Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹91,350Accepted-Finance | L1 | Accepted-Finance Price bid approved | |
| 2 | L2₹99,600+₹8,250 (9.03%)Accepted-Finance | L2 | Accepted-Finance Price bid approved |
| Sl No | Description | Qty | Unit | DURAI ENGINEERING WORKS L2 | RAYAN AND COMPANY L1 |
|---|---|---|---|---|---|
| 1.00 | Cleaning of Converter cubicles, Field Breaker cubicles,and Regulation Cubicle,checking the tightness of AC/DC bus bar joints,terminal blocks in Converter panels,Field Breaker panel and Regulation panel. | 1 | No | 10,000 ₹11,800 | 9,500 ₹11,210 Lowest |
| 2.00 | Opening/closing time and contact resistance measurement works of Field breaker main and FDR contacts, testing of relays, transformers & timers carrying out the modification works for conducting the dummy load test in the Digital Excitation System and measurement of Rotor DC resistance and impedance measurement at stand still, barring gear speed and various speed and various speeds during rolling of turbine. | 1 | No | 8,500 ₹10,030 | 8,100 ₹9,558 Lowest |
| 3.00 | Charges for transporting the testing equipment,Cleaning & assisting for conducting the tests on Generator Relay Panel testing. | 1 | No | 8,300 ₹9,794 | 8,000 ₹9,440 Lowest |
| 4.00 | Charges for transporting the testing equipments,cleaning & assisting for conducting the tests on HT relay panel. | 13 | Nos | 15,600 ₹18,408 | 13,000 ₹15,340 Lowest |
| 5.00 | Cleaning,Tightness checking, defect replacing and Testing assistance for calibration of panel meters and transducers at UCB. | 9 | Nos | 15,300 ₹18,054 | 13,500 ₹15,930 Lowest |
| 6.00 | Assistance for releasing, servicing and refixing of air filter with regulator in all pneumatic valves. | 3 | Nos | 1,500 ₹1,770 | 1,350 ₹1,593 Lowest |
| 7.00 | Rectification of MSSV actuators control circuit by fixing/removing DC contactors,fabrication and cripping of DC leads for compound motors with DC contactors, power and control wiring setting of limit/torque setting,terminal block tightness/cleaning as instructed by our maintenance engineer. | 1 | No | 22,500 ₹26,550 | 22,000 ₹25,960 Lowest |
| 8.00 | Cleaning,tightness checking and assisting for servicing of all Contractors & other components of the control panel | 12 | Nos | 6,000 ₹7,080 | 5,400 ₹6,372 Lowest |
| 9.00 | Checking the control circuit of Instrument Air /Service Air Compressor/Driers and debris filter modules for the healthiness.Terminal block tightness,Identifing and replacing the defective components, removing and reconnecting the control cables as instructed by our maintenance engineer. | 7 | Nos | 11,900 ₹14,042 | 10,500 ₹12,390 Lowest |
Tender Value
Refer Docs
EMD Value
₹1,000
Closing Date
8 Oct 2026, 2:00 pmClosed
CE/TTPS
Chief Engineer Tuticorin Thermal Power Station-Tuticorin
TTPS ES Circle MRT I Unit III Annual Overhauling works of digital Excitation System GRP 6 6KV System and LT system for the year 2026 27
2026_EB_707560_1
CE/SE/ES/TTPS/No.81/2026-27
Open Tender
Electrical and Maintenance Works
Item Rate
25 days
TTPS
As per BQR conditions in NIT
6 documents required · 6 mandatory
₹0
₹1,000
Yes
12 Oct 2026
24 Sept 2026
9 Oct 2026
24 Sept 2026
8 Oct 2026
24 Sept 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Cleaning of Converter cubicles, Field Breaker cubicles,and Regulation Cubicle,checking the tightness of AC/DC bus bar joints,terminal blocks in Converter panels,Field Breaker panel and Regulation panel. | 1 | No | 55 | ₹55 |
| 2 | Opening/closing time and contact resistance measurement works of Field breaker main and FDR contacts, testing of relays, transformers & timers carrying out the modification works for conducting the dummy load test in the Digital Excitation System and measurement of Rotor DC resistance and impedance measurement at stand still, barring gear speed and various speed and various speeds during rolling of turbine. | 1 | No | 65 | ₹65 |
| 3 | Charges for transporting the testing equipment,Cleaning & assisting for conducting the tests on Generator Relay Panel testing. | 1 | No | 65 | ₹65 |
| 4 | Charges for transporting the testing equipments,cleaning & assisting for conducting the tests on HT relay panel. | 13 | Nos | 65 | ₹845 |
| 5 | Cleaning,Tightness checking, defect replacing and Testing assistance for calibration of panel meters and transducers at UCB. | 9 | Nos | 65 | ₹585 |
| 6 | Assistance for releasing, servicing and refixing of air filter with regulator in all pneumatic valves. | 3 | Nos | 65 | ₹195 |
| 7 | Rectification of MSSV actuators control circuit by fixing/removing DC contactors,fabrication and cripping of DC leads for compound motors with DC contactors, power and control wiring setting of limit/torque setting,terminal block tightness/cleaning as instructed by our maintenance engineer. | 1 | No | 65 | ₹65 |
| 8 | Cleaning,tightness checking and assisting for servicing of all Contractors & other components of the control panel | 12 | Nos | 65 | ₹780 |
| 9 | Checking the control circuit of Instrument Air /Service Air Compressor/Driers and debris filter modules for the healthiness.Terminal block tightness,Identifing and replacing the defective components, removing and reconnecting the control cables as instructed by our maintenance engineer. | 7 | Nos | 65 | ₹455 |
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.25 MB
BOQ_850354.xls
BOQ • 0.29 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .