 50 Hz, 415V+6% & 415V-15% squirrel cage induction motor suitable for DOL starting and for continuous operation. The pumpset should be provided with 3 m length of suitable size PVC insulated copper flat cable for connecting the pumpset, starter & isolator. The pumpset should conform to IS 14220 and as amended thereafter and bear ISI marking as directed by Departmental officers
20 HP - 1000 Lpm x 40 m Head
150mm dia Pressure Gauge and Vaccum guage including all accessories as per specification (For Delivery to be mounted on wall on Teak Wood Board)
1) Pressure gauge should have twice working pressure of pump and with red marking at duty point.
2) The maximum range should be above the shut-off head.
Supply and delivery of Fully automatic Air break auto Transformer Starter with single phasing preventor with ammeter con firming to IS 8544 Part IV with auto resatart facility etc complete as directed by Departmental officers
For 20 HP OWS Pumpset
Power capacitor for power factor improvement with oil filled with discharge resistance 3 phase 415 / 440V 50 HZ conforming to ISS with ISI marking as directed by Departmental officers
For 20 HP OWS Pumpset
Supply & delivery of floor mounting type weather, vermin and dust proof powder coated L.T. cubical panel board made of 20 SWG MS sheet & MS angle iron frame work with enclosed 4 Nos of Aluminium busbars of Electrolyte grade E.91,PVC sleeved of suitable size for phase and neutral with hinged front door and railway lock and key arrangements. The bus bars shall be of ample current carrying capacity with all internal wiring as per I.E.rules and as per IS 8633 and as per safety requirement of CEIG. The design of panel board should facilitate for quick operation of all switches from front side. The panel board should be completed with all internal iring including necessary earthing arrangements and consists of the components for controlling incoming and outgoing supply. as follows
100 Amps 3 Pole MCCB for outgoing with interlocking arrangements, etc., complete (Rs.6536 x 1.35 x 2 No = Rs.17647.20) - Capacitors
100 Amps MCB TRIPLE Pole for lighting (Rs.7298 x 1.35 no = Rs.9852.30)
Digital Voltmeter- Three Phase
Digital Ammeter- Three Phase
NOTE : System power factor should be maintained by 0.9 lag and as per latest I.E. rules.
I) The Busbar should be well supported and necessary allowances should be made for busbar expansion.
ii) The Busbar supports should be moulded from thermossetting fibre glass reinforced polyester materials.
Supply and delivery of 1.1 KV grade, 3.0 core 4 sq.mm PVC insulated & sheathed flat type copper cable conformig to IS:694 / 1990 to lay in between Starter and OWS Motors as directed by Departmental officers
Laying the above cable as per IE rules in between Starter and OWS Motors as directed by Departmental officers
End jointing of cable including jointing cost and jointing Materials like cable glands etc complete as directed by Departmental officers
Supply and delivery of 200 Amps Porcelain Fuse Unit (500V)
Labour charges for the erection of submersible pumpset in borewell/openwell including fixing and jointing submersible cable with proper clamps upto the starter to required depth and also fixing of riser pipes to the required depth valves erection clamps, pressure gauges upto the exterior wall of pump room and erection of panel board consisting of TPICN switches starter, Voltmeter, Ammeter, three pilot (indicating) lamps capacitor single phasing preventor, water level guard and laying and jointing the cables and twin earthing as per IE rules etc., complete and testing the pumpset and trail run for 10 days. as directed by Departmental officers
Above 10 HP to 20 HP
Supply and delivery of GI pipes and specials for pipe connection as per relevant IS (vide Seperate Estimate )
100 mm GI Pipe connection
VS CONSTRUCTION (BID ID -1278198)
stage.html
html • 0.03 MB
tech_eval.pdf
fin_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid