| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹4.3 LAccepted-AOC CHHINDWARA MADHYA PRADESH | CHHINDWARA | CHHINDWARA | MADHYA PRADESH | 480553 | L-1 | Accepted-AOC Successful Bidder | |
| 2 | L-2₹4.5 L+₹11,752.22 (2.70%)Rejected-Finance NANDAN DAMUA CHHINDWARA M P 480555 | CHHINDWARA | CHHINDWARA | MADHYA PRADESH | 480555 | L-2 | Rejected-Finance Unsuccessful Bidder | |
| 3 | L-3₹4.8 L+₹44,800.26 (10.3%)Rejected-Finance AMBADA 14 POST AMBADA DISTRICT CHHINDWARA M P | AMBADA | CHHINDWARA | MADHYA PRADESH | L-3 | Rejected-Finance Unsuccessful Bidder |
Tender Value
₹6.9 L
EMD Value
₹8,700
Closing Date
16 Jan 2023, 11:00 amClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Staff Officer (Civil) KA
Office of the Area General Manager, Dungariya, Kanhan Area
Repair and Maintenance of 33 KV substation of Tandsi mines under Tandsi Sub Area
2023_WCL_266786_2
ka3450-civ-s-e056 of 2022-23
Open Tender
Civil Works - Others
Item Rate
45 days
33 KV Sub Station of Tandsi
-----N.A.------
4 documents required · 4 mandatory
₹8,700
9 Feb 2023
6 Jan 2023
17 Jan 2023
7 Jan 2023
16 Jan 2023
7 Jan 2023
7 Jan 2023 - 14 Jan 2023
Amount
Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge.
Dismantling old plaster or skirting raking out joints andcleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 metres lead.
12 mm plaster of mix: 1:6 (1 cement: 6 fine sand).
6 mm plaster of mix. 1:3 ( 1 cement : 3 fine sand).
Grading roof for water proofing treatment with cement concrete 1:2:4 (1 cement:2 coarse sand: 4 graded stone aggregate 20 mm nominal size).
Providing and laying APP (Atactic Polypropylene Polymer) modified prefabricated five layer, 3mm thick water proofing membrane, black finished reinforced with glass fibre matt consisting of a coat of bitumen primer for bitumen membrane @ 0.40 ltr/sqm. by the same membrane manufactured of density at 25°C, 0.87 - 0.89 kg/ltr and viscosity 70 -160 cps. Over the primer coat the layer of membrane shall be laid using butane torch and sealing all joints etc., and preparing the surface complete. The vital physical and chemical parameters of the membrane shall be as under : Joint strength in longitudinal and transverse direction at 23°C as 350/300 N/5cm. Tear strength in longitudinal and transverse direction as 60/80N. Softening point of membrane not less than 150°C.Cold flexibility shall be upto -2°C when tested in accordance with ASTM,D - 5147. The laying of membrane shall be got done through the authorised applicator of the manufacturer of membrane : 3 mm thick.
Providing and fixing in position collapsible steel shutters with vertical channels 20x10x2 mm and braced with flat iron diagonals 20x5 mm size, with top and bottom rail of Tiron 40x40x6 mm, with 40 mm dia steel pulleys, complete with bolts, nuts, locking arrangement, stoppers, handles, including applying a priming coat of approved steel primer.
Finishing walls with water proofing cement paint of required shade: New work (Two or more coats applied @ 3.84 kg/10 sqm).
Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gms/litre, of approved manufacturer, of required shade and colour complete, as per manufacturer's specification: Two or more coats on new work.
Painting with synthetic enamel paint of approved brand and manufacture to give an even shade: Two or more coats on new work.
Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface: Water thinnable cement primer.
Brick work with clay flyash F.P.S. (non modular) brick of class designation 3.5 in superstructure above plinth level up to floor five level in: Cement mortar 1:4 (1 cement : 4 coarse sand).
Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in - charge: Nominal concrete 1:3:6 or richer mix (i/c equivalent design mix).
Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation, levelling & dressing & finishing the top smooth.
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :1:3:6 (1 Cement : 3 coarse sand (zone-III) derived from natural sources: 6 graded stone aggregate 40 mm nominal size derived from natural sources).
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :1:2:4 (1 cement : 2 coarse sand (zone-III) derived from natural sources: 4 graded stone aggregate 20 mm nominal size derived from natural sources).
Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-in-charge: All kinds of soil.
Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing/paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-incharge. (Glazing, paneling and dash fasteners to be paid for separately) : For fixed portion Anodised aluminium (anodised transparent or dyed to required shade according to IS: 1868, Minimum anodic coating of grade AC 15).
Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge. (Cost of aluminium snap beading shall be paid in basic item): With float glass panes of 4.0 mm thickness (weight not less than 10kg/sqm).
Total impact of GST for the purpose of CTC
SAHEB CONSTRUCTION
Nasiruddin
stage.html
html • 0.04 MB
techsummary_276023.pdf
PDF • 0.18 MB
finsummary_276023.pdf
PDF • 0.18 MB
AL-56-2-22-23.pdf
PDF • 0.18 MB
finance_276023.pdf
PDF • 0.18 MB
BOQ Comparative Chart
xlsx • 0.01 MB
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .