| 1 | L1₹13.6 LAccepted-AOC SHOP NO 10 BMC SHOPPING CENTRE MITHA NAGAR GOREGAON WEST MUMBAI 400 104 | MUMBAI | MUMBAI SUBURBAN | MAHARASHTRA | 400104 | L1 | Accepted-AOC LOWEST TENDERER | |
| 2 | L2₹18.6 L+₹3.9 L (26.6%)Rejected-Finance FLAT NO 401 TULSANI HEIGHTS 4TH FLOOR GREEN PARK SOCIETY AKURDI GURUDWARA TO WALHEKAR WADI ROAD CHINCHWAD PUNE 411033 | PUNE | MAHARASHTRA | 411033 | L2 | Rejected-Finance GREATER THAN L1 | |
| 3 | L3₹21.5 L+₹6.8 L (46.5%)Rejected-Finance 503 GIRIRAJ HEIGHT VAITY WADI L B S MARG NEAR HARINIWAS CIRCLE THANE 400 602 | THANE | MAHARASHTRA | 400602 | L3 | Rejected-Finance GREATER THAN L1 |
Tender Value
₹18 L
EMD Value
₹36,000
Closing Date
14 Feb 2022, 6:00 pmClosed
P Bangar Raju,IDSE
GE (I) (NAVY), INS SHIVAJI - POST, LONAVLA -410402
REP/MAINT TO INTERNAL ELECTRIFICATION, CEILING FANS, EXHAUST FANS AND REPAIR/MAINT OF EXTERNAL ELECTRIC SUPPLY TRANSFORMER INCLUDING OH LINES AND UG CABLE AND REPAIR/MAINT OF STREET LIGHTS, DG SET AND CONNECTED ACCESSORIES OF AF STATION LONAVLA
2022_MES_503161_1
GE/LONAVLA/8049/E8
Open Tender
Civil Works
Item Rate
180 days
GE (I) (NAVY) LONAVLA
As per NIT /Tender documents
6 documents required · 6 mandatory
₹500
Yes
GEINDEPNAVYLONAVLA
₹36,000
Yes
25 Feb 2022
22 Jan 2022
16 Feb 2022
22 Jan 2022
14 Feb 2022
1 Feb 2022
22 Jan 2022 - 31 Jan 2022
Amount
Taking down carefully copper/aluminium point wiring (light, fan, socket or power) complete,(fittings such as switches, ceiling roses, pendants, regulators sockets etc. to be measured separately), removing materials to store for keeping in safe custody for issue under Schedule of credit and making good disturbed surfaces of walls, floors, etc.
Taking down MCB DBs / SFUs
M & L for point wiring with 1.5 sq mm single core FRLS PVC insulated cable 1100 V grade with multistranded copper conductor drawn through PVC casing and capping with all accessories fixed to wall /roofs ceiling etc and incl provision of 1.5 sq mm PVC insulated and unsheathed copper conductor as earth continuity conductor and connected to common earth dolly incl fabricated steel terminal box made out of 1.6 mm thick MS sheet concealed in the wall with 3 mm thick laminated sheet top cover / PVC Switch Board mounted on wall for mounting the switches , socket outlets , fan regulators etc all as s specified and directed for following. (a) One light/Fan point controlled by one switch.
(b) One socket 3 pin outlet 5 amp on independent board.
(c) One 3 pin socket outlet 5 amp on the same board board with other switches.
(d) One bell/buzzer point controlled by one push button on the same board with other switches or independent with cable 1.5 sq mm size.
All as per item no 3 above but with copper conductor cable for one 3 pin socket outlet 15 amp independent board with cable 2.5 sq mm.
S&F in repairs switch piano flush type single pole one way 5 amp.
S&F in repairs ceiling rose three terminal/PVC polycarbonate, isolated body complete all as specified.
S&F in repairs switch socket combination 2 in 1, 3 pin 5/15 amp flush type. .
S&F in repairs switch socket combination 2 in 1, 5 amp flush type.
S&F in repairs socket outlet 2 in 1, 3/5 pin 5 amp multi purpose, flush type.
S&F in repairs switch bell push, flush type 5 Amp.
S&F in repairs bell, Multi music type AC, 230 Volts single pole.
S&F in repairs fan regulator electronic step type complete all as directed by EIC at site
Labour only for taking down and fixing with repairs to Ceiling Fan with Fan regulator, Exhaust Fan, any Make & any Sweep Oiling, Greasing , removing all dust with painting and Rewinding of fan by super ennameled copper insulated wire as per existing gauge, varnishing, heating assembling and testing for serviceable condition complete all as directed by Engineer-in-Charge.
S&F in repairs LED tube rod for LED Tube light fitting 18 Watt , complete with all accessories complete all as required at site and as directed by Engineer -in-Charge. Make : Cat No BLRB 20 CW LED of Bajaj or equivalent of Havell's/Philips / Wipro
S&F in repairs Batten for LED Tube light 18 Watt fitting prewireed upto terminal block complete with all accessories and connecting up with twin core / .0076 flexible copper wire with and including LED tube light fixed on two nos PVC round / square mounting blocks complete all as required at site and as directed by Engineer -in-Charge. Make : Cat No BLRB DB 118 of Bajaj or equivalent of Havell's/Philips / Wipro .
S&F in repairs Surface mounted 36 watt 2 x 2 luminaire white powder coated CRCA housing with LEDs, Aluminium front frame with flat white high transmission acrylic cover complete with LEDs, driver and standard accessories including neccessary fixing arrangement complete all as required at site and as directed by Engineer -in-Charge. Cat No BCTBLR 36W LED FP CW of Bajaj or equivalent to Philips /CG.
Supply & fix in repairs 45 W pressure die cast aluminium housing LED Building light secondary optics IP 66 protection including connection with two core twisted copper flexible cable, Make - Bajaj, Cat No - ENXT P 54L WH CR PC SD or equivalent make of Havells /Philips/CG
Supply and fix in replacement of LED Tube light of 18/20 watt (4') with batten integrated channel complete with all accessories pre-wired and including connecting up with twin core twisted flexible copper conductor cable with suitable size complete all as specified and as directed.Make:Bajaj CAT Part No BCLAB 20W WH LED P (4ft) or equivalent to CG/Philips/Wipro complete all as specified and directed .
Supply and fix in replacement of LED Tube light of 10 watt (2') with batten integrated channel complete with all accessories pre-wired and including connecting up with twin core twisted flexible copper conductor cable with suitable size complete all as specified and as directed.Make:Bajaj CAT Part NoBCLSB 10 WH (2ft) or equivalent to CG/Philips/Wipro complete all as specified and directed .
S&F in replacement vertical type DB , (VTPN) suitable for and including MCCB 4 pole, 125 amps, 16KA as incoming (compact) Earth and neutral bus bar of capacity upto 200 amp 4 ways,IP 43 protection , shrouded neutral bar & pan assembly with flexible connecting link in the wall with suitable nut and bolt including matching the existing surface all as specified and directed ,
S&F in replacemen MCB DB SPN 4 ways double door with 240 Volt, 200 amps rated bus bar with all accessories flush in the wall including matching the existing surface all as specified and directed
S&F in replacemen MCB DB SPN 8 ways double door with 240 Volt, 200 amps rated bus bar with all accessories flush in the wall including matching the existing surface all as specified and directed
S&F in repairs MCB DB SPN 12 ways double door with 240 Volt, 200 amps rated bus bar with all accessories flush in the wall including matching the existing surface all as specified and directed
S&F in repairs MCB C Curve SPN 40-63 amps, 240 Volts, Complete all as specified and directed.
S&F in repairs MCB C Curve SP 6 to 32 amps single pole 240 Volts, Complete all as specified and directed.
S&F in repairs MCCB FP 160 Amps 36 kA 415 V , with adjustable thermal and adjustable magnetic release, Complete all as specified and directed.
S&F in repairs MCCB FP 200 Amps 36kA 415 V , with adjustable thermal and adjustable magnetic release, Complete all as specified and directed.
Taking down sub main wiring of any size from the ceiling, walls etc and incl making good to disturb surface of wall and match with the existing surface.
M&L for sub main wiring drawing through PVC casing and capping with two single core 4 sq mm and one run of 4 sq mm as earth wire of stranded copper conductor PVC insulated and unsheathed cable of 1100 volts grade all as directed. Note:- Three run of 4 sqmm wire and One run of PVC casing caping will be measured as one running meter.
M&L for sub main wiring drawing through PVC casing and capping with four runs of single core 6 sq mm and two runs of 6.0 sq mm as earth wire of stranded copper conductor PVC insulated and unsheathed cable of 1100 volts grade all as directed.Note:- Four run of 6 sqmm wire and Two run of 6 sqmm wire and One run of PVC casing caping will be measured as one running meter.
Supply and fix in repairs Triple pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB of rating upto 32 Apms
Supply and fix in repairs Single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB of rating upto10/20 Apms
M&L for earthling complete with galvanized GI earth plate electrode of size 600x600x6.00 mm, buried directly in ground (earth pit not less than 2.25 mtr below normal ground level) with top edge of earth plate not less than 1.5 mtr below normal ground level connected to galvanized earth lead wire 4.0 mm dia by means of volts, nuts, check nut and galvanized iron or steel including earth work in any type of soil, charcoal salt 15 cm around the earth plate as shown in electrical plate No 3 of SSR part1991,20 mm dia watering pipe medium grade 1.50 mtr long GI protection pipe light grade 15 mm dia from earth pit to main board (NOTE:- maximum length of GI protection pipe with each earth shall not be less than 7.5 mtrs) including necessary pit with cover , including testing on complition.
Supply and fix new adore LED lamp 5 Watt confirming to Cat No LhLDeroemD9X005 of Havell's or euivalent in Philips / Bajaj
Supply and fix new adore LED lamp 9 Watt confirming to Cat No LhLDeueCnL8r009 of Havell's or euivalent in Philips / Bajaj
Supply and fix new adore LED lamp 15 Watt confirming to Cat No LhLDeueCnL9r015 of Havell's or euivalent in Philips / Bajaj
Dismantling the existing energy Meters, MCCB / MCB Distribution boards by disconnecting the eletric supply connection and refixing at new or same location after carrying out repairs / replacement , reconnecting complete all as directed by EIC at site.
Supply and fix in repairs modular switch one way 6 Amps, 1 module complete all as specified and as directed.
Supply and fix in repairs modular socket 6 Amps, 2/3 pin combined 2 module complete all as specified and as directed.
Supply and fix in repairs modular socket 6 Amps/16 Amps, 2/3 pin combined 2 module complete all as specified and as dirceted.
Supply and fix in repairs modular switch 1 way 16 Amps, 1 module complete all as specified and as directed.
Supply and fix in repairs modular bell push 6 Amps, 1 module complete all as specified and as directed.
Supply & fix LED Highbay luminaire 60 Watt along with fixture, complete all as specified and directed at site.Make:Bajaj CAT Part No.BJFL 60W LED I or equivalent to CG/Philips/Wipro complete all as specified and directed.
Supply and fix in replacement Electronic ballast suitable for 1x36/40 Watt tube light fitting complete all as specified and as directed.
Supply and fix in replacement Electronic ballast suitable for 1x18/20 Watt tube light fitting complete all as specified and as directed.
Supply and fix in replacement Electronic ballast suitable for 1x28 Watt tube light fitting complete all as specified and as directed.
Excavatioin in trenches not exceeding 1.5 m wide and not exceeding 1.5 m in depth and taking out soft/loose soil for laying of cable /erection of pole/stay pit excavation
All as per Sl item No 50 herein before but in hard/dence soil
M&L for crushed stone sand for cable cushoining laid in trenches for protection of cable
M&L for Returning and filling including spreading levelling watering and well ramming in layers not exceeding 25 cm
M&L for Removing excavated material not exceeding 50 m and depositing where directed at a level not exceeding 1.5 m above the starting point
Supply and laying factory cast, unreinforced precast concrete cable cover factory made embossed the mark “LT CABLE” class LV type1 flat size 250x150x40 mm laid in trenches as specified and as directed.
Taking out under ground 1.1 KV (E) Grade LT cable of size upto 35sqmm 3.5 Core from pole/trenches/walls / ducts etc., for carrying out repairs , relaying, rerouting, laying back through same / different route after carrying out repair / issue under schedule of credit all as directed by Engineer-in-Charge at site.
All As per Sl Item No 56 Herein before but of size 50 Sqmm to 95 Sqmm 3.5 Core
All As per Sl Item No 56 Herein before but of size 120 Sqmm to 185 Sqmm x 3.5 Core
Supply laying and testing cable XLPE insulated screened beded,galvanized steel trip or wire armoured, electric power cables (heavy duty) 1100 Volt grade wiyh stranded aluminium conductor of size 25 sq mm 3,1/2 core. Including taking down old unserviceable cable any size by dismantling of all electrical connection etc all as diercted.
All as per item no 59 above but of size 50 sq mm 3,1/2 core.
All as per item no 59 above but of size 70 sq mm 3,1/2 core.
All as per item no 59 above but of size 185 sq mm 3,1/2 core.
Supply and fix in repair indoor type cable end termination joint heat shrinkable type for 22 KV (E) Grade HT cable of size 120 sqmm x 3 Core to 240 Sqmm x 3 Core and connecting the cable with the load and testing complete all as specified and as directed by Engineer-in-Charge at site. Make- Denson, Raychem, M-Seal
M&L for removing / dismantling existing burnt / defective 22 KV (E) Grade HT straight through joint and providing new straight through joint heat shrinkable type for 22 KV (E) Grade HT XLPE cables of size120 sqmm x 3 Core to 240 Sqmm x 3 Core Sqmm complete all as specified and as directed by Engineer-in-Charge at site.
Supply and fix cable jointing kit for 1.1 KV grade cable for straight through joint complete with Jointing material heat Shrink type and accessories suitable for 3 ½ / 4 core XLPE, armoured, Al conductor cable of size 25 to 50 sqmm,Indoor/Outdoor type
All as per item No 65 above but for cable of size 70 to 95 sq mm.
All as per item No 65 above but for cable of size 185 sq mm.
M&L for earthling complete with galvanized GI earth plate electrode of size 600x600x6.00 mm, buried directly in ground (earth pit not less than 2.25 mtr below normal ground level) with top edge of earth plate not less than 1.5 mtr below normal ground level connected to GI strip using 32x6mm galvanised iron strip, means of volts, nuts, check nut and galvanized iron or steel including earth work in any type of soil, charcoal salt 15 cm around the earth plate as shown in electrical plate No 5 of SSR part1991,20 mm dia watering pipe medium grade 1.50 mtr long GI protection pipe light grade 15 mm dia from earth pit to main board (NOTE:- maximum length of GI protection pipe with each earth shall not be less than 7.5 mtrs) including necessary pit with cover.
M&L for providing stone aggregate 40 mm for substation premises including cleaning of substation complete all as specified and as directed at site by Engineer in Charge .
M&L for Filteration and dehydration of transformer oil through filteration and dehydration machine by means of continuous circulation of transformer oil through filteration and dehydration machine till dielectric strength of the oil is achieved up to 50 KV for one minute at 4 mm gap and oil is completely filtered. Note: 1.Oil samples are to collected from top and bottom of oil tank and test results to be submitted for each sample before and after filteration.
Supply and topping up /replacement of new transformer oil of dielectric strength 50 KV at 4mm gap in transformers conforming to IS - 335 / 1983 of various cap installed in various locations . Make of Transformer oil: Power Oil / Indian Oil / Apar Note : New Transformer oil in the transformer will be filled in the transformer only after filteration and dehydration of existing transformer oil of the transformer. (b) Transformer oil shall be supplied in sealed barrel with test result and test cert.
M&L for disconnection of electric supply, dismantling the top cover, carefully, taking out old gasket and replacement of the same with and including new cork sheet, cleaning of the conservator tank, breather assembly, replacement of silica gel, oil level looking glass, bushings, gasket, nuts, bolts, washers etc. including connecting up complete for Tranformers 22 / 0.433 kV of different capacities all as directed by Engineer-in-Charge. Note: Spares required for replacement will be measured and paid separately under respective item except 6 mm thick tope cover cork sheet gasket.
M&L for Scrubing of old rusted paint from transformer and preparation of surfaces for fresh painting. Painting of transformer by means of spray painting with two coats of synthetic enamel paint of approved colour of transformer up cap 25 KVA to 315 KVA and writing SM NO/MES NO of the transformer.
Supply only S/S Nut, bolts, washers of required sizes.
M&L for scrubbing down the old patchy / blistered paint of the outdoor type LT Panel / feeder Pillar Box of size not exceeding 2.5mtr x 2.5 Mtr x 0.60 Mtr and painting all the metal parts inside and outside of doors with two coats of synthetic enamel paint of approved colour over a coat of red oxide primer after carrying out repairs / replacement to the door hinges ./ locks, welding the broken doors complete all as directed by Engineer-in Charge at site.
M&L for removing the old burnt out wires, cleaning the panel compartments, cleaning the contacts with CTC spray, carrying out repairs to the old unsv burnt out control wiring / panel wirng of the LT Pane;l / feeder Pillar with copper conductor cable provided with multistranded copper conductor cable terminated with thimbles / lugs, connecting up complete all as directed by Engineer-in Charge at site.
S&F in replacement of MCCB 415 Volt 16 KA, 4 Pole 63 Amps capacity. Complete all as specified and directed by Engineer-In-Charge. Make:ABB/Siemens/Hager.
All as per item No. 77 above but 160A, 25KA. Complete all as specified and directed by Engineer-In-Charge.
All as per item No. 77 above but 250A, 36KA. Complete all as specified and directed by Engineer-In-Charge.
All as per item No. 77 above but 315A, 36KA. Complete all as specified and directed by Engineer-In-Charge.
M& L for disconnection of electric supply and earthing connections, sealing the ends, transporting the transformer to civil workshop, dis-assembling into various components, lifting the core and winding, dismantling the core, removing burnt winding, reassembling / laminating the core, rewinding of the burnt out / unserviceable winding on secondary HT side only for all the three phases, varnishing with insulating varnish of approved / specified thickness, baking / drying out in oven for apropriate time, reassembling the transformer complete with and including replacement of HT/LT Bushings, 6 mm thick cork sheet for bushings, top cover gasket, carrying out HV/LV/ Insulation/ Impedance/Loss test ex-factory as per latest IS, transporting back to MES installation, carrying out precommissioning test, and connecting up complete all for satisfactory functioning of the transformer all as specified and directed by E-in-Charge at site for 22/0.433 KV transformers of capacity upto 315 KVA
S&F HT 22 KV Barrel fuses of capacity 15 Amps complete all as specified and as directed.
All as per item no 82 but for 10 Amp
M&L for defect rectification HT/LT cable laid in trenches by locating fault with the help of electronic fault locating machine comprising of surge generator pulse, ECHO fault locator with high frequency distance calculator etc.including and additional excavation in normal alluvial strata required for exposing the cable fault ; removal of deteriorated portion of cable treating of cable and keeping the same ready for jointing work for cable of size up to 240 Sq mm 3 core & LT cable of size upto 240 Sqmm. The fault locating equipments will be brought to site within the hours of instruction from Engr-in-Charge as specified
Supply laying and testing cable XLPE insulated screened PVC beded,galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volt grade with stranded aluminium conductor of size 25 sq mm 4 core. Including taking down old unserviceable cable any size by dismantling of all electrical connection etc all as specified and diercted.
All as per item no 85 above but of size 16 sq mm 4 core.
Supply and fix FR PVC insulated cable 1100 V grade with multistranded copper conductor of size 1.5 Sqmm 3 core conductor all as s specified and directed by Engineer-In -Charge at site
Supply & fix in replacement of LED street light of 70 watt along with fixture.Make:Bajaj CAT Part No ENXT P 84L WH CR PC SD or equivalent to CG/Philips/Wipro complete all as specified and directed
Supply & fix in replacement of LED Flood Luminaire of 100 Watt (MAGNUM) with high pressure die cast aluminium housing with IP 65 Protection .Make:Bajaj CAT Part No BJFL 100W LED S or equivalent to CG/Philips/Wipro complete all as specified and directed
Supply & fix in replacement of SPD up to 50 KA complete all as specified and as directed .Make:Bajaj or equivalent to CG/Philips/Wipro.
Supply & fix in replacement of LED DRIVER for 45 to 150 watt street light fitting complete all as specified and as directed .Make:Bajaj or equivalent to CG/Philips/Wipro.
Taking down streetlight fitting / security lights / Building any type from pole /wall and refix the same in its own position including repair and replacement of unserviciable parts and testing complete . NOTE :-(i) Spares required to be replaced will be measured and paid separatel under respective item of Sch A. (ii) Rates quoted shall be deemed to include the cost of minor spares not catered for in the subject CA.
Dismantling the unserviceable stator coil assembly from the 62.5 KVA DG Set Alternator transporting the same to the workshop to carry out the following repairs:- (a) Stripping down the old burnt copper winding and rewinding the same with same size of super enameled copper wire, replacing the insulation paper sheet after properly cleaning the slots and providing appropriate impregnated insulation material including varnishing the complete assembly with class 'E' insulation and baking the same in an oven, reassembling and refixing stator cover with new nut bolts transporting and installing the repaired equipments to the site with final testing complete all as specified. (b) Removing the old unserviceable terminal box connecting wires with lugs and refixing with new terminal box with connecting wires and copper lugs and terminal nut bolts (c ) Removing the unserviceable RRA Diode assembly and Coupling rubber bush and providing the new rubber coupling bush complete all as specified. (d) Replacement of shaft seal of drive shaft. (e) Repair/Replacement of Voltage control unit (AVR) including necessary repair and also replacement of rectifier and testing complete (f) Removing the fuel injector Pump from the engine, for servicing, overhauling including replacement of 'O' Rings and Washers and reassembling/refixing in position and testing. Also servicing the fuel injectors and replacing the washers and 'O' Rings reassembling and calibration of fuel injector and refixing in position and testing complete all as specified and directed.
Replacement of old UNSV filters wth new filters with rubber 'O' ring complete all as specified following DG Sets:- (a) 62.5 KVA (Air Force / Tropo) (i) Fuel Filter
(ii) Lub Oil Filter
(iii) By pass oil filter
(iv) CR filter plate & 'O' ring
(v) Air filter (inner and outer)
M&L for dismantling of radiator complete from DG Sets cleaning / scraping from outside of the radiator, cleaning of all copper tubes of radiator with descalling solution from inside & out side with forced feed method (by using separate chemical pump, water pump & compressor) also plugging of all leakage by welding, brazing of copper tubes, cleaning of fins and replacement of gaskets etc for the following capacities of DG Sets:- (a) 62.5 KVA
S & F and topping up of lubricant oil of various capacity of DG sets at various location under GE (I) (Navy) Lonavla complete as as specified and directed by Engr-in-Charge (Note - 1. Old decanned oil included in the credit schedule)
M&L for cleaning of Sump including replacement of sump gasket of the following capacities of DG Sets:- (a ) 62.5 KVA
S & F 150 AH 12V battery of Maintenance free suitable for DG sets as fixed in repairs complete all as specified and directed by Engr-in-Charge Make - Exide / Amron / Cummins / Greaves Cotton / Luminous
SHAILENDRA B TULSANI
United Engineers and Contractors
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .