Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Tender Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹21.8 LAccepted-AOC | L1 | Accepted-AOC L1 | |
| 2 | L2₹24.9 L+₹2.3 L (10.3%)Rejected-AOC NO 7 3RD MAIN ROAD MUNI REDDY LAYOUT HORAMAVU MAIN ROAD BANASAWADI BANGALORE 560043 | BENGALURU URBAN | KARNATAKA | 560043 | L2 | Rejected-AOC L2 | |
| 3 | L3₹25.6 L+₹3.0 L (13.5%)Rejected-AOC M S RRK PROJECTS D 306 ADG P CHENNAI 11 3RD CROSS SIR MV LAYOUT VIDHYARANYAPURA POST BANGALORE 560097 | BENGALURU URBAN | KARNATAKA | 560097 | L3 | Rejected-AOC L3 | |
| 4 | L4₹26.8 L+₹4.2 L (18.4%)Rejected-AOC | L4 | Rejected-AOC L4 |
Tender Value
₹26 L
EMD Value
₹52,000
Closing Date
22 Jul 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (AF) Yelahanka
GE (AF) Yelahank Bangalore-63
REPAIR/REPLACEMENT OF VARIOUS HANGAR LIGHT FITTINGS AT AF STN YELAHANKA AND REPAIR/MAINTENANCE OF GEYSERS, FANS AND ENERGY METERS AT AF STN YELAHANKA
2023_MES_604331_1
8172/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
AF Stataion Yelahanka
AS PER NIT
9 documents required · 9 mandatory
₹500
₹52,000
Yes
10 Aug 2023
19 Jun 2023
24 Jul 2023
19 Jun 2023
22 Jul 2023
3 Jul 2023
Amount
M&L for sub-main wiring with two runs of 1.5 sqmm unsheathed PVC insulated, single core heavy duty ISI Marked FRLS cable 1100 volts grade with multistranded copper conductor drawn through and including not less than 20mm dia non metallic rigid PVC white conduit/casing caping and conduit accesories concealed/fixed to wall/roof/floor and including suitable PVC conduit with 1.5 sqmm copper earth wire after taking out the existing sub-main wiring, making good to the distrubed surfaces also matching the existing surfaces all as specified and directed. Note: 2 runs of cable and one run earth wire and conduit will be measured as one length. Three run of 2.5 Sq mm and PVC conduct is measured as one Run or one Meter.
All same as per item No 1 here-in-before but size 2.5 Sqmm.
Supply and fix in repair LED flood light 150 Watts, 230 V AC outdoor type with thermal management in multiple optics, powder coated pressure die cast aluminium body with toughened glass visor, and equipped with IP66 protection, with impact and corrosion resistant complete with driver and lamp,CCT 5700K, lumen efficacy not less than 110 lumen/watts including testing commissioning and fixing upto 20 Mtr hight of hanger including necessary fixing arrangement of clamps nut bolts etc complete all as directed by Eng-in-Charge.
Supply and fix in repair LED flood light 200 Watts, 230 V AC outdoor type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant complete with driver and lampCCT 5700K, lumen efficacy not less than 110 lumen/watts including testing commissioning and fixing upto 20 Mtr hight of hanger including necessary fixing arrangement of clamps nut bolts, chain locking etc complete all as directed by Eng-in-Charge.
All same as per item No 4 here-in-before but 250 Watts.
Supply and fixing industrial LED High Bay light fitting power range of 200 Watts, powder coated PDC aluminium body & PC optical lenses, Lumen efficiency of >110lm/W, 5700K CCT, Alluminum Die cast housing, IP66 with life of 50,000hrs with Eye bolt provided for mounting purpose for fixing on wall/ceiling mount available as accessory, flexible options to meet industrial lighting needs i.e. suspended/fixed to Hanger Ceiling, cool white light colour, material made out of die cast aluminum & extruded aluminum heat sink and finish powder coated complete connecting electrically including testing commissioning and fixing upto 20 Mtr hight of hanger including necessary fixing arrangement of clamps nut bolts, chain locking etc complete all as directed by Engineer-in-charge.
Supply and fix in repair LED lights fitting 20 Watt, 220V, 4 feet long, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and directed by Engr-in-Charge.
Supply and fix in repair LED lights fitting 10 Watt, 220V, 2 feet long, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and directed by Engr-in-Charge.
Supply and fix driver suitable for 120/150 Watt LED flood light fittings and testing complete including taking down the Same all as specified and directed.
Supply and fix driver suitable for 200/250 Watt LED lood light fittings and testing complete including taking down the Same all as specified and directed.
Supply and fix LED Aviation light luminaries Integral LED aviation light comprising of aluminium housing with polycarbonate enclosure complerte all as specified and as directed. Make - Bajaj Cat Part No. 110731 BGAV 302 LED or its techno equivalent.
Supply and fixing LED luminaire 600 mm x 600 mm, 36 watt, 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete all as specified and directed by Eng-in-Charge.
Supply and fix in repair round/Square shape 18 watt 220 volts AC recessed/surface type with high efficiency PMMA diffuser soft glare free light complete with drivers, holders, LED lamp suitable for roof ceiling including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed by Engr-in-Charge.
Supply and fix in repair building security light LED street light fitting 72 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP-66 protection complete all as specified and directed by Engr-in-Charge.
Supply and fix in repair 415V 10KA 'B' curve miniature circuit breaker (MCB) of 40 to 100 Amps rating triple pole and neutral in the DB complete with connection testing and commissioning all as specified and directed by Engr-in-charge.
Supply and fixing in repair 230V 10KA 'B' curve miniature circuit breaker (MCB) of 32 Amps rating single pole and neutral in the DB complete with connection testing and commissioning all as specified and directed by Engr-in-charge.
Supply and fixing in repair 230V 10KA 'B' curve miniature circuit breaker (MCB) of 6 to 32 Amps rating single pole in the DB complete with connection testing and commissioning all as specified and directed by Engr-in-charge.
Note 1 to 17:- (a) Highbay light/ Flood light/ Street light/ recessed, surface mounted light and submain wiring to be repaired/ replaced upto 20 Mtr Height. (b) The expenditure on Ladder/ Crane will be borne by the contractor and all rates deemed to be inluded the same. (c) Hangar lights must be fixed properly to avoid harm/ damages to Aircrafts/ Helicopers/ persons.
M&L for painting of ceiling/exhaust fans complete, in situ with synthetic enamel paint by spraying including filling cavities with filler, one coat after cleaning all dust etc. complete all as specified and as directed by the Engr-in-Charge. Note : White paint to be used for ceiling fans and gray/sky blue paint to be used for exhaust fans.
Disconnecting and taking down the ceiling fan 1200/1400mm sweep carefully dismantling blades and removing fan complete, servicing by cleaning and greasing the bearing/bush and replacement of split pin, replacing unserviceable items like bearing, bushes, rubber real, condenser, flexible cable, canopy, etc., assembling, refixing after complete servicing in the original place connection and testing complete all as specified and as directed by the Engr-in-Charge. Note;- Replacement of unserviceable items will be measured and paid under relevant items.
All same as per item No 20 here-in-before but exhaust fan 280/300/450 mm sweep
All same as per item No 20 here-in-before but wall mounted fan 300/400/630 mm sweep
Supply and fix ball bearing for 1200/1400mm sweep Make :- TATA/ SKF/NBC
Supply and fix ball bearing for Exhaust fan 280/300 /450 mm sweep Make:- TATA / SKF/NBC
Supply and fix ball bearing of suitable size for wall mounted fan of 300/400/630 mm sweep Make:-SKF/TATA
Supply only gun metal bushes for 1200/1400mm sweep ceiling fan
Supply only condenser 2.5/3.5 Mfd for ceiling fan
Supply only of canopy for 1200/1400 mm Sweep ceiling fan
Supply only blades suitable for 1200/1400/1500mm sweep ceiling fan set of 3 blades.
Supply only blades suitable for Exhaust Fan of size 280/300/450 mm sweep
Supply only blades suitable for Wall mounted fan of size 300/400/630 mm sweep
Supply and replacement down rod for ceiling fan with 15mm dia GI pipe medium grade ,screwed and drilled with clamps rubber real ,nuts,bolts, and safety pin,etc including painting ,up to 3 mtrs height.
Collecting the burnt ceiling fans of 1200 mm Sweep including blades of any make from AGE E/M store yard/ site, bring to reputed work shop/in-situ, dismantling removing the burnt winding, rewinding of ceiling fan with super enameled copper conduct winding wire of same gauge, insulating, varnishing, baking, including replacing of wornout bearing/ bush greasing assembling and transporting the same and fixing and testing at site all as specified and as directed by Engr-in-charge,
Collecting the burnt ceiling fans of 1400/1500 mm Sweep including blades of any make from AGE E/M store yard/ site, bring to reputed work shop/in-situ, dismantling removing the burnt winding, rewinding of ceiling fan with super enameled copper conduct winding wire of same gauge, insulating, varnishing, baking, including replacing of wornout bearing/ bush greasing assembling and transporting the same and fixing and testing at site all as specified and as directed by Engr-in-charge,
All same as per item No 34 here-in-before but Wall mounted fan 300/ 400mm sweep
All same as per item No 34 here-in-beforeb but Exhaust Fan of size 280/300 mm sweep
All same as per item No 34 here-in-before but Exhaust Fan of size 450mm sweep
Taking down opening and inspection of storage type water heater of size 25/ 50ltrs capacity and discaling with dilute hydrochloric acid, checking for water tightness of the inner tank, cable continuity, thermostat most of setting at 70 degree C checking fusible plug, stop cock including replacement of indicator lamp, rubber PVC gasket washers reassembling and refixing at old place and replacing unserviceable bolts and nuts, cementing work including hydraulic pressure testing with hard operated hydraulic pump complete after repair including spray painting of one coat with DUCO paint of approved in after preparation of surface Note:- (a) Replacement of unserviceable items like heating element, Indicator lamps, thermostat, stop cock, 3 core copper cable will be measured & paid separately. (b) Repalcement of Glass wool is included in the unit rate. (c) Replacement of Hot cold pipe is included in the unit rate.
Supply only heating element including rubber/PVC gasket of the following all as directed including rubber washer 1.5KW / 2 KW any type
Opening, removal, testing and repalcement and calibration of thermostat of the geyser including rubber gasket and setting temperature between 70 degree C to 80 degree C for capacity of 25/50 Ltrs.
Checking thermostat calibration only of the geyser 25/50 ltrs capacity and setting temperature between 60 degree to 70 degree complete all as directed.
Material and Labour for disconnecting from Electric and water mains and dismantling the unserviceable gyeser base assembly and replacing the new base assembly with rubber gasket for 25 Ltrs capacity of any make and refixing in original place including recoonecting of electric and water supply mains including testing complete all as speicifed and directed by Engr-in-charge.
All same as per item No 42 here-in-before but 50 Ltrs capacity
Material and Labour for Brazing of Storage Type water heater (Geyser) to stop leakage and testing of any capacity and make after completion upto the satisfaction of concerned JE/ Engr-in-Charge. Note :- Disconnecting and reconnecting of geyser (water and elctric ) is included in unit rate.
Supply only Non Return Valve for 25/50 Ltrs capacity of existing type and make complete all as specified and directed by Engr-in-charge.
Supply only copper tank for 25 Ltrs capacity of existing type complete all as specified and directed by Engr-in-charge.
All same as per item No 46 here-in-before but capacity 50 Ltrs
Supply only PVC connections 15 mm size with PTMT nuts of length 450 mm length (for hot and cold water inlet and outlet) complete all as specified and directed by Engr-In-charge.
All same as per item No 48 here-in-before but 0.9/1m length.
Supply and fix in repair electronic meters temper proof, LCD display with polycarbonate cover single phase, 230 V, 10-60Amp, accuracy class-I 50Hz, conforming to IS 13779, IP-54, with parameters to show data, time, current reading, load, PF, voltage and KWH. NOTE:- old/unservicable energy meters will be deposited to E/M store.
All same as per item No 50 here-in-before but 3 Phase, 415 volt
M & L for glass wool packing required quantity for covering the 25 ltrs copper shell to avoid the heat conduction .
M & L for glass wool packing required quantity for covering the 50 ltrs copper shell to avoid the heat conduction .
Supply and fix metal louvers of suitable size for exhaust fan of the following sweep
(a) 450 mm sweep
(b) 300 mm sweep
(c) 230 mm sweep
Supply and fix in repair stepped type electronic fan regulator flush type as per site requirement (Switch/Socket type) on the existing phenolic laminated sheet etc. as reqd including disconnecting, taking down old/unserviceable fan regulatorcomplete all as specified and as directed by Engr-in-Charge.
Supply and fix in repair modular step type fan regulator, 120 Watt, 2 module including disconnecting, taking down old/unserviceable fan regulatorcomplete all as specified and as directed by Engr-in-Charge.
M&L for sub-main wiring with two runs of 4.0 sqmm unsheathed PVC insulated, single core heavy duty ISI Marked FRLS cable 1100 volts grade with multistranded copper conductor drawn through and including PVC casing caping fixed to wall/roof/floor and including suitable PVC conduit with 1.5 sqmm copper earth wire after taking out the existing sub-main wiring, making good to the distrubed surfaces also matching the existing surfaces all as specified and directed. Note:- 2 runs of cable and one run earth wire and PVC casing caping will be measured as one length. Three run of 4.0 Sq mm and PVC casing caping is measured as one Run or one Meter.
Supply and fix in repair exhaust fan 300mm sweep, made of sturdy Engineering plastic complete with louvers shutter, voltage 230V, 50 Hz, RPM 1200, Copper winding complete all as specified and directed by Engr-in-Charge.
Supply and fix in repair exhaust fan 250mm sweep made, of sturdy Engineering plastic complete with louvers shutter, voltage 230V, 50 Hz, RPM 1200, Copper winding complete all as specified and directed by Engr-in-Charge.
ARUNOTHAYA TRADERS
RRK PROJECTS
Gee Kay Projects
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .