| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.4 CrAccepted-AOC DREAM CITY CHABAL ROAD AMRITSAR | AMRITSAR | AMRITSAR | ₹1.4 Cr | L1 | Accepted-AOC Accept |
| 2 | L2₹1.6 CrRejected-AOC 66 RISHI VIHAR PHASE II MAJITHA ROAD AMRITSAR | AMRITSAR | AMRITSAR | PUNJAB | ₹1.6 Cr | L2 | Rejected-AOC Reject |
| 3 | L 3₹1.6 CrRejected-AOC | ₹1.6 Cr | L 3 | Rejected-AOC Reject |
Tender Value
₹1.6 Cr
EMD Value
₹3.2 L
Closing Date
19 Jan 2026, 1:00 pmClosed
Executive Engineer Provincial Division Amritsar
Executive Engineer Provincial Division Amritsar
PROVIDING AND ERECTION OF TWO LIFTS ELEVATORS IN JUDICIAL COURT COMPLEX, AMRITSAR.
2026_CEPW_157348_1
EE/PD/Asr/84 dated 05-01-2026
Open Tender
Civil Works - Buildings
180 days
Amritsar
Please refer Tender documents.
16 documents required · 16 mandatory
₹10,000
₹3.2 L
20 Feb 2026
7 Jan 2026
19 Jan 2026
7 Jan 2026
19 Jan 2026
7 Jan 2026
CIVIL WORK
Construction of Single Storey Building
dismentaling of floor tile at any floor of buiding including scraping of cement plaster and disposal of malba within 100 meter of complex
Dismantling brick work tile masonary or tile lining. (b) In cement
Credit of old material
Bricks
Bricks bats
Scraping Bricks dismantled from brick work in Cement
Providing and fixing double scaffolding system (cup lock type) on the exterior side, up to seven story height made with 40 mm dia M.S. tube 1.5 m centre to centre, horizontal & vertical tubes joining with cup & lock system with M.S. tubes, M.S. tube challies, M.S.clamps and M.S. staircase system in the scaffolding for working platform etc. and maintaining it in a serviceable condition for the required duration as approved and removing it there after .The scaffolding system shall be stiffened with bracings, runners, connection with the building etc wherever required for inspection of work at required locations with essential safety features for the workmen etc. complete as per directions and approval of Engineerincharge .The elevational area of the scaffolding shall be measured for payment purpose .The payment will be made once irrespective of duration of scaffolding. Note: - This item to be used for maintenance work judicially, necessary deduction for scaffolding in the existing item to be done.
Dismantling concrete or precast concrete. (e) Reinforced Cement concrete
Dismentaling Lime concrete, cement concrete of 1:6:12 or leaner mix
Removing Doors and Windows (Steel or wood) with chowkhats by making recesses in walls when the wall is not to be dismantled.
Dismantling aluminium/ Gypsum partitions, doors, windows, fixed glazing and false ceiling including disposal of unserviceable material and stacking of serviceable material within 50 meters lead as directed by Engineer-in-charg
Removing Malba
Earth work in excavation in foundations, trenches etc. in all kinds of soil where pick jumper work is not involved and not exceeding 2.0 metres depth including dressing of bottom and sides of trenches, stacking the excavated soil clear from the edge of excavation
Cement Concrete 1:4:8 with brick ballast 40 mm gauge
First class burnt brick work laid in cement sand mortar 1:5 in foundation and plinth.
Centring and shuttering for columns (Square or rectangular or poly gonal in plain)
Ground floor
First floor
2nd floor
3rd floor
4th floor
5th floor
6th floor
Centring and shuttering for flat surfaces such as suspended floors, roofs, landings, chajjas, shelves etc.
Ground floor
First floor
2nd floor
3rd floor
4th floor
5th floor
6th floor
Extra for shuttering in each subsequent storey above the first. Storey (except for item No.9.16)
1st floor
2nd floor
3rd floor
4th floor
5th floor
6th floor
Reinforced cement cocrete M-25 mechanicaly batch mixed using batch type mixer and needle vibrator mixed but excluding steel reinforcement, centering and shuttering in super structure.
Ground floor
First floor
2nd floor
3rd floor
4th floor
5th floor
6th floor
Extra for R.C.C / PCC work done in subsequent storey above the first storey up to height of 4 metres or part thereof up to the roof top level of that storey.
1st floor
2nd floor
3rd floor
4th floor
5th floor
6th floor
Cold twisted deformed (ribbed/ tor steel) Bars Fe 500 grade as per IS 1786-2008 for R.C.C. works, where not included in the complete rate of R.C.C. including bending, binding, and placing in position complete.
Ground floor
1st floor
2nd floor
3rd floor
4th floor
5th floor
6th floor
Extra for work done in each subsequent storey above the first storey for item No.18.17, 18.18 and 18.19
1st floor
2nd floor
3rd floor
4th floor
5th floor
6th floor
First class burnt brick work laid in cement sand mortar 1:5 in first storey upto 4 metres above plinth level.
Ground floor
First floor
2nd floor
3rd floor
4th floor
5th floor
6th floor
Extra for additional storey upto 4 metres above the top of structural roof of lower storey.
1st floor
2nd floor
3rd floor
4th floor
5th floor
6th floor
12.5mm thick cement plaster 1:4.
20mm thick cement plaster 1:4 in two coat work.
Extra for plastering exterior walls of height more than Third storey from ground level for every additional height of single storey or part thereof.
1st floor
2nd floor
3rd floor
4th floor
5th floor
6th floor
Water proofing treatment of Roof Slab with High performance cementitious two component product, consisting of a powder component and an acrylic polymer using two coats ( Dr Fixit Roof seal flex- Packaging Size:12 .5 kg ( 7.5 kg powder + 5 kg polymer) / equivalent water proofing Solution ). The slurry thus formed by mixing the two, is to be applied on new roofs to forms a seamless, highly elastic, non-toxic waterproofing layer on the roof with a life expectancy of 7 years. The work shall be carried out all complete as per specification and the direction of the Engineer-in-charge
Terracing consisting of tiles 22.86 cm x 11.43 cm x 3.81 cm laid over 25mm mud plaster, 75 mm mud filling on another layer of 25 mm mud plaster including two coats of bitumen laid hot @ 1.65 Kg. per Sqm. on top of R.C.C slab including grouting with cement sand mortar 1:4 and top surface to be left clear after wire brushing etc.
Extra for additional storey of 4 mtr. or part there of 6th floor
Cement concrete 1:2:4 gola 10 cm. x 10 cm. quardrant along junction of roof with parapet wall finished smooth, where specially specified. lift roof
Top khurra 0.6m x 0.6m for rain water pipe in 25mm thick cement concrete 1:2:4 over 50mm thick cement concrete 1:8:16. lift roof
Bottom Khurra on ground 1.2m x 0.6m Mtr. Consisting of brick on edge laid in cement mortar 1:3 over 75mm cement concrete 1:8:16 including 12.5mm thick cement plaster 1:3. lift roof
Providing and fixing on wall face unplasticised Rigid PVC rain water pipes single socketed (working pressure 4 kgf / cm²) conforming to IS : 4985, including fixing with MS clamps. U-PVC pipes (working pressure 4 kgf. / sqcm) pipe 110 mm dia.
Iron grated doors, including pintle hinges & arrangements. lift door
Coloured Granite stone tiles 15mm to 20mm thick in skirting, risers of steps, dado walls and pillars laid in 12.5mm thick cement mortar 1:3 (1 cement 3 coarse sand) and jointed with neat cement slurry mixed with pigment to match the shade of stone, including rubbing and polishing including labour for fixing dowel pins and cramps. lift front wall
Supplying and fixing of Japani sheet frames (Chowkat) consisting of 18 gauge (1.25mm) thick steel sheet of the specified section (standard design latest), including iron lugs (hold fasts) iron hinges conforming to PWD specifications including bolts for fixing steps, lock notch provision for receiving tower bolts and finished, fixed in position including the cost of cement concrete 1:3:6 for filling in the frame and cement concrete 1:2:4 for lugs complete to the satisfaction of Engineer-in-charge. Doors and windows frame of size 161mm x 60mm with 40 mm wide double rebate weighing 4.05 kg per meter.
Factory manufactured solid flush door fixed in position iron hinges, etc (excluding the cost of any fittings other than specified above but including labour for fixing the same in position (Code : II Revision IS-2202-1 (1999): Commercial with elm or gurjan facing on both \ Sides with laminated core and lipped edges:-
Kail wood doors shutter and window shutter panelled, glazed or glazed and panelled including hinges screws chokes cleats and cords etc. complete Fixed in position (Single Leaf
Wire gauze door shutter with Kail wood without springs housed in chowkats (Single Leaf)
Cost of Aluminium fittings complete for doors, windows such as tower bolts, handless and screw etc. for these fittings (Excluding sliding bolt)
Providing & Fixing glass panes with nails and putty or wooden strip complete in all respect Glazing area above 0.09 sqm
Providing and laying vitrified floor tiles in different sizes in light colour shades made using Full Body Technology (thickness to be specified by the manufacturer) with water absorption’s less than 0.08% and conforming to IS : 15622 of approved make in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement: 4 fine sand), complete. ( Full body vitrified tiles have pigment in entire body / thickness of tile which makes chips and scratches less noticeable and make na ideal choice for high traffic zones.) front of lift
Providing and laying 60 mm thick factory made cement concrete interlocking Paving blocks of M- 35 grade manufactured by block making machine equipped with steel mould clamped to a strong vibratory table with hydraulic pressure for compaction of concrete as per IRC SP 63 -2014 and of approved size and design / shape laid in Ordinary Grey Colour and pattern over and including 40 mm thick compacted bed of coarse sand, filling the joints with fine sand etc, all complete as per directions of Engineer-in- Charge.
Extra Cost for using darker fast shade for interlocking pavers Tiles of any shape & thickness instead of grey colours.
Providing and fixing double scaffolding system (cup lock type) on the exterior side, up to seven story height made with 40 mm dia M.S. tube 1.5 m centre to centre, horizontal & vertical tubes joining with cup & lock system with M.S. tubes, M.S. tube challies, M.S.clamps and M.S. staircase system in the scaffolding for working platform etc. and maintaining it in a serviceable condition for the required duration as approved and removing it there after .The scaffolding system shall be stiffened with bracings, runners, connection with the building etc wherever required for inspection of work at required locations with essential safety features for the workmen etc. complete as per directions and approval of Engineerincharge .The elevational area of the scaffolding shall be measured for payment purpose .The payment will be made once irrespective of duration of scaffolding. Note: - This item to be used for maintenance work judicially, necessary deduction for scaffolding in the existing item to be done.
Preparation of plastered or concrete surface for painting (including sand papering the surface) using ready mixed cement based wall putty by applying two coats to get required finish
Distempering with Acrylic washable oil bound distemper (of approved manufacture) two coats over one priming coat to give an even shade.as per PWD Specification No.16.11
Preparation of plywood surface for painting including sand papering the surface and applying filling with approved quality fillers consisting of white lead, linseed oil, Varnish, and Chalk Mitti including finishing the surface to required finish complete.
Applying pink primer or aluminium priming coat with ISI marked quality on wood work including preparation of surface knoting and stopping complete as per PWD specification No. 16.1
Painting two coats excluding priming coat with synthetic enemal paint using special quality paint in all shades on new wood work / metal work surface to give an even shade
Finishing walls with acrylic smooth exterior paint of required shade with two or more coats applied @ 1.67 litre/10Sqm over and including base coat of water proofing Cement Paint applied @ 2.20 Kg/10 Sqm
Extra rates for External white washing, distempering, painting and decorative cement based paints etc for walls of height above Third storey from ground level for every additional height of single storey or part thereof.
ELECTIRCAL WORKS
SURFACE PVC CONDUIT PIPE WIRING SYSTEM WITH MODULAR SWITCHES:
Wiring in PVC insulated copper conductor single core FR cable (ISI marked) overall 1.5sq. mm, 1100volts grade to be laid in heavy gauge PVC conduit pipe 20mm/ 25mm dia (ISI Marked) installed on surface etc., complete with PVC boxes (Plastic on surface boxes) required for suitable number of modules (Modular accessories) for having Step type electronic fan regulators (two module) 100watts, bell push, 6Amp. 2/3 universal socket (shuttered), 16/20Amp. combined/ universal Socket (shuttered), 6/10Amp. Switches, 16/20Amp. switches with indicator etc. and covered with Frame Plate etc., PVC connector (For Fan Box and Call Bell), MS saddle clamp, PVC Circular junction Boxes (Four way 1½" deep for walls), bonding to earth with PVC insulated copper conductor single core FR cable (ISI marked) 1sq. mm, 1100volts grade (For 6Amp. wall socket & plug control point) and other petty material etc., including the cost of above material and painting as required:-
Wiring light point
Wiring 6Amp. wall socket point
XLPE INSULATED UN-ARMOURED CABLES (ON SURFACE):
Supply, laying and erection of aluminium conductor XLPE insulated PVC sheathed Un-armoured and served cable 1100 volts grade as per IS 7098 (Part-1)1988 to be laid (On Surface) as per PWD General Specifications:-
Overall size 50sq.mm (3½ Core) Un-armoured (On-Surface)
PVC, HDPE PIPES & PVC FLEXIBLE PIPES:
Supply & erection of PVC Conduit Pipes (ISI marked) as per IS9537:Part-III & HDPE pipes (ISI marked) as per IS:4984:1995 for wiring purposes including bends, junction boxes, Steel hooks, M.S. saddle clamps and other petty materials etc., as per PWD General Specifications:-
Heavy Gauge PVC Conduit Pipe 25mm dia. (On Surface)
COPPER EARTHING:
8 SWG COPPER EARTHING :
Earthing with 8 SWG (4mm dia.) electrolytic copper wire thimbled (1No. copper thimble with suitable size steel bolt, washers & double nut) with 30cm x 60cm x 2mm thick copper plate (made cylindrical) burried below ground level in the hole of excavation having bore dia. 125mm and surrounded by salt & charcoal dust mixture (20 kg.) including fixing the copper wire run through 20mm dia. G.I. pipe (A-Class) recessed in wall and in floor etc., up to suitable Length in metre (including bore Length). G.I. pipe 20mm dia. (A-class) of suitable Length should be laid in the hole of excavation 1 feet below ground level and having GI Reducer 50mm x 20mm with PVC Cap (For pouring water) fixed on the top level of the pipe. 300mm x 300mm x 300mm deep haudi of First class bricks finished with 1:4 cement plaster and haudi covered with cast iron lid having size 300mm x 300mm (Heavy) around the hole of excavation:-
Earthing with 8 SWG (4mm dia.) copper wire thimbled with 30cm x 60cm x 2mm thick copper plate burried 4.50 metre (14.76 feet) below ground level (up to 8metre in Length) with G.I. pipe 20mm dia. (A-class), 3metre long
Fixing additional Length of earthing with 8 S.W.G. (4mm dia.) copper wire in G.I. pipe with sockets, elbows, steel hooks and GI saddle clamps including painting etc.:-
Additional Length copper wire 8 S.W.G. (4mm dia.) in 20mm dia. G.I. pipe (On Surface)
MINIATURE CIRCUIT BREAKERS:
Supply and erection of Miniature Circuit Breaker MCB's for circuit protection against overload and short circuit current fault suitable for 240/ 415 volts 50cycles AC supply with breaking capacity of 10kA, Curve-C and low watt losses as per IS/IEC 60898-1, energy limitation class-3, true contact indication, label holder facility in the existing MCB distribution board as per PWD General Specifications including connections with suitable size of thimbles/lugs:-
MCB Single Pole 6-32amp. (10kA, Curve-C)
MCB Double Pole 50, 63amp. (10kA, Curve-C)
MCB Four Pole 50, 63amp. (10kA, Curve-C)
RCCB's:
Supply and erection of RCCB (Residual Current Circuit Breaker) for Earth leakage protection suitable for 240/415 volts 50 cycles AC supply with breaking capacity of 10kA as per IEC 61008-1 in the existing MCB distribution board as per PWD General Specifications including connections with suitable size of thimbles/lugs:-
RCCB Four Pole 63amp., Sensitivity 300mA
RCCB Double Pole 32/40amp., Sensitivity 300mA
SHEET METAL DOUBLE DOOR DISTRIBUTION BOARD FOR MCB's/ RCBO's/ RCCB's:
Supply and erection of sheet metal Double Door Distribution Boards IP 43-IK09 metal door (dust protected) as per IS 8623-1&3, IEC 61439-1&3 suitable for flush mounting with fully insulated copper busbars, shrouded neutral bars, earth bars, cement spill protector, color-coded interconnecting wire set, cable ties, blanking plates and circuit identifications label and of required no. of ways for mounting miniature circuit breakers/ RCBO's/ RCCB's in the distribution board (For SP&N distribution board with provision DP MCB's/ RCCB's/ RCBO's as incomer and SP MCB's as outgoings and for TP&N horizontal distribution board with provision TPN/ FP MCB's/ RCCB's/ RCBO's as incomer and SP MCB's as outgoings) as per PWD General specifications including connections with suitable size of thimbles and bonding to existing earth etc:-
TP&N Horizontal Double Door Distribution Board 4 way each
Supply and erection of LED BULKHEAD light 10W Surface Mounted LED Bulk Head Luminaire with ABS Body & Polycarbonate Diffuser, IP54. complete in all respect as per approved /desired by the engineer in charge of work at site certification and specification and warranty of LED Should be as approved by Hon'ble Technical Advisor to Punjab Govt. vide Letter ION No: AT/2021/GL/1410-1422 Dated: 06.05.2021. Besides this the lighting fixtures manufacturers should have in house NABL accredited lab.
Please Enable Macros to View BoQ information
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.87 MB
BOQ_318966.xls
BOQ • 0.58 MB
SBD.pdf
Tender Documents • 20.16 MB
Download all tender documents and submit your bid