Loading…
Loading…
Tender Value
₹1.1 Cr
EMD Value
₹2.1 L
Closing Date
2 May 2025, 11:30 amClosed
No
No
Single Packet System
Normal Tender
No
Not Applicable
Lowest to Highest
60 days
Expenditure
Capital (Works)
Above/Below/Par
TENDER
13 conditions · 2 needing a document upload
Average Annual Contractual turnover (A= V/N) received as per Annexure- I and as per clause 2.3.2 (A) (vi) of Tender Document.
Completion/Performance Certificate in support of 30%/40% / 60 % (as the case may be) for similar nature of work as per clause 2.3.2.A (v) of tender document.
1 condition
Please enter the percentage of local content in the material being offered. Please enter 0 for fully imported items, and 100 for fully indigenous items. The definition and calculation of local content shall be in accordance with the Make in India policy as incorporated in the tender conditions.
"Provision of Modification in EI of Medha at Rosa Jn. Station (Phase-III) i.c.w. Rosa - Sitapur doubling of Northern Railway".
178-SIG-CW-32-112-Pt-I
178-SIG-CW-32-112-Pt-I
Open
Works - General
6 Months
Unknown (Unspecified Location)
₹0
₹2.1 L
2 May 2025
9 Apr 2025
105 items across 1 schedule
| # | Description | Unit | Qty | Rate | Amount |
|---|---|---|---|---|---|
| — | — | — | 1,13,96,058.04 | ||
| — | 1.00 | — | — | ||
| Modification in EI System of Medha at Rosa Jn. Station of NR, as per RDSO spec. no. RDSO/SPN/192/2019. (i) Supply of necessary wiring material and installation accessories required for the El alteration work. (ii) Modification to the existing relay racks as per the approved SIP. (iii) Modification to the existing Application Logic circuits, Interface circuits, VDU, MT software and up- gradation of Data-logger database. (iv) Factory Acceptance Test & Site Acceptance Test for the approved Application Logic. (v) Installation and commissioning of El (vi) ASMADES (6 sets) | — | — | — | 94,55,000 | |
| — | 250.00 | — | — | ||
| Preparation of SWR Translation of SWR from English to Hindi. : Inspection by SSE/C/D&D | — | — | — | 5,415 | |
| — | 250.00 | — | — | ||
| Typing and Printing One master Copy SET in Hindi. Inspection by SSE/C/D&D | — | — | — | 5,907.5 | |
| — | 250.00 | — | — | ||
| Two Photocopies of Hindi Master Copy Set Inspection by SSE/C/D&D | — | — | — | 380 | |
| — | 4.00 | — | — | ||
| Spiral Binding of master of SWR & 02 set of photocopies as above including plastic cover. Inspection by SSE/C/D&D | — | — | — | 223.36 | |
| — | 20.00 | — | — | ||
| Fabrication, supply and fixing of scaffolding /cable carrier made of angle ironof Size 35mmX35mmX5mm and flat of size 25mmX3mm as per instructions of engineer at site.The space between two flats will b e 25cm or less as per site requirements allthe fixing materials i.e nut, bolt washer, insulators, cement concrete etc will be supplied by the contractyor . This includes insulating flat strips, cleaning priming by Red oxide, painting by ISI mark paint.Inspection :Site Engineer | — | — | — | 10,320.4 | |
| — | 80.00 | — | — | ||
| Supply of electric fuse complete with fuse block(base) for Railway signalling non- detoriorating type low voltage fuse assembly 2Amp/4Amp/16Amp. to suit . Specn. No.IRS: S-78/2006 and fuse block made of PBT/Polycarbonate as per IRS: S-75/2006 (Rev-2 & Amd 2 ) and drg no. 23748 (IRS) Alt.4 or latest. Fuse block shall be suitable for round head type fuses.Inspection : RDSO | — | — | — | 15,895.2 | |
| — | 1.00 | — | — | ||
| "Prep. of cable route plan, Cable core chart, Power supply arrangement plan for indoor and out door , Cable termination chart in relay room and location boxes, Location wiring plan, Cable insulation chart and register, Track circuit history card, Fuse analysis plan , Equipment disposition plan, Track circuit jumpering plan, Terminal and Contact analysis chart , Outdoor circuits,pull sheets,gomettie plans,diagrams. temp. plans required for execution of PNI/NI and other outdoor diagram and obtaining approval of the Engineer as per following :- (i) Supply of 6 copies of completion set of superior quality paper, laminated, properly bound in steel clip jaw file with cushioned cover.(ii) Software back up of complete set in the form of CDs. (iii) One complete set of tracings.(iv) Design through CAD(v) Drawings in A3 & plans in bigger size. (six sets). Inspection: SSE/C/D&D" | — | — | — | 46,706.56 | |
| — | 500.00 | — | — | ||
| Excavating and refilling of trench in Normal Soil to the level of ground with rammed earth as per approved Drg. No.NR/S&T/CON/1-1/97A. Aso as not to form a drain 0.3 Mtrs. Wide & 1 Mtr. Deep on both side of the station alongside the track. It shall conform to the safe distance as per signalling and cable plan. It also includes clearance of rooots of trees & bushes. Inspection: Site Engineer. | — | — | — | 40,440 | |
| — | 4000.00 | — | — | ||
| Supply and laying of 2nd class bricks in the trench and laying as per approved Drg. No.NR/S&T/CON/1-1/97A as per instructions of the site Engineer. Inspection: Site Engineer. | — | — | — | 34,200 | |
| — | 151.00 | — | — | ||
| Supply, laying & fixing of HDPE double Wall Corrugated (DWC) Duct as per as per RDSO Specification No. RDSO/SPN/204/2011 Ver. 1.1 With Amndt-1 (outer dia 120mm in 6m st. length with one coupler for every 6m length). All the materials cement, sand etc. are to be supplied by the contractor. This include brick work and other arrangements required to secure the pipe as per specifications, drawings and stipulations of tender documents and as per approved cable route plan including road crossing/platform/track crossing and for bridges and culverts etc. Inspection: Consignee. | — | — | — | 75,006.23 | |
| — | 64.00 | — | — | ||
| Supply and fixing of G.I. pipe perforated at a distance of 20 CM or less of required length at culverts/ bridges/along the cuttings, suitably concreted at both ends as per drg. No. (NR/S&T/CON/1. 4/97) or at ASM office / other buildings suitably fixing it to the wall and at both ends. G.I. clamps of M.S. flats bolts and nut, to be supplied by the contractor. G.I. pipe 75/80 mm dia, 3mm thick.Inspection: Consignee. | — | — | — | 59,136.64 | |
| — | 150.00 | — | — | ||
| All work of horizontal boring and trenchless cabling along with supply,transpotation and insertion of double wall corrugated pipe -( ISI marked ) conforming to RDSO Spec no. RDSO/SPN/204/2011, and the laying of cable in the boring under the track / road etc as per instruction of site engg. by using pipe of size 120 mm outer dia, 103.5 mm inner dia in which required number of cables to be crossed. The depth of horizontal boring should be minimum 1.0 m from rail flange/road level. Inspection : Consignee (for DWC pipe) | — | — | — | 3,27,907.5 | |
| — | 5000.00 | — | — | ||
| Laying of signalling/Telecom/power cables of different sizes as per approved Drg. No. NR/S&T/CON/1-1/97A and as per cable route plan approved by Railways and meggering of cable before and after its laying of all type of outdoor cables. Inspection: Site Engineer. | — | — | — | 46,000 | |
| — | 5.00 | — | — | ||
| Jointing of signalling cable straight through M-seal joint kit for U/G signalling cables, it includes supply and provision of jointing kit. Inspection: Site Engineer. | — | — | — | 10,660.3 | |
| — | 500.00 | — | — | ||
| Testing & meggering of all types of outdoor cables after its laying and termination on both ends under supervision of Railway representative. This also includes preparation of test report for core to core and core to earth on prescribed proforma for each core of the cable seperately. This also include dressing and lacing of cable on both ends. Proforma for testing and material for lacing to be supplied by the contractor. Inspection: Site Engineer. | — | — | — | 7,540 | |
| — | 5.00 | — | — | ||
| Casting, concreting and curing of foundation and erection of single app.cases of size (1160mmx760mm) at surface and 650mm deep as per approved Drg.No.NR/S&T/CON/2-7/97. A layer of 3 mm of bitumen compound has to be provided between foundation and location box to prevent ingress of water in the base of location box . All material such as cement,coarse sand,aggregate and anchor bolt shall be supplied by contractor . App. Case single will be supplied by Railway. Contractor is required to execute all type of repair Works of foundations if required during inserting the cable for termination. Inspection: Site Engineer. | — | — | — | 32,011 | |
| — | 5.00 | — | — | ||
| Supply of single app.case steel RE with 'E' type lock and key ward no.42 and handle as per drg. No. RE/S&T/ALD/SK/219/82 with (Alt A) and 221/82 with Alt.B. Inspection: Consignee. | — | — | — | 1,21,124.75 | |
| — | 1.00 | — | — | ||
| Preparation of App. Case single involving wiring of relays. Preparation & fixing of bakelite hylum sheet 910x800x6mm and backelite shelf 900x450x10mm duly fixed by angle iron piece of different size inside all the app. Cases. Hylum board shall be fixed on an angle iron frame of 25mmx25mmx3mm. Angle iron frame will be fixed in location boxes secured by nuts and bolts.This includes fixing of fuses, ARA terminal, Q series relays and other type relays on square bars fixing and jamming of cables with 2 inch thick salwood plank provided at the bottom. This will include opening, pasting and jamming armour of each cable in the hole drilled separately for each cable through the salwood plank and all cable entry points on location boxes, location huts, JBs relay room/battery room to be closed with suitable masonry Works covered with sand and plastering.Wiring description for terminal drawing of circuits, inside app. Case. Painting from out side as well inside with red oxide and aluminum paint is covered separately. Size of lettering will be 100mm or as per instructions of Engineer at site. All materials including Backelite shelf, hylum board, salwood plank, angle iron square bar, wire and wiring material as per the IRS specn., non deteriorating type HRC fuses with bases, catenary wires , nuts and bolts and other items shall be supplied by the contractor. Relays, ARA terminals only shall be supplied by the Railways. Inspection: Site Engineer. | — | — | — | 6,628.38 | |
| — | 2.00 | — | — | ||
| Preparation of App. Case single not involving wiring of relays. Preparation & fixing of bakelite hylum sheet 910x800x6mm and Backelite shelf 900x450x10mm duly fixed by angle iron piece of different size inside all the app. Cases. Hylum board shall be fixed on an angle iron frame of 25mmx25mmx3mm. Angle iron frame will be fixed in location boxes secured by nuts and bolts.This includes fixing of fuses, ARA terminal and fixing and jamming of cables with 2 inch thick salwood plank provided at the bottom. This will include opening, pasting and jamming armour of each cable in the hole drilled separately for each cable through the salwood plank and all cable entry points on location boxes, location huts, JBs relay room/battery room to be closed with suitable masonry Works covered with sand and plastering.Wiring description for terminal drawing of circuits, inside app. Case. Painting from out side as well inside with red oxide and aluminum paint is covered separately. Size of lettering will be 100mm or as per instructions of Engineer at site. All materials including Backelite shelf, hylum board, salwood plank, angle iron square bar, wire and wiring material as per the IRS specn., non deteriorating type HRC fuses with bases, catenary wires , nuts and bolts and other items shall be supplied by the contractor. ARA terminals only shall be supplied by the Railways. Inspection: Site Engineer. | — | — | — | 10,893.82 | |
| — | 2.00 | — | — | ||
| Preparation of App. Case to be used as battery box.(not requiring shelf and hylum of size 910x150x6mm only is reqd.). This includes fixing of fuses, ARA terminal and jamming of cables with 2 inch thick salwood plank provided at the bottom. This will include opening, pasting and jamming armour of each cable in the hole drilled separately for each cable through the salwood plank and all cable entry points on location boxes, location huts, JBs relay room/battery room to be closed with suitable masonry Works covered with sand and plastering.Wiring description for terminal drawing of circuits, inside app. Case. Painting from out side as well inside with red oxide and aluminum paint is covered separately. Size of lettering will be 100mm or as per instructions of Engineer at site. All materials including hylum board, salwood plank, wire and wiring material as per the IRS specn., catenary wires, nuts and bolts and other items shall be supplied by the contractor. ARA terminals only shall be supplied by the Railways. Inspection: Site Engineer. | — | — | — | 6,550.48 | |
| — | 3.00 | — | — | ||
| Casting, concreting and curing of foundation and erection of half app.cases of size (670mmx760mm) and 650mm deep as per Drg.No.NR/S&T/CON/2. 8/97. A layer of 3 mm of bitumen compound has to be provided between foundation and location box to prevent ingress of water in the base of location box . All material such as cement,coarse sand,aggregate and anchor bolt shall be supplied by contractor . App. Case half will be supplied by Railway. Contractor is required to execute all type of repair Works of foundations if required during inserting the cable for termination. Inspection: Site Engineer. | — | — | — | 16,869.96 | |
| — | 3.00 | — | — | ||
| Supply of apparatus case steel RE half with E type lock and key ward no.42 and handle as per drg.no. RE/S&T/ALD/SK/220/82 and 221/82 with Alt.B. Inspection: Consignee. | — | — | — | 56,300.4 | |
| — | 3.00 | — | — | ||
| Preparation of App. Case half not involving wiring of relays. Preparation and fixing of Bakelite hylum sheet 450x800x6mm and Backelite shelf 450x450x10mm duly fixed by angle iron piece of different size inside all the app. Cases. Hylum board shall be fixed on an angle iron frame of 25mmx25mmx3mm. Angle iron frame will be fixed in location box secured by nuts and bolts. This includes fixing of fuse ARA terminal and fixing and jamming of cable with 2 inch thick salwood plank provided at the bottom. This will include opening, pasting and jamming armour of each cable in the hole drilled separately for each cable through the salwood plank and all cable entry points on location boxes, location huts, JBs relay room/battery room to be closed with suitable masonry Works covered with sand and plastering.Wiring description for terminal drawing of circuits, inside app. Case. Painting from out side as well inside with red oxide and aluminum paint is covered separately. Size of lettering will be 100mm or as per instructions of Engineer at site. All materials including Backelite shelf, hylum board, salwood plank, angle iron square bar, wire and wiring material as per the IRS specification, non deteriorating type HRC fuses with bases, catenary wires, nuts and bolts and other items shall be supplied by the contractor. Relays, ARA terminals only shall be supplied by the Railways. Inspection: Site Engineer. | — | — | — | 11,215.89 | |
| — | 500.00 | — | — | ||
| Supply of ARA Terminal Block 25MM center M6 terminal made of PBT as per IRS spec. No.IRS-S-75/2006 (Rev.2) & IRS drawing No. SA-23741A(Alt.4), SA23745(Alt.5) ,SA-23746 & SA- 23756(Alt.3) .Inspection: RDSO | — | — | — | 38,565 | |
| — | 4.00 | — | — | ||
| "Fixing, wiring, testing & adjustment of point machines as per standard practice. It also includes :- i) Fixing of switch extension 'P' bracket, providing insulation for switch extension bracket, fixing ground connections, adjusting the correct opening of switches and adjusting the point machine with crank handle. ii) Wiring inside the point machine, erection & wiring of JB with lock & key as per drawing, provided with terminal strips. iii) Supply & fixing of GI pipes with flange for taking cable in to point machine and jn. Box through gland/GI pipe. iv) Complete material for installation viz. point insulation material, Jn. box, GI pipe, gland pipe, wiring material, nut & bolts of various sizes, angle iron of size 75mmx75mmx10mm, channels for fixing the machine, lugs for point rodding and insulation materials for stretcher bar 90R/52kg/60kg as per . drg.no.SA-23172 (adv.) Alt.1 will be supplied by the contractor. v) Smithy and fitting work required at site for complete installation of Gauge tie plate and insulation of GTP as per approved Drg.no.NR/S&T/CON/7-6/97 and william stretcher bar (if reqd.) will be done by the contractor. Machine shall be overhauled by contractor if required. vi) This includes removal of existing gears and fixing the machine at raised level on channel as per standard practice to avoid flooding wherever required. vii) Supply of ground connections of electric point machine, non insulated GTP & CTP extension plate,Jn. box and stretcher bar shall be made available by the Rlys. in which the supply of ground connections, Jn box is covered separately. Inspection: Site Engineer " | — | — | — | 37,483.2 | |
| — | 4.00 | — | — | ||
| Supply and fixing of Spigot for point machines. (Job = Per Pt.M/c) . Inspection : Consignee | — | — | — | 1,003.4 | |
| — | 4.00 | — | — | ||
| Fabrication & Supply of complete set of point rodding for point machines of IRS type or its equivalent type as per . drg. No. SA 8800-01 (Adv) or latest along with 'P' brackets and 'L' bracket required (coal Bengal for smithy work, all type of nuts & bolts and Lugs as reqd also to be supplied by contractor with each set) , Inspection: Consignee. | — | — | — | 38,046.12 | |
| — | 4.00 | — | — | ||
| Supply of Insulation for 'L' type bracket for point fitting IRS type complete consisting of Insulation plate - 01 No. Ferrule - 02 Nos. Washers - 04Nos. (Material Nylon 66). Inspection : CONSIGNEE | — | — | — | 1,199.8 | |
| — | 8.00 | — | — | ||
| Supply of Insulation for 'P' bracket for point fitting IRS type complete consisting of Insulation plate - 01 No. Ferrule - 02 Nos. Washers - 04Nos. (Material Nylon 66). Inspection : CONSIGNEE | — | — | — | 6,013.6 | |
| — | 2.00 | — | — | ||
| Supply, installation and wiring complete KLCR and its box in location boxes, supply, installation, wiring of heavy duty push button, LED indicator on MS sheet as per N.R. practice for crank handle locking. This work includes fixing & wiring of magneto telephones as per instructions of the site Engr. This includes all materials such as heavy duty push button, LED indicator (10mm), MS sheet of 4.5mm thick, nuts and bolts, fixing materials for the magneto telephone, and wiring materials to be supplied by contractor Inspection : RDSO(for relay). | — | — | — | 38,671.38 | |
| — | 3.00 | — | — | ||
| Installation of Berthing and straight DC track circuits to suit RE area as per std. Practice. This will include following as per site requirement :- (a) Drilling of holes 7.2 mm dia or size as required provision of continuous G.I. wire bonding on switch portion and crossing of point with two bonds wires and two clips duly fastended with fish plates and bolts at each joints including transverse bonding with rope wire. 8 SWG G.I. soft bond wire, Channel bond pins and all other material required will be supplied by contractor. (b) Jumpering from rail to rail or to track lead junction box including polarity jumpers/cables as per track jumpering/ insulation diagram. This includes continuity of joint on rail web for TLJB/BOOTLEG bonding method, terminating the jumpers in the TL JB and fixing the jumper on the sleeper as per instructions of Engr. at site. (c) Fixing of insulated block joints complete with provision of skimmed fish plate. Fish plates shall be supplied by the Railways but skimming to be done by contractor. Supply of insulation materials for insulated block joints is not included.(d) Fixing of TL JBs as per drg. No.(NR/S&T/CON/3.2/97A) along with concrete foundation and plastering on both ends i.e. T.F. and TR end and for polarity changers as per the track jumpering/ insulation diagram. All material for fixing including angle iron shall be supplied by the contractor. This also includes supply and fixing of TLJBs will provision of M-6 terminals. TLJB to be written with track circuit number. (e) Prov. and wiring in the app. Cases/relay huts of T.F. battery charger, TF resistance 15 Ohms, track relays, choke B type (at Feed End & Relay End) & batteries as per the standard practice using fuses and terminals. This all include supply of all material by contractor except supply of TF battery charger, batteries, relays which are covered separately.(f) Commissioning of track circuits as per prov.of para of IRS specn. S-36/87 Amd 2. This includes adjustment of track feed resistance, testing with train shunt resistance. This also includes preparation of track history cards. Track history card should be supplied by the contractor.Inspection : Site Engineer Note: Inspection RDSO for Supply items (i) CHOKE (ii) Fuses (iii) Resistance. | — | — | — | 45,367.74 | |
| — | 6.00 | — | — | ||
| Installation of Point track circuit having single point (excluding traps) DC track circuits to suit RE area as per std. Practice. This will include following as per site requirement:- (a) Drilling of holes 7.2 mm dia or size as required provision of continuous G.I. wire bonding on switch portion and crossing of point with two bonds wires and two clips duly fastended with fish plates and bolts at each joints including transverse bonding with rope wire. 8 SWG G.I. soft bond wire, Channel bond pins and all other material required will be supplied by contractor. (b) Jumpering from rail to rail or to track lead junction box including polarity jumpers/cables as per track jumpering/ insulation diagram. This includes continuity of joint on rail web for TLJB/BOOTLEG bonding method, terminating the jumpers in the TL JB and fixing the jumper on the sleeper as per instructions of Engr. at site. (c) Fixing of insulated block joints complete with provision of skimmed fish plate. Fish plates shall be supplied by the Railways but skimming to be done by contractor. Supply of insulation materials for insulated block joints is not included.(d) Fixing of TL JBs as per drg. No.(NR/S&T/CON/3.2/97A) along with concrete foundation and plastering on both ends i.e. T.F. and TR end and for polarity changers as per the track jumpering/ insulation diagram. All material for fixing including angle iron shall be supplied by the contractor. This also includes supply and fixing of TL JBs will provision of M-6 terminals. TLJB to be written with track circuit number. (e) Prov. and wiring in the app. Cases/relay huts of T.F. battery charger, TF resistance 15 Ohms, track relays, choke B type (at Feed End & Relay End) & batteries as per the standard practice using fuses and terminals. This all include supply of all material by contractor except supply of TF battery charger, batteries, relays which are covered separately.(f) Commissioning of track circuits as per prov.of para of IRS specn. S-36/87 Amd 2. This includes adjustment of track feed resistance, testing with train shunt resistance. This also includes preparation of track history cards. Track history card should be supplied by the contractor. (.:.)Inspection : Site Engineer Note: Inspection RDSO for Supply items (i) CHOKE (ii) Fuses (iii) Resistance. | — | — | — | 1,45,033.74 | |
| — | 10.00 | — | — | ||
| QBCA1 Relay. Inspection : RDSO | — | — | — | 42,356.6 | |
| — | 9.00 | — | — | ||
| Supply of QSPA1 relays AC immunised plug in type 24V DC slow to pick up neutral line relay miniature tractive armature with 8F/4B contacts as per BRS : 939A or latest amendments if any, BRS :966-F2, IRS-S-34 & IRS-S-23 (as aplicable ) or latest . Inspection : RDSO | — | — | — | 55,873.71 | |
| — | 9.00 | — | — | ||
| Supply of QTA2 relays AC immunised plug in type DC 9 Ohm neutral track relay miniature tractive armature with 2F/1B contacts as per BRS : 939A or latest amendments if any, BRS :966 Append F2, IRS-S-34 & IRS-S-23 & IRS-S-60 (as applicable). Inspection : RDSO | — | — | — | 50,787.09 | |
| — | 9.00 | — | — | ||
| Supply of track feed batt. charger 110VAC/2-4-6 VDC / 10 Amps as per RDSO spec. no. IRS: 89/2013 (Amd 1) or latest from RDSO appd. Firm. Inspection: RDSO. | — | — | — | 39,371.58 | |
| — | 27.00 | — | — | ||
| Supply of sec. cell low maintenance 2 V/ 80 AH. conforming to IRS S-88/2004 Rev-1or latest with micro porous vent plugs cum floats with inter cell connectors, nuts,bolts,washers etc. Inspection: RDSO | — | — | — | 94,805.91 | |
| — | 4.00 | — | — | ||
| Supply of Relay AC immune ,plug in type,style QBAT, DC biased track, 9 ohms 24 V DC 2F/2B contacts, front & back contacts metal to carbon with plug board retaining clip conforming to RDSO/SPN/84, Ver 2.0 Alongwith IRS:S-23, S-34 & IRS:S-60 (as applicable). The interlocking code for this unit shall be ABEJX. Inspection : RDSO | — | — | — | 24,800.16 | |
| — | 4.00 | — | — | ||
| Supply of Hydrometer Exide make for measuring specific gravity of battery, graded acid with mounting stand in location boxes. Inspection : Consignee | — | — | — | 1,147.76 | |
| — | 27.00 | — | — | ||
| Charging of lead acid secondary cells of 80 AH capacity as per standard charging procedure (with contractor charging equipments ). All charging materials ie. Sulphuric acid conforming to latest IRS specs and distilled water as per IRS specs will be supplied by contractor. This also includes installation of secondary batteries, their interconnection and writing work. Inspection : Site Engineer | — | — | — | 6,523.47 | |
| — | 6.00 | — | — | ||
| Supply and installation of earth electrodes as per std. practice. The item includes digging of pit in earth, 3 Mtrs. deep and fixing earth electrode pipe. Casting of cement concrete enclosures as per drg. No. (NR/S&T/CON/6.4/97). The soil treatement shall be done as per std. pratice. The item includes provn. of mild steel flat of size 35mm x 6mm (as per IRSEM) and nut bolted connection of MS flat with earth electrode. The other end of mild steel flat to be connected to block instrument, cable sheath of power equipment, signal base, apparatus case, CT rack / relay racks, other equipments as per the instruction of Engr. at site & IRSEM. Earhting connection location to location shall be done through cable which shall be provided by Railway. Complete materials such as earth electrodes as per drg. No. ( NR/S&T/CON/6. 3/97), cement, wiring material, nut bolt for connection & mild steel flat of size 35mm x 6mm or 210 sqm as per SEM etc. to be supplied by the contractor. Inspection : Consignee | — | — | — | 21,841.56 | |
| — | 10.00 | — | — | ||
| Earth work for excavation and refilling around location boxes, signals etc. where necessary including 50m lead and 1.5m lift by excavation. The earth shall be rammed including breaking of clods, levelling and dressing. The earth work around the location/junction boxes/signalls shall be up to the plaster level and for width sufficient for the maintainer to attend the box both from front & back side. Inspection : Site Engineer | — | — | — | 1,459.7 | |
| — | 10.00 | — | — | ||
| General concrete work in cement, coarse sand and aggregate ratio 1:3:6, work scattered at different places for items not covered in above schedule and fine plastering of top will be done with cement sand ratio of 1:4 . Volume of foundation also includes volume of C.I. base, anchor bolts etc. Coarse sand, aggregate 25mm and cement to be supplied by contractor. Inspection : Site Engineer | — | — | — | 34,271.7 | |
| — | 10.00 | — | — | ||
| Brick work with well burnt bricks in foundations and plinths with cement and sand (ordinary) mixture of 1:4 ratio. All material is to be supplied by the contractor. Inspection : Site Engineer | — | — | — | 34,810.3 | |
| — | 1.00 | — | — | ||
| "Cleaning , Scrapping , Painting and lettering of all newly installed and existing gears such as signals, point equipment, track circuit equipment with T.C. no on rail app. Cases JB. TL JBs point rodding cranks, compensators etc. including gate equipment if existing in station section as per the provision of IRSEM. All paints (ISI marked) shall be approved by Railway Engr. and painting material to be supplied by the contractor. This item also includes writing and painting requirement of all indoor and outdoor gears along with making of all circuit nos. near terminal and terminal boards/track in app. Cases, junction boxes, relay room, SMs room, writing of relay nomenclature fuse nos. and equipment nomenclature as the approved plans and as per provision of IRSEM. (1 Job=1 Station). Inspection : Site Engineer" | — | — | — | 24,709 | |
| — | 6.00 | — | — | ||
| Hiring and opertating multi utility vehicle (Maximum 3 vehicle in a month of loading capacity one MT with sitting capacity of 4 to 6 persons, 4 stroke, 4 cylinder engine, factory built metal body, cargo box type passenger cabin type or both (with 24 hrs availability) including cost of fuel, lubricants, operating and maintenance including on kutcha / pucca road along the track. The contractor shall arrange road permit for vehicle for all the states of operation as per instructions of engineer incharge. Vehicle shall not be older than 3 years. The max km utilization per month is 1200KM per vehicle | — | — | — | 1,82,655.12 | |
| — | 600.00 | — | — | ||
| Extra over above item no. for every additional KM or part there of over 1200 KM per month. (Unit Vehicle-Kilometer = Number) | — | — | — | 12,936 | |
| — | 1.00 | — | — | ||
| "Fixing of CLS surface base, bolting on the foundation. Erection of CLS post with signal unit on the top or on an off-set bracket and fitting ladder and guard to the post at the top. Concreting ladder base and embedded into the ground with supporting bracket in the middle, blanking of the ladder for a distance of 1 feet between the height 6' 9" and 7' 9" from the rail level by MS angle and MS sheet 6mm thick wherever required. This includes provision of wooden (SAL) cross arm 1 mtr x 1 mtr for CLS unit prior to the commissioning, fixing of LED aspect, current regulator and hoods of CLS unit, terminating cables, wiring the CLS unit and focusing the signal. Elevation & distance of foundation from track shall be in accordance with schedule of dimension for Indian Railways and as per NR practice. All items for the above Works except Signal unit, LED signal, Signal post, Base and Ladder shall be supplied by the contractor including but not limited to the following: i) "U" bolt for offset brackets, ii) Wooden cross arm 1 mtr. x 1 mtr., iii) MS angle and MS sheet for blanking of ladder, iv) Supply and fixing of signal number plate (retro reflective) with complete fittings as per standerd railway practice. v) Wire mesh guard, lock for unit if required, nuts, bolts etc for the following: (a) Installation, erection, wiring of 3/4 aspect color light signal. N Inspection: Site Engineer. " | — | — | — | 4,160.31 | |
| — | 1.00 | — | — | ||
| Installation, erection and wirng of 2/3/4 aspect LED lit colour light signal including 1/2/3/4/5/6 way Jn. type/Stencil/Theatre type route indicator which also includes fixing of route indicator on the top of the signal post or on offset bracket including fixing of offset bracket, wiring the whole unit, focussing of signal & route indicators. All items for installation and erection ( excluding unit junction type route indicator and offset bracket covered separately) to be supplied by the contractor. Wiring & other fixing material, 'U' bolts will also be supplied by the contractor.Inspection: Site Engineer | — | — | — | 4,482.58 | |
| — | 1.00 | — | — | ||
| Casting, concreting and curing of foundations for shunt signal/ 'F' marker of size (855mmx855mm) at bottom and (711mmx711mm) at top and 750mm deep as per approved Drg. no. NR/S&T/CON/2-1/97A. All material such as cement, coarse sand, aggregate & foundation bolts will be supplied by contractor. Inspection: Site Engineer | — | — | — | 4,062.42 | |
| — | 1.00 | — | — | ||
| Installation, erection and wiring of independent position light shunt signal/'F' marker.This includes fixing of shunt signal, surface base signal post,LED signal unit/ lenses, lamp hood and wiring of shunt unit and focussing the signal. All material such as wire,nut& bolt etc. will be supplied by the contractor. Inspection: Site Engineer | — | — | — | 1,285.72 |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
HTML
nit.pdf
NIT
TD-112-Pt-I.pdf
ATTACHMENT
rosaappdSIP1_c_1.pdf
ATTACHMENT
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .