| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹30.3 LAccepted-AOC | L1 | Accepted-AOC L1 | |
| 2 | L2₹34.4 L+₹3.1 L (9.95%)Rejected-Finance | L2 | Rejected-Finance OTHER THAN LOWEST BIDDER | |
| 3 | L3₹35.3 L+₹4.0 L (12.7%)Rejected-Finance | L3 | Rejected-Finance OTHER THAN LOWEST BIDDER | |
| 4 | L4₹36.0 L+₹4.7 L (15.0%)Rejected-Finance | L4 | Rejected-Finance OTHER THAN LOWEST BIDDER | |
| 5 | L5₹36.6 L+₹5.3 L (17.0%)Rejected-Finance | L5 | Rejected-Finance OTHER THAN LOWEST BIDDER |
Tender Value
₹42 L
EMD Value
₹84,000
Closing Date
6 Oct 2022, 6:00 pmClosed
GE 881 EWS C/o 56 APO
GE 881 EWS C/o 56 APO
REPAIR TO HARD STANDING, BOUNDARY WALL AND OTHER MISC WORKS AT BG, HAMIRPUR AND JWG AND REPAIR/ MAINT OF LT OVERHEAD CONDUCTOR, UNDERGROUND CABLE, LT PANEL AND ALLIED ACCESSORIES IN THE AOR OF AGE B/R-I UNDER GE 881 EWS
2022_MES_550745_1
GE/PNH-45/2022-23
Open Tender
Civil Works
Item Rate
180 days
GE 881 EWS C/o 56 APO
AS PER TENDER DOCUMENTS
8 documents required · 8 mandatory
₹500
GE 881 EWS
₹84,000
Yes
20 Oct 2022
8 Sept 2022
13 Oct 2022
8 Sept 2022
6 Oct 2022
23 Sept 2022
Amount
B&R PORTION:- Demolition of cement concrete (un-reinforced) in ground floors and paving not exceeding 15cm thickness (below or above ground level), complete all as specified and directed.
M&L for 100mm thick plain cement concrete 1:4:8 type D-2 (using 40mm graded crushed stone aggregate) as in sub base floor, complete all as specified and directed.
M&L for Machine pressed precast concrete interlocking paver block any shape and size confirming to IS-15658-2006 of 80mm thickness M-40 Grade,laid jointed pointed with grey cement and no pigments, with & including 25mm thick sand filling under pavers and paking the joints of paver block with sand, including watering and consolidation complete all as specified and directed by Engr-in-Charge.
M&L for Machine pressed precast concrete interlocking paver block any shape and size confirming to IS-15658-2006 of 60mm thickness M-35 Grade,laid jointed pointed with grey cement and no pigments, with & including 25mm thick sand filling under pavers and paking the joints of paver block with sand, including watering and consolidation complete all as specified and directed by Engr-in-Charge.
M&L for cement concrete (1:2:4) using 20mm graded stone aggregate as in lintels upto 1.5 metre clear span, cills, steps, siesmic and other similar bands, plinth courses, string courses, lacing courses, parapets and railing upto 60cm height, copings, bed block, kneelers, apex stones, bed plates, roof kerbs round or chamfered on edges, water troughs and the like including weathering, slightly rounded or chamfered angles and throatings etc.including necessary form work complete all as specified and directed by Engineer-in-Charge.
M&L for 75mm thick plain cement concrete 1:4:8 type D-2 (using 40mm graded crushed stone aggregate) as in sub base floor, complete all as specified and directed.
M&L for 300x300mmx25mm thick chequered cement concrete tiles set and jointed in neat cement slurry and pointed in white or coloured cement mixed with mixture of pigments to match with the colour of tiles laid over and including 20mm thick screed bed in CM (1:6), including demolition of existing floor tiles complete all as specified and as directed.
M&L for 100 mm thick PCC 1:2:4 type B-2 (using 40 mm graded crushed stone aggregate) as in flooring and finishing fair, even and smooth without using extra cement, complete all as specified and directed.
M&L for Plain cement concrete 1:3:6 type C-1(using 20mm graded crushed stone aggregate) as in surface channels and drains, complete all as specified and directed.
Demolition of cement concrete (reinforced) of any description and in any position not otherwise specifically described complete all as specified and directed by Engineer-in-Charge.
M&L for Precast PCC 1:2:4 type B1 (20mm graded crushed stone aggregate) as in landings, cover slab for manholes/drain etc set in cement mortar(1:6), including necessary formwork complete all as specified and directed.
Form work to sides and sofifits of floor or roof beams, beam haunching, girders, bressummers, lintels etc for rough finished surfaces of concrete, complete all as specified and directed.
Extra for forming fair finished drain or channel 30cm inner girth in cement concrete using extra cement including forms, moulds, mitred/stopper ends etc complete all as specified and directed.
Demolition of brick or stone masonry, built in cement mortar including all quoins, arches, pillars etc but excluding ashlars facings, dressed stone work, complete all as specified and directed.
M&L for walling of random rubble stone/boulder masonry brought upto course, well bonded, bedded and solidly hearted, built in cement mortar (1:6), complete all as specified and directed.
All as per Srl item No. 15 above but except stone complete all as specified and directed.
M&L for Plain cement concrete 1:5:10 type E-2 (using 40mm graded crushed stone aggregate) as in foundations filling and mass concrete, complete all as specified and directed.
M&L for Precast PCC 1:3:6 Type C-1 (using 20mm graded crushed stone aggregates) as in bond stone, bed plate, strings coarse etc and set in CM (1:6), complete all as specified and directed.
Extra over stone walling for hammer dressing with maximum depression on face from straight edge held against the dressed surface not exceeding 40mm to face stones (lime and sand stone) and dressing of face beds and joints, complete all as specified and directed.
M&L for Raised pointing to random rubble masonary, or polygonal rubble, uncoarsed or brought upto courses in cement mortar 1:4, complete all as specified and directed.
M&L for Boulder filling hand packed tightly (any thickness) at back of walls over arches etc. and raising (or lowering) to the required level, complete all as specified and directed.
S&F in repair PVC (SWR) pipes 110mm dia any length single socketed with rubber ring joint laid in trenches/floors or as in weep holes as soil pipe(vent pipe) complete all as specified and directed.
M&L for Brick work with sub class ‘B’ bricks straight or curved on plan exc 6m mean radius, built in cement mortar (1:4), complete all as specified and directed.
M&L for Precast cement concrete hollow block masonry built in PCC 1:2:4 type B-I (using 20mm graded crushed stone aggregate) exc. 10 cm in width and setting in mortar 1:4, complete all as specified and directed.
Taking down cement plaster of any description on stone or brick walls etc including racking out joints, hacking for key scrubbing down with water etc. complete all as specified and directed.
M&L for rendering 15 mm thick on other than fair faces of brick or stone masonry wall surfaces in cement mortar 1:4 and finished the surface even and smooth without using extra cement, complete all as specified and directed.
M&L for preparation of newly plastered / unplastered surfaces of wall including cornices pilaster etc, and applying two coats of cement base paint complete all as specified and directed.
S&F in repair Galvanised, 2 strand steel barbed wire 2.24mm dia, barbed with 2mm dia barbs at 75mm spacing and straining and fixing to any type of standard rails straining bolts, including securing and tying at crossings with and provision of galvanized (zinc coating 60 gram) mild steel wire, staple or steel pins, etc complete all as specified and directed.
Dismantling wrought iron or mild steel work of any description complete all as specified and directed.
Excavation in post holes each not exceeding 0.5 cum getting out in any type of soil, returning, filling in, including spreading, leveling, watering and well ramming earth or broken rubble mixed with earth around in layers not exceeding 25cm, watering, and removing surplus soil to a distance n exc 50m and making good surface, complete all as specified and directed.
S&F Mild steel work as in posts and struts in fencing including cuttings, tops to shapes, as directed, drilling, holes, notching for wire etc. flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting etc. fixed and similar work conforming to Fe-290 Gde E-165 complete all as specified and directed.
S&F Mild steel screw bolts dia not exceeing 15mm at neck, machine made, with hexagonal or square heads at one end and screwed the other, or screwed both ends; each screwed and to be fitted with washers and one hexagonal or square nut, length of bolt 5cm to 10cm long, complete all as specified and directed.
Dismantling fencing wire mesh, any type complete all as specified and directed.
Fixing only chain link fencing including line wires, any mesh, size and type to any type of standards, rails, straining bolts, etc. including provission of binding wire, complete all as specified and directed.
Supply only chain link MS galvanisd (zinc coating 60gram) fencing, any size or type, complete all as specified and directed. Note:-Type / size of fencing holes / dia of chain link fenching shall be as approved by GE. The weight of chain link fencing shall be calculated for payment as per actual weight or standard weight as per SSR which ever is less.
S&F Mild steel work conforming to Fe-290 (Gde E-165) as in grills, gratings etc. with ends of bars shouldered and/ or rivetted or forged into spikes; framed guard bars, and similar works, complete all as specified and directed.
M&L for two coats of synthetic enamel painting on new steel surfaces over 10cms width or girth over a coat of red oxide primer etc all as specified and directed.
S&F mild steel TMT bars 10 mm dia and over, cut to length, bent to shape requrired, including cranking, bending spirally for columns hooking for columns hooking ends and binding with and including mild steel wire(annealed) not less than 0.9 mm dia or securing with clips complete all as specified and directed.
E&M PORTION:- Excavation in trenches n. exc. 1.5 mtr in wide and n. exc. 1.5 mtr in depth for laying of underground cable and getting out in Hard/dense soil complete all as specified and directed.
Excavation in trenches not exc. 1.5 m wide and exc. 1.5m but not exc 3.0 m in depth for foundation of poles, stay assembly etc and getting out in hard/ dense soil complete all as specified and directed.
Returning, filling in surplus spoil including spreading, leveling, watering and well ramming in layers n. exc. 25 cm thick complete all as specified and directed.
Removing of excavted soil to a distance n. exc. 50 mtr and deposited where directed at a level not exceeding 1.5 mtr above the starting point complete all as specified and directed.
M&L for Sand cushioning to under ground cable providing with a layer of Sand 08 cm thick before laying of cable and 15 cm after laying of cable in trenches, hand punning complete all as specified and directed by Engr-in-charge (Note : Punning thickness of 18 cm will be measured for payment purpose)
M&L for Burnt bricks locally available, sub class 'B', laid flat for protection of under ground cable complete all as specified and directed at site.
Supply, laying , jointing and testing in repair of cable XLPE insulated screened PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 volts grade with stranded aluminum conductor of size 120 sqmm 3.5 core, laid in trenches/ducts or fixed to poles/walls or laid under roads/paths/drains/culverts including cable gland of suitable sizes and aluminium lugs for connection, complete all as specified and directed. Make: Finolex / KEI Industries Pvt Ltd / Polycab / Gloster / Universal Cables. Note: Excavation, earthwork, sand cushioning, brick protection shall be measured & paid for separately.
All as per Item No 45 above but size 3.5 core 95 sqmm complete all as specified and directed.
All as per Item No 45 above but size 3.5 core 70 sqmm complete all as specified and directed.
All as per Item No 45 above but size 3.5 core 50 sqmm complete all as specified and directed.
All as per Item No 45 above but size 3.5 core 35 sqmm complete all as specified and directed.
All as per Item No 45 above but size 3.5 core 25 sqmm complete all as specified and directed.
All as per Item No 45 above but size 4 core 16 Sqmm complete all as specified and directed.
All as per Item No 45 above but size 2 core 10 sqmm complete all as specified and directed.
All as per Item No 45 above but size 2 core 6 sqmm complete all as specified and directed.
Supply and fix LT overhead lines on existing poles, clamping and stringing of XLPE insulated AB cable 3 core x 70 sqmm + 1 core x 50 sqmm including terminating and jumping to the existing source of supply incl all jointing kits, nuts, bolts etc complete incl taking down old cable/conductor complete all as specified and directed.
Supply and fix in repair MS suspension clamp with eye hook suitable for aerial bunch cable complete all as specified and directed.
Supplying, installation and erection in true vertical position steel tubular swaged welded pole, 9.0 metre long, conforming to IS-2713 part-II, type 410 SP-31, complete with cast iron/MS base plate 6mm thick and of size 300x300mm, finial taper, pole cap, bolts, nuts, washers & screws etc., pole made out of ERW Mild steel tubing tubing including holes of required Nos and size for fixing of cross arms, painting with one coat of red oxide primer and two coats of aluminium paint on exposed surfaces and two coats of black bituminous paint for portion embedded in concrete, painting three signal red colour bands at lower portion of exposed pole starting from plinth block , each band of 300mm height at 300mm spacing, painting pole No with black paint by stenciled letters/figures of 8cm height, including taking down old pole any type complete all as specified and directed. Make : NATIONAL TUBING CO KANPUR, BHARAT CONDUIT & STEEL WORKS KANPUR, JINDAL STEEL PRODUCT, C&S ELECTRIC, SHIVAM METALS Note: Excavation, earth work and PCC in foundation of poles, coping etc shall be measured and paid separately in respected items.
Supply, stringing, stretching and binding in replacement with insulator, ACSR conductor of adequate size (Weasel /ferret/Mink) on LT Poles including providing of necessary jumpers, connecting all existing incoming and out going connections, trimming of trees approximately 2 mtr around conductor etc complete all as specified and directed. Make: ICC/NICCO/JAIPURIA/ALUMINIUM IND
Stringing only, ACSR conductor including providing of suitable binding wire for connecting the existing OH lines and providing of necessary jumpers, connecting all existing incoming and outgoing connections, trimming of trees, trimming of trees approximately 2 mtr around conductor etc complete all as specified and directed. Make: ICC/NICCO/JAIPURIA/ALUMINIUM IND
S&F in replacement Cradle hexagonal , rectangular fabricated with GI wire 4 mm dia on existing OH line, complete all as specified and directed.
Supply, stretching and binding in repair GI earth wire 4 mm dia on existing OH line complete all as specified and directed.
Dismantling of cross arms, bracings, supports, clamps etc of MS fabricated complete with all accessories viz nut, bolts, washer etc. complete all as specified and directed.
M&L for Cross arms, bracings, supports,clamps and back plates fabricated from structural steel sections including nuts,bolts,washers, welding , bending cold or hot, drilling holes for bolts,in any shape or sizes as indicated or directed and inclusive of one primer coat and two coats of alluminium paint complete all as specified and directed.
S&F in repair Pin type insulator Porcelain, vitreous white/ brown/ green insulator including one galvanized mild steel spindle, two galvanized iron washers and one galvanized iron nut, 100 mm height, 65 mm dia for 1100 volt grade, complete all as specified and directed. Make: PACTIL/BHEL/JAIPURIA/MASORE PORCILAIN
S&F in repair disc type insulator Porcelain, vitreous white/ brown/ green insulator including one galvanized mild steel spindle, two galvanized iron washers and one galvanized iron nut, 100 mm height, 65 mm dia for 1100 volt grade, complete all as specified and directed. Make: PACTIL/BHEL/JAIPURIA/MASORE PORCILAIN
S&F in replacement Shackle type porcelain , vitreous white, brown or green insulator including galvanised mild steel straps, wahsers, insulator bolts, wahsers and nuts, as working pressure 1100 volts height in 100 mm maximum dia 115 mm section of straps in 31 x 5 mm dia of bolts 14 mm complete all as specified and directed. Make: PACTIL/BHEL/JAIPURIA/MASORE PORCILAIN
S&F in repair Stay assembly comprising of MS stay plate of size 30cmx30cmx6mm thick, stay rod with nuts 215cm long, 20mm dia, MS/GI stay bow 40 cm length with 2 Nos GI thimbles, galvanized stay wire standard size 7/4mm, loop insulation size 90mmx65mm clearance of hole 16 mm & other accessories all as per SSR Part-1, Plate No.1 including necessary MS clamps, excavation earth work & PCC work complete all as specified and directed.
S&F in repair Tubing 'light grade' galvanised iron with all fittings and fixed to poles, walls etc. with flat iron clamps/bolts/nuts/washers or laid in floors/under roads complete of size 80 mm bore, complete all as specified and directed.
Cutting through existing bituminous road /PCC/floor/approx size width 15cm X 60cm depth along cross section of the road for laying of GI tubing/RCC pipe for encasing of cable and repairing the road to match with the original finish complete all as specified and directed.
M&L for Plain cement concrete (1:4:8) Type D-2 (using 40mm graded crushed stone aggregates) as in foundation for steel tubular poles including necessary form work and finishing the exposed surface even and smooth with out using extra cement complete all as specified and directed.
M&L for Plain cement concrete (1:2:4) Type B-1 using 20 mm graded crushed stone aggregates, as in coping of steel tubular poles foundation for steel tubular poles including necessary form work and finishing the exposed surface even and smooth with out using extra cement complete all as specified and directed.
Supply and fixing line separator with high quality PVC suitable for LT 1100 volts 4 lane OH aluminium conductor complete all as specified and directed.
Supply and fixing line separator with high quality PVC suitable for LT 1100 volts 2 lane OH aluminium conductor complete all as specified and directed.
M&L for Painting of LT panel including preparation of old surfaces by scrapping old paint completely and applying two coats of super enameled paint over a coat of red oxide primer complete all as specified and directed.
M&L for Painting to steel poles including cross arms, 'V' brackets, 'D' clamps, nuts, bolts, complete including painting with five strips of 30cm each with black and white paint in alternate strips from the base of pole upto 1.5mtr height complete, spray painting with two coat of synthetic enamel paint of first quality silver paint over a coat of red oxide primer after and including complete removal of old paint by scratching, rubbing complete all as specified and directed.
All as per Srl item No. 74 Above but two pole structure steel/RCC with cross arms, clamps, structure etc 1.1 KV complete all as specified and directed.
All as per Srl item No. 74 Above but four pole structure steel/RCC with cross arms, clamps, structure etc 1.1/11 KV, HT/LT complete all as specified and directed. Note for Srl item No. 74 to 76: Each job included scraping out, worn out old paint and making surface smooth suitable for application of paint
M&L for spreading evenly stone aggregate of size 40 mm in the sub station area complete all as specified and directed.
S&F in repair MCCB, 4 pole, 100 Amps, 415 volts, adjustable type with breaking capacity 16 KA Ics=75% Icu, complete all as specified and directed.
S&F in repair MCCB, 4 pole, 160 Amps, 415 volts, adjustable type with breaking capacity 36 KA Ics=100% Icu, complete all as specified and directed.
S&F in repair MCCB, 4 pole, 200 Amps, 415 volts, adjustable type with breaking capacity 36 KA Ics=100% Icu, complete all as specified and directed.
S&F in repair MCCB, 4 pole, 250 Amps, 415 volts, adjustable type with breaking capacity 36 KA Ics=100% Icu, complete all as specified and directed.
S&F in repair MCCB, 4 pole, 400 Amps, 415 volts, adjustable type with breaking capacity 36 KA Ics=100% Icu, complete all as specified and directed.
Supply, fixing, testing & commissioning of LT bus bar chamber box, platform mounted, suitable for 3 phase, 4 wire, 415 volts, 50 Hz AC supply and having 400 amps MCCB 36 KA, 4 pole for incoming and four Nos stepped type aluminium bus bar 200A for looping & branch connection system, the chamber shall be painted with powder coated paint , bus bar chamber shall be provided with suitable neoprene rubber gasket to make it completely dust and vermin proof and degree of protection not less than IP-55, bus bar chamber shall be made out of 3.15 mm thick CRCA mild steel sheet, front door (01 layer) and rear door (01 layer) opening facility and side slanting canopy type roof on top and angle iron padestal frame including PCC work, 0.6 Mtr above ground level, grouting etc including provision of suitable size of cable glands, cable lugs,nut, bolts,washers etc. (The bottom portion of enclosure shall be minimum 60 cm above ground level of legs of angle iron), including taking down old bus bar chamber box, complete all as specified and directed.
S&F in repair 1100 Volts grade heavy duty cable PVC insulated aluminum solid conductor, served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 metre apart including 4 mm suspension wire, one twin core cable flat or circular, size of aluminum conductor 6 sq mm, complete all as specified and directed. Make : Finolex / KEI Industries Pvt Ltd / Polycab / Gloster / Universal Cables.
All as per Srl item No. 85 Above but of size 10 Sqmm complete all as specified and directed.
S&F in repair Earthing complete with galvanized steel plate electrode 600 mm x 600 mm x 6.0 mm thick, burried directly in ground vertically in pit of depth not less than 2.25 metre below normal ground level with top edge of the earth plate at a depth not less than 1.5 metre below normal ground level surrounded from all sides with mixture of charcoal and common salt in alternate layers and electrode connected to galvanized iron strip 32 x 6 mm size by means of GI bolts, nuts, check nuts and washers, earth strip protected by galvanized steel pipe 40 mm bore (light grade) connected to main switch board or any other electrical equipment all as shown in electrical plate No. 3 of SSR-2009 Part I and including necessary excavation and earth work in any type of soil, 20 mm bore medium grade GI pipe for watering, funnel with wire mesh, PCC (1:3:6), type C-1 chamber, RCC (1:2:4), type B-1, reinforced with 8 mm dia TMT bars @ 15 cm c/c both way for cover and MS frame etc., complete all as specified and directed. NOTE: The unit rate includes earth strip and protection pipe upto (maximum 7.5 metre from earth plate) earth point/test point.
S&F in repair Earthing complete with galvanized steel plate electrode 600 mm x 600 mm x 6.0 mm thick, burried directly in ground vertically in pit of depth not less than 2.25 metre below normal ground level with top edge of the earth plate at a depth not less than 1.5 metre below normal ground level surrounded from all sides with mixture of charcoal and common salt in alternate layers and electrode connected to galvanized iron wire 4 mm dia by means of GI bolts, nuts, check nuts and washers, earth wire protected by galvanized iron pipe 15 mm bore (light grade) connected to main switch board or any other electrical equipment all as shown in electrical plate No. 3 of SSR-2009 Part I and including necessary excavation and earth work in any type of soil, 20 mm bore medium grade GI pipe for watering, funnel with wire mesh, PCC (1:3:6), type C-1 chamber, RCC (1:2:4), type B-1, reinforced with 8 mm dia TMT bars @ 15 cm c/c both way for cover and MS frame etc., complete all as specified and directed. NOTE: The unit rate includes earth wire and protection pipe upto (maximum 7.5 metre from earth plate) earth point/test point.
S&F in repair Single pointed air termination Aluminium rod 12mm dia, 300 mm long complete all as specified and directed.
S&F in repair Test point terminal block made of gun metal or phosphorous bronze of size 75x75 x 25mm drilled and screwed including 3 Nos 8mm dia 25mm long hexagonal head brass screws including box of size 90 x 90 x 90mm made of 1.6mm plain sheet and screwed to GI pipe/ wall for protection of test point complete all as specified and directed.
S&F in repair earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required 32 x 6 mm galvanised iron strip, complete all as specified and directed.
S&F in repair aluminium strip 25 x 3.15mm with saddles and fixing screws, insulators rawl plugs etc for conductor for roof and fixed on wall upto test point, complete all as specified and directed.
S&F in repair rubber insulating mat of size 2mx1mx12mm thick, ISI marked, complete all as specified and directed.
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .