| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹10.6 LAccepted-AOC SHOP NO 10 BMC SHOPPING CENTRE MITHA NAGAR GOREGAON WEST MUMBAI 400 104 | MUMBAI | MUMBAI SUBURBAN | MAHARASHTRA | 400104 | L1 | Accepted-AOC ACCEPTED | |
| 2 | L2₹12.8 L+₹2.0 L (18.0%)Rejected-Finance | L2 | Rejected-Finance NOT LOWEST | |
| 3 | L3₹14.5 L+₹3.6 L (33.5%)Rejected-Finance SWAGAT CO OP HSG SOCIETY LTD 22 303 CHAITANYA SHIVAJI RAJE COMPLEX MHADA COMPLEX OPP EKA NAGAR KANDIVALI W MUMBAI 400 067 | MUMBAI | MUMBAI SUBURBAN | MAHARASHTRA | 400067 | L3 | Rejected-Finance NOT LOWEST |
Tender Value
₹13 L
EMD Value
₹26,000
Closing Date
20 Jun 2020, 6:00 pmClosed
GARRISON ENGINEER DAMAN
GARRISON ENGINEER DAMAN TAT RAKSHAK VIHAR DALWADA NANI DAMAN POST DAMAN (UT) PIN 396210
MAINTENANCE AND REPAIR TO ACs WATER COOLERS REFRIGERATORS AND OTHER CONNECTED ITEMS AT WORLI POWAI MANKHURD AT MUMBAI
2020_MES_331873_3
8469/E8
Open Tender
Civil Works
Item Rate
180 days
MUMBAI
PLEASE REFER TENDER DOCUMENTS
9 documents required · 9 mandatory
₹500
GARRISON ENGINEER DAMAN
₹26,000
Yes
13 Jul 2020
30 May 2020
22 Jun 2020
30 May 2020
20 Jun 2020
6 Jun 2020
Amount
Taking out window/ split type AC of capacity 1.5/ 2.0 TR, opening of the same and checking/ detecting the fault and carrying out necessary repair and replacement of unserviceable spares/ parts as required to make it operational, reassembling and refixing the unit to its position complete all as specified and directed. Notes:- (a) The spares/ parts shall be measured and paid separately under respective items as "supply only". (b) The labour cost for replacement of spares/ parts shall be deemed to be included in this item. (c) The rate shall be inclusive of transport from site to workshop and vice versa before and after the repair. (d) M & L for System fusing, welding, soldering, vaccumising and gas charging if required shall be measured and paid for seperately (e)M & L for Repair to Power control Board (PCB) if required shall be measured and paid for seperately
Servicing of window/ split type AC capacity upto 2.0 TR at site, cleaning and washing of cabinet, evaporator, condenser, ground chasis, filter, oiling and greasing of all movable parts, testing of capacitor and relay, retightening all electrical connections including replacing naked wires with copper conductor wires/ cables as per existing ones, making dry with blower and refixing/ reassembling and refixing the unit to its position all as specified and directed.
Supply only Blower motor complete suitable for window type AC upto 2.0 Ton. Make- Voltas/ Bluestar/ LG/ As on site.
Supply only Indicator suitable for window type AC up to 2.0Ton.
Supply only Thermostat switch suitable for window type AC up to 2.0Ton. Make - Ranotroll, Denfess
Supply only Relay box suitable for window Type AC upto 2.0Ton. Make- Voltas/ Bluestar/ LG/ As on site.
Supply only Plastic air filter suitable for window AC upto 2.0TR. Make- Voltas/ Bluestar/ LG/ Samsung/ As on site.
Supply only Condenser fan of blower motor suitable for window type AC up to 2.0Ton. Make- Voltas/ Bluestar/ LG/ Samsung/ As on site.
Supply only Fan for blower motor suitable for window type AC up to 2.0 Ton. Make- Voltas/ Bluestar/ LG/ Samsung/ As on site.
Supply only Front grill as per existing suitable for Window type AC upto 2.0 Ton. Make- Voltas/ Bluestar/ LG/ Samsung/ As on site.
Supply only Plastic air filter suitable for Split AC Indoor unit AC upto 2 TR. Make- Voltas/ Bluestar/ LG/ Samsung/ As on site.
Supply only Power control Board ( PCB ) for window type / split Type AC up to 2 Ton. Make- Voltas/ Bluestar/ LG/ Samsung/ As on site.
Supply only Wiring kit suitable for split AC and window Type AC upto 2 Ton
Supply only Condenser fan motor complete with fan suitable for outdoor unit of split type air conditioner upto 2 ton . Make - Voltas/Bluestar/LG/ Samsung/Ason site
Supply only Fan for condenser motor suitable for split Type Air conditioner out door unit. Make- Voltas/ Bluestar/ LG/ Samsung/ As on site.
Supply only Relay suitable for Split Type AC upto 2 Ton. Make- Voltas/ Bluestar/ LG/ Samsung/ As on site.
Supply only Cooling coil fan motor complete suitable for in door unit of split Type Air conditioner upto 2 Ton. Make- Voltas/ Bluestar/ LG/ Samsung/ As on site.
Supply only Blower for indoor unit of Split AC upto 2 Ton AC. Make- Voltas/ Bluestar/ LG/ Samsung/ As on site.
Supply only Foaming insulator for AC suction/ cooling line ( Approx - length 15').
Supply only ( hermetically ) sealed uncut compressor unit rotary type for window Type Air conditionerCapacity 2 TR. Make- Voltas/ Bluestar/ LG/ Samsung/ As on site.
Supply only ( hermetically ) sealed uncut compressor unit rotary type for window Type Air conditioner Capacity 1.5 TR. Make- Voltas/ Bluestar/ LG/ Samsung/ As on site.
Supply only ( hermetically ) sealed uncut compressor unit rotary type for Split Type Air conditioner Capacity 2 TR. Make- Voltas/ Bluestar/ LG/ Samsung/ As on site.
Supply only ( hermetically ) sealed uncut compressor unit rotary type for Split Type Air conditioner Capacity 1.5 TR. Make- Voltas/ Bluestar/ LG/ Samsung/ As on site.
Material and labour for System fusing, welding, soldering, vaccumising and gas charging to Split Type air Conditioners Capacity 2 TR. :- { NOTE :- (i) Necessary T & P for gas charging of appliances for mechanic shall be provided by the contractor at his end without any extra cost to the department.}
Material and labour for System fusing, welding, soldering, vaccumising and gas charging to Split Type air Conditioners Capacity 1.5 TR. :- { NOTE :- (i) Necessary T & P for gas charging of appliances for mechanic shall be provided by the contractor at his end without any extra cost to the department.}
Supply only ( hermetically ) sealed uncut compressor unit receprocating type for window Type Air conditionerCapacity 1.5 TR. Make- Kirloskar/ Tecumseh.
Supply only ( hermetically ) sealed uncut compressor unit receprocating type for window Type Air conditionerCapacity 2.0TR. Make- Kirloskar/ Tecumseh.
Material and labour for System fusing, welding, soldering, vaccumising and gas charging to window Type air ConditionersCapacity 1.5 TR.
Material and labour for System fusing, welding, soldering, vaccumising and gas charging to window Type air ConditionersCapacity 2.0 TR.
Supply only Copper tube heavy duty 1/2 " dia
Supply only Copper tube heavy duty 1/4 " dia
Supply only Copper tube heavy duty 3/8 " dia
Supply and fixing rolled mild steel Joist, channel, angle or tee sections ( GDE Fe 290 ) as in framing for stand for voltage stabilizer/ window AC for any other purpose with riveted bolted or welded attachment etc and inclusive of one primer coat , one under coat and one finishing coat of synthetic enameal paint including taking down of old broken steel complete all as specified and as directed.
M & L for Repair to Power control Board (PCB) of Split / Window type AC Capacity 2 TR. Make- Voltas/ Bluestar/ LG/ Samsung/ As on site.
M & L for Repair to Power control Board (PCB) of Split / Window type AC Capacity 1.5 TR. Make- Voltas/ Bluestar/ LG/ Samsung/ As on site.
Supply and Fixing as in Replacement Ply Board 6 MM thick, grade BWR, Type BB, fixed with nails to timber frame work as in cover for window where Window Type AC/Split type AC are installed complete all as specified and as directed. Make of plywood - Greenply/Century/Durian
Taking down voltage stabilizer of any capacity, opening of the same and checking/ detecting the fault and carrying out necessary repair and replacement of unserviceable spares/ parts as required to make it operational, reassembling and refixing the unit to its position complete all as specified and directed. Notes:- (a) The spares/ parts shall be measured and paid separately under respective items as "supply only". (b) The labour cost for replacement of spares/ parts shall be deemed to be included in this item. (c) The rate shall be inclusive of transport from site to workshop and vice versa before and after the repair. (d) Rewinding transformer of voltage stablizer upto 5 KVA capacity with existing guage copper winding of capacity range 90 to 280 Volts if required shall be measured and paid for seperaely
Supply only Trigger Transformer (Control Step- down- transformer) 12-0-12 Volts for 03 KVA to 06 KVA for stabilizer .
Supply only Power Relay 24 Volts / 250 Ohms 30 Amps ( 03- Nos) for 03 KVA to 06 KVA for stabilizer .
Supply only Bakelite Terminal strip 4 Way up to 40 Amps for 03 KVA to 06 KVA for stabilizer
Supply only IC control cord for timer suitable for 03 KVA to 06 KVA for stabilizer .
M & Labour for Rewinding transformer of voltage stablizer upto 5 KVA capacity with existing guage copper winding of capacity range 90 to 280 Volts
Opening of water cooler of any capacity, checking/ detecting the fault and carrying out necessary repair and replacement of unserviceable spares/ parts as required to make it operational, reassembling and refixing the unit to its position complete all as specified and directed. Notes:- (a) The spares/ parts shall be measured and paid separately under respective items as "supply only". (b) The labour cost for replacement of spares/ parts shall be deemed to be included in this item. (c) The rate shall be inclusive of transport from site to workshop and vice versa before and after the repair. (d) Material and labour for System fusing, welding, soldering, vaccumising and gas charging to appliances water cooler if required shall be measured and paid for seperetly .
Supply only Relay box type suitable for water cooler capacity 40-80 Ltr and 60-120 Ltr Make- Voltas/ Usha Shriram/ Blue star/ As on site.
Supply only Relay open type suitable for water cooler capacity 60-120 Ltr Make- Voltas/ Usha Shriram/ Blue star/ As on site.
Supply only Relay open type suitable for water cooler capacity 40-80 Ltr. Make- Voltas/ Usha Shriram/ Blue star/ As on site.
Supply only Over load protector suitable for water cooler capacity 40-80 Ltr and 60-120 Ltr. Make- Voltas/ Usha Shriram/ Blue star/ As on site.
Supply only Condenser fan motor single phase 230 Volt complete with fan suitable for water cooler 40 to150Ltr. Make- Voltas/ Usha Shriram/ Blue star/ As on site.
Supply only Automatic thermostat switch suitable for water cooler 40/80 Ltr and 60-120 Ltr Make- Voltas/ Usha Shriram/ Blue star/ As on site.
Supply only ( hermetically ) sealed uncut compressor unit for water cooler Capacity 40 / 80 Ltrs. Make of water cooler - Voltas/ Usha Shriramr/ Blue star/ As on site.
Supply only ( hermetically ) sealed uncut compressor unit for water cooler Capacity 60 / 120 Ltrs. Make of water cooler - Voltas/ Usha Shriramr/ Blue star/ As on site.
Material and labour for System fusing, welding, soldering, vaccumising and gas charging to appliances water cooler of Capacity 40 / 80 Ltr {NOTE:- Refrigerant gas for charging of equipment compressor shall be provided by the firm and cost there off shall deemed to be included in the unit rate quoated against this Item.}
Material and labour for System fusing, welding, soldering, vaccumising and gas charging to appliances water cooler of Capacity 60 /120 Ltr {NOTE:- Refrigerant gas for charging of equipment compressor shall be provided by the firm and cost there off shall deemed to be included in the unit rate quoated against this Item.}
Supply and fixing as in replacement ball brass valves , high pressure with polythene float and fly nut complete, screwed for iron pipes or brass ferrule and fixed 15 mm complete all as specified.
Supply and fixing as in replacement ball brass valves , high pressure with polythene float and fly nut complete, screwed for iron pipes or brass ferrule and fixed 20 mm complete all as specified.
Supply and fixing as in replacement push cock brass alloy chromium plated 15 mm bore.
Supply and fixing in replacement PVC connection pipe15 mm dia with brass nuts bolts and washers 60 cms.
Supply and fixing as in replacement brass stop cock 15 mm dia.
Supply and fixing as in replacement PVC drain water hose pipe for water cooler of suitable length as directed complete with fixing clamps and elbows/ nipple etc.
Repair to rusted worn out body of water cooler comprising cutting, taking out of rusted MS Sheet from body and providing MS Sheeet of 1.6 mm thickness including necessary cutting, bending, welding and fixing with screws including painting if required , complete as all specified and as directed.
Supply only Running capacitor 25 MFD. Make- Epcos.
Supply only Running capacitor 36 MFD. Make- Epcos.
Supply only Running capacitor 45 MFD. Make- Epcos , Havells.
Supply only Starting capacitor 100 / 120 MFD capacity Make- Tesla, Chezcoslvika, Epcos.
Supply only Starting capacitor 80 / 100 MFD capacity Make- Tesla, Chezcoslvika, Epcos.
Supply only Starting capacitor 60 / 80 MFD capacity Make- Tesla, Chezcoslvika, Epcos.
Supply only Fan capacitor 4 mfd complete all as specified and directed . Make- Tesla, Chezcoslvika, Epcos.
Supply only Fan capacitor 6 mfd complete all as specified and directed. Make- Tesla, Chezcoslvika, Epcos.
Supply and fix in repairs sheet metal enclosure with 2 pin earth plug and socket including MCB SP 20 to 32 Amps 10 KA "C" series and also including removing old unserviceable items all as specified and directed.Make :-Havells/ Legrand/ Standard/ ABB
Removing the unserviceable 3 pin industrial plug top and supply and fix new 3 pin industrial plug top ISI marked suitable for industrial metal clad socket , single phase, 240 volts 20 Amps including connecting complete all as specified and directed. Make :-Havells/ Legrand/ Standard/ ABB
Removing old unserviceable copper cable after disconnecting electrical connection and supply anf fix PVC insulated , sheathed multistandard 1100 volts grade copper conductor cable of size 2.5 sqmm 3 core complete all as specified and directed. Make- Finolex, Havells, Plaza, Polycab Schedule of Credit :- Rs 27,113.00
AIRCON SYSTEMS
cooltech engineering services
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .