| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹20.9 LAccepted-AOC | L1 | Accepted-AOC Being lowest | |
| 2 | L2₹23.6 L+₹2.6 L (12.6%)Rejected-Finance A 47D RAM DUTT ENCLAVE UTTAM NAGAR NEW DELHI 110059 | WEST | DELHI | 110059 | L2 | Rejected-Finance Not being lowest |
Tender Value
₹27.3 L
EMD Value
₹54,640
Closing Date
5 Mar 2021, 6:00 pmClosed
CWE (AF) Gurgaon
HQ CWE (AF) Gurgaon, Old Palam Road, Delhi Cantt-110010
PROVN OF ALUMINIUM COMPOSITE CLADDING IN BLDG NO P122 PROVN OF SHED AT CERTAIN LOCATIONS PROVN OF TILLING INTERLOCKING TILES AT CERTAIN LOCATIONS PROVN OF KITCHEN CABINET AT CERTAIN MARRIED ACCN AND PROVN OF REVERSE OSMOSIS PLANT PURIFIER 500LTR ETC
2021_MES_419392_1
CA NO CWE/GGN/G-47/2020-21
Open Tender
Civil Works
Item Rate
180 days
Gurgaon
As per NIT
9 documents required · 9 mandatory
₹500
GE (AF) Gurgaon
₹54,640
Yes
7 Apr 2021
5 Feb 2021
8 Mar 2021
5 Feb 2021
5 Mar 2021
19 Feb 2021
Amount
Designing providing and fixing 3mm thick Aluminium Composite Cladding over RCC/Brick surfaces either segmental/straight in plan wherever specified with extruded aluminium U sections, angle, cleats, weather sealants, backer rods of required size stainless steel screws, rivets, brackets, drilling and fixing the cladding to either masonry or reinforced cement concrete as the case may be manufacturer's specifications, complete the work in all respect including all necessary accessories. At all soffits aluminium cladding shall be bend 90 degree and joints at corner or edges will not be acceptable. On horizontal surface, the size of sheet should be maximum available of size complete all as per manufacturer's specifications and as directed.
Excavation in post holes (or similar holes) in hard /dense soil each n exe 0.5 cu.m, gettting out, returning, filling in and ramming earth or broken rubble mixed with earth around , in layers not exeeding 25cm, watering, and removing surplus soil to a distance n exe 50 m and making good surface complete all as specified and as directed.
M&L for plain cement concrete 1:4:8 type D-2, with using 40 mm grades stone aggregates as in foundations and mass concrete etc complete all as specified and as directed
M&L for providing cement concrete (1:2:4) type B1 (using 20mm graded crushed stone aggregates) as in lintels upto 1.5m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, kerbs not provided for in Item 04028, water troughs and the like including weathering, slightly rounded or chamfered angles and throating, etc including necessary formwork complete all as specified and directed by Engineer-in-Charge.
M&L for brick work with sub class 'B' brick, straight or curved on plan exc 6.0 mtr mean radius built in CM 1:6 etc complete all as specified and as directed
M&L for rendering 15 mm thick in CM (1:4) on fair faces of brick work or concrete surface finished even and fair mixed with water proofing compound as per manufacture instruction etc complete all as specified and as directed Notes : WPC shall be measured and paid seperately
Supply only WPC
S&F rolled sections, MS Angles, MS tubular Structures, MS Channels, Tee, etc. (Fe 410-W Gde-E-250 quality-A) as in main and cross beams, hip and jack rafters, purlins , posts,trusses (framed or unframed) structures where connected to common rafter and running rails and guides for sliding doors, fixed with angles clleats or other connecting plates all as specified.
S&F pre-painted galvatume aluminium zinc coating GI based corrugated steel 0.50 mm thick of any colour as directed by GE having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified and directed by Engineer-in Charge
M&L for preparation of new surface of any description and applying two coats of synthetic enamelled paint over a coat of red oxide primer on steel surface over 10cm width or girth complete all as specifed.
Material and labour for preparation of newly plastered surfaces of walls and applying two coats of cement base paint to achieve uniform and smooth surface having no sign of brush marks complete all as specified and as directed.
Surface excavation n.exc (not exceeding) 30 cm deep and averaging 15cm deep and getting out in soft/loose soil complete all as specified and as directed.
M&L for hard core of gauge not exc 63 mm, deposited, spread, and levelled in layers not exc 15 cm thick, watered and rammed to a true surface etc complete all as specified and as directed
M&L for 75 mm thick cement concrete (1:4:8) type D-2 with using 40 mm graded stone aggregates) as in sub base of flooing etc complete all as specified and as directed
M&L for screed bed or bedding layer of mortar 15 mm thick in CM (1:4) for laying floor finishes complete all as specified and as directed
M&L for chequered cement concrete tiles 20cm x20cm x 25mm thick, set, jointed and pointed with white cement and pigment in neat cement slurry in floor complete all as specified and as directed.
Demolition of stone slabs and tiles of any description or thickness in floors, apron etc complete all as specified and directed by Engineer-in-charge.
M&L first quality Vitrified ceramic tiles light shade,10 mm thick (square/rectangular) polished, area of each tile exceeding 0.42 sqm but n exc 1.0 Sqm, laid in floors with neat cement slurry @ 3.00 Kg/square over and including 15 mm thick screed bed in cement mortar 1:6, including pointing in white or coloured cement to match the shade of tiles, complete all as specified and directed.
complete all as per item No 18 but on vertical surface as skirting over and incl 12 mm thick backing coat in CM 1:4 in lieu of screed bed.
M&L for joint free non skid skretch proof stain resistant coloured ceramic tile 600x600x7 to 9 mm thick in floor etc, set and jointed in neat cement slurry @ 3.00 Kg/square area over and including 15 mm thick screed bed in cement mortar 1:6, including pointing in white or coloured cement to match the shade of tiles, complete all as specified and directed.
M&L for 25 mm thick PCC (1:2:4) type B-0 using 12.50 mm graded stone aggregates as in flooring finished even & smooth without using extra cement, complete all as specified.
M&L for perforated particle board/ tiles12 mm for insulation and accoustic purposes, 60x60 cm in size,fixed with nails or with staple in ceiling/ timber frame complete all as specified.
S&F GI Frame work for seamless ceiling comprising of GI perimeter Channel 0.55 mm thick with two unequal flange of 20 and 30 mm and web of 27 mm fixed to surrounding mild steel frame work using nylon sleeve and screw at 450 mm centre to centre/ intermediate channel 0.9 mm thick having two equal flanges of 15 mm each and web of 45 mm suspended from soffit at approx 900 mm centre to centre with GI cleat and steel expansion fastener with and including ceiling section (n exc 1.20 m length) of 0.55 mm thickness having kurled web of 50 mm and flange of 26 mm each with lips of 10.50 mm fixed to intermediate channel with connecting clips across the intermediate channel at 457 mm centre to centre includng hanger 6 mm dia GI (upto 1200 mm length) adjusting level fixed to roof slab by means of ceiling cleat made out of GI flat 40x3 mm size 60 mm long and expansion hold fastener 12.50 mm dia 40 mm long complete all as specified.
S&F 500 litres capacity Rotational moulded polyethylene water storage tanks (Cylindrical vertical with closed top), ISI marked triple layer construction, hoisted & fixed in position including Ball valve, high pressure PTMT with epoxy coated aluminium rod and high density plastic ball, screwed for 20 mm bore GI pipe of having weight not less than 210 gms incl all fittings and gate valves with iron wheel head 20 mm size,complete in all respect as specified. Make: SIntex, Polycon, polywell or equivalent Approved makes.
complete all as per item No 24 here in before but 1000 ltr capacity tank.
S&F 18 mm/ 19 mm thick prelaminated particle board, interior grade, prelaminated both sides with decorative choice lamination for wooden and fixed with screws to timber frame as in cupboards, shutters, shelves, pelmet etc. including fixing 18 mm wide 6 mm thick beading of Ist class HW (Teak) all around, complete all as specified and as directed.
S&F Continuous (piano) hinges, mild steel, bright finish or electro galvanised, 30 mm wide flap (when open), complete all as specified and as directed.
S&F 100mm size extruded brass handles, fabricated type polished complete all as specified and as directed.
S & F plain fillets square, rectangular or triangular in section, 2nd class hardwood of sectional area exc 13 sqcm but n exc 25 sqcm, clean sawn, wrought finished secured with screws complete all as specified and as directed
S&F magnetic catcher 50mm long complete with plate fixed with screws complete all as specified and as directed.
M&L for 18-20mm thick granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, window-cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite over and including 15mm thick screed bed in CM (1:4) complete all as specified and as directed.
Dismantling floor hearth or wall tiling including cement mortar bedding (but not backing) removing serviceable tiles to store and rubbish off the permises complete all as specified and as directed
M&L first quality Vitrified ceramic tiles any shade,10 mm thick (square/rectangular) polished, area of each tile not exceeding 0.36 sqm, laid in floors, set jointed with neat cement slurry @ 3.00 Kg/square over and including 15 mm thick screed bed in cement mortar 1:4, including pointing in white or coloured cement to match the shade of tiles, complete all as specified and directed.
M&L for first quality coloured glazed ceramic tiles, fixed in pattern of different colour including border of size 300x 450 x 7mm thick as in vertical surfaces such as dado/skirting, set and jointed in neat cement slurry and pointed in white cement with pigment to match with shade of tiles laid on and including 10 mm thick rendering in cement mortar (1:3), complete all as specified and as directed. Note :- Pattern of the tiles shall be approved by GE at the time of execution.
Demolition of cement concrete of any description (un-reinforced) in ground floors and paving n exc. 15 cm thickness (below or above ground level) incl tile and removing rubbish outside Mil land, complete all as specified
Excavation in trenches, not exc 1.5 m wide and n exc 1.5 m in depth for foundation or for shaft, wells, cesspit, manholes, pier holes or laying of under ground cables etc and getting in soft/loose soil complete all as specified and directed .
Excavation in post holes (or similar holes) in soft/loose soil each n exe 0.5 cu.m, gettting out, returning, filling in and ramming earth or broken rubble mixed with earth around , in layers not exeeding 25cm, watering, and removing surplus soil to a distance n exe 50 m and making good surface complete all as specified and as directed.
M&L for providing Plain Cement concrete in 1:2:4 type B-2 using 40mm graded stone aggregates as in foundation and mass concrete complete all as specified.
M&L for machine pressed Precast interlocking paver block of any size and shape confirming to IS 15658-2006 of 80 mm thickness of M-40 grade with grey cement and pigments over 25 mm thick sand cushioning (sand to be measured and paid seperately) complete all as specified.
M&L for sand cushioning under floor, in foundation or in cable trenches incl watering and consolidation complete all as specifed and directed .
M&L for Plain cement concrete (1:2:4) type B-1, using 20 mm graded mechanically crushed stone aggregates as in roof kerb, mud stops,rounded or chamfered and finishing the surfaces even and smooth without using extra cement, complete all as specified
S&F 15mm bore dia of steel tubing of medium grade, ISI market with all fittings and fixed to wall or laid in floor etc complete all as specified
complete all as above item No 42 above but for 20 mm dia complete all as specified
complete all as above item No 42 above but for 25 mm dia complete all as specified
S&F bib taps, cast copper alloy, chromium plated, fancy type, screwed for 15 mm bore iron pipe or for brass ferrule complete all as specified.
S&F angle valve /stop valves, cast copper alloy, chromium plated, fancy type, screwed down, high pressure, screwed both ends for 15 mm bore iron pipe or for brass ferrule complete all as specified.
Returning, filling soil in including spreading, levelling, watering and well ramming in layers n. exc. 25 cm complete all as specified and directed .
Removing excavated soil to a distance n.exc 50 m and depositing where directed at a level n.exc. 1.5 m above the starting point complete all as specified and directed .
Supply and install Reverse Osmosis plant of out put capacity 500 ltrs per hours UV based including Raw water pump, dual media filter, Activated carbon filter, dozing system, micron filter,High pressure pump, RO membrane, RO pressure tube etc including capacity utilization 91-95%, input to RO plant with total dissolved solids < 1500 PPM and otput from RO plant with total dissolved solids < 50 PPM complete all as specified and directed by Engr-in-Charge with the following specification :- . 1. RAW WATER PUMP : To feed the Dual Media Filter at pressure more than 2.0 bar, which is min. operating pressure for filter. Horizontal type Centrifugal pump of capacity 1 HP, single phase, 230 volts, 50 Hz, MOC - CI type - 01 Nos. Make: CRI/Crompton/KSB/Kirlosker or equivalent in approved make. 2. DUAL MEDIA FILTER : To remove the total suspended solids, dirt , iron and reduce silt density index which can foul the membranes. The Vessel FRP, Seaflo or Equivalent made of dia 10" & height 54" with testing pressure 10 kg/cm2, Top opening with valve size ¾” - 01 Nos 3. ACTIVTED CARBON FILTER : To remove the total color, smell, odur, from the water. The Vessel made of FRP, Seaflo or Equilent made of dia 10" & height 54" with testing pressure 10 kg/cm2, Top opening with valve size ¾” - 01 Nos. 4. DOSING SYSTEM : To dose antiscalant chemical to protect the scaling formation on RO membranes. The MOC made of PP of capacity 6 LPH with Pressure: 7 Bar. - 01 Nos. Make: Idose or equivalent 5. MICRON FILTER : To remove the fine particles up to 05 microns and reduce silt density index levels to acceptable level. Cartridge Filter & Housing : The MOC of Housing made out of PP of Length 20” and Diameter 6” - 01 No. Cartridge. Make - Filtermation or equivalent . The Cartridge MOC of Polypropylenewith Length: 20” and Diameter : 4.5” - 01 Nos of Micron rating: 05 micron.
6. HIGH PRESSURE PUMP : To feed the Reverse Osmosis Membrane at pressure more than the osmotic pressure taking into consideration flux rate, flow and recovery. The high pressure pump vertical type multistage of capacity 1.5 HP, single phase, 230 volts, 50 Hz of made of Stainless Steel - 01 Nos. Make: Lubi Or Equivalent. 7 RO MEMBRANE : To remove the major part of TDS upto 98% by Reverse Osmosis Membranes arranged and designed to give adequate flow and recovery. The membrane Spiral Wounded type of dia 4 inch. & length 1 mtr - 02 Nos of Membranes with Salt Rejection per Membrane: 98-99%. including hydronotic U or Dow & system recovery 50-70%. 8. RO PRESSURE TUBE : To pack Reverse Osmosis Membranes and operate at high pressure up to 300 psi. The RO pressure tube made of FRP Composite with dia of Pressure Vessel 4.2 inch & length 2.3 mtr, No. Pressure Vessels - 04 Nos & No. of Membrane per Vessel - 02 Nos. Make: Sealfo or Equivalent. 9. ELECTRONIC PANAL : A control panel is provided as a safety measure for the pumps & other electrical items. The Complete Starters, Overload relays, and single-phase preventor for Pump and Push Buttons. 10. INSTRUMENTATION : (a) Flow Meter : To measure the online flow of water. (c) Low Pressure Switch : To protect RO pump from dry running. (e) High Pressure Switch : To protect RO pump from back pressure (f) Pressure Gauges : For calculate ^P for each unit in RO system. Rota Meter : Quantity : 3 Nos.( permit & reject line). Range : 1000 ltr per hour. Pressure Switch : Quantity : 2 No.(Low & High). Range : 0-450 psi. Make : Aster, India. Pressure Gauges : Quantity : 4 No. Range : 7 – 21 bar. Dail Size : 3 inches. Brand Seaflo or equivalent. 11. UV : (a) R.O PLANT UV Based 16w
S&F of gun metal gate valve (heavy duty) with iron wheel head screwed both ends for iron pipe of 25 mm dia bore complete all as specified and directed.
M&L for making Straight plain brass ferrules (or connecting screws) screwed both ends and fixed both ends with connectors of 25mm dia size complete all as specified and directed. Note: Cutting of hole in CI pipe without any damage to existing pipe line is deemed to included in quoted rate.
Supply, fixing, testing and commissioning of LT feeder pillar panel single door floor mounted and wall/pole mounted outdoor type, as per IP-55 grade, made out of MS sheet 3.15 mm thick of size 540x525x200mm with aluminium bus bar 250 Amps, 4 strip (3 phase) complete drilled, insulated with colour coded insulation tape, mounted on insulators etc with RYB indicator, panel should be dust proof, vermin proof, powder coated , locking should be screw type, mechanical type, inter locking with 100 Amps 16 KA MCCB four pole (adjustable type) for incomer cable, should have danger notice for 415 volts, AC, mounted on 50x50x6 mm angle iron frame having minimum 2 feet ground clearance duly embedded in and including PCC block (1:2:4) complete including termination of all incoming and outgoing cables with suitable size thimbles/lugs and glands etc and providing fixing arrangements including earthing lead fixing arrangement complete all as specified and directed. Note :- Installation, testing, commissioning and connecting of incoming and outgoing cable connection LT feeder pillar panel is included in rates quoted.
Supply , laying & testing for XLPE insulated, armoured, heavy duty electric cable with stranded aluminium conductor, 1100 volts grade, laid in trenches, sleeving through pipes or fixed on poles & walls or laid under floors including jointing with suitable size aluminium lugs complete of size 25 sqmm 4 core complete all as specified and directed.
M&L for wiring with and including multistranded copper conductor 1.5 Sqmm (nominal cross sectional area) single core, PVC insulated, unsheathed, FRLS grade cable, 1100 Volts grade, ISI marked with valid CML number drawn in and including medium grade PVC casing and capping double lock type 32mm in size, fire resistant, ISI marked including fittings and fixtures such as tee, bend, elbow, junction boxe, etc. including multistranded copper conductor 1.5 Sqmm (nominal cross sectional area) single core, PVC insulated, unsheathed, FRLS grade cable 1100 Volts grade, ISI marked with valid CML number as continuity earth wire and including min 1.6 mm thick pressed steel sunken concealed terminal box with 3mm thick industrial laminated sheet cover for mounting switches, sockets and fan regulators etc. complete all as specified and directed for the following :-
(a) One light/ fan point controlled by one way switch
(b) One 3 pin, 5 Amps, socket outlet on the same board controlled by another switch.
All as per items No 54 but with 2.5 Sqmm (nominal cross sectional area) single core, PVC insulated, unsheathed, FRLS grade cable, 1100 Volts grade, ISI marked with valid CML number drawn in and including medium grade PVC casing and capping double lock type 32mm in size, fire resistant, ISI marked including fittings and fixtures such as tee, bend, elbow, junction boxe etc. including multistranded copper conductor 2.5 Sqmm (nominal cross sectional area) single core, PVC insulated, unsheathed, FRLS grade cable 1100 Volts grade, ISI marked with valid CML number as continuity earth wire and including pressed steel sunken concealed terminal box thickness min 1.60mm with 3mm thick industrial laminated sheet cover for mounting switches, sockets and fan regulators etc. for one 3/5 pin, 15 Amps socket outlet point on independent board controlled by one 15 Amp switch complete all as specified and directed.
S&F, switch piano, flush button, single pole, one way, 5 Amps complete all as specified and directed
S&F, switch piano, flush button, single pole, one way 15 Amps complete all as specified and directed
S&F, socket outlet, 2 in 1, 3/5 pin, 5 Amps, flush type complete all as specified and directed
S&F, socket outlet, 2 in 1, 3/5 pin, 5/15 Amps flush type complete all as specified and directed
S&F for sheet metal distribution board, SPN, 4 way 240 Volt, double door, factory made and tested complete, protection class IP-42 suitable for mounting MCBs, isolator with 200 Amp tinned copper bus bar complete all as specified and directed
S&F miniature circuit breakers, type curve ‘B’ , 10 KA, SP 6 to 32 Amps complete all as specified and directed.
S&F for miniature circuit breakers, Single pole and neutral, type curve ‘C’ 10KA, 40 Amps, 230 Volts. complete all as specified and directed.
S&F for LED light fitting, batten type,4 feet long, housed in extruded from powder coated aluminium, 20 watt for soft diffuser lighting with and including lamp and connecting up complete with white PVC insulated and PVC sheathed round flexible twin core copper conductor cable of suitable size and testing on completion all as specified and directed. Make: As per C&S Cat No. LTTB4F20WLED/W of C&S or equivalent approved make.
M&L for Earthing complete with galvanised steel earth plate electrode 60x60cmx6mm thick, buried directly in ground (earth pit not less than 2.25 meters deep below ground level) with top edge of the plate not less than 1.5 meters below normal ground level, connected to galvanised earth lead wire 4.0 mm dia by means of bolts, nuts check nuts and washers of galvanised iron protection pipe light grade of 20mm dia and watering pipe medium grade of 15 mm dia and filled with alternate layer of charcoal and common salt, watering funnel with wire mesh, earth pit chamber and cover CI frame PCC 1:3:6 type C-2 all as specified directed and shown in electrical plate No 3 of SSR part -I of 2009 connecting to earthing test point all as specified and indicated including all earth work excavation in any type of strata, returning filling and disposal of surplus soil and testing on completion complete all as specified and as directed. Including testing complete Complete all as specified and directed by Engr-in-charge. Note: The quoted rate of earthing shall be deemed to include the cost of earth work, wire mesh, PCC pit, funnel, CI frame and 7.5 mtr long galvanised iron lead wire 4.0 mm dia and protection pipe of 20 mm bore light grade. Any variation in length shall be adjusted through deviation order based on SSR rates adjusted with quoted rates.
Supply and laying sub class old 'B' burnt bricks, size of brick 30x115x75mm, laid perpendicular to cable length as cable protection cover complete all as specified and directed.
S&F for sub-main wiring with 2 single core, 4 Sqmm PVC insulated, unsheathed, 1100 Volts grade, FRLS grade, copper multi stranded conductor drawn in and including PVC conduit of min 20mm size including drawing one run of PVC insulated, unsheathed, 1100 Volts grade, FRLS grade, copper conductor multi stranded of 4.0 Sqmm size as continuous earth wire drawn through and connected to main switch/DB and testing on completion complete all as specified and directed. Note: 2 runs of main conductor, one run of earth conductor and one run of PVC conduit shall be measured as one unit length complete all as specified and directed.
akhil enterprises
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .