Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹1.1 CrAccepted-AOC D1C 47A JANAK PURI NEW DELHI 110058 | NEW DELHI | DELHI | DELHI | 110058 | ₹1.1 Cr | L-1 | Accepted-AOC Being lowest bidder |
| 2 | L-2₹1.1 Cr+₹8,708 (0.08%)Rejected-Finance OFFICE 4 9 SWARG ASHRAM NANAK RAM COLONY PARMANAND CHOWK DELHI 110009 | DELHI | DELHI | DELHI | 110009 | ₹1.1 Cr+₹8,708 (0.08%) | L-2 | Rejected-Finance Not being lowest bidder |
| 3 | L-3₹1.3 Cr+₹16.7 L (15.0%)Rejected-Finance 3788 SHAH GANJ GB ROAD NEW DELHI 110006 | NEW DELHI | DELHI | DELHI | 110006 | ₹1.3 Cr+₹16.7 L (15.0%) | L-3 | Rejected-Finance Not being lowest bidder |
| 4 | L-4₹1.3 Cr+₹20.6 L (18.5%)Rejected-Finance | ₹1.3 Cr+₹20.6 L (18.5%) | L-4 | Rejected-Finance Not being lowest bidder |
Tender Value
₹1.4 Cr
EMD Value
₹2.1 L
Closing Date
29 May 2023, 6:00 pmClosed
CE RND Delhi
HQ CE RND Probyn road Timarpur Delhi-110054
ADDITION/ALTERATION OF CRYSTAL GROWTH BUILDING NO P41 AT SSPL DELHI UNDER GE (I) RND DELHI
2023_MES_590281_1
CE RND /DLI-02/DLI/2023-24
Open Tender
Civil Works
Item Rate
457 days
Delhi
Please refer tender documents
8 documents required · 8 mandatory
₹1,000
GE I RND DELHI
₹2.1 L
Yes
23 Jun 2023
19 Apr 2023
3 Jun 2023
19 Apr 2023
29 May 2023
15 May 2023
Amount
Demolition of plain cement concrete in ground floors and pavings n exc 15 cm thickness (below or above ground level) complete all as specified and directed by Engineer-in-Charge.
Demolition of Brickwork or stone/ boulder masonry, built in cement mortar including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stonework and precast concrete articles complete all as specified and directed by Engineer-in-Charge.
Taking down chowkhats with shutter without taking off shutters from the frames of door/windows/ventilator etc (area exc. 1.50 sqm but n. exc. 4.00 sqm each) incl making good the disturbed surfaces complete all as specified & directed.
Taking down chowkhats with shutter without taking off shutters from the frames of door/windows/ventilator etc (area n. exc. 1.50 sqm each) incl making good the disturbed surfaces complete all as specified & directed.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified and directed by Engineer-in-Charge.
M&L Roughening surfaces of old concrete floor by picking, sweeping clean and washing down with water to remove dust, etc complete all as specified and directed by Engineer-in-Charge.
Taking down cement plaster any description on brick/concrete surfaces etc including raking out joints hacking for key, scrubing down with water etc complete all as specified and as directed.
Removal of demolished material/Debris/Malba generated from respective item of BOQ shall be revove outside MoD Land inluding loading, unloading and stacking at the destination wherever, decided by contractor complete all as specified and directed. Note: Necesary approval & charges of Municipal corporation or any othe authority like NGT/Police etc if equired shall be taken by the Contactor at his own end. Contractor shall be solely esponsible for the same. The rates are inclusive for the same.
Material & Labour for Plain Cement concrete type B-0 (1:2:4) using 12.5 mm graded crushed stone aggregate as in seismic and other similar bands, shelves, copings, bed plates, hold fasts, plinth courses, chajjas, string courses,lacing courses, parapets and railings upto 60 cm in height,copings, kneelers, apex stones,bed plates, filling in pressed steel frame and the like finished fair and even incl necessary form work complete all as specified & directed.
M & L for PCC (1:4:8) type D-2 using 40mm graded stone aggregates for sub bases of floor, mass concrete finished even and rough to receive topping layer completed all as specified and directed by Engineer-in-Charge.
M&L PCC (1:3:6) type C-2, using 40mm graded stone aggregate as in plinth protection 75mm thick laid in bays and surfaces finished even & smooth without using extra cement complete all as specified .
Material and labour for brick work with sub class ‘B’ bricks of class designation 7.5 all as per IS-1077-1992 (minimum compressive strength of brick 75 kg / Sqcm) old size bricks, straight or curved on plan exc 6 metre mean radius built in cement mortar 1:6 complete all as specified & directed.
M&L Brickwork with subclass ‘B’ bricks, straight or curved on plan to any radius in half brick thick walls built in CM 1:6 complete as specified and directed by Engr-in-charge.
M&L for joint free glazed coloured ceramic coloured tiles of 300mm x 450mm x 7mm thick on vertical surface of walls set and jointed with neat cement slurry and pointed in white/coloured cement to match the shade of tiles, over and including 10mm thick rendering in CM 1:4, all as specified and directed by engr-in charge.
M&L non-skid, ceramic coloured tiles 7 to 8mm thick (Square/rectangular ) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, in floors, set and jointed in cement slurry and pointed in white or coloured cement to match with the shade of tiles over and including screed bed 15mm thick average in cement mortar 1:6 complete all as specified & as directed.
M&L for Vitrified Ceramic (light shade) tiles 8 to 9 mm thick (square/ rectangular) polished, area of each tiles not exceeding 0.36 sqm, in floors etc. set and jointed in neat cement slurry, over and including 15 mm thick screed bed in CM 1:6 and pointed in white or coloured cement to match complete all as specified & as directed.
M&L for Vitrified Ceramic (light shade) tiles 8 to 9 mm thick (square/ rectangular) polished in skirting/vertical surfaces set and jointed in neat cement slurry over and including 10 mm rendering in CM 1:4 pointed in white or coloured cement to match complete all as specified & as directed.
Dismantling wall panelling and ceiling boards/ False ceiling board including snap grid etc (fibre pulp, insulation etc) or insulation boards/slabs/blankets any thickness incl cover fillets complete all as specified & as directed.
S&F Anodised aluminium snap grid frame work for false ceiling and hangers 6mm dia GI (upto 1200mm length) adjusting level fixed to roof slabs by means of ceiling cleats made out of GI flat 40 x 3mm size 60mm long and expansion hold fasteners 12.5mm dia, 40mm long complete all as specified and directed by Engr in Charge
S&F 8mm thick exposed metal frame ceiling with calcium silicate board of siliceous and calcareous material reinforced with cellulose fibre for fixing in 600 mm x 600mm grid (Frame work for ceiling shall be measured and paid separately) all as specified and directed by Engr in Charge
M&L 15mm thick rendering in cement mortar 1:6 on fair faces of new or old brick works or concrete work finished even & fair without using extra cement complete all as specified and as directed.
M&L 15mm thick rendering in cement mortar 1:4 on other than fair faces of new or old brick work or concrete work, finished even & smooth without using extra cement complete all as specified and as directed.
M&L 5mm thick rendering in cement mortar 1:3 on ceiling new or old brick works or concrete work finished even & fair without using extra cement complete all as specified and as directed.
M&L preparation of newly plastered surface/ old plastered surfaces of wall and applying 2mm thick Birla white/JK white wall care putty (1mm thick in each coat), to give an even finished smooth surface and preparing the surface for white wash /distemper /cement base paint/Apex paint etc complete all as specified and directed.
M&L preparation of newly plastered surfaces of walls including all cornices, pilasters etc and applying two coats of acrylic exterior emulsion apex paint (weather proof) of approved tint / shade(s) over and including one coat of water based alkali resistant primer complete all as specified and directed.
M&L preparation of newly plastered surfaces of walls and applying two coats of oil bound distemper (white or tinted) over a coat of alkali resistant primer complete all as specified and directed.
M&L preparation of newly plastered surfaces of ceiling and applying two coat of oil bound distemper(white or tinted) over a coat of alkali resistant primer, complete all as specified and as directed.
M&L for Complete removal of existing treatment including preparation of plastered or unplastered old decorated surfaces of walls incl pillasters and cornices etc. incl washing, rubbing down and stopping the previously treated surfaces and applying two coat of oil emulsion distemper of approved shade/tint complete all as specified & directed.
M&L for Complete removal of existing treatment including preparation of plastered or unplastered old decorated surfaces of walls incl pillasters and cornices etc. incl washing, rubbing down and stopping the previously treated surface and applying two coat of acrylic exterior emulsion apex paint (weather proof) of approved tint / shade(s) over and including one coat of water based alkali resistant primer complete all as specified and directed.
Demolition of reinforced Concrete of any description and in any position not otherwise specifically provided for including cutting of reinforcement complete all as specified and as directed.
M&L Reinforced cement concrete type B1 1:2:4 using 20mm graded crushed stone aggregate (nominal mix ) as in Slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like complete all as specified and directed by Engr-in-charge
S&F mild steel TMT reinforcement bars 10mm dia and over, cut to length, bent to shape required incl cranking, bending spirally for hoping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and as directed.
Use and waste formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (Horizontal or sloping) complete all as specified and directed by Engr-in-charge.
Supply & fix in repairs vitreous china oval type wash hand basin (under/over counter), white flat back, size 550mm x 460mm including waste coupling 32mm dia, with fly nuts, pvc waste pipe and MS brackets 25x25x5 mm thick including granite work required for counter, cutting for and pining in ends of brackets, complete all as specified & directed.
S&F in repair brass CP Pillar taps, cast copper alloy, fancy type with capstan heads, chromium plated, screwed down high pressure, with or without lettered 'Hot' or 'Cold' with long screwed shanks and fly-nuts, screwed for iron pipe and fixed complete all as specified and as directed.
S&F in repair PVC connections 15mm size with PTMT nuts of length 600mm fixed in position complete all as specified and as directed.
Supply and fixing aangle valve brass, chromium plated ,screwed down, high pressure with crutch or butterfly handle screwed for iron pipe or for union, suitable for 15mm bore pipe, fixed as in repair complete all as specified and directed.
Supply and fixing in repair PVC valve less syphonic action type flushing cistern low level white with PVC in let ball valve, float and handle, 10 ltrs capacity and 32mm dia PVC bend for required squat pattern including fitting and flush pipe etc, set with concrete and making good to floor, complete all as specified & directed.
S & F in repairs vitreous china pedestal pattern, "EWC" white with connection to trap, and to flushing pipe anti-syphonage pipe and including sheet cover and CP jet etc. complete all as specified and directed.
S&F in repair white Vitreous China Urinal, Half stall type, complete including providing and fixing plugs, bedding urinal against wall in cement mortar 1:2, securing urinal to plugs with and including 60mm long brass screws, pointing around urinal back in cement; including CP urinal Spreader with brackets, and , Waste coupler complete all as specified and as directed.
M&L cutting chases, pinning in brick walls and making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps cills etc or for concealed water tubing or concealed conduit wiring etc cutting not exc 10 cm width or girth complete all as specified and as directed.
Supply and fixing as in repair Bib taps fancy type,chromium plated cast copper alloy with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule and fixed, suitable for 15mm bore pipe, complete all as specified and directed.
Supply and fixing long body Bib taps,chromium plated cast copper alloy with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule and fixed, suitable for 15mm bore pipe, fixed as in repair complete all as specified and directed.
S&F 20mm bore GI tank connection Nipple suitable for HDPE water tank for inlet and outlet connection in tank (Minimum weight 20mm-45gms ) complete all as specified and as directed.
S&F Ball valves high pressure of PTMT (Min wt 210 gm) with epoxy coated Aluminium rod & high density plastic ball screwed for iron pipe and fixed for 20mm bore pipe, complete all as specified and directed.
Dismantling water tanks and removing from site of 1000 litres capacity complete all as specified and directed.
Suppply and hoisting 1000 litrs capacity rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) HDPE double layered , cylindrical type, fixed and hoisted in position on roof at any height all as specified in SSR Part I complete with inlet/outlet of 20 mm GI Pipe connection including 20mm Gun metal gate valve at inlet and outlet connection complete all as specified and directed.
Complete revoval of existing wate proofing treatment including PCC padding / brick tiles/ brick coba and Mud Phaska etc. without damaging the eixisting slab complete all as directed and M&L for preparation of surfaces to achieve clean and sound concrete surfaces float finished and free from cavities and projecting nibs. All substrates should be dry clean and free of dust, plaster, oil,paint, grease, corrosion, deposits, and any other deleterious substances. Crackes/honey comb will be repaired by chasing open the area minimum 20mm depth in V-groove shape. All the chased substrate should be sound and cleaned using water. Smooth substrate must be mechanically roughened to provide an adequate key applying bond coat on the prepared surface with Nitobond SBR latex of FOSROC/smartcare repair polymer SBR latex of Asian paints/pidilite (Dr. Fixit Super Latex) or equivalent of Sika mixed slurry coat (1 SBR:1water:3 Cement). Reinstallement polymer modified mortar shall be complete within the overlay time of bonding coat. Later reinstating the chased area with Nitobond SBR latex admixed PMM, of FOSROC/Smartcare Repair polymer SBR latex admixed PMM of Asian paints/Pidilite (Dr. Fixit Pidicreate URP) or equivalent of sika inculding finsihing, curing, complete all as per manufacturer's instruction and directed by Engr-in-Charge. Bore packing:- Opening the periphery of the existing frains minimum 20 mm depth and sealing the same with high strenth non shrink epoxy mortar like Nitomortar S of FOSROC/APCOREP Epoxy Mortar of Asian paints/ Pidlilite (Dr. Fixit Expoxy Mortar) or equivalent in sika in the gap around drainage pipes (between pipe and concrete) complete all as per manufacturer's instruction and directed by Engr-in-Charge.
M&L for Injecting nozzle packing: Drill and fixing injection packers in RCC members for cementitious grouting, drilling holes in structural members at the intervals as per recommendation/requirements, cleaning the holes by air blower prior to fixing nozzles. Insert 12 mm dia, 50-75mm long PVC or equivalent injection packers in cleaned holes with fast setting mortar like Renderoc Plug of Fosroc or equivalent in Asian paints/sika/pidilite. Cut the packers by cut of wheel after completion of the grouting without damaging structural elements. Injection Grounting: Supply and applying with pressure (mechanical means) plasticuised expanding grout admixed cementitious grouts Cebex 100 of FOSROC or equivalent in Sika/Pidilite/Asian paints having chloride contents-Nil as per BS:5075, Typical unrestrained expansion of upto 4% in general.The admixed should be mixed @225 gms per 50 Kg of cement.
M&L for hacking up the corners using suitable mean, later cleaning the same using water, followed by the application of Nitobond SBR latex or smartcare Repair polymer equivalent in Sika/pidilite/mixed slurry coat (1SBR:1water:3 cement) & later filling and making 100 mm x100mm concave coving using Nitobond SBR latex admixed PMM of FOSROC/smartcare Repair polymer SBR latex admixed PMM of Asian Paints or equivalent of sika/pidilite, including finishing, curing, all complete all as specified and directed
M&L for Waterproofing Treatment over mother slab by Providing and applying 2 layers of FOSROC proofex Torchseal-3PI strandard or Asian paints smartcare APP membrane or equivanet in Sika/pidilite-3mm thick Non-woven polyster mat reinforced APP modified bituminious membrane. The system is applied in double layers (one in x-direction, other in y-direction). Membrane to be overlapped for 100 mm sideways and 150 mm at the end laps with each having followings specifications: a. Membrane thickness :3 mm (+/-10%) b. Tensile strenth ASTM D5147: >400N/5 CM(L&T) c. Tensile tear strenth ASTM D4073: 200N/5 CM d. Resistance to water pressure-DIN 52123: No Leak e. Elongation ASTM D5147 f. Water tightness (EN 1928-1) kPa: 60m System included Priming the substrate with Proofex Torchseal Primer/proofex smartcase bitumen Primer or equivalent in sika/pidilite (at consumption 0.4 litres/sqm), Provision and application of 3mm thick Proofex torchseal of fosroc/smartcare app membrane of Asian paints or equivalent in sika/pidilite in double layer and termination of the membrane at 450 mm from the roof level in groove of 50mmx50mm filled with Nitoseal PU 50 of Fosroc or smartcare hybrid PU sealant or equivalent in sika/pidilite
M&L for providing and installing 300 GSM non-wooven geotextile membrane as a protection layer over the finish waterproofing treatment prior to protection screed complete all as specified and directed.
M&L for providing and laying PCC of M20 grade mixed with approved water proofing compound like Conplast WLXtra of fosroc or smartcare VltaliaNEO of Asian paints or equivalent in sika/pidilite an advanced technology based, corrosion resistance admixed as per ASTM G1, IS 2645, JISZ 1535 mixing @ 200 ml/bag of cement, includig control joints (6mm wide and 10 mm deep) at every 3mx3m panel size, making angle fillet of 75mmx75mm using M20 grade concrete at the corners.
M&L for induced control joints as in roof filling in the screed concrete with sealant Fosroc nitoseal PU50/ Asian paints smartcare PU sealant or equivalent in sika/pidilite.
Providing and applying 15 mm thick cement plaster proportion 1:4 admixed with integral waterproofing admixed conplast WLXtra of FOSROC ot smartcare VLtaliaNEO of Asian paints or equivalent in Sika/pidilite an advanced technology based, corrosin resistance admixed as per IS2645, ASTM G1, JISZ 1535 mixing @ 200ml/bag of cement. This shall include all chamfering, rounding off of corners, protrusion and shall include shutttering cost or as per Engineer-in-charge specification. Cement and sand will be in client scope. Note for Sr item no 48 to 51.40 :- (a) MoU will be done by the contractor with the one of the above OEM for carrying out water proofing treatment . (b) The roof treatment works shall be carried out through a specialized and authorized applicators of OEM only
Taking down 15mm steel water tubing and connections, including removing from site complete all as specified and directed.
Taking down 20mm steel water tubing and connections, including removing from site complete all as specified and directed.
Supply and fixing 15mm bore tubes "medium grade" galvanized with and incl all fittings complete to walls and ceiling or laid in floors complete all as specified & directed..
Supply and fixing 20mm bore tubes "medium grade" galvanized with and incl all fittings complete to walls and ceiling or laid in floors complete all as spd & directed.
S&F Solid PVC door frame of size 50mmx 47 mm made out of 5 mm plain colour PVC sheet reinforced with MS square tube all as per specification and drawing complete all as specified and as directed.
M&L factory made solid panel pvc door shutter 30mm thick (style) consisting of frame made out of MS tubes for top and bottom rails MS frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail lock rail & bottom rail on either side and as gap insert for top rail & bottam rail . paneling of plain colour PVC sheets to be filted in MS frame welded, sealed to the stiles and rails with suitable PVC sheet beading, and jointed together with the solvent cement complete all as spd.
S&F 150 mm size aluminium anodised, barrel tower bolts of extruded section and fixed complete all as specified and as directed.
S&F 150 mm size extruded aluminium alloy handles, fabricated type, anodised complete all as specified and as directed.
S&F 100 mm long Butt hinges, extruded aluminium alloy, type B-21 with galvanised mild steel hinge pin, anodised and fixed complete all as specified and as directed.
M&L for providing and fixing Powder coated aluminium (minimum thickness of powder coating 50 micron) work for doors, windows, ventilators and partitions (Fixed portions) with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS:733 and IS:1285, fixing with dash fasteners of required dia and size,including necessary filling up the gaps at junctions, i.e. at top,bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle,Aluminium snap beading for glazing/ paneling, C.P. brass/ stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-Charge.
S&F anodised aluminium powder coating aluminium section weighing not less than 0.55Kg/m {minimum thickness of powder coating 50 micron)frame for doors, windows, ventilators with one or more rebates including joining cleat for fixing etc complete all as specified
S & F Powder coated aluminium door shutters,aluminium section weighing not less than 0.55 kg/m including necessary joining cleats,glazing clips, ruber neoprene packing, handles 2 Nos in each door, hinges,anodised aluminum snap beading screws, and all necessary builder hardware etc. complete all as specified and directed
S&F Powder Coated aluminium window and ventilator shutters, fixed type without sash bar, aluminium section weighing not less than 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws and all necessary builder hardware etc. complete all as specified
S&F aluminium section powder coated (powder coating not less than 50 micron thick) grill of size 6 x 4.5 mm thick section 10cm centre to centre spacing fixed to the existing window frame with C.P. brass/ stainless steel screws @ 200 mm centre to centre, including cutting the grill to proper opening size for fixing and operation of handles complete with U-channel all around fixed in window with screws complete all as specified and directed
S&F 12 mm thick prelaminated particle board exterior grade with decorative prelaminated both sides of approved shades fixed to aluminium shutters/partitions etc complete all as specified and as directed.
S&F 4.8 mm thick sheet glass ordinary quality, area exc 0.50 Sqm each pane and fixing by means of glazing pins and rubber beading etc in aluminium partitions, windows, doors etc complete all as specified and as directed.
S&F 4.8 mm thick sheet glass ordinary quality, area not exc 0.50 Sqm each pane and fixing by means of glazing pins and rubber beading etc in aluminium partitions, windows, doors etc complete all as specified and as directed.
S&F solar control film 25 micron reflective type sticked to glass panes as per manufacturer's instructions complete all as specified and as directed
M&L for Providing and injecting chemical emulsion for Post Constructional Antitermite Treatment along external wall where the apron is not provided using chemical emulsion at the rate of 7.5 litres per sq.m of the vertical surface of the sub-structure to a depth of 300mm including excavating channel along the wall and rodding etc. complete all as specified and directed
M&L for Providing and injecting chemical emulsion for Post Constructional Antitermite Treatment along the external wall below concrete or masonry apron using chemical emulsion @ 2.25 litres per linear metre including drilling and plugging holes etc. in apron complete all as specified and directed.
M&L for Providing and injecting chemical emulsion for Post Constructional Antitermite Treatment of soil under existing floors using emulsion @ one litre per hole, 300mm apart including drilling and plugging 12mm dia holes with cement mortar 1:2 (1 cement: 2 coarse sand) to match the existing floors complete all as specified and directed.
M&L for Providing and injecting chemical emulsion for Post Constructional Antitermite Treatment of voids in masonry using chemical emulsion one litre per hole, at 300mm intervals including drilling holes at 45 degree and replugging them with cement mortar 1:2 (1 cement : 2 coarse sand) to match the existing floors complete all as specified and directed.
M&L for Providing and injecting chemical emulsion for Post Constructional Antitermite Treatment at points of contact of wood work by chemical emulsion (in oil or kerosene based solution) @ 0.5 litre/hole by drilling 6mm dia holes at a downward angle of 45 degree at 150mm centre to centre and sealing the same complete all as specified and directed.
M&L for chipping of spalled and loose concrete and cleaning rust from reinforcement by sand blasting scrubing down concrete surfaces with wire brushes cleaning with water allow to dry and applying a layers of Zinc rich epoxy primer as an antirust on all exposed reinforcement followed by a layer of bounding coat of approved epoxy adhesive on complete exposed surfaces of concrete to be gunited all as specefied and applying two layers of guniting over steel and including welded mesh 2 mm dia of wire and aperture 75 mm,total thickness of guniting not exc 40 mm (Avg thickness) in Cement mortar 1:2 using OPC 53 grade cement mixed with polycreate mixture @2% by weight of cement or as per menufacturer istructions and finally appling cement plaster over guniting surface of required thickness to give even,uniform and smooth finishes confirming to proper geomtrics in cement mortar 1:3 to match the existing surfaces as in sides ,soffits of the slabs,chajja,fins,facia,parapets,lintels,columns and beams etc complete including necessary scaffolding ,shuttering,chasing to brick work or RCC members at any hieght up to 06 storied buildings including removal of all small trees/shurbs etc. complete all as specified and directed.
S&F in repairs PVC waste pipe 32mm size for WHB, urinals etc complete all as specified and directed
S&F CP Grating doom 100mm dia (Minimum weight 25gms) complete all as specified and directed.
S&F CP grating doom 125 mm dia with waste hole. (Minimum weight 40gms complete all as specified and directed.
Supply and fixing Stainless steel wire cloth 0.56mm nominal dia of wire and avrg widh of aperature 1.18mm incl fixing to wooden/steel frames with tinned tacks or galvanised wire or wooden bead complete all as specified & directed.
S&F CP brass Soap dish, any type, fixed to plug with chromium plated brass screws complete all as specified and directed.
S&F brass, chromium plated tubular towel rail, 20mm dia, D type, 60cm long between flanges complete all as specified and directed.
Demolition and breaking up drain pipes of 100mm/ 150 mm internal dia ( Salt glazed ware, AC or Reinforced concrete, PVC pipe or CI ) set in cement mortar complete all as specified and directed.
Demolition and breaking up drain pipes of 75mm internal dia ( Salt glazed ware, AC or Reinforced concrete, PVC or CI pipe ) set in cement mortar complete all as specified and directed.
S&F PVC (SWR) pipes single socketed 75 mm outer dia in any length with rubber ring joints laid in trenches or in floors complete all as specified and directed.
S&F plain PVC (SWR) bend suitable for 75 mm dia pipe complete all as specified and directed.
S&F PVC (SWR) pipes single socketed 110 mm outer dia in any length with rubber ring joints laid in trenches or in floors or fixed to walls as required complete all as specified and directed.
S&F plain PVC (SWR) bend suitable for 110 mm dia pipe complete all as specified and directed.
M&L preparation of old painted wooden surfaces of any description over 10 cm width or girth and applying one coat of synthetic enamel paint of tint / shade as approved complete all as specified and directed.
M&L preparation of old painted wood or wood based surfaces of any description not otherwise described over 10 cm width or girth and applying one coat for finishing with synthetic varnish polish over and including a filler coat of transparent liquid wood filler in one or more coats to achieve glossy finish complete all as specified & directed.
M&L for preparation of old painted steel or iron surfaces of any description n exc 10cm width or girth and applying one coat of synthetic enamal paint of tint as approved complete all as specified and directed.
S&F in repair Stainless steel sink, 1.00mm thick for kitchen or laboratory with plug waste pipe, washers including cantilever cast iron brackets connecting union etc. overall size 495mm x 420mm with bowl size 410mm x 330mm x 160mm complete all as specified and directed.
Supply and fixing toughned glass 10 mm thick as in hinged doors, partitions automatic doors and similar work including cutting to shape ,drilling holes required complete all as specified and directed.
S&F in repair vertical venetian blinds consisting of Aluminium head rail with vanes/louvers 100 mm wide of approved tint and travers coard complete fixed in position all as specefied and directed by Engr-In -charge.
Dismantling stone slabs and tiles of any description or thickness in floors, aprons etc laid bedded and pointed in any mortar etc all as specified and directed by Engr-in Charge.
M&L Granite (of any type) tiles 20mm thick machine cut bedded and jointed with grey cement slurry and pointed with white cement with admixture of pigment to match the shade of granite stone including cutting,rubbing, and polishing surface and rounding of edges complete over and including 20 mm thick screed bed in CM 1:4 complete all as specified and directed.
M&L Granite (of any type) tiles 20mm thick machine cut in skirting/dado laid over and including 10mm thick rendering in CM 1:4 with grey cement slurry and pointed with white cement with admixture of pigment to match the shade of granite stone including including cutting,rubbing, and polishing surface and rounding of edges complete all as specified and directed.
Demolition of cement Concrete of any description and in any position not otherwise specifically provided for all as specified and as directed.
M&L 100 mm thick cement concrete type D-2,1:4:8 (40mm graded stone aggt) as in sub floors, filling and mass concrete etc complete all as specified.
M & L for Factory made Rubber moulded precast concrete interlocking paver block (coloured),pre polished of any shape and size with white cement and pigment confirming to IS 15658-2006 of 60 mm thickness M-35 Grade complete all as specified and directed.
M&L for 50mm thick sand cushioning laid over PCC(1:4:8) fully compacted by watering and providing gradient as specified by Engr - in- charge complete all as spfd and directed.
M&L type B1 1:2:4 20mm graded aggregate) providing, cement concrete in roof kerb or mud stops, rounded or chamfered on edge in lintels upto 1.5mm clear span, cills, steps, seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railing upto 60cm in height, copings, kneelers, apex stones, bed plates, kerb not providing for in them 04028, water troughs and the like including weathering , slightly rounded or chamfered angles and throating as directed.
Taking down of old unserviceable copper / aluminium point wiring (light, fan, socket or power) complete including fitting & fixture such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc removing materials and making good disturbed surfaces of walls, floors etc complete.
M&L Point wiring with multistranded copper conductor PVC Insulated and unsheathed cable in PVC conduit concealed type 1.5 sqmm FRLS with all fittings /accessories and including 1.5 Sqmm PVC insulated copper earth wire connected common earth with terminal boxes for Moduler fittings including acessories as moduler surface cover plate with frame, metal flush box, for one light/Fan/Exhaust Fan point complete.
Description all as per srl item No 104 here- in- before but using cable size 1.5 Sqmm for 1 No 05 Amps Socket on same board with terminal boxes, Moduler fittings including acessories as moduler surface cover plate with frame, metal flush box,complete all as specified and as directed..
Description all as per srl item No 104 here- in- before but using cable size 1.5 Sqmm for 1 No 05 Amps Socket outlet independent with terminal boxes, Moduler fittings including acessories as moduler surface cover plate with frame, metal flush box,complete all as specified and as dierected.
Description all as per srl item No 104 here- in- before but using cable size 2.5 Sqmm for one three pin switch socket outlet 15 Amps point with terminal boxes, Moduler fittings including acessories as moduler surface cover plate with frame, metal flush box, complete all as specified and as directed.
S&F sheet metal enclosure with socket plug top and MCBs Triple pole and earth enclosure with 3 pin and earth plug with socket complete with one Triple pole MCB 63 Amps complete.
S&F sheet metal enclosure with socket plug top and MCBs single pole and neutral enclosure with 2 pin and earth plug with socket complete with one single pole MCB 20 Amps complete all as specified and directed.
S&F in replacement Modular switch single pole 1 way 6A, 1 Module complete all as specified and directed.
S&F in replacement Modular switch single pole 1 way 16A, 1 Module complete all as specified and directed.
S&F in replacement Modular socket 6A 2/3 pin combained 2 module complete all as specified and directed.
S&F in replacement Modular socket 6A/16A- 2/3 pin combained 2 module complete all as specified and directed.
M&L Ceiling rose ,3 phase /PVC/polycarbonate,isolated body
M&L for Taking down of exhaust fan of any type/ size, , single phase, 240 volts AC, greasing/oiling, and including replacement of unserviceable accessories i.e. bearing, condensor, fan blade etc and making all electric connections complete all as specified and directed by Engr-in-Charge.
Supply and fixing LED luminaire 600 mm x 600 mm, 35/36 watt, 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete.
Supply and fixing LED lights fitting 1x 20W, 220V,AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete.
Supply and fixing LED street light fitting 60 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete.
Supply and fixing in replacement of VTPN DB 12 ways vertical type suitable for MCCB incomer upto 250 Amps single door complete all as specified and directed by Engr-in-Charge.
Supply and fixing in replacement of VTPN DB 8 ways vertical type suitable for MCCB incomer upto 250 Amps single door complete all as specified and directed by Engr-in-Charge.
M&L in replacement MCCB 4 Pole, 415 V, Adjustable type, 160 Amps with breaking capacity 36 KA
M&L in replacement MCCB 4 Pole, 415 V, Adjustable type, 100 Amps with breaking capacity 25 KA
Supply and fixing MCB SP rating 240V, 10KA 'C' curve complete with connection testing and commissioning complete all as specified and directed.
Supply and fixing MCB 63 amp TP rating 415V, 10KA 'C' curve complete with connection testing and commissioning complete all as specified and directed.
M&L for sub main wiring with four run of single core PVC insulated FRLS stranded copper conductor cable of size 16 Sq mm and two run of 16 Sq mm earth wire in PVC insulated FRLS copper conductor cable as earth continuity conductor drawn in and including PVC conduit concealed medium grade complete all as directed. Note: 6 run of 16 sqmm single core PVC copper cable and 01 run of PVC conduit shall be measured as on unit.
M&L for sub main wiring with four run of single core PVC insulated FRLS stranded copper conductor cable of size 6 Sq mm and two run of 6 Sq mm earth wire in PVC insulated FRLS copper conductor cable as earth continuity conductor drawn in and including PVC conduit concealed medium grade complete all as directed. Note: 6 run of 6 sqmm single core PVC copper cable and 01 run of PVC conduit shall be measured as on unit
S&F DLP trunking system plastic adoptable type 105X50mm with 2 compartment duly covered installed with suitable mosaic support joints including all accessories complete all as specified and as directed.
S&F Telephone socket RJ11 complete all as specified and directed.
S&F in replacement of fan step regulator, 120W, 2 Module complete all as directed
M&L for earthing complete with galvanised steel earth plate electrode 600mm×600mm.× 6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less'than 1.5 metres below normal ground level, connected to galvanised earth lead wire 4.0mm dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 3 connected to earthing test point all as specified or indicated including testing on completion
M&L for earthing continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing as required 4mm dia galvanised iron or steel wire.
S&F telephone cable in concealed PVC conduit including connecting in telephone socket complete.
Supply and laying in replacement XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 185 Sqmm 3.5 core including suitable size Aluminium lugs properly crimpled with crimping tools including testing complete all as specified and directed
All as per item srl No 133 above but cross-sectional area 35 Sqmm 3.5 core complete all as specified and directed.
All as per item srl No 133 here-in-before above but cross-sectional area 50 Sqmm 3.5 core complete all as specified and directed.
Excavation in trenches in soft/loose soil not exceeding 1.5m depth & not exceeding 1.5m in width over energised LT cables for carrying out brick work for preparation of cable duct including for taking out and relaying of LT Cables complete all as specifed & directed
Excavation in trenches in hard/dense soil not exceeding 1.5m depth & not exceeding 1.5m in width over energised LT cables for carrying out brick work for preparation of cable duct including for taking out and relaying of LT Cables complete all as specified & directed
Returning filling in including spreading levelling watering and well ramming in layers not exceeding 25cm thick as in soft/loose soil complete all as specified and directed.
Removing excavated soil to a distance not exceeding 50 mtr and depositing where directed at a level and not exceeding 1.5 mtr above the starting point complete all as specified and directed.
M&L for PCC (1:4:8) type D2 using 40 mm graded stone aggregate for fixing of pole complete all as specified and directed.
M&L for PCC (1:3:6) type C1 using 20 mm graded stone aggregate for coping of pole complete all as specified and directed.
Supply & laying dry fine sand for cushioning of underground cable laid in trenches/duct complete all as specified and as directed. Note : Punned thickness shall be measured.
Supply and laying in trenches burnt brick sub class 'B' standard size for cable protection keeping width of the brick parallel to the length of the cable complete all as specified and directed.
Supply and laying GI pipe light grade size 80 mm dia fixed on wall/laying in trench including all connected fitting/acessories including taking old unserviceable complete all as specified and directed
M&L for boring of holes under road, pavement, hard standing by manually to pass upto 80sqmm
Taking shutdown, dismantling of existing LT panel complete and S&F in replacement Indoor type cubical panel board suitable for 3 phase, 4 wired, 415V, 50 Hz and tested at CPRI for 35 MVA rapturing capacity at 415 volts factory fabricated in an approved factory with CRCA sheet of 2 mm thick having modern fabrication process powder coating in approved shade having thickness not less than 100 microns provided with suitable gasket to make it dust and vermin proof and general constructions conforming to IS : 8623/93. The LT Panel shall be front and back openable and having inner and outer shells. The inner shells duly compartmentalized for each control gears. The panel should have suitable size of Aluminium bus -bar three phase 4 wired system having current carrying capacity not less than 1.2 times the rated current carrying capacity of the incomer ACB/MCCB. The panel should have the following incoming and outgoing controls duly fixed with the panel by means of suitable link plates complete all as specified and as directed by Engr-in-Charge. (PCC platform of suitable size for mounting the feeder pillar box is deemed to be included in the quoted rate ), CPRI approved manufacturer and to accommodate the following incoming and outgoing controls and suitable size:-
INCOMING (i) MCCB 630 A 50 ka 4 pole -1 No. (ii) Digital Multi functional meter VAFPP (voltage, current,frequency, power factor-1 No. (iii) Phase indicator lamp (LED type) 1 set (set of three). OUT GOING (i) MCCB 160 A ,35 ka,4 pole -02 Nos. (ii) MCCB 100 A ,35 ka,4 pole -04 Nos.
Taking shutdown, dismantling of existing LT panel complete and S&F in replacement Indoor type cubical panel board suitable for 3 phase, 4 wired, 415V, 50 Hz and tested at CPRI for 35 MVA rapturing capacity at 415 volts factory fabricated in an approved factory with CRCA sheet of 2 mm thick having modern fabrication process powder coating in approved shade having thickness not less than 100 microns provided with suitable gasket to make it dust and vermin proof and general constructions conforming to IS : 8623/93. The LT Panel shall be front and back openable and having inner and outer shells. The inner shells duly compartmentalized for each control gears. The panel should have suitable size of Aluminium bus -bar three phase 4 wired system having current carrying capacity not less than 1.2 times the rated current carrying capacity of the incomer ACB/MCCB. The panel should have the following incoming and outgoing controls duly fixed with the panel by means of suitable link plates complete all as specified and as directed by Engr-in-Charge. (PCC platform of suitable size for mounting the feeder pillar box is deemed to be included in the quoted rate ), CPRI approved manufacturer and to accommodate the following incoming and outgoing controls and suitable size:-
INCOMING (i) MCCB 400 A 50 ka 4 pole -1 No. (ii) Digital Multi functional meter VAFPP (voltage, current,frequency, power factor-1 No. (iii) Phase indicator lamp (LED type) 1 set (set of three). OUT GOING (i) MCCB 160 A ,36 ka,4 pole -03 Nos.
Earthing complete with galvanised steel earth plate electrode 60×60cm.× 6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less' than 1.5 metres below normal ground level, connected to 32 x 6 mm galavanised iron strip by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 3 connected to earthing test point all as specified or indicated including testing on completion
M&L for earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required 32x6mm galavanised iron strip
M&L for fire alarm control panel complying with BS EN 54 4 Loop panel with 99 detectors & 99 modules and upto 200 detectors and modules (per each loop)
S&F for detctors Complying with and type certified to EN-45 addressable type multisensor detector with heat and smoke combination
Supply, laying of multi stranded copper conductor PVC insulated and unsheathed FRLSH cable 2 core 1.5 sqmm ISI marked complete all as specified and directed.
Supply, laying of multi stranded copper conductor PVC insulated and unsheathed FRLSH cable 4 core 1.5 sqmm ISI marked complete all as specified and directed.
S &F for addressable manual call point resettable type complete all as specified and directed.
S & F fire alarm sounders/Sirens Electronic type horizontal single stage continous normal operation for atleast 50 minutes with sound level 65 DB to 120DB measured at 1.5 mtr with sound output variation of +5DB1000m range
S&F addressable control moduledd complete all as specified and directed.
S&F remote response indjicators complete all as specified and directed.
Supply and fixing of signage shop glow in dark FIRE EXIT sign board with man running arrow symbol and stair of dimension 12" x 6" x8mm decorative transparent acralic, including fixing arragement all as specified and directed.
M&L for fixing of steel conduit of size 20 mm on wall/ceiling with clamps, screw and all connected items all as directed.
M&L for fixing of steel conduit of size 25 mm on wall/ceiling with clamps, screw and all connected items all as directed.
Supply and fixing Fire point on wall consjisting of - (a) Fire Extinguished, water stored pressure type (9 liters)-02 Nos (b) Fire Extingusher Dry chemical Powder, 5 Kg (ABC) Type-01 Nos (c) Fire Extingusher CO2, 5 Kg ( Light Wt squeeze grip) type -01 Nos
M/s Himgiri construction
Commercial Traders
R.K ENGINEERS & CONTRACTORS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .