EXECUTIVE ENGINEER (E)
ELECTRICAL DIVISION-3 SIRI FORT, BEHIND GARGI COLLEGE NEW DELHI-110049
Comprehensive and Running Maintenance of CCTV Camera (Surveillance), PA and Data Networking System with Accessories at PVSC, VKSC and BGNSC.
2026_DDA_914233_1
11/EE/ELD-3/DDA/2026-27
Open Tender
Electrical Works
Percentage
365 days
As per tender document
Please refer Tender documents.
16 documents required · 16 mandatory
₹0
₹38,147
ELECTRICAL DIVISION-3/DDA
13 Aug 2026
22 Jun 2026
7 Jul 2026
22 Jun 2026
6 Jul 2026
23 Jun 2026
23 Jun 2026
This is a percentage-rate BOQ. The schedule below shows estimated quantities and rates. Bidders quote a single percentage above or below the total estimated cost.
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Running operation of CCTV operation shall be done by deploying 2 no. operator (Grade-I) in general shift from 10 am to 6 pm as per additional condition attached.1 no.operator for PVSC and 1 no. operator for VKSC & BGNSC. | 12 | Per Months | 83,895 | ₹10,06,740 |
| 2 | Comprehensive Running Maintenance of CCTV (Surveillance), PA, Key Telephone and Data Networking system with assoceries installed at various locations at VKSC & BGNSC Annexure-A (Inventory of equipment), terms and conditions attached. etc. complete as required. | 12 | Per Months | 31,860 | ₹3,82,320 |
| 3 | Comprehensive Running Maintenance of CCTV (Surveillance), PA, Key Telephone and Data Networking system with assoceries installed at various locations at (Paschim Vihar Sports Complex) Annexure-B (Inventory of equipment), terms and conditions attached. etc. complete as required. | 12 | Per Months | 33,276 | ₹3,99,312 |
| 4 | Supplying and drawing of 3C 2.5 SQ MM SOLIDr ARMOURED CABLE XLPE Copper POWER CABLE as required. | 200 | Per Meter | 136 | ₹27,200 |
| 5 | Online UPS - Input supply: Single Phase, Output Supply: Single Phase.
Supplying, installation, Testing & Commissioning of following capacity at full load (Unity Power Factor)
ON LINE Uninterrupted Power Supply (UPS) system suitable for Single Phase input, Single Phase output AC Supply. The UPS shall include a Rectifier, inverter, battery bank suitable for 30 minutes back up (Battery VAH capacity shall not be less than 1600 VAH per KVA of UPS rating per Hour backup time) on full load (Battery shall be VRLA, SMF in ABS Container) and Static Bypass switch along with provision for manual bypass, suitable isolation transformer for additional protection against neutral faults etc. The UPS systems shall be Microprocessor based Digital Control, using Insulated Gate Bipolar Transistor (IGBT)'s both for the rectifier & inverter with PWM (Pulse Width Modulation) Technology. The quality of design,
manufacturing and inspection process should confirm to the relevant Inter-national standards suchasIEC/EN/VDE. The operating efficiency of the UPS systems shall be >95% at 100% non-linear
loads. Current total harmonic distortion(ITHD)/ total demand distortion (TDD) on the input grid shall be
< 5% at 100 %load. (The required LC filters shall be included in UPS cost), extreme power factor kit to be
include to limit the input pf to 0.99 and output power factor shall be unity (i.e. kw rating of the UPS shall
be kva rating x 1 ) however UPS shall be suitable to take load at 0.7 laging to 0.7 leading power factor
loads. UPS shall be suitable for incoming supply AC single phase 160-270V 50 Hz and delivering output AC supply true sine wave single phase 220/230/240 Volt, 50 Hz +/- 0.2Hz, Overload capacity of 120% for 10 mins and 150% for 1 minute. Operating temperature 0 to 40 0C, Relative humidity 0-95% non condensing, noise level less than 60db at 1 meter distance, Protection for Under voltage, over voltage, abnormal output voltage, battery over charging, output over current, short circuit, battery deep discharge , 10 KV surge. Display for watt/VA,Amp and Voltage power parameters etc. UPS shall comply with low voltage electromagnetic compatibility (EMC) achieved as per EN 6204, EN6204 Part I and Part 2, it shall be a Voltage and Frequency Independent (VFI) type UPS (as per standard IEC 62040-1, 2 & 3) . The UPS should be with IGBT Based Inverter Technology, Communication RS232/ RS485/ SNMP port open protocol for BMS integration as per approved by Engineering in charge. Required battery racks, DC breaker of suitable rating and interconnecting copper conductor cable of suitable size and connectors and all required accessories are inclusive in the cost. The UPS should have QR code which should contain drawing, test report OEM manual, Geo- Tag of manufacturing location etc (DSR_2025)
(2KVA) | 2 | Each | 45,894 | ₹91,788 |
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 2.52 MB
BOQ_960774.xls
BOQ • 0.25 MB
NIT11n.pdf
Tender Documents • 4.51 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .