Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹42.7 LAccepted-AOC NOT AVAILABLE | L1 | Accepted-AOC L1 | |
| 2 | L2₹43.5 L+₹80,905.85 (1.90%)Rejected-Finance | L2 | Rejected-Finance Not Reasonable | |
| 3 | L3₹57.3 L+₹14.6 L (34.3%)Rejected-Finance B 134 GANESH MURTHI NAGAR PART III COLABA MUMBAI 400 005 | MUMBAI | MAHARASHTRA | 400005 | L3 | Rejected-Finance Not Reasonable | |
| 4 | L4₹64.2 L+₹21.5 L (50.4%)Rejected-Finance 702 A1 SHREE PRASAD TAWADEWADI SHREE DATTAGURU PARK KUMBHARWADA URAN DIST RAIGAD MAHARASHTRA 400 702 | URAN | RAIGAD | MAHARASHTRA | 400702 | L4 | Rejected-Finance Not Reasonable |
Tender Value
₹44 L
EMD Value
₹88,000
Closing Date
17 Feb 2024, 6:00 pmClosed
Saurabh Gupta, EE, GE
GE(W) Colaba Mumbai
PROVN OF DIESEL ENGINE GENERTING SETS FOR STANDBY POWER SUPPLY OF LIFTS AT BLOCK NO P -64, 65, 92, 93,94 P -112 AND A, B, C BLOCK UNDER GE (WEST) COLABA, MUMBAI
2024_MES_638409_1
8839/E8
Open Tender
Civil Works
Item Rate
180 days
GE(W) Colaba Mumbai
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
GE(W) Colaba Mumbai
₹88,000
Yes
1 Apr 2024
20 Jan 2024
19 Feb 2024
20 Jan 2024
17 Feb 2024
3 Feb 2024
Amount
Supplying, installing, testing & commissioning of factory assembled Deisel Engine set coupled with alternator, standard panel, acoustic enclosue & base frame (Approved by CPCB-IV + Compliant and retrofittings of emission control devices (RECD) driven generating set, fully wired alternator AC to given as out put of 100 KVA contineously rating at a PF of 0.8 lagging, 415 volts AC 3 phase 4 wire 50Hz +/- 1% supply, 1500 rpm, 156 BHP directly coupled with diesel engine water cooled mounted on common base frame with floor mounting fuel tank of adequate capacity with fuel line & accessories, PCC foundation work as per manufacturer's instructions, vibration damper pad & other accessories comprising of the following:- (A) Diesel Engine: Make:-Kirloskar cat no 4K10804ETA4G1 /Ashok Leyland Water cooled turbo charged with after cooled to deliver suitable BHP at 1500 RPM under NTP conditions of BS-5514 and confirming to IS-10002, DIN-6271 & ISO-3045 with an overload capacity of 10% for one hour in any 12 contineous hours operation with the following accessories:- a) Radiator with blower fan or heat exchanger with guard. b) Pipe coupling for engine cooling system piping. c) Corrosion inhibitor filters d) Paper element filters. (i) Fuel (ii) Lube oil (iii) By pass e) Fly wheel housing and fly wheel to suit alternator. f) Engine bearing mechanism in fly wheel house. g) Shut off coil with safeties for LLDP/HWT/Over speed. h) Dry type air cleaners and vaccum indicators. j) Residential silencers. k) Stainless steel exhaust flexible bellows. l) Motor driven priming pump. m) Battery charging alternator. n) Exhaust piping made out of STIC 'C' class, MS pipe inclusive of all accessories and hardware, necessary support scaffolding as per OEMs recommendations to sustain back pressure with rain cap. o) First fill of oil, coolant and disel during commissioning & 12 hours testing. p) Interconnecting copper cabling of adequate capacity between batteries control. q) Fuel pipe C class STIC 1"/1.5"/2" dia - 01 lot. r) Self starter 12/24 Volt DC. s) Electronic operated electronic governor. t) Fuel injection pump. u) Electronic instrument panel, (v) Built -in- battery charger (v) suitable size RCC foundation for DG set and all type cable connection (w) Remote monitoring unit complete with all accessories as per manufacturer's specifications displaying the following - (i) Battery voltage (ii) Water/engine temperature (iii) Lubricating oil pressure (iv) Engine speed (v) Engine hours run (vi) Frequency (vii) Voltage W) Safety control (Trip & indication) (i) High water temperature (ii) Low tube oil pressure (iii) Overspeed stop X) Base Frame: Sturdy, fabricated welded construction, channel iron base frame for mounting engine and alternator as per manufacturer's design alongwith AVM pads Y) Battery: Suitable capacity of battery approved by OEM maintenance free battery with leads and terminals. Z) Fuel tank: 8 hours full load diesel stotage capacity fuel tank with mounting brackets factory made of 5mm thick HR/MS sheet with level indicator fuel inlet, fuel outlet, air vent, drain plug, inlet arrangement for diesel filling from exterior of canopy. (B) Alternator: 100 KVA at 0.8 PF, 415 volts, 3 phase, 4 wire, 50Hz, at 1500 rpm, self excited & self regulated with AVR brushless excitation, screen protected, drip proof, insulation class H, IP-23, self ventilated & confirming to BS:5000/IS 4722 suitable for engine as mentioned here-in-before. (C ) Acoustic Enclosure:- M&L for acoustic enclosure for the above 100 KVA DG set to reduce noice level to 75 dB measured at 1.0 metre distance for audible frequencis as per guidelines of Central Polution Control Board and Approved by CPCB-IV + Compliant and retrofittings of emission control devices (RECD) Manufacturer's specification from outhorised OEMs of Gen Set manufacturer specified including inside illumination by 2 nos - 1x20 watt LED fittings
All as per item no 1 but 82.5 KVA capacity 105 BHP (Approved by CPCB-IV + Compliant and retrofittings of emission control devices (RECD) driven generating set, fully wired alternator AC to given as out put of 82.5 KVA contineously rating at a PF of 0.8 lagging, 415 volts AC 3 phase 4 wire 50Hz +/- 1% supply, 1500 rpm, Make:-Kirloskar cat No 4R1190ETA4G1/Ashok Leyland
All as per item no but 50 KVA capacity 105 BHP ( Approved by CPCB-IV + Compliant and retrofittings of emission control devices (RECD) driven generating set, fully wired alternator AC to given as out put of 50 KVA contineously rating at a PF of 0.8 lagging, 415 volts AC 3 phase 4 wire 50Hz +/- 1% supply, 1500 rpm, Make:- Kirloskar cat No 4R810EETA4G1//Ashok Leyland
Excavation in trenches not exc 1.5mtr. In depth and not exc 1.5mtr in width and getting out in soft/ loose soil all as specified and directed.
Returning, fillling in including, spreading, levelling, watering and well ramming in layers not exceeding 25cm thick in soil all as specified and directed.
Removing excavated surplus soil to a distance nexc 50 m and depositing where directed at a level not exc 1.5 mtr above the starting point all as specified and directed.
Supply lay/spread in trenches, crushed stone sand,clean, including spreading, levelling, punning for laying /cushioning of cables all as specified and directed. Note:- For the purpose of payment only punned thickness will be measured.
Supply lay in trenches fly ash bricks, old size sub class “B” for cable protection all as specified and directed..
Supply, laying connecting and testing XLPE insulated, PVC sheathed, armoured LT electric power UG cable (heavy duty) with stranded aluminium conductor, 1100 Volts grade, cross sectional area 95 Sqmm, 3.5 core laid through duct/ pipe / in trench etc. including cable glands & lugs all as specified and directed.
Supply, laying connecting and testing XLPE insulated, PVC sheathed, armoured LT electric power UG cable (heavy duty) with stranded aluminium conductor, 1100 Volts grade, cross sectional area 50 Sqmm, 3.5 core laid through duct/ pipe / in trench etc. including cable glands & lugs all as specified and directed.
S&F 50 mm bore GI Tubing light grade under road, on pole floor and on wall for cable protection all as directed.
S&F onload changeover 125 Amps 415 Volts, 50 HZ with sheet metal enclosure all as specified and directed. Make :-L&T/Havells/ Schneiderr/Siemens/ABB-
S&F MCCB TPN, 240 Volts, 160 Amps, 10 kA rupturing capacity 415 Volts with suitable sheet metal cover all as specified and directed. Make: Havells /Schnieder/L&T/Legrand
M&L PCC 1:4:8 type D2 (using 40mm graded crushed stone aggregates), 150mm thick as in sub base all as specified and as directed.
M&L 40mm thick PCC (1:2:4) type B1 (using 20mm graded crushed stone aggregates) as in floor and finishing cement conerete surface even and smooth with using extra cement all as specified and directed.
M&L for earthing complete with galvanised steel earth plate electrode 60 Cm X 60 Cm X 6 mm buried directly in ground vertically to a depth not less than 2.25 mtr deep below ground level with top edge of earth plate at a depth not less than 1.5 m below normal ground level connected to galvanised Strip 32x 6 mm by means of bolts, check nuts and washers, galvanised steel and protected by GI pipe 50 mm bore light grade & connected to main switch board or main control board as directed and including concrete pit in PCC (1:3:6) type C1, precast RCC (1:2:4) type B1 cover slab 30 cm X 30 cmX 5 cm with 10mm dia TMT bars 8 cm C/c both ways and one handle for lifting made out of 8 mm dia TMT bar, funnel, wire mesh, 20mm bore galvanised iron pipe (medium grade) for watering, charcoal or coke and salt in alternative layers, necessary excavation and earth work in any type of soil and including necessary testing completion all as shown in Electrical Plate No 3 of SSR part -I.
Supply & fix GI strip 32 x 6 mm buried in ground all as specified and directed.
NOEL ENGINEERS
SHRI SAI ENTERPRISES
Sagar Electricals
Bidder Name
Sagar Electricals
SHRI SAI ENTERPRISES
NOEL ENGINEERS
SHREE JAGDISH FURNITURE CO.
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .