| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹56.5 LAccepted-AOC | L1 | Accepted-AOC Lowest and accepted | |
| 2 | L2₹65.8 L+₹8.3 L (14.5%)Rejected-Finance 11 A KUTCHERY ROAD BALUGANJ AGRA 282001 UP | AGRA | UTTAR PRADESH | 282001 | L2 | Rejected-Finance L2 | |
| 3 | L3₹67.0 L+₹9.5 L (16.6%)Rejected-Finance SHOP NO 10 BMC SHOPPING CENTRE MITHA NAGAR GOREGAON WEST MUMBAI 400 104 | MUMBAI | MUMBAI SUBURBAN | MAHARASHTRA | 400104 | L3 | Rejected-Finance L3 | |
| 4 | L4₹68.4 L+₹10.9 L (18.9%)Rejected-Finance 1 14 SUJAL MANSION B BLOCK BHANGWADI KALBADEVI ROAD MUMBAI 400 002 | MUMBAI | MAHARASHTRA | 400002 | L4 | Rejected-Finance L4 | |
| 5 | L5₹69.8 L+₹12.3 L (21.4%)Rejected-Finance PLOT NO 1134 1196 MORIVALI VILLAGE TAL AMBARNATH DIST THANE AMBERNATH 421505 | AMBERNATH | THANE | MAHARASHTRA | 421505 | L5 | Rejected-Finance L5 |
| Sl No | Description | Qty | Unit | NOEL ENGINEERS L1 | R J ENTERPRISES L6 | Chakshu Enterprise L4 | Shree Ayyappa Engineering L3 | cooltech engineering services L7 | Shetty Construction Co L8 | R.C. Magla and Co. L2 | shakti engineering and electrical works L5 |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1.00 | M&L for taking down unserviceable High Mast/ flood / LED Light Fitting Set fixed on pole at height more than -9 Mtrs and upto 15 Mtrs of any Watt , Make, for repairing the same by opening Cover, replacing unservicable Parts as required / ordered, such as, Electronic Driver, PCB, including Cleaning of LED Flood light housing, glass cover etc and refixing in same or location as indicated by Engnr-in Charge all as specified and as directed.
NOTE :–
(a) Spare Parts such as Electronic Drive , PCB, etc. wherever required will be measured and paid under appropriate Item(s) as ‘Supply only’.
(b) PVC insulated and PVC Round Sheathed, Multicore Annealed Bare Copper Conductor (flexible) industrial cable of size 1.5 Sqmm 3 Core for Voltage Grade
1100 Volt, where ever required upto 1.5 Mtr length and Labour Element for replacement of unserviceable Parts shall deemed to be included in the Unit rate Quoted.
(iii) T &P such as ladder, Vehicle mounted sky lift boom, with Vehicle shall be arranged by the contractor without any extra cost from the department | 125 | Each | 300 ₹37,500 | 286 ₹35,750 | 330 ₹41,250 | 250 ₹31,250 | 300 ₹37,500 | 303 ₹37,875 | 285 ₹35,625 | 120 ₹15,000 Lowest |
| 2.00 | M&L for taking down LED Street Light Fitting fixed on pole at maximum height not more than -9 Mtrs, building wall, of any Watt, Make, for repairing the same by opening Cover, replacing unservicable Parts as required / ordered, such as, Electronic Driver, PCB, including Cleaning of LED street light housing, glass cover etc replacing rubber bedding where ever required and refixing in same or location as indicated by Engnr-in Charge all as specified and as directed.
NOTE :–
(a) Spare Parts such as Electronic Drive , PCB, etc. wherever required will be measured and paid under appropriate Item(s) as ‘Supply only’.
(b) PVC insulated and PVC Round Sheathed, Multicore Annealed Bare Copper Conductor (flexible) industrial cable of size 1.5 Sqmm 3 Core for Voltage Grade
1100 Volt, where ever required upto 1.5 Mtr length and Labour Element for replacement of unserviceable Parts shall deemed to be included in the Unit rate Quoted.
(iii) T &P such as ladder, Vehicle mounted sky lift boom, with Vehicle shall be arranged by the contractor without any extra cost from the department | 300 | Each | 250 ₹75,000 | 223 ₹66,900 | 265 ₹79,500 | 250 ₹75,000 | 300 ₹90,000 | 238 ₹71,400 | 285 ₹85,500 | 120 ₹36,000 Lowest |
| 3.00 | M&L for taking down LED Flood Light Fitting fixed on pole, building - wall, watch Towers of any Watt, Make, for repairing the same by opening Cover, replacing unservicable Parts as required / ordered, such as, Electronic Driver, PCB, including Cleaning of LED street light housing, glass cover etc replacing rubber bedding where ever required and refixing in same or location as indicated by Engnr-in Charge all as specified and as directed.
NOTE :–
(a) Spare Parts such as Electronic Drive , PCB, etc. wherever required will be measured and paid under appropriate Item(s) as ‘Supply only’.
(b) PVC insulated and PVC Round Sheathed, Multicore Annealed Bare Copper Conductor (flexible) industrial cable of size 1.5 Sqmm 3 Core for Voltage Grade
1100 Volt, where ever required upto 1.5 Mtr length and Labour Element for replacement of unserviceable Parts shall deemed to be included in the Unit rate Quoted.
(iii) T &P such as ladder, Vehicle mounted sky lift boom, with Vehicle shall be arranged by the contractor without any extra cost from the department | 125 | Each | 250 ₹31,250 | 298 ₹37,250 | 340 ₹42,500 | 250 ₹31,250 | 300 ₹37,500 | 313 ₹39,125 | 285 ₹35,625 | 120 ₹15,000 Lowest |
| 4.00 | M&L for taking down LED High Bay Light Fitting fixed inside building -ceiling / on walls of any Watt, Make, for repairing the same by opening Cover, replacing unservicable Parts as required / ordered, such as, Electronic Driver, PCB, including Cleaning of LED street light housing, glass cover etc replacing rubber bedding where ever required and refixing in same or location as indicated by Engnr-in Charge all as specified and as directed.
NOTE :–
(a) Spare Parts such as Electronic Drive , PCB, etc. wherever required will be measured and paid under appropriate Item(s) as ‘Supply only’.
(b) PVC insulated and PVC Round Sheathed, Multicore Annealed Bare Copper Conductor (flexible) industrial cable of size 1.5 Sqmm 3 Core for Voltage Grade
1100 Volt, where ever required upto 1.5 Mtr length and Labour Element for replacement of unserviceable Parts shall deemed to be included in the Unit rate Quoted.
(iii) T &P such as ladder, Vehicle mounted sky lift boom, with Vehicle shall be arranged by the contractor without any extra cost from the department | 60 | Each | 250 ₹15,000 | 298 ₹17,880 | 340 ₹20,400 | 250 ₹15,000 | 300 ₹18,000 | 313 ₹18,780 | 285 ₹17,100 | 120 ₹7,200 Lowest |
| 5.00 | M&L for taking down LED Decorative Pole filght fittings fixed on pole at maximum height not more than 4 Mtrs, of any Watt, Make, for repairing the same by opening Cover, replacing unservicable Parts as required / ordered, such as, Electronic Driver, PCB, including Cleaning of LED street light housing, glass cover etc replacing rubber bedding where ever required and refixing in same or location as indicated by Engnr-in Charge all as specified and as directed.
NOTE :–
(a) Spare Parts such as Electronic Drive , PCB, etc. wherever required will be measured and paid under appropriate Item(s) as ‘Supply only’.
(b) PVC insulated and PVC Round Sheathed, Multicore Annealed Bare Copper Conductor (flexible) industrial cable of size 1.5 Sqmm 3 Core for Voltage Grade
1100 Volt, where ever required upto 1.5 Mtr length and Labour Element for replacement of unserviceable Parts shall deemed to be included in the Unit rate Quoted.
(iii) T &P such as ladder, Vehicle mounted sky lift boom, with Vehicle shall be arranged by the contractor without any extra cost from the department | 150 | Each | 250 ₹37,500 | 108 ₹16,200 | 150 ₹22,500 | 100 ₹15,000 | 60 ₹9,000 | 123 ₹18,450 | 110 ₹16,500 | 50 ₹7,500 Lowest |
| 6.00Supply only the following Items to incorporate against relevant repairable (street lights) item Ser No 1 to 5 here-in- before of existing suitable Make as required / ordered by Engnr-in- Charge . | |||||||||||
| 6.01 | LED Driver 25W (42-60)V -400 MA class1 encapsulated (In house), for LED street light -25 Watt, cool/ Warm white, Make Jaquar (Driver Code -ZHL-WHT-JQMPCRSRT25X) or Equivalent Make | 20 | Each | 450 ₹9,000 | 937 ₹18,740 | 936 ₹18,720 | 500 ₹10,000 | 600 ₹12,000 | 934 ₹18,680 | 410 ₹8,200 Lowest | 850 ₹17,000 |
| 6.02 | LED Driver 36W Class 1 encapsulated 30-42V, 950MA,SMT for LED street light -36 Watt, cool/ Warm/ Neutral white, Make Jaquar (Driver Code -ZCO-WHT-JQMPCRSRT36X) or Equivalent Make | 20 | Each | 450 ₹9,000 | 1,037 ₹20,740 | 1,036 ₹20,720 | 600 ₹12,000 | 670 ₹13,400 | 1,034 ₹20,680 | 410 ₹8,200 Lowest | 1,200 ₹24,000 |
| 6.03 | LED Driver 45W street light (54V-750MA) Class 1 encapsulated (for in house street light) for LED street light top opening -45 Watt, cool/ Warm/ Neutral white, Make Jaquar (Driver Code -ZCO-WHT-JQMSRT15S045) or Equivalent Make | 70 | Each | 450 ₹31,500 Lowest | 1,037 ₹72,590 | 1,036 ₹72,520 | 600 ₹42,000 | 670 ₹46,900 | 1,034 ₹72,380 | 450 ₹31,500 Lowest | 900 ₹63,000 |
| 6.04 | LED Driver 60 W Class1 Encapsulated 72-84V 750MA, SMT, For LED Street Light top opening 60 Watt, Warm/ cool white, Make Jaquar (Driver Code -ZCO-WHT-JQMSRT015060) or Equivalent Make | 60 | Each | 720 ₹43,200 | 1,237 ₹74,220 | 1,236 ₹74,160 | 700 ₹42,000 | 800 ₹48,000 | 1,234 ₹74,040 | 520 ₹31,200 Lowest | 900 ₹54,000 |
Tender Value
₹60.0 L
EMD Value
₹1.1 L
Closing Date
28 Jan 2026, 6:00 pmClosed
CWE (SUBS) MUMBAI
Commander Works Engineer Subs NCHC Powai Bhandup Post Office Mumbai 400 078
REPAIR AND REPLACEMENT OF OBSOLETE LT PANELS, APFC PANELS, LT CABLES AND JOINTS AND STREET LIGHTS AT INS HAMLA
2025_MES_746773_1
8418/E8
Open Tender
Electrical and Maintenance Works
Works
330 days
HAMLA
Please refer Tender documents.
8 documents required · 8 mandatory
₹1,000
GE (NW) BHANDUP
₹1.1 L
15 Mar 2026
1 Jan 2026
30 Jan 2026
1 Jan 2026
28 Jan 2026
21 Jan 2026
M&L for taking down unserviceable High Mast/ flood / LED Light Fitting Set fixed on pole at height more than -9 Mtrs and upto 15 Mtrs of any Watt , Make, for repairing the same by opening Cover, replacing unservicable Parts as required / ordered, such as, Electronic Driver, PCB, including Cleaning of LED Flood light housing, glass cover etc and refixing in same or location as indicated by Engnr-in Charge all as specified and as directed. NOTE :– (a) Spare Parts such as Electronic Drive , PCB, etc. wherever required will be measured and paid under appropriate Item(s) as ‘Supply only’. (b) PVC insulated and PVC Round Sheathed, Multicore Annealed Bare Copper Conductor (flexible) industrial cable of size 1.5 Sqmm 3 Core for Voltage Grade 1100 Volt, where ever required upto 1.5 Mtr length and Labour Element for replacement of unserviceable Parts shall deemed to be included in the Unit rate Quoted. (iii) T &P such as ladder, Vehicle mounted sky lift boom, with Vehicle shall be arranged by the contractor without any extra cost from the department
M&L for taking down LED Street Light Fitting fixed on pole at maximum height not more than -9 Mtrs, building wall, of any Watt, Make, for repairing the same by opening Cover, replacing unservicable Parts as required / ordered, such as, Electronic Driver, PCB, including Cleaning of LED street light housing, glass cover etc replacing rubber bedding where ever required and refixing in same or location as indicated by Engnr-in Charge all as specified and as directed. NOTE :– (a) Spare Parts such as Electronic Drive , PCB, etc. wherever required will be measured and paid under appropriate Item(s) as ‘Supply only’. (b) PVC insulated and PVC Round Sheathed, Multicore Annealed Bare Copper Conductor (flexible) industrial cable of size 1.5 Sqmm 3 Core for Voltage Grade 1100 Volt, where ever required upto 1.5 Mtr length and Labour Element for replacement of unserviceable Parts shall deemed to be included in the Unit rate Quoted. (iii) T &P such as ladder, Vehicle mounted sky lift boom, with Vehicle shall be arranged by the contractor without any extra cost from the department
M&L for taking down LED Flood Light Fitting fixed on pole, building - wall, watch Towers of any Watt, Make, for repairing the same by opening Cover, replacing unservicable Parts as required / ordered, such as, Electronic Driver, PCB, including Cleaning of LED street light housing, glass cover etc replacing rubber bedding where ever required and refixing in same or location as indicated by Engnr-in Charge all as specified and as directed. NOTE :– (a) Spare Parts such as Electronic Drive , PCB, etc. wherever required will be measured and paid under appropriate Item(s) as ‘Supply only’. (b) PVC insulated and PVC Round Sheathed, Multicore Annealed Bare Copper Conductor (flexible) industrial cable of size 1.5 Sqmm 3 Core for Voltage Grade 1100 Volt, where ever required upto 1.5 Mtr length and Labour Element for replacement of unserviceable Parts shall deemed to be included in the Unit rate Quoted. (iii) T &P such as ladder, Vehicle mounted sky lift boom, with Vehicle shall be arranged by the contractor without any extra cost from the department
M&L for taking down LED High Bay Light Fitting fixed inside building -ceiling / on walls of any Watt, Make, for repairing the same by opening Cover, replacing unservicable Parts as required / ordered, such as, Electronic Driver, PCB, including Cleaning of LED street light housing, glass cover etc replacing rubber bedding where ever required and refixing in same or location as indicated by Engnr-in Charge all as specified and as directed. NOTE :– (a) Spare Parts such as Electronic Drive , PCB, etc. wherever required will be measured and paid under appropriate Item(s) as ‘Supply only’. (b) PVC insulated and PVC Round Sheathed, Multicore Annealed Bare Copper Conductor (flexible) industrial cable of size 1.5 Sqmm 3 Core for Voltage Grade 1100 Volt, where ever required upto 1.5 Mtr length and Labour Element for replacement of unserviceable Parts shall deemed to be included in the Unit rate Quoted. (iii) T &P such as ladder, Vehicle mounted sky lift boom, with Vehicle shall be arranged by the contractor without any extra cost from the department
M&L for taking down LED Decorative Pole filght fittings fixed on pole at maximum height not more than 4 Mtrs, of any Watt, Make, for repairing the same by opening Cover, replacing unservicable Parts as required / ordered, such as, Electronic Driver, PCB, including Cleaning of LED street light housing, glass cover etc replacing rubber bedding where ever required and refixing in same or location as indicated by Engnr-in Charge all as specified and as directed. NOTE :– (a) Spare Parts such as Electronic Drive , PCB, etc. wherever required will be measured and paid under appropriate Item(s) as ‘Supply only’. (b) PVC insulated and PVC Round Sheathed, Multicore Annealed Bare Copper Conductor (flexible) industrial cable of size 1.5 Sqmm 3 Core for Voltage Grade 1100 Volt, where ever required upto 1.5 Mtr length and Labour Element for replacement of unserviceable Parts shall deemed to be included in the Unit rate Quoted. (iii) T &P such as ladder, Vehicle mounted sky lift boom, with Vehicle shall be arranged by the contractor without any extra cost from the department
Supply only the following Items to incorporate against relevant repairable (street lights) item Ser No 1 to 5 here-in- before of existing suitable Make as required / ordered by Engnr-in- Charge .
LED Driver 25W (42-60)V -400 MA class1 encapsulated (In house), for LED street light -25 Watt, cool/ Warm white, Make Jaquar (Driver Code -ZHL-WHT-JQMPCRSRT25X) or Equivalent Make
LED Driver 36W Class 1 encapsulated 30-42V, 950MA,SMT for LED street light -36 Watt, cool/ Warm/ Neutral white, Make Jaquar (Driver Code -ZCO-WHT-JQMPCRSRT36X) or Equivalent Make
LED Driver 45W street light (54V-750MA) Class 1 encapsulated (for in house street light) for LED street light top opening -45 Watt, cool/ Warm/ Neutral white, Make Jaquar (Driver Code -ZCO-WHT-JQMSRT15S045) or Equivalent Make
LED Driver 60 W Class1 Encapsulated 72-84V 750MA, SMT, For LED Street Light top opening 60 Watt, Warm/ cool white, Make Jaquar (Driver Code -ZCO-WHT-JQMSRT015060) or Equivalent Make
Driver for 70W street light OP 850MA OP 70-90VDC MI, for LED street light top opening - 72 Watt, cool/ Warm white, Make Jaquar (Driver Code -ZCO-WHT-JQMSRT015072) or Equivalent Make
Driver for 90W street light (84-126)V-700MA encapsulated Z (in house) for LED street light top opening -150 Watt, cool white, Make Jaquar (Driver Code -ZCO-WHT-JQMSRTL2S090) or Equivalent Make
Driver for 110 W street light 750MA,132V, JFR, for LED street light top opening -90 / 100 / 120 / 200 Watt Warm/ cool white, Make Jaquar (Driver Code -ZCO-WHT-JQMSRTL2S090) or Equivalent Make
Driver 120W (84-108)V- 820MA Class 1 Encapsulated 4KV, 440V (In house) JFR, For LED Street Light top opening - 190/200 Watt, Warm/ cool white, Make Jaquar (Driver Code -ZCO-WHT-JQMSRTTOS200) or Equivalent Make
M&L for preparing old painted /rusted surfaces by scraping / scrubing using steel wool or a scouring pad, etc. from Steel Tubular / octagonal Poles, Cable Protection Pipe, Brackets, (above the Planting Depth and PCC Copings of Pole length 5-7 Mtrs ), applying one Coat of oil-based rust-preventative ( inhibitor) primer for complete pole, alternate blue & yellow Strips from bottom above PCC coping two coat Painting (4 No. Each Strip 150 mm wide) and remaining portion of Pole Cable Protection Pipe, Brackets, etc. treated with Two Coats of Rust O Seal ( Make Asian) Paint, colour shade as directed by Engnr-in- Charge.
M&L for preparing old painted / rusted surfaces by scraping / scrubing using steel wool or a scouring pad, etc. from Decorative cast/ Galvanised Iron Post Top Lantern Poles, Brackets, (above the Planting Depth and PCC Copings of Pole Height 4-5 Mtrs ), applying one Coat of oil-based rust-preventative ( inhibitor) primer for complete pole, and Painting with Two Coats of Rust O Seal ( Make Asian) Paint over coat of primer, colour shade as directed by Engnr-in- Charge.
M&L for preparing old painted / rusted surfaces by scraping / scrubing using steel wool or a scouring pad, etc. from Galvanised Iron Post Top Lantern Poles, (above the Planting Depth and PCC Copings of Pole Height 2 Mtrs ), applying one Coat of oil-based rust-preventative ( inhibitor) primer for complete pole, and Painting with Two Coats of Rust O Seal ( Make Asian) Paint over coat of primer, colour shade as directed by Engnr-in- Charge.
Material and Labour for Radium Vinyl Sticker, (Thickness not less than 2mm,) water proof, wear resistant, back with sticker, Resistant to fading, cracking, and peeling, colour as directed by Engnr-in- Charge, for Numbering of Poles, cut to customizable size font in size 6 cms Height and width not less than 4 cms with letters as (NSB/SL-01, 50AL/SL-01, OTM/SL-01) on Base of 15cm x15cm square Radium Vinyl sticker complete all as specified and as directed. Note- Ser No i.e 001 will change on each Pole as per site requirement. Base and Numbering Radium Vinyl Sticker will be of diffirent colours as directed by Engnr-in-Charge.
Material and Labour for Felling of Tree girth exc. 30 cm and not exc 100 cm including cutting of trunk, and branches, stacking of serviceable material and disposal of unserviceable material to a distance n exc. 50 m and clearing site around obstructing street Lights in close proximity of pole, Pump House, Sub Station Bldgs complete all as specified and as directed.
Cutting unaxious green growth and wild grass by manual labour or by machine at Electrical Installation Premises, around Pole, along the boundary Fencing, removing rubbish from the Site of Work and deposting where directed not exc. 100 Metre from the starting Point, complete all as specified and as directed. NOTE : (i) The Item shall be operated maximum 3 times in the entire period of the Contract and the measurement will be taken every time independently for Payment. (ii) Creapers climbed on Installations compound chain link fencing / wall shall be removed cleared by contractor without any extra cost from the department.
Supply and fixing PVC insulated and PVC Round Sheathed, 1.50 sq.mm 3 Core Multicore Annealed Bare Copper Conductor (flexible) industrial cable for Voltage Grade 1100 Volt, Conforming to IS 694 : 2010 complete all as specified and as directed
Supply and fixing PVC insulated and PVC Round Sheathed, 1.0 sq.mm 3 Core Multicore Annealed Bare Copper Conductor (flexible) industrial cable for Voltage Grade 1100 Volt, Conforming to IS 694 : 2010 complete all as specified and as directed
Supply and fixing as in replacement heavy duty, easy to install, open Type Bakelite Connector Plate, 100 Amps 4 Bolt Type (TPN) 1100 volts grade with necessary nuts bolts and washers of adequate size, length and mounting support complete all as specified and as directed
Supply and fixing as in replacement heavy duty, easy to install, open Type Bakelite Connector Plate, 63 Amps 4 Bolt Type (TPN) 1100 volts grade with necessary nuts bolts and washers of adequate size, length and mounting support complete all as specified and as directed
Excavation in Trenches not exc 1.50 Metre wide and not exc 1.50 Metre depth for laying of UG Cable etc and getting out in Soft/Loose Soil, complete all as specified and as directed.
Excavation in Trenches not exc 1.50 Metre wide and not exc 1.50 Metre depth for laying of UG Cable etc and getting out in Hard/ Dense Soil, complete all as specified and as directed.
Returning, Filling in including Spreading, Leveling, Watering and Well Ramming in layers not exc. 25 Cm thick in Soils, complete all as specified and as directed.
Removing Surplus excavated Soil to a distance not exc 50.00 Metre away and depositing where directed at a level not exc 1.50 Metre above the Starting Point, complete all as specified and as directed.
M&L Cement Concrete 1:3:6 (40mm graded aggregate) Type C2 as in Foundation of Poles, Stays, grounting of panel and making good disturbed road surfaces including necessary Formwork (as/if required) complete all as specified and as directed. NOTE : (i) Unserviceable Poles will be dismantled at Ground Level and disturbed ground shall be made good as directed for which Earthwork, demolition of Cement Concrete, etc. will not be measured and paid separately. (ii) Earth work, demolition of cement concrete for taking out serviceable poles will be measured and paid seperately under relevant item
M&L Cement Concrete 1:2:4 (20mm graded aggregate) Type B1 as in Coping of Poles, etc. and finishing the Concrete surfaces Fair and Even including necessary Formwork required at Site(s), complete all as specified and as directed. NOTE : (i) Unserviceable Poles will be dismantled at Ground Level and disturbed ground shall be made good as directed for which Earthwork, demolition of Cement Concrete, etc. will not be measured and paid separately. (ii) Earth work, demolition of cement concrete for taking out serviceable poles will be measured and paid seperately under relevant item
Dismantling unserviceable Steel Tubular / Pipe Poles of any description and any size setting aside for reuse or transporting to store for stacking including demolition of Cement Concrete (as/if required) and made good disturbed Ground, complete all as specified and as directed. NOTE : (i) Unserviceable Poles will be dismantled at Ground Level and disturbed ground shall be made good as directed for which Earthwork, demolition of Cement Concrete, etc. will not be measured and paid separately. (ii) Earth work, demolition of cement concrete for taking out serviceable poles will be measured and paid seperately under relevant item
Erecting LT Steel Tubular Swaged / Hot-Dip Galvanized (HDG) Octagonal Poles with decorative single/ double arm bracket of any size /description upto 8.5 metres long including, Mild Steel Bolts, Nuts, Screws, for (Serviceable Pole obtained from Item No. 28 here-in-before) complete all as specified and as directed. NOTE :– (a) Earthwork, Cement Concrete, etc. will be measured and paid under approprite Items. (b) Cost of transporting the Serviceable Pole to location of work within 500 mtr is deemed to be included in the Quoted Unit Rate. (c) foundation bolts (4 nos with 3 nos of nuts and washers in each) for Hot-Dip Galvanized (HDG) Octagonal Poles as recommended by OEM for serviceable poles to reuse at same or other location shall be provided by the contrator without any extra cost from the department.
Supply & erecting Hot-Dip Galvanized (HDG) Octagonal Poles for Street Lighting in single section of 5 Mtr. height ,Top – 70mm dia, Bottom – 130mm dia and 3mm thickness sheet. Base plate of minimum dimension 200mm X 200mm X 12 mm, including foundation bolts (4 nos with 3 nos of nuts and washers in each), with decorative single arm bracket for mounting the light fittings 1000 mm long, bent at an angle of 120 degree, with necessary holding brackets, hold fasts etc, bakelite sheet with one 6A SP MCB and 16 sqmm stud type connector ( 4 nos) inside the pole at door opening for cable connection, complete all as specified and as directed Make - Bajaj Type BOP-5030 or Equivalent ) NOTE : Earthwork, Cement Concrete for foundation , etc. will be measured and paid under approprite Items. Make - Bajaj Type BOP-7030 or Equivalent )
Supply & erecting Hot-Dip Galvanized (HDG) Octagonal Poles for Street Lighting in single section of 6 Mtr. height ,Top – 70mm dia, Bottom – 130mm dia and 3mm thickness sheet. Base plate of minimum dimension 200mm X 200mm X 12 mm, including foundation bolts (4 nos with 3 nos of nuts and washers in each), with decorative single arm bracket for mounting the light fittings 1000 mm long, bent at an angle of 120 degree, with necessary holding brackets, hold fasts etc, bakelite sheet with one 6A SP MCB and stud connector (4 nos) inside the pole at door opening for cable connection, complete all as specified and as directed. Make - Bajaj Type BOP-6030 or Equivalent ) NOTE : Earthwork, Cement Concrete for foundation , etc. will be measured and paid under approprite Items. Make - Bajaj Type BOP-7030 or Equivalent)
Supply & erecting Hot-Dip Galvanized (HDG) Octagonal Poles for Street Lighting in single section of 7 Mtr. height ,Top – 70mm dia, Bottom – 130mm dia and 3mm thickness sheet. Base plate of minimum dimension 200mm X 200mm X 12 mm, including foundation bolts (4 nos with 3 nos of nuts and washers in each), with decorative single arm bracket for mounting the light fittings 1000 mm long, bent at an angle of 120 degree, with necessary holding brackets, hold fasts etc, bakelite sheet with one 6A SP MCB and stud connector ( 4 nos) inside the pole at door opening for cable connection, complete all as specified and as directed. NOTE : Earthwork, Cement Concrete for foundation , etc. will be measured and paid under approprite Items. Make - Bajaj Type BOP-7030 or Equivalent)
Supply and fixing made to Assembly double Arm bracket 1.5 Mtr Long suitable for 70mm Top octagonal Pole complete all as specified and as directed
Supply and fixing made to Assembly double Arm bracket 2 Mtr Long suitable for 70mm Top octagonal Pole complete all as specified and as directed
Supply and fixing, Modern decorative Post Top pole single arm made out of (Galvanised and Aluminium) 4 Mtr in Height from the ground level of Dia 114 X 60 mm with wall thickness not less than 3mm, base plate (250 mm x 250 mm x 12 mm thickness), Make- Antra 7011 C, Make- Lucker ( Heavy Duty) - or equivalent in Jaquar, Prestige castings, 4 Way Loop in Loop out PVC connector mounted on appropriate size Bakelite sheet, complete with and including Energy saving, long life aesthetically designed die-cast landscape luminaire with high power 50 Wattage system LED as light source, 240 Volts .Make- Osram, Shakti ( Cat No- SZPSCPD050) Powered by an integral electronic driver with output short circuit protection, surge protection & other safety tests. Elegantly designed housing and heat sink for efficient thermal management, sturdiness and excellent corrosion resistance. Lens- Heat resistant toughened bell shaped Transparent acrylic diffuser, etc all as specified and as directed. Note : (i) Machine Polish, painting of pole with epoxy zinc rich penetrating primer finished with polyurethane base paint with 45 micron coat in Black and golden colour as approved of Premium make shall deemed to be included in the unit quoated Rate. (ii) PCC for foundation required shall be measured and paid seperately under relevant item of schedule,How ever Nuts bolts washers of suitable size as ordered by OEM for planting pole in foundation shall deemed to be included in the unit rate quoated.
Supply and fixing, Modern decorative Post Top pole double arm made out of (Galvanised and Aluminium) - 4 Mtr in Height from the ground level of Dia 114 X 60 mm with wall thickness not less than 3mm, base plate (250 mm x 250 mm x 12 mm thickness), Make- Antra 7011 D, Make- Lucker ( Heavy Duty) - or equivalent in Jaquar, Prestige castings, 4 Way Loop in Loop out PVC connector mounted on appropriate size Bakelite sheet, complete with and including Energy saving, long life aesthetically designed die-cast landscape luminaire with high power 50 Wattage system LED as light source, 240 Volts .Make- Osram, Shakti ( Cat No- SZPSCPD050) Powered by an integral electronic driver with output short circuit protection, surge protection & other safety tests. Elegantly designed housing and heat sink for efficient thermal management, sturdiness and excellent corrosion resistance. Lens- Heat resistant toughened bell shaped Transparent acrylic diffuser, etc all as specified and as directed Note (i) Machine Polish, painting of pole with epoxy zinc rich penetrating primer finished with polyurethane base paint with 45 micron coat in Black and golden colour as approved of Premium make shall deemed to be included in the unit quoated Rate. (ii) PCC for foundation required shall be measured and paid seperately under relevant item of schedule,How ever Nuts bolts washers of suitable size as ordered by OEM for planting pole in foundation shall deemed to be included in the unit rate quoated.
Supply and fixing, Modern decorative Post Top pole made out of (Galvanised and Aluminium) 3 Mtr in Height from the ground level of Dia 114 X 60 mm with wall thickness not less than 3mm, base plate (250 mm x 250 mm x 12 mm thickness), Make- Antra 7014 D, Make- Lucker ( Heavy Duty) - or equivalent inJaquar Prestige castings, 4 Way Loop in Loop out PVC connector mounted on appropriate size Bakelite sheet, complete with and including Energy saving, long life aesthetically designed die-cast landscape luminaire with high power 50 Wattage system LED as light source, 240 Volts Make- Osram, Lucker ( Cat No- LPL50L BK) Powered by an integral electronic driver with output short circuit protection, surge protection & other safety tests. Elegantly designed housing and heat sink for efficient thermal management, sturdiness and excellent corrosion resistance. Two nos. aluminum arms to support the housing. Lens- Heat resistant toughened bell shaped Transparent acrylic diffuser, etc all as specified and as directed Note (i) Machine Polish, painting of pole with epoxy zinc rich penetrating primer finished with polyurethane base paint with 45 micron coat in Black and golden colour as approved of Premium make shall deemed to be included in the unit quoated Rate. (ii) PCC for foundation required shall be measured and paid seperately under relevant item of schedule,How ever Nuts bolts washers of suitable size as ordered by OEM for planting pole in foundation shall deemed to be included in the unit rate quoated.
Supply and fixing, Modern decorative Post Top pole made out of (Galvanised Iron) 4 Mtr in Height from the ground level with wall thickness not less than 3mm , base plate not less than (250 mm x 250 mm x 12 mm thickness), Make- Jaquar Cat No- OPO-BLK-POLBKOD11476400M or equivalent in Crompton, Philips, 4 Way Loop in Loop out PVC connector mounted on appropriate size Bakelite sheet, complete all as specified and as directed. Note (i) Machine Polish, painting of pole with epoxy zinc rich penetrating primer finished with polyurethane base paint with 45 micron coat in Black and golden colour as approved of Premium make shall deemed to be included in the unit quoated Rate. (ii) PCC for foundation required shall be measured and paid seperately under relevant item of schedule,How ever Nuts bolts washers of suitable size as ordered by OEM for planting pole in foundation shall deemed to be included in the unit rate quoated.
Supply and fixing, Modern decorative Post Top pole made out of (Galvanised Iron) 5 Mtr in Height from the ground level with wall thickness not less than 3mm , base plate not less than (250 mm x 250 mm x 12 mm thickness),Make- Jaquar Cat No- OPO-BLK-POLBKOD11476500M or equivalent in Crompton, Philips,, 4 Way Loop in Loop out PVC connector mounted on appropriate size Bakelite sheet, complete all as specified and as directed. Note (i) Machine Polish, painting of pole with epoxy zinc rich penetrating primer finished with polyurethane base paint with 45 micron coat in Black and golden colour as approved of Premium make shall deemed to be included in the unit quoated Rate. (ii) PCC for foundation required shall be measured and paid seperately under relevant item of schedule,How ever Nuts bolts washers of suitable size as ordered by OEM for planting pole in foundation shall deemed to be included in the unit rate quoated.
Supply and fixing, Outdoor, Pole Mounted, Energy saving, long life aesthetically designed die-cast aluminium landscape luminaire with high power 50 Wattage system LED as light source, 240 Volts , Make- Jaquar Cat No-OGL-BLK-SLERALDCD050WWT0 or Equivalent in crompton, Philips Powered by an integral electronic driver with output short circuit protection, surge protection & other safety tests. Elegantly designed spun aluminum housing and heat sink for efficient thermal management, sturdiness and excellent corrosion resistance. Lens- Heat resistant toughened bell shaped Transparent acrylic diffuser, Powder coated black after phosphochromate treatment. Ingress Protection (IP Rating) IP65, complete light fitting including taking down existing unserviceable complete all as specified and as directed Note- PCC for foundation required shall be measured and paid seperately under relevant item of schedule,How ever Nuts bolts washers of suitable size for embedding fitting in foundation shall deemed to be included in the unit rate quoated.
Supply and fixing LED Post-top lighting Luminaire (400mm Dia), 50 Watt system LED as light source, 240 Volts. Make Antra (ANT-8001) or Equivalent in Jaquar Powered by an integral electronic driver with output short circuit protection, surge protection & other safety tests elegantly designed die-cast aluminium housing and high grade aluminum heat sink for efficient thermal management, studiness and excellent corrosion resistance. 2 nos die-cast aluminium arms provided to support the housing. Powder coated black after phosphochromate treatment fitting complete all as specified and as directed. Note- PCC for foundation required shall be measured and paid seperately under relevant item of schedule,How ever Nuts bolts washers of suitable size for embedding fitting in foundation shall deemed to be included in the unit rate quoated.
Supply and fixing Landscape architectural outdoor lighting, LED Bollard Circular Disc 10W Warm White, Die cast aluminium housing Opal diffuser with in-built LED , 140 V - 270 V AC, Ingress Protection (IP Rating) IP65, typically giving off light from the sides, suitable to illuminate walkways, steps or pathways. of Make-Orient, Philips or Jaquar complete all as specified and as directed. Note- PCC for foundation required shall be measured and paid seperately under relevant item of schedule,How ever Nuts bolts washers of suitable size for embedding fitting in foundation shall deemed to be included in the unit rate quoated.
Supply and fixing High Efficient , Roadway ( street) Lighting Luminaire, LED 90 Wattage system (Top Opening 1-3W LED 100Lm/W) as light source, Powered by an integral electronic driver with output short circuit protection, surge protection & other safety tests, with aluminium pressure die-cast housing, toughened glass in the front and peanut lens for batwing light distribution,higher spacing between poles and maintenance-free system fitting of Make-Orient, Philips or Jaquar (OSL-GRY-LSRT015090XW) complete all as specified and as directed.
Supply and fixing High Efficient , Roadway ( street) Lighting Luminaire, LED 70 Wattage system as light source, Powered by an integral electronic driver with output short circuit protection, surge protection & other safety tests, with aluminium pressure die-cast housing, toughened glass in the front and peanut lens for batwing light distribution,higher spacing between poles and maintenance-free system fitting of Make-Orient, Philips or Jaquar (OSL-GRY-LSRT015070XW) complete all as specified and as directed.
Supply and fixing Floodlight luminaire LED 100 Watt as light source, Powered by an integral electronic driver with output short circuit protection, surge protection & other safety tests, with system efficacy of 120 lumens / watt and option of multiple wattages in both wide and narrow beam options with PDC housing,high impact resistance (IK07) glass cover fitting complete of Make-Orient, Philips (BVP282 LED120 CW FG SY5WB 100W SPD V1) or Jaquar complete all as specified and as directed.
Supply and fixing Floodlight luminaire LED 150 Watt as light source, Powered by an integral electronic driver with output short circuit protection, surge protection & other safety tests, with system efficacy of 120 lumens / watt and option of multiple wattages in both wide and narrow beam options with PDC housing,high impact resistance (IK07) glass cover fitting complete of Make-Orient, Philips ( BVP283 LED181 CW FG SY5NB 150W SPD V1 ) or Jaquar complete all as specified and as directed.
Supply and fixing Floodlight luminaire LED 200 Watt as light source, Powered by an integral electronic driver with output short circuit protection, surge protection & other safety tests, with system efficacy of 120 lumens / watt and option of multiple wattages in both wide and narrow beam options with PDC housing,high impact resistance (IK07) glass cover fitting complete of Make-Orient, Philips (BVP283 LED240 CW FG SY5NB 200W SPD V1) or Jaquar complete all as specified and as directed.
Supply and fixing as in replacement LED Post-top Lantern luminaire IP65 Rated Power 30 Watt elegantly designed spun aluminium and high grade aluminium heat sink for efficient thermal management, sturdiness and excelent corrosion resistance. MS base provided to support the housing. Powder coated black after phosphocromate treatment Make - Jaquar Cat No- OGL-BLK-PTAURORCD030WWT0 or Equivalent in Philips, Crompton
Supply and fixing as in replacement 25 mm threaded, 25 mm Height foam nozzle brass with chrome plating, (Make-Antra (ANT-535), Power as per Pump pressure flow complete all as specified and as directed
Supply and fixing as in replacement 25 mm threaded, 155 mm Height cascade jet nozzle brass with chrome plating, (Make-Antra (ANT-536), Power as per Pump pressure flow complete all as specified and as directed
Supply and fixing as in replacement under water light surface , Make-Antra (ANT-504) 3Wx12 - LED 36 Watt RGB outer Depth-25MM, Dia -125 MM, including driver and controller complete all as specified and as directed
Supply and fixing as in replacement spot fountain stand light, (Make-Antra (ANT-520) 3x6 - LED 18 Watt RGB outer Dia 110MM, Back Dia- 85 MM including driver and controller complete all as specified and as directed
Supplied and fixed as in repairs analog time switches Programmed via captive segmentPower supply: 230 V~ 50/60 Hz 3-position override switch "ON-AUTO-OFF" on frontpanel Manual changeover to summer/winter time, 1 segment = 15 minutes , Accuracy: ± 5 minutes, Vertical Dial N/O Contact - with 100 h working Reserve -Minimum switchingtime: 15 minutes, complete all as specified and directed.
S&F in repair power contactor 40 A 3 NO contactor, with 230 V~ coil and handle complete all as specified and directed. (Make : ABB / Legrand/L&T)
S&F in repair power contactor 63 A 3 NO contactor, with 230 V~ coil and handle complete all as specified and directed. (Make : ABB / Legrand/L&T)
Supply and fixing as in repairs MCCB TPN 63 Amps 25 KA breaking capacity, Ics=100%Icu, Make Legrand Cat No-4200 53 complete all as specified and directed
Material and labour for cable route marker made of Pre-cast cement concrete block masonry Type C1 1:3:6 (20mm graded aggregrate) with solid blocks, exc. 10 cm in width and setting in cement concrete mortar 1:6, including embosing DANGER/ LT CABLE / MES on cable route marker and properly painting with approved colour, size of cable route marker 900x300x100mm complete buried in ground for a depth of 45 cm & necessary earth work all as specified and as directed
Supply and laying across road crossing reinforced concrete pipes, class NP2, laid and jointed complete with collars of size 250 mm complete all as specified and as directed
Supply and laying across road crossing reinforced concrete pipes, class NP2, laid and jointed complete with collars of size 300 mm complete all as specified and as directed
Material and Labour Soling (or sub base) 150 mm spread thickness with broken boulders or quarried stone, inter stices filled, surface formed and rolled and consolidated to required gradient and camber complete all as specified and directed.
Supply & laying LT Aluminium Conductor Power Cables, Stranded Conductor, XLPE Insulated, Cores Laid Up, PVC Innersheathed, Armoured galvanised steel strip, Extruded PVC Type ST2 Outer Sheathed, 1100 V Grade as per IS 7098 (Part 1) 1988 with upto Date Amendments. cross-sectional area 400 Sqmm 3½ Core, passing in HDPE Pipe laid in trenches/ fixing on surface of Wall in cable tray securing with GI Cable clamps including Brass Cable Glands at termination end points Mild Steel Flat Iron Clampsof adequate size, etc. and Testing complete all as specified and as directed. NOTE : (i) Earthworks, cable protection Pipe, Cable Tray will be measured and paid under appropriate Items. (ii) Steel cable glands of adequate size , aluminium cable socket/ lugs ( bottle/ plate ) of required size at end termination in panel boards/ DBs , & Mild steel flat clamp of size for securing cable pipe along pole , on wall with nut, bolt, washers etc is deemed to be included in the item rate quoated.
Supply & laying LT Aluminium Conductor Power Cables, Stranded Conductor, XLPE Insulated, Cores Laid Up, PVC Innersheathed, Armoured galvanised steel strip, Extruded PVC Type ST2 Outer Sheathed, 1100 V Grade as per IS 7098 (Part 1) 1988 with upto Date Amendments. cross-sectional area 300 Sqmm 3½ Core, passing in HDPE Pipe laid in trenches/ fixing on surface of Wall in cable tray securing with GI Cable clamps including Brass Cable Glands at termination end points Mild Steel Flat Iron Clampsof adequate size, etc. and Testing complete all as specified and as directed. NOTE : (i) Earthworks, cable protection Pipe, Cable Tray will be measured and paid under appropriate Items. (ii) Steel cable glands of adequate size , aluminium cable socket/ lugs ( bottle/ plate ) of required size at end termination in panel boards/ DBs , & Mild steel flat clamp of size for securing cable pipe along pole , on wall with nut, bolt, washers etc is deemed to be included in the item rate quoated.
Supply & laying LT Aluminium Conductor Power Cables, Stranded Conductor, XLPE Insulated, Cores Laid Up, PVC Innersheathed, Armoured galvanised steel strip, Extruded PVC Type ST2 Outer Sheathed, 1100 V Grade as per IS 7098 (Part 1) 1988 with upto Date Amendments. cross-sectional area 150 Sqmm 3½ Core, passing in HDPE Pipe laid in trenches/ fixing on surface of Wall in cable tray securing with GI Cable clamps including Brass Cable Glands at termination end points Mild Steel Flat Iron Clampsof adequate size, etc. and Testing complete all as specified and as directed. NOTE : (i) Earthworks, cable protection Pipe, Cable Tray will be measured and paid under appropriate Items. (ii) Steel cable glands of adequate size , aluminium cable socket/ lugs ( bottle/ plate ) of required size at end termination in panel boards/ DBs , & Mild steel flat clamp of size for securing cable pipe along pole , on wall with nut, bolt, washers etc is deemed to be included in the item rate quoated.
Supply & laying LT Aluminium Conductor Power Cables, Stranded Conductor, XLPE Insulated, Cores Laid Up, PVC Innersheathed, Armoured galvanised steel strip, Extruded PVC Type ST2 Outer Sheathed, 1100 V Grade as per IS 7098 (Part 1) 1988 with upto Date Amendments. cross-sectional area 120 Sqmm 3½ Core, passing in HDPE Pipe laid in trenches/ fixing on surface of Wall in cable tray securing with GI Cable clamps including Brass Cable Glands at termination end points Mild Steel Flat Iron Clampsof adequate size, etc. and Testing complete all as specified and as directed. NOTE (i) Earthworks, cable protection Pipe, Cable Tray will be measured and paid under appropriate Items. (ii) Steel cable glands of adequate size , aluminium cable socket/ lugs ( bottle/ plate ) of required size at end termination in panel boards/ DBs , & Mild steel flat clamp of size for securing cable pipe along pole , on wall with nut, bolt, washers etc is deemed to be included in the item rate quoated.
Supply & laying LT Aluminium Conductor Power Cables, Stranded Conductor, XLPE Insulated, Cores Laid Up, PVC Innersheathed, Armoured galvanised steel strip, Extruded PVC Type ST2 Outer Sheathed, 1100 V Grade as per IS 7098 (Part 1) 1988 with upto Date Amendments. cross-sectional area 95 Sqmm 3½ Core, passing in HDPE Pipe laid in trenches/ fixing on surface of Wall in cable tray securing with GI Cable clamps including Brass Cable Glands at termination end points Mild Steel Flat Iron Clampsof adequate size, etc. and Testing complete all as specified and as directed. NOTE : (i) Earthworks, cable protection Pipe, Cable Tray will be measured and paid under appropriate Items. (ii) Steel cable glands of adequate size , aluminium cable socket/ lugs ( bottle/ plate ) of required size at end termination in panel boards/ DBs , & Mild steel flat clamp of size for securing cable pipe along pole , on wall with nut, bolt, washers etc is deemed to be included in the item rate quoated.
Supply & laying LT Aluminium Conductor Power Cables, Stranded Conductor, XLPE Insulated, Cores Laid Up, PVC Innersheathed, Armoured galvanised steel strip, Extruded PVC Type ST2 Outer Sheathed, 1100 V Grade as per IS 7098 (Part 1) 1988 with upto Date Amendments. cross-sectional area 70 Sqmm 3½ Core, passing in HDPE Pipe laid in trenches/ fixing on surface of Wall in cable tray securing with GI Cable clamps including Brass Cable Glands at termination end points Mild Steel Flat Iron Clampsof adequate size, etc. and Testing complete all as specified and as directed. NOTE : (i) Earthworks, cable protection Pipe, Cable Tray will be measured and paid under appropriate Items. (ii) Steel cable glands of adequate size , aluminium cable socket/ lugs ( bottle/ plate ) of required size at end termination in panel boards/ DBs , & Mild steel flat clamp of size for securing cable pipe along pole , on wall with nut, bolt, washers etc is deemed to be included in the item rate quoated.
Supply & laying LT Aluminium Conductor Power Cables, Stranded Conductor, XLPE Insulated, Cores Laid Up, PVC Innersheathed, Armoured galvanised steel strip, Extruded PVC Type ST2 Outer Sheathed, 1100 V Grade as per IS 7098 (Part 1) 1988 with upto Date Amendments. cross-sectional area 50 Sqmm 3½ Core, passing in HDPE Pipe laid in trenches/ fixing on surface of Wall in cable tray securing with GI Cable clamps including Brass Cable Glands at termination end points Mild Steel Flat Iron Clampsof adequate size, etc. and Testing complete all as specified and as directed. NOTE : (i) Earthworks, cable protection Pipe, Cable Tray will be measured and paid under appropriate Items. (ii) Steel cable glands of adequate size , aluminium cable socket/ lugs ( bottle/ plate ) of required size at end termination in panel boards/ DBs , & Mild steel flat clamp of size for securing cable pipe along pole , on wall with nut, bolt, washers etc is deemed to be included in the item rate quoated.
Supply & laying LT Aluminium Conductor Power Cables, Stranded Conductor, XLPE Insulated, Cores Laid Up, PVC Innersheathed, Armoured galvanised steel strip, Extruded PVC Type ST2 Outer Sheathed, 1100 V Grade as per IS 7098 (Part 1) 1988 with upto Date Amendments. cross-sectional area 35 Sqmm 3½ Core, passing in HDPE Pipe laid in trenches/ fixing on surface of Wall in cable tray securing with GI Cable clamps including Brass Cable Glands at termination end points Mild Steel Flat Iron Clampsof adequate size, etc. and Testing complete all as specified and as directed. NOTE : (i) Earthworks, cable protection Pipe, Cable Tray will be measured and paid under appropriate Items. (ii) Steel cable glands of adequate size , aluminium cable socket/ lugs ( bottle/ plate ) of required size at end termination in panel boards/ DBs , & Mild steel flat clamp of size for securing cable pipe along pole , on wall with nut, bolt, washers etc is deemed to be included in the item rate quoated.
Supply & laying LT Aluminium Conductor Power Cables, Stranded Conductor, XLPE Insulated, Cores Laid Up, PVC Innersheathed, Armoured galvanised steel strip, Extruded PVC Type ST2 Outer Sheathed, 1100 V Grade as per IS 7098 (Part 1) 1988 with upto Date Amendments. cross-sectional area 25 Sqmm 4 Core, passing in HDPE Pipe laid in trenches/ fixing on surface of Wall in cable tray securing with GI Cable clamps including Brass Cable Glands at termination end points Mild Steel Flat Iron Clampsof adequate size, etc. and Testing complete all as specified and as directed. NOTE : (i) Earthworks, cable protection Pipe, Cable Tray will be measured and paid under appropriate Items. (ii) Steel cable glands of adequate size , aluminium cable socket/ lugs ( bottle/ plate ) of required size at end termination in panel boards/ DBs , & Mild steel flat clamp of size for securing cable pipe along pole , on wall with nut, bolt, washers etc is deemed to be included in the item rate quoated.
Supply & laying LT Aluminium Conductor Power Cables, Stranded Conductor, XLPE Insulated, Cores Laid Up, PVC Innersheathed, Armoured galvanised steel strip, Extruded PVC Type ST2 Outer Sheathed, 1100 V Grade as per IS 7098 (Part 1) 1988 with upto Date Amendments. cross-sectional area 16 Sqmm 4 Core, passing in HDPE Pipe laid in trenches/ fixing on surface of Wall in cable tray securing with GI Cable clamps including Brass Cable Glands at termination end points Mild Steel Flat Iron Clampsof adequate size, etc. and Testing complete all as specified and as directed. NOTE : (i) Earthworks, cable protection Pipe, Cable Tray will be measured and paid under appropriate Items. (ii) Steel cable glands of adequate size , aluminium cable socket/ lugs ( bottle/ plate ) of required size at end termination in panel boards/ DBs , & Mild steel flat clamp of size for securing cable pipe along pole , on wall with nut, bolt, washers etc is deemed to be included in the item rate quoated.
Supply & laying LT Aluminium Conductor Power Cables, Stranded Conductor, XLPE Insulated, Cores Laid Up, PVC Innersheathed, Armoured galvanised steel strip, Extruded PVC Type ST2 Outer Sheathed, 1100 V Grade as per IS 7098 (Part 1) 1988 with upto Date Amendments. cross-sectional area 10 Sqmm 4 Core, passing in HDPE Pipe laid in trenches/ fixing on surface of Wall in cable tray securing with GI Cable clamps including Brass Cable Glands at termination end points Mild Steel Flat Iron Clampsof adequate size, etc. and Testing complete all as specified and as directed. NOTE : (i) Earthworks, cable protection Pipe, Cable Tray will be measured and paid under appropriate Items. (ii) Steel cable glands of adequate size , aluminium cable socket/ lugs ( bottle/ plate ) of required size at end termination in panel boards/ DBs , & Mild steel flat clamp of size for securing cable pipe along pole , on wall with nut, bolt, washers etc is deemed to be included in the item rate quoated.
Laying only LT UG Cable of any description and size (serviceable Cable obtained from Item No. 23 here-in-after), laid in trenches / on surface of wall / along with pole in and passing through cable protection cable protection Pipe & connecting to End termination Point, switch fuse unit and testing, complete all as specified and as directed. NOTE : (i) Earthworks, cable protection Pipe, Cable Tray will be measured and paid under appropriate Items. (ii) Steel cable glands of adequate size , aluminium cable socket/ lugs ( bottle/ plate ) of required size at end termination in panel boards/ DBs , & Mild steel flat clamp of size for securing cable pipe along pole , on wall with nut, bolt, washers etc is deemed to be included in the item rate quoated.
Taking down/out unserviceable UG Cables of any Cross Sectional Area and connections and joints including pipes, bricks, etc of any description laid in trenches or fixed with walls / poles, segreating serviceable Bricks/Precast covers, pipes, cables etc, and keep in safe custody for reuse, or carrying to store complete all as specified and as directed. Note 1 : Earthwork will be measured and paid under appropriate Items. Note 2: Earthworks, cable protection Pipe, Cable Tray will be measured and paid under appropriate Items. (ii) Steel cable glands of adequate size , aluminium cable socket/ lugs ( bottle/ plate ) of required size at end termination in panel boards/ DBs , & Mild steel flat clamp of size for securing cable pipe along pole , on wall with nut, bolt, washers etc is deemed to be included in the item rate quoated.
Supply and laying corrosion- resistant, non-porous, high-density polyethylene (HDPE) Pipe (Material PE-80) of Size 50 mm, (1.5") , Pressure Rating (PN): 6 kg/cm², laid in trenches along with accessories complete for electrical usage as in cable protection pipe to protect cable from external physical damage all as specified and as directed.
Supply and laying corrosion- resistant, non-porous, high-density polyethylene (HDPE) Pipe (Material PE-80) of Size 63 mm, (2 "), Pressure Rating (PN): 6 kg/cm², wall thickness not less than 3.6mm laid in trenches along with accessories complete for electrical usage as in cable protection pipe to protect cable from external physical damage all as specified and as directed. Make Supreme or equivalent
Supply and laying corrosion- resistant, non-porous, high-density polyethylene (HDPE) Pipe (Material PE-80),of Size 75 mm (2.5 "), Pressure Rating (PN): 6 kg/cm², wall thickness not less than 3.6mm laid in trenches along with accessories complete for electrical usage as in cable protection pipe to protect cable from external physical damage all as specified and as directed.
Supply and laying corrosion- resistant, non-porous, high-density polyethylene (HDPE) Pipe (Material PE-80) of Size 90 mm, (3 "), Pressure Rating (PN): 6 kg/cm², wall thickness not less than 3.6mm laid in trenches along with accessories complete for electrical usage as in cable protection pipe to protect cable from external physical damage all as specified and as directed.
Supply and laying corrosion- resistant, non-porous, high-density polyethylene (HDPE) Pipe, (Material PE-80), of Size 110 mm (4 "), Pressure Rating (PN): 6 kg/cm², wall thickness not less than 3.6mm laid in trenches along with accessories complete for electrical usage as in cable protection pipe to protect cable from external physical damage all as specified and as directed.
Supply and fixing Medium duty SS 304 CABLE PERFORATED TRAYS, rust proof, in standard length of 2.5 Mtr, thickness - 3.0 mm, and height of tray 50mm complete with side SS couplers plates to connect cable trays with each other, SS couplers cable tray bends, and supporting accessories of GI (Galvanized Iron) Threaded Rods, Hole Fasteners, with nuts, bolts, washers etc for fixing cable tray on walls or hanging with ceilings all as specified and as directed complete width of
Cable Tray 150mm
Cable Tray 200mm
Cable Tray 250 mm
Cable Tray 300mm
Supply and fixing LT,1100 Volt grade, PVC Heat shrinkable straight through joint kit, 3.5/ 4 Core Make M- Seal suitable for cable size
Cable 25 - 50 Sqmm
Cable 70 - 120 Sqmm
Cable 150 - 185 Sqmm
Cable size 240 -300 Sqmm
Supply and fixing as in replacement Aluminium sector lugs - Short Barrel/ suitable for Make Dowell or Equivalent cable size
25 /16 Sqmm size 4 core
35 Sqmm size 3½ core
50 Sqmm size 3½ core
70 Sqmm size 3½ core
95 Sqmm size 3½ core
120 Sqmm size 3½ core
150 Sqmm size 3½ core
185 Sqmm size 3½ core
240 Sqmm size 3½ core
300 Sqmm size 3½ core
400 Sqmm size 3½ core
Material and labour for Repairing cable ducts inside substation building involving following Items:- (i) Setting aside serviceable cable duct covers PCC/ Chequered Plates of any size,and stacking at proper place for reuse. (ii) Taking out serviceable / unserviceable LT/ HT Cables of any size after disconnecting end termination joints for repair/ plaster of cable ducts, removing unwanted sand/ stone, debris accumulated inside cable ducts, to a distance not exc 50.00 Metre away and depositing at place where directed (ii) Connecting end termination of cables to restore power supply after cutting/ removing burnt cable ends, providing cable sockets of size ordered and placing properly PCC/ Chequered Plates on cable duct. Note- (i) Taking out, relaying of cable, Aluminium cable lugs (socket), repair to cable ducts shall be measured and paid under respective item of schedule (ii) Labour component involved for setting aside and placing cable duct covers, removing unwanted debris from cable duct is deemed to be included in the unit rate quoated.
Supplied and fixed, Category 25 KA, Rated Current (A) - 63 /100 Amps , 4 Pole MCCB , Type -DPX³-160 of Make- Legrand or equivalent as per existing fixed in panel board at site with thermal magnetic protection unit, O/L & S/C protection, Ics=100%Icu, complete all as specified and as directed
Supplied and fixed, Category 25 KA, Rated Current (A) - 125 Amps , 4 Pole MCCB , Type -DPX³-160 of Make- Legrand or equivalent as per existing fixed in panel board at site with thermal magnetic protection unit, O/L & S/C protection, Ics=100%Icu, complete all as specified and as directed
Supplied and fixed, Category 25 KA, Rated Current (A) - 160 Amps , 4 Pole MCCB , Type -DPX³-160 of Make- Legrand or equivalent as per existing fixed in panel board at site with thermal magnetic protection unit, O/L & S/C protection, Ics=100%Icu, complete all as specified and as directed
Supplied and fixed, Category 36 KA, Rated Current (A) - 160 Amps , 4 Pole MCCB , Type DPX³ 160 of Make- Legrand or equivalent as per existing fixed in panel board at site with thermal magnetic protection unit, O/L & S/C protection, Ics=100%Icu, complete all as specified and as directed
Supplied and fixed, Category 36 KA, Rated Current (A) - 200 Amps , 4 Pole MCCB , Type -DPX³250 of Make- Legrand or equivalent as per existing fixed in panel board at site with thermal magnetic protection unit, O/L & S/C protection, Ics=100%Icu, complete all as specified and as directed
Supplied and fixed, Category 36 KA, Rated Current (A) - 250 Amps , 4 Pole MCCB , Type -DPX³-250 of Make- Legrand or equivalent as per existing fixed in panel board at site with thermal magnetic protection unit, O/L & S/C protection, Ics=100%Icu, complete all as specified and as directed
Supplied and fixed, Category 36 KA, Rated Current (A) - 320 Amps , 4 Pole MCCB , Type -DPX³ 630 of Make- Legrand or equivalent as per existing fixed in panel board at site with thermal magnetic protection unit, O/L & S/C protection, Ics=100%Icu, complete all as specified and as directed
Supplied and fixed, Category 36 KA, Rated Current (A) -400 Amps , 4 Pole MCCB , Type -DPX³ 630 of Make- Legrand or equivalent as per existing fixed in panel board at site with thermal magnetic protection unit, O/L & S/C protection, Ics=100%Icu, complete all as specified and as directed
Supplied and fixed, Category 50 KA, Rated Current (A) -200 Amps , 4 Pole MCCB , Type -DPX³ 250 of Make- Legrand or equivalent as per existing fixed in panel board at site with thermal magnetic protection unit, O/L & S/C protection, Ics=100%Icu, complete all as specified and as directed
Supplied and fixed, Category 50 KA, Rated Current (A) - 250 Amps , 4 Pole MCCB , Type -DPX³ 250 of Make- Legrand or equivalent as per existing fixed in panel board at site with thermal magnetic protection unit, O/L & S/C protection, Ics=100%Icu, complete all as specified and as directed
Supplied and fixed, Category 50 KA, Rated Current (A) - 320 Amps , 4 Pole MCCB , Type -DPX³ 630 of Make- Legrand or equivalent as per existing fixed in panel board at site with thermal magnetic protection unit, O/L & S/C protection, Ics=100%Icu, complete all as specified and as directed
Supplied and fixed, Category 50 KA, Rated Current (A) - 400 Amps , 4 Pole MCCB , Type -DPX³ 630 of Make- Legrand or equivalent as per existing fixed in panel board at site with thermal magnetic protection unit, O/L & S/C protection, Ics=100%Icu, complete all as specified and as directed
Supply and fixing On Load Changeover Switche, Open Execution, 400 Amps, Front operated 4 Pole 415V, 50Hz. Conforms to IEC 947-3, EN - 60947-3 AC-23A of Make- HPL or equivalent as per existing fixed in panel board at site complete all as specified and as directed
Supply and fixing On Load Changeover Switche, Open Execution, 320 Amps, Front operated 4 Pole 415V, 50Hz. Conforms to IEC 947-3, EN - 60947-3 AC-23A of Make- HPL or equivalent as per existing fixed in panel board at site complete all as specified and as directed
Supply and fixing On Load Changeover Switche, Open Execution, 250 Amps, Front operated 4 Pole 415V, 50Hz. Conforms to IEC 947-3, EN - 60947-3 AC-23A of Make- HPL or equivalent as per existing fixed in panel board at site complete all as specified and as directed
Material and labour for detecting the presence, tracing the path of underground utilities like pipes and cables to prevent accidental damage and approximate location of buried services in advance of undertaking excavation works and locating damaged, injured LT/ HT cable continious power flow supply with underground Power Cable Fault Locator machine complete all as specified and as directed. Note- (i) The contractor shall arrange cable fault detector machine within time bound period of 12 Hours to tack fault of underground Pipe/ cable. Penalty of Rs 2000. will be raised for every one hour late and amount of late hours will be deducted from the workdone. (ii) Eartwork, for tracing out cable foult and refilling of excavated soil after repair of cable, making good disturbed ground shall deemed to be included in the unit rate quoated. However cost of straight through joint will be measured and paid seperately under respective Item of schedule. (iii) Numbers of each fault detected shall be measured and paid seperately.
Supply and fixing 3 Line LED display, Cl.0.5s, Multi function Panel Mounted in 96 x 96 Sq. mm Flush mounted case energy meter, 3P 4W, 5A configurable with RS 485 Communication port Make- HPL Cat No PAMEBRITMF25 or Equivalent in L&T, Legrand complete all as specified and as directed.
Taking down cement plaster of any description in any position including racking out joints making key scrubbing down with water etc. and removal of debris out side MD land. Complete all as specified and directed.
M&L 10 mm thick rendering in CM 1:3 on fair faces of concrete surfaces of ceiling on plastered ceiling surfaces; surfaces finished even and smooth with out using extra cement complete all as specified and directed.
M&L 15mm thick plastering in CM 1:6, on fair faces of brick work or concrete surfaces and provn of 3mm thick wall care putty on plastered surfaces of wall; surfaces finished even and smooth with out using extra cement complete all as specified and directed.
Demolition of brick work built in CM incl. taking out roots vegetation if any at any position and removal to out side MD land. Complete all as specified and directed.
M&L for brick work with sub class 'B' bricks straight or curved on plan exc. 6m mean radius built in CM(1:6) complete all as specified and directed.
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.39 MB
Tenderdocus.pdf
Tender Documents • 1.12 MB
BOQ_836230.xls
BOQ • 1.67 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .