Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹37.0 LAccepted-AOC | L1 | Accepted-AOC Accepted being lowest | |
| 2 | L2₹38.9 L+₹1.9 L (5.19%)Rejected-Finance | L2 | Rejected-Finance Rejected being other than lowest | |
| 3 | L3₹40.6 L+₹3.6 L (9.82%)Rejected-Finance | L3 | Rejected-Finance Rejected being other than lowest | |
| 4 | L4₹44.8 L+₹7.8 L (21.0%)Rejected-Finance | L4 | Rejected-Finance Rejected being other than lowest | |
| 5 | L5₹46.2 L+₹9.2 L (24.8%)Rejected-Finance | L5 | Rejected-Finance Rejected being other than lowest |
Tender Value
Refer Docs
EMD Value
₹73,000
Closing Date
23 Jan 2021, 6:00 pmClosed
Shri D S Dhurpate Offg AGE Contracts
Garrison Engineer (South) Military Engineer Services Pottinger Road, Ahmednagar 414 002
PROVN OF CERTAIN LBW, REV WORKS, SPECIAL REPAIR AND MINOR WORKS AT MIRC UNDER GE (SOUTH) AHMEDNAGAR
2020_MES_404936_1
8764/E8
Open Tender
Miscellaneous Works
Item Rate
180 days
AHMEDNAGAR
Class D Cat a (i)
8 documents required · 8 mandatory
₹500
Garrison Engineer (S) Ahmednagar
₹73,000
Yes
28 Jan 2021
18 Dec 2020
25 Jan 2021
18 Dec 2020
23 Jan 2021
9 Jan 2021
18 Dec 2020 - 24 Dec 2020
Amount
Surface excavation n.exc 30 cm deep and averaging 15 cm deep and getting out in soft/loose soil complete all as specified and directed.
Excavation over areas, n exc 1.5 m deep and getting out in any type of soil complete all as specified and directed.
Treating the bottom and sides of excavation at the rate of 5 ltrs of emulsion per Square metre of surface area with ATT.
Treating the back fill in contract with foundation @ 7.5 ltr of emulsion per Sqm of vertical surface area with ATT.
Treating the top surface of the filled earth @ 5.00 ltr of emulsion per Sqm of surface area with ATT.
Treating the soil under the plinth protection at the rate of 5 ltrs of emulsion per Square metre of surface area with ATT.
Hardcore of gauge exc 63 mm but n exc 100 mm, deposited, spread and levelled in layers n exc 15 cm thick, watered and rolled / rammed to a true surface complete all as specified and directed.
Moorum filling in floors or pavings, laid in layers n exc 15 cm thick, spread, levelled and rammed including watering complete all as specified and directed.
Cement concrete 1:3:6, type C-2, using 40 mm graded stone aggregate, 75 mm thick as in plinth protection including finishing the surface fair and even laid in alternate bays system, length of each bay n exc 1.5 mtr, including forming 12mm wide and 50 mm deep joint, filled with mastic filling to the full depth comprising mixture of one part heated blown bitumen of 85/25 penetration and two parts sand by (volume) complete all as specified and directed
Excavation in trenches n exc 1.5m wide and n exc 1.5m in depth; for foundation and getting out in any type of soil complete all as specified and directed
Moorum/ Red bajri filling in floors or pavings, laid in layers n exc 15 cm thick, spread, levelled and rammed including watering complete all as specified and directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25cm thick, in soil complete all as specified and directed.
Removing excavated material (soil) to a distance n exc 50m and deposited where directed at a level n exc 1.5m above the starting point complete all as specified and directed.
Plain cement concrete 1:4:8 mix, type D-2 (using 40mm graded stone aggregate) as in foundation and mass concrete complete all as specified and directed.
Reinforced cement concrete M-25 (design mix) using 20 mm graded crushed stone aggregate as in slabs supported on walls, beams and columns in floors, roofs complete all as specified and directed by Engineer-in-Charge.
Reinforced cement concrete M-25 (design mix) using 20mm graded crushed stone aggregate as in Columns, pillars, piers, posts and struts etc. complete all as specified and directed by Engineer-in-Charge.
Reinforced cement concrete M-25 (design mix) using 20mm graded crushed stone aggregate as in beams, cantilevers, bressummers, lintels over 1.5 m span etc. complete all as specified and directed by Engineer-in-Charge.
PCC 1:3:6, type C1, using 20 mm graded stone aggregate as in coping, bond stones , bands and similar items incl weathering, slightly rounded or chamfered angle and throating complete all as specified and directed.
Reinforced cement concrete nominal mix 1:2:4 type B1 using 20 mm graded aggregate as in slabs supported on walls and in shelves and the like complete all as specified and directed.
Brickwork with fly ash bricks straight or curved on plan exc 6 m mean radius built in cement mortar 1:6 complete all as specified and directed.
Brick work with fly ash bricks, straight or curved on plan to any radius in half brick thick walls, built in cement mortar 1:4, complete all as specified and as directed.
Formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (horizontal or sloping) complete all as specified and directed.
Form work to side and soffits of beams for rough finished surfaces of concrete flat.
Formwork to sides of pillars, posts, struts, piers, columns etc. complete all as specified and directed by Engineer-in-Charge.
DPC 40 mm thick with cement concrete 1:2:4, type B0 using 12.5 mm graded stone aggregate laid over 200 micron sheet and one coat of bitumen 85/25 complete all as specified and directed.
Form work to sides of slabs, shelves etc exc 10 cm but not exc 20 cm wide complete all as specified and directed by Engineer-in-Charge.
Second class hard wood , 35 mm thick, gauged & skeleton shutters, factory made open rebated any prepare to receive glass, gauge etc (with sash bar), edges of framing plain, chamfered or rounded, titted with cut & mitred beads for securing glass etc., size of members of shutter shall be as spd in SSR 1991 Part-I, Member shall be kiln seasoned as IS-1141 & chemically pressure treated as per IS-401 complete all as spd & directed.
Second class hardwood , 35 mm thick,factory made , plain framed ,panelled shutter (two panels ) with panel of 9 mm thick BWP plywood bonded with high quality phenol formal dehyde synthetic resin adhesive confirming toIS-710. the size of rails & style shall be as per IS -1003 (Part I) kiln seasoned as per IS -1141 & chemically pressure treated as per IS-401 complete all as spd & dir.
Aluminium anodised tower bolt of extruded section of 150 mm size, fixed complete all as specified and directed.
300 mm long mild steel sliding door bolt plate type stove enamelled black bright with bolt not less 12mm dia with and incl. a minimum of 6 bolts and nuts four on bolt plate two on staple plate complete all as specified and directed.
Butt hinges, medium weight, cold rolled mild steel, 100 mm long, ISI marked, fixed complete all as specified and directed.
150 mm long handle of extruded aluminum alloy, anodized, fabricated type, fixed complete all as specified and directed.
Galvanized mild steel wire cloth 0.56 mm nominal dia of wire & average width of aperture 1.18 mm & fixed with wooden beads /tinned tacks or galvanised wire staples & fixed to steel / wooden frame work complete all as specified & directed.
Factory made solid panel PVC door shutter 30mm thick (style) consisting of frame made out of MS tubes for top & bottom rails. M S frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheet for top rail, lock rail & bottom rail on either side and as gap insert for top rail & bottom rail; Paneling of plain colour PVC sheet to be fitted in the MS frame welded / sealed to the stiles & rails with suitable PVC sheet beading, and joining together with solvent cement, supplying & fixing in the frame at site as per specification & drawing.
Factory made PVC solid single door frame (chowkhats) of size 50 mm x 47 mm made out of 5 mm plain colour PVC sheet reinforced with MS square tube, supplying and fixing in opening all as specified in SSR part-II 2004 Section-8, clause 8B.3 to 8B.3.2 and shown on drawing in page No 150 of SSR part-II 2004.
100 mm size PVC butt hinges, ISI marked, fixed complete all as specified and directed.
150 mm long PVC handles, ISI marked, fixed complete all as specified and directed.
200 mm long PVC tower bolt, ISI marked, fixed complete all as specified and directed.
Mild steel barrel tower bolt 200 mm long stove enamelled black with bright bolt and fixed complete all as specified and directed.
Mild steel pressed handles of size 125 mm, oval type stove enamelled black, ISI marked, fixed complete all as specified and directed.
Towel rail, brass chromium plated, 20 mm dia 'D' type, 60 cm long between flanges, fixed with screws and gutties complete all as specified and directed.
Roof trusses (framed ) ,trussed ,purlins,crane,gantries,rails and fastenings and heavy bracket framing (beam,tee,angle ,channel or flat section)including distance piece ,cleats etc conforming to IS 1161-1979 grade Fe 410-W(Gde -E-250) Quality -A complete all as specified and directed.
Framed work such as grills, gratings etc with ends of bars shouldered and/or riveted or forged into spikes; framed guard bars, barred iron doors ladders, framed balusters, walk ways railings, framed work fo fixing for galvanised stee wire , and similar sork conforming to Fe-410 or 310 - O. complete all as specified and directed.
TMT bars 6 to 8 mm dia , cut to length, bent to shape required including cranking, bending spirally or hooping for column, hooking ends and binding with and including mild steel wire(annealed) not less than 0.90mm dia complete all as specified and directed.
TMT bars 10 mm dia and over, cut to length, bent to shape required including cranking, bending spirally or hooping for column, hooking ends and binding with and including mild steel wire(annealed) not less than 0.90mm dia complete all as specified and directed.
TMT bars 5 mm dia and over upto and including 10mm dia in stirrups, spacers and binders and binding with and including mild steel wire(annealed) not less than 0.90mm dia as in stirrups, complete all as specified and directed.
Rolled sections as in main and cross beams, hip and jack rafters; purlins where connected to common rafters and running rails and guides for sliding doors; fixed with angle cleats or other connecting plates complete all as specified and directed.
Pressed steel frames for doors with one with one or more rebates size of frame (125 mm x 60 mm ) including necessary fixing lugs, hinges, lock strike plate, etc.,complete as specified and directed.
Factory made steel windows with side hung shutter including projecting type hinges with steel handle and steel peg stay complete with glazing bars,dovetailed or welded complete all as specified and directed.
Factory made steel windows with side hung shutter including projecting type hinges with steel handle, and steel peg stay complete without glazing bar with & including fixing flat iron for securing wire mesh complete all as specified and directed.
20 mm thick cement plaster in cement morter (1:4) using water proofing compound @ 3 kg by weight of cement & applying evenly a tack coat of industrial bitumen 85/25 at the rate of 1.2kg per sq.m including cleaning surface complete all as specified and directed.
APP polythene membrane, minimum weight 3kg/sqm and minimum 3 mm thick reinforced with polyster non wooven fabric weight not less than 150 gms/sqm incl primer for surfaces by forced application complete all as specified and directed.
Applying of two coats of aluminium paint over APP membrane laid over roof complete all as specified and directed.
Applying evenly a tack coat of industrial bitumen 85/25 at rate of 1.2 kg/sqm including cleaning surfaces complete all as specified and directed.
Machine cut kota stone flooring 20-25 mm thick (size of kota stone slab 22"x22") laid over and including 20 mm thick bedding layer CM 1:6 with pigments to match the shade of slab including cutting, rubbing and mirror/ granite finish polishing including removing dust complete all as specified and directed.
All as per ser item no. 55 here-in-before but 18 to 20 mm thick kota stone on vertical surfaces such as in skiting /dado of size as required at site including10 mm thick backing coat of plaster in cm (1:4) complete all as directed.
75 mm thick PCC 1:4:8, type D-2, using 40 mm graded stone aggregate as in a sub base of floors complete all as specified and directed.
25 mm thick cement concrete 1:2:4,type B-0, using 12.5 mm graded aggregate mixed with WPC @ 3% by weight of cement (WPC will be paid seperately) laid even and smooth complete all as specified and directed.
Glazed ceramic tiles (plain or printed) of each tile of size exceeding 0.11 Sqm but not exceeding 0.18 sqm, 7 mm thick as on vertical surfaces like dado, skirting etc jointed in neat cement slurry and pointed in coloured cement laid over and including 10 mm cement plaster backing in CM 1:4 complete all as specified and directed.
Non-skid coloured ceramic tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.06 Sqm but not exceeding 0.11 sqm, as in floors etc. laid over and including 15 mm thick screed bed in CM 1:6, set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles complete all as specified and directed.
10 mm thick cement plaster in cement mortar 1:6 on brick work or concrete surfaces, finished fair and even without using extra cement complete all as specified and directed.
5 mm thick cement plaster in cement mortar 1:4 on fair faces of concrete ceiling surfaces finished even & smooth without using extra cement complete all as specified and directed.
Cement screed 10 mm thick in cement mortar (1:4) on concrete surface finishing the surface even and fair using WPC @ 3% of weight of cement complete all as specified and directed.
Preparation of newly plastered surfaces of walls and applying two coats of cement base paint complete all as specified and diercted.
Preparation of new surfaces and applying three coats of white wash on ceiling surfaces complete all as specified and directed
Preparation of newly plastered surfaces of walls and applying two coats of dry distemper over a coat of white wash complete all as specified and directed.
15 mm thick cement plaster in cement mortar 1:4, on fair faces of brick work or concrete surfaces finished even & smooth without using extra cement complete all as specified and directed.
Sheet glass 3 mm thick, plain, ordinary quality & glazing with oil putty in square n.exc 0.50 sqm in each pane complete all as specified and directed.
Frosted or figured glass, pin headed type 3 mm thick & glazing with oil putty in square n.exc 0.50 sqm in each pane of metal frame complete all as specified & directed.
Preparation of new wooden or wood based surfaces of any description over 10 cm width or girth & applying two coats of synthetic enamel paint over one coat of pink primer complete all as specified and directed.
Preparation of new steel surfaces of any description over 10 cm width or girth & applying two coats of synthetic enamel paint over one coat of red oxide primer complete all as specified and directed.
1000 ltrs capacity rotational mounded polythene water storage tanks (cylindrical vertical covered with lid on top) ISI marked, hoisted and fixed in position including 20 mm dia float valve complete all as specified and directed.
Cast iron soil, waste and vent pipe, centrifugal type 75 mm bore, sand cast in any length, with or without ears, with lead joints, fixed to walls with and including stack clamps, nuts , bolts etc. and making necessary connections complete all as specified and directed.
Cast iron soil, waste and vent pipe, centrifugal type 100 mm bore, sand cast in any length, with or without ears, with lead joints, laid in trenches including necessary earth work complete all as specified and directed.
Vitreous China wash hand basin White of 580 x 450 mm size flat back including cutting for and pinning in ends of brackets, including waste coupling CP and waste / vent pipe and brackets but excluding taps, fixed complete all as specified & directed.
15 mm bore, bib tap, cast copper alloy, fancy type, chromium plated with crutch or butterfly handle, screwed down screwed for iron pipe or for brass ferrule, fixed complete all as specified and directed.
Low level duel flushing cistern of PVC 10 ltr capicity including 45 cm long PVC connection with brass nut at both ends, PVC flush pipe 32 mm bore and mild steel brackets of angle iron 25 x 25 x 3 mm, oval all length 20 cm with red-oxide primer complete all as specified (ISI Marked) fixed.
Cast iron floor trap centrifugal type with CP grating including jointing to waste pipe in run lead dia of outlet 75mm including cutting floor and making good to match with existing surface and fixed complete all as specified and directed.
Pillar taps, 15 mm bore, cast copper alloy with capstan heads cromium plated screwed down high pressure with or without lettered 'HOT' or COLD with long screwed for iron pipe and fixed complete all as specified and directed.
Angle stop cock, fancy type, brass chromium plated with CP wall cap, 15 mm bore & fixed complete all as specified.
Cast iron cowl centrifugal type suitable for 75 mm bore pipe & fixed complete all as specified and diercted.
110 mm dia PVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in trenches, complete all as specified and directed.
PVC (SWR) bends any radius 110 mm bore equal or unequal fixed complete all as specified and directed.
75 mm dia PVC (SWR) pipes single socketed, in any length with rubber ring joints, fixed to walls, complete all as specified and directed.
PVC (SWR) vent cowl 75 mm bore fixed complete all as specified and directed.
Concrete bed to drain pipes 100 mm bore including packing under and haunching against the side of pipes after they are laid and tested complete all as specified and directed.
Brass chromium plated telephonic shower with 1.20m long connection pipe and fixed suitable for 15mm bore pipe complete all as directed and specified.
Water closets, Vitreous China, Orissa Pattern of size 580 x 440 mm, with white integral foot rest including cast iron `P' or `S' trap & connections to flushing pipe, anti syphonage pipe etc, fixed complete all as specified & directed.
Vitreous China bowl urinal, flat back coloured of size 465 mm x 355 mm x 265 mm, white (Minimum) with grating and union for discharge pipe, fixed in repairs , including providing and fixing plugs, bedding urinals against the wall in cement mortar 1:2, securing urinal to plugs with and including 60mm long brass screws, pointing around the urinal back in cement, including fixing automatic flushing cistern with brackets, PVC flush pipe 32 mm bore (Make DIPLAST), complete all as specified and directed.
Pre- painted galvatume aluminum zinc coating GI based corrugated steel sheet 0.50 mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified, colour and design as approved by GE complete all as specified and directed.
Pre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, ridges, hips, valley gutters, drip and straight flashings fixed with self tapping screws as specified colour and design as approved by GE complete all as specified and directed.
Interlocking aluminium alloy anodised snap grid consists of main Tee runners of size 38 mm X 25 mm X1.5 mm spaced 1200 mm c/c and cross Tee of size 25 mm X25 mm X 1.5mm ,1200 mm long spaced between the main Tee at 600 mm c/c to form a grid of 1200 mm X 600 mm and provide a secondary cross tee 25 mm X25 mm X1.4 mm (of length 600 mm) to be interlocked of the centre of 1200 mm X600 mm panel to form a grid of 600 mm X 600mm and wall angle 25 mm X25 mm X2 mm . etc complete all as directed.
Hangers 6 mm dia, GI (up to 1200 mm length) adjusting level fixed to roof slabs by means of ceilling cleats made out of GI flat 40 x 3 mm size 60mm long and expension hold fasteners 12.5mm dia. 40mm long complete all as specified and directed.
Gypsum board 12 mm thick for insulation and accoustic purposes, 60 cm x 60 cm in size, fixed with nails to timber frame work or with staples on snap grid complete all as specified and directed.
Dismantling floor .hearth or wall tiling including cement mortar bedding, removing serviceable tiles to store and removing the rubbish off the premises. complete all as specified and directed.
50 mm thick PCC 1:2:4, type B-1, using 20mm aggregate as in floor,pavings etc. complete all as specified and as directed.
Non-skid coloured ceramic tiles, ( joint free) of size not exceeding 0.11 sqm x 7 to 8 mm thick, in swimming pool floor etc. set and jointed with Dr fixit roff GTA or equivallent adhesive and joint filling using Dr fixit roff epoxy or equivalent as approved by GE complete all as specified and directed.
Glazed coloured ceramic tiles 200 mm x 300 mm x 6 to7 mm thick coloured on vertical surfaces, set and jointed in Dr fixit roff GTA or equivalent adhesive and joint filling using Dr fixit roff epoxy or equivalent adhesive as approved by GE, including 15 mm thick rendering of CM 1:4 on backing complete all as directed and specified.
Glass tiles of approved pattern,size & design for swimming pool on floor & walls with glass mosaic tile adhesive in a ratio of 1:3 with necessary mortar bed as per menufacture instructions,including moistening the tiles with damp sponge and grouting of tiles in Dr fixit epoxy grout or equivalent etc complete all as specified and directed.Note:-1.) All tiles work exceuted at site as directed by Engr-incharge (2) Whole swimming pool will be chlorine washed after completion of work as approved by GE.
10 to 12 mm thick digital paving tiles fixed with adhesive over 50 mm thick PCC 1:4:8 including spreading, levelling, watering and ramming extra moorum as to match the required level to match level with approved pattern and size including grouting with epoxy complete all as specified and directed. (Note : The cost of moorum required to match the level shall deemed to be included in the unit rate quoted by the bidder)
150 mm internal dia reinforced concrete pipes with collars, of approved make , class NP-3, laid and jointed with cement joint complete all as specified & directed.
Precast RCC cover with SFRC ventilating cover and frame complete all as specified and directed
Concrete bed fo drain pipes 150 mm bore including packing under and haunching against the side of pipes after they are laid and tested complete all as specified and directed.
Septic tank including inlet & outlet chambers for 10 users, in brickwork construction (with top of slab at ground level) including necessary excavation and earth work in any type of soil and disposal of surplus soil to a distance not exc 50 m, bricks work in sub class 'B' bricks built in CM (1:4), RCC 1:2:4, type B1 as in slab including RCC manhole covers factory made ISI marked conforming to IS 12592 with angle iron frame 100mm bore cast iron sand cast vent pipes with cast iron cowls complete all as specified and shown in drawing No. CEPZ/88/TD/17M dated 01 Oct 88, Sheet 1/4 to 4/4.
Soakage wells of size 2.4 mtr dia and 3.00 mtr deep including excavation in any type of soil, foundation in PCC 1:3:6, walls of honey combed masonry with top ring of M25 concrete including intercepting chamber and screen chamber made of Brick masonary in CM, RCC cover slab in M25/ SFRC cover, interconnecting pipes of RCC/DWC complete filled with brick bats & complete all as specified and shown in drawing No. CEPZ/2004/TD/8 Sheet No. 1/1, dated 30 Jun 2004.
PCC 1:3:6, type C-2 (using 40mm graded crushed stone aggregate) as in surface channels and drains complete all as specified and directed.
Extra for forming fair finished drain or channel 30 cm inner girth in cement concrete, using extra cement, including forms, moulds, mitred/stopper ends etc. complete all as specified and directed.
Soakage well of size 1.2 mtr dia & 1.5 mtr deep including excavation in any type of soil, foundation in PCC 1:3:6, walls of honey combed masonry with top ring of M25 concrete including intercepting chamber and screen chamber made of Brick masonary in CM, RCC cover slab in M25/ SFRC cover, interconnecting pipes of RCC/DWC complete filled with brick bats & complete all as specified and shown in drawing No. CEPZ/2004/TD/8 Sheet No. 1/1, dated 30 Jun 2004.
Point wiring with 1.5 Sqmm (22/0.30mm) PVC insulated and unsheathed multistranded copper conductor cable, 1100 volts grade, ISI marked, FR type drawn through and including PVC casing and caping (ISI marked) and its accessories such as Tee, elbow, jointer, elbow corner etc. fixed on surface of walls, coloumns/ beams alongwith 1.5 Sqmm (nominal area) copper conductor cable (multistranded) PVC insulated and unsheathed as earth wire connected to common earth dolly at one end and metalic bodies of luminaire/ fan at other end including PVC folding boards or wooden boards with sunmica top for mounting switches, sockets, fan regulators, accessories etc complete all as specified and directed for One light point and one fan point controlled by one, one way swtich. Make of wire- HPL/Polycab/Havells/Standard./Anchor (Switches, sockets, fan regulators and other accessories shall be measured and paid for separately).
All as per serial item No. 111 here-in-before but one 5 Amp 5 pin socket outlet point on same board with other switches including earth wire complete all as specified and directed.
All as per serial item No. 111 here-in-before but one 5 Amp 5 pin socket outlet point on independent board including earth wire complete all as specified and directed.
Switch piano flush button 5 Amp, single pole, one way, 230 volts white finish, fixed complete all as specified & directed. Make - Havells / Leader /Vinay/ Anchor.
Socket outlet flush type 5 pin 5 Amp multipurpose, 230 volts, single pole one way suitable for 3 pin/2pin 5 Amp plug top white/ivory finish, fixed complete all as specified & directed. Make - Make - Havells / Leader /Vinay/ Anchor.
Switch socket combination flush type 5 pin 5 Amp multipurpose, 230 volts, single pole one way suitable for 3 pin/2pin 5 Amp plug top white/ivory finish, fixed complete all as specified & directed. Make -Havells / Leader /Vinay/ Anchor.
Lamp holder,Angle/BattenType PVC/Polycarbonate type with back plate suitable for batten fittings, fixed in replacement complete all as specified & directed. Make -Havells / Leader /Vinay/ Anchor.
Ceiling rose surface PVC 65x50 mm dia 3 terminals including PVC mounting block, white/ivory finish fixed in replacement complete all as specified & directed. Make -Havells / Leader /Vinay/ Anchor.
LED Lamp suitable to fit in holder of 9 to 10 Watt, fixed complete all as specified and directed. Make Havells/CG/Bajaj/Surya
Factory made box type batten for LED tube light complete with all accessories made up of rigid MS powder coated sheet of suitable thickness and suitable for LED tube rod of capacity 20/ 22 Watt prewired fixed in replacement complete all as specified & directed. Make - Havells Cat Part No. Professional luminaires Item Code - REGALBATTENT8UPTO1X22WSSBSWH or equivalent in make Philips/ CG/ Wipro .
LED Tube rod of capacity 20 watt complete with all accessories,fixed in replacement complete all as specified & directed. Make - Havells cat Part No.Professional luminaires item Code PHOTONULTRA1213T8SSTL20WLED865SPC Or equivalent in Make Philips/ CG/ Wipro .
Sheet metal enclosure (Factory made) double door shutter type for distribution board (when MCBs are to be used) single pole and neutral 240 volts 6 way with 200 Amps rated busbar, complete all as specified and diercted. Make- HPL/ABB/ L&T/Schieder/Legrand
Sheet metal enclosure (Factory made) double door shutter type for distribution board (when MCBs are to be used) single pole and neutral 240 volts 8 way with 200 Amps rated busbar, complete all as specified and diercted. Make- HPL/ABB/ L&T/Schieder/Legrand
MCB SP, 6 to 32 Amps 10 KA single pole AC 230 volts, fixed in replacement complete all as specified and diercted.Make- HPL/Standard/ L&T/Schieder/Legrand
MCB SPN 6 to 40 Amps 10 KA AC 230 volts, fixed in replacement complete all as specified and diercted.Make- HPL/Standard/ L&T/Schieder/Legrand
Earthing complete with galvanized steel earth plate electrode 60 cm X 60 cm X 6.3 mm thick buried directly in ground (earth pit not less than 2.25 mtr deep below normal ground level) with top edge of plate not less than 1.5 mtr below ground level connecting to the GI wire 4 mm dia, by means nut bolt, nuts, check nuts and washer of the GI Earth wire protected by provision of GI light grade pipe 15 mm, GI light grade 20 mm bore pipe for watering perforated at bottom 1.75 mtr long placed on top edge of earth plate, common salt and charcoal filling, taste point made out of phosphorus bronze with fixing arrangement, funnel, wire mesh and earth work in hard/dense soil, returning filling in and removal of surplus soil to a distance not exceeding than 50 mtr, all as per electric plate No 3 of SSR Part I 2009 and connection to earth test point complete all as specified incl testing on completion”.
Celing fans AC single phase 230/240 volt of size 1200 mm sweep, energy efficient, fixed in position complete all as specified and directed.Make- Usha/Havells/CG
Exhaust fans AC single phase 230/ 240 V of size 300 mm sweep metallic body copper wound with self opening and closing louvers for protection from birds and rain water , fixing by means of rugged bolts, nuts and washers etc. and foundation brackets, making connection from ceiling rose to fan with and including 1.5 sqmm conductor cable including making hole in existing stone masonary/ brick wall complete and testing at site complete all as specified and directed.
Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5 m in depth for laying pipes/cables etc and getting out in soft / loose soil complete all as specified and as directed.
Returning, filling in soil , including spreading, levelling, watering and well ramming in layers not exceeding 25cm thick complete all as specified and as directed.
Removal of excavated material [soil] to a distance not exceeding 50 m and depositing where directed at a level not exceeding 1.5 m above the starting point complete all as specified and as directed.
Sand cushioning to cable with 80 mm layer before laying of cable and 150 mm gently tamped to 100 mm thick after laying the cable in trenches/ ducts for cable including consolidation complete all as specified and directed. NOTE : For measurement purpose only punned thickness of sand shall be considered.
Cable protection with well burnt sub class 'B' bricks laid flat with width equal to length of brick laid dry over electric cable perpendicular to the direction of the cable complete all as specified and directed.
LT XLPE insulated, PVC sheathed,armoured heavy duty, electric cable with aluminium conductor of size 10 sqmm 4 core,1100 volts grade conforming to relevant IS, ISI marked, laid in trenches / wall / floor/ poles etc as in repairs,complete including making connection using suitable size aluminium lugs including testing and commissioning complete all as specified and directed by Engineer-in-charge. (Excavation / earth work, sand cushioning and cable covers shall be measured and paid for separately under respective item). Make: Havells/Polycab/Plaza/RR Cable
LT XLPE insulated, PVC sheathed,armoured heavy duty, electric cable with aluminium conductor of size 6 sqmm 2 core,1100 volts grade conforming to relevant IS, ISI marked, laid in trenches / wall / floor/ poles etc as in repairs,complete including making connection using suitable size aluminium lugs including testing and commissioning complete all as specified and directed by Engineer-in-charge. (Excavation / earth work, sand cushioning and cable covers shall be measured and paid for separately under respective item). Make: Havells/Polycab/Plaza/RR Cable
Energy saving LED street light fitting 1x 30 Watt ECO, pressure die cast IP-65 complete with connection using 1.5 Sqmm FRLS PVC insulated (Unsheathed) single core cable, 1100V grade with multistranded copper conductor of required length including testing and commissioning complete all as specified and directed. Make: HPL / Crompton Greaves/ Philips/ Surya/ Havells.
15 mm bore galvanised iron tubing medium grade, ISI marked, complete with all fittings as required and fixed complete, concealed in walls or laid in floors complete all as specified and directed.
20 mm bore galvanised iron tubing medium grade, ISI marked, complete with all fittings as required and fixed complete, concealed in walls or laid in floors complete all as specified and directed.
25 mm bore galvanised iron tubing medium grade, ISI marked, complete with all fittings as required and fixed complete, concealed in walls or laid in floors complete all as specified and directed.
Gun metal globe or gate valves 20 mm bore with iron wheel head, screwed both ends for iron pipe and fixed complete all as specified and diercted.
Gun metal globe or gate valves 25 mm bore with iron wheel head, screwed both ends for iron pipe, and fixed complete all as specified and diercted.
Gun metal globe or gate valves 40 mm bore with iron wheel head, screwed both ends for iron pipe and fixed repairs complete all as specified and diercted.
Cutting/ drilling existing pipe line & taking branch connection complete including all necessary fittings, jointing materials, and earth work etc complete all as specified and directed.
Ms. D.G. SHIRKE
AMAR CONSTRUCTION
M/s.Abhay Kulkarni and Associates
PRADIPKUMAR POPATRAO THUBE
M/s Meher Construction
MS. G.A. CONSTRUCTION
M/s. Sagar Traders
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .