Loading…
Loading…
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance | Admitted-Finance |
| 2 | Admitted-Finance | Admitted-Finance |
| 3 | Rejected-Technical BATOTE | KATHUA | JAMMU AND KASHMIR | 184143 | Rejected-Technical not qualified |
Tender Value
₹33 L
EMD Value
₹66,000
Closing Date
8 Jan 2024, 2:00 pmClosed
Executive Engineer Electric division JPDCL batote
Office of the Executive Engineer Elect Division Batote
Supply ErectionTesting andCommissioning for creation of 3x100 KVA substation along with HTLT network for PHE lift schemes under JJM at Gund Adalkote near Doligam Nallah, Dalwah Upper StageI and Sangaldan StageII under the jurisdiction of Electric D
2023_PDD_240164_1
e NIT No 50 of 2023-24
Open Tender
Electrical Works
Turn-key
60 days
Various locations at Ramban
Please refer Tender Document
4 documents required · 4 mandatory
₹5,000
Yes
Executive Engineer Electric division JPDCL batote
₹66,000
Yes
20 Jan 2024
15 Dec 2023
9 Jan 2024
15 Dec 2023
8 Jan 2024
15 Dec 2023
Amount
Creation of 100 KVA sub-station along with HT/LT network for PHE lift schemes under JJM at Gund Adalkote near Doligam under the jurisdiction of Electric Division, Batote on Turnkey Basis
11/0.433KV, 3-phase Copper wound 100 KVA Distribution Transformers with Bimetallic Terminal Connectors Energy Level-2, , and with LV Cable Box having detachable Aluminium Gland plate
Gapless Surge Arrestor,9 KV ,10 KA ,LA with (polymer/porcelain) housing, Stn. Type
11 kV G.O AB Switch , 3-phase, 3 pole 200 Amp. Vertical type
11 kV Horn Gap Fuse Set 3 Phase 3 pole, 200 Amp
185 mm² (2Ckt) Cable, 1.1kV Grade, PVC Insulated Stranded Conductor FRLS type
9 Mtr. Long Pole( ST-540 SP33)
11kV Polymeric composite Disc Insulator 12kV,min failing load 45kN, Lighting Impulse 75kV Positive and 80kV Negative, creepage distance 320mm
GI Channel/Angle/Flat of sizes including clamps
Galvinized Nuts and Bolts.
Earthing of Sub-station
32/100 amps TPN Switch Disconnector Fuse set
11kV Polymeric composite Pin Insulator 12kV, 5kN, Lighting Impulse 75kV Positive and 80kV Negative, creepage distance 320mm
LT Distribution Box with 100 Amps 3 Pole outdoor MCCB
Prodigy Meter trivector meter with CT
Galvanised Stay Set with 50x8mm stay clamp, guy insulator(2Nos.),anchor plate (200x 200 x 6 mm), nut-bolts, 2 Nos turn-buckles, 1.8m long, 16 mm diameter solid GS stay rod & 7/3.15 mm dia GI stranded wire complete
Danger Plates with Clamps
GI Barbed Wire for Anti Climbing
Cement bottoming 1:2:4 mix as per REC standards .5cum /pole
Painting of Poles Red Oxide
Painting of Poles Aluminium Paint
Sundry items like aluminium lugs, Jumpers, binding Tape
Wedge Connectors/PG Clamps
ST POLES (09 MTR.) LONG
ACSR WEASEL CONDUCTOR
11 KV DISC INSULATORS WITH FITTINGS
11 PIN INSULATOR WITH PINS
GI V cross-arm with top Bracket including clamp
GI Channel X-arm including clamps and braces
Galvanized NUTS & BOLTS
GI Barbed Wire for Anti Climbing
Cement bottoming 1:2:4 mix as per REC standards .5cum /pole
Danger Plates with clamps
Painting of Poles Red Oxide
Painting of Poles Aluminium Paint
Galvanised Stay set
Suspension/Tension clamps with eye hook
Mid Span straight through jointing kit for 11KV ABC
ST POLES (08 MTR.) LONG
LT PVC 3.5 Core Armoured 120 mmsq Cable
ACSR WEASEL CONDUCTOR
Shakle Insulator
Clamps for Shackle insulators
PG Clamps
NUTS & BOLTS(galvanized)
GI Barbed Wire for Anti Climbing
Painting of Poles Red Oxide
Painting of Poles Aluminium Paint
CREATION OF 100 KVA SUB-STATION ALONG WITH HT/LT NETWORK FOR PHE LIFT SCHEMES UNDER JJM AT DALWAH(Stage- Ist).
11/0.433KV, 3-phase Copper wound 100 KVA Distribution Transformers with Bimetallic Terminal Connectors Energy Level-2, , and with LV Cable Box having detachable Aluminium Gland plate
Gapless Surge Arrestor,9 KV ,10 KA ,LA with (polymer/porcelain) housing, Stn. Type
11 kV G.O AB Switch , 3-phase, 3 pole 200 Amp. Vertical type
11 kV Horn Gap Fuse Set 3 Phase 3 pole, 200 Amp
185 mm² (2Ckt) Cable, 1.1kV Grade, PVC Insulated Stranded Conductor FRLS type
9 Mtr. Long Pole( ST-540 SP33)
11kV Polymeric composite Disc Insulator 12kV,min failing load 45kN, Lighting Impulse 75kV Positive and 80kV Negative, creepage distance 320mm
GI Channel/Angle/Flat of sizes including clamps
Galvinized Nuts and Bolts.
Earthing of Sub-station
11kV Polymeric composite Pin Insulator 12kV, 5kN, Lighting Impulse 75kV Positive and 80kV Negative, creepage distance 320mm
32/100 amps TPN Switch Disconnector Fuse set
LT Distribution Box with 100 Amps 3 Pole outdoor MCCB
Prodigy Meter
Galvanised Stay Set with 50x8mm stay clamp, guy insulator(2Nos.),anchor plate (200x 200 x 6 mm), nut-bolts, 2 Nos turn-buckles, 1.8m long, 16 mm diameter solid GS stay rod & 7/3.15 mm dia GI stranded wire complete
Wedge Connectors/PG Clamps
Danger Plates with Clamps
GI Barbed Wire for Anti Climbing
Cement bottoming 1:2:4 mix as per REC standards .5cum /pole
Painting of Poles Red Oxide
Painting of Poles Aluminium Paint
Sundry items like aluminium lugs, Jumpers, binding Tape
ST POLES (09 MTR.) LONG
ACSR WEASEL CONDUCTOR
11 KV DISC INSULATORS WITH FITTINGS
11 PIN INSULATOR WITH PINS
GI V cross-arm with top Bracket including clamp
GI Channel X-arm including clamps and braces
NUTS & BOLTS
GI Barbed Wire for Anti Climbing
Cement bottoming 1:2:4 mix as per REC standards .5cum /pole
Painting of Poles Red Oxide
Painting of Poles Aluminium Paint
Galvanised Stay set
11KV Link Set
ST POLES (08 MTR.) LONG
ACSR WEASEL CONDUCTOR
Shakle Insulator
Clamps for Shackle insulators
NUTS & BOLTS
GI Barbed Wire for Anti Climbing
Cement bottoming 1:2:4 mix as per REC standards .5cum /pole
Painting of Poles Red Oxide
Painting of Poles Aluminium Paint
CREATION OF 100 KVA SUB-STATION ALONG WITH HT/LT NETWORK FOR PHE LIFT SCHEMES UNDER JJM AT Sangaldan (Stage -Iind)
11/0.433KV, 3-phase Copper wound 100 KVA Distribution Transformers with Bimetallic Terminal Connectors Energy Level-2, , and with LV Cable Box having detachable Aluminium Gland plate
Gapless Surge Arrestor,9 KV ,10 KA ,LA with (polymer/porcelain) housing, Stn. Type
11 kV G.O AB Switch , 3-phase, 3 pole 200 Amp. Vertical type
11 kV Horn Gap Fuse Set 3 Phase 3 pole, 200 Amp
185 mm² (2Ckt) Cable, 1.1kV Grade, PVC Insulated Stranded Conductor FRLS type
9 Mtr. Long Pole( ST-540 SP33)
11kV Polymeric composite Disc Insulator 12kV,min failing load 45kN, Lighting Impulse 75kV Positive and 80kV Negative, creepage distance 320mm
GI Channel/Angle/Flat of sizes including clamps
Galvinized Nuts and Bolts.
32/100 amps TPN Switch Disconnector Fuse set
11kV Polymeric composite Pin Insulator 12kV, 5kN, Lighting Impulse 75kV Positive and 80kV Negative, creepage distance 320mm
LT Distribution Box with 100 Amps 3 Pole outdoor MCCB
Prodigy Meter trivector meter with CT
Galvanised Stay Set with 50x8mm stay clamp, guy insulator(2Nos.),anchor plate (200x 200 x 6 mm), nut-bolts, 2 Nos turn-buckles, 1.8m long, 16 mm diameter solid GS stay rod & 7/3.15 mm dia GI stranded wire complete
Wedge Connectors/PG Clamps
GI Barbed Wire for Anti Climbing
Danger Plates with Clamps
Cement bottoming 1:2:4 mix as per REC standards .5cum /pole
Painting of Poles Red Oxide
Painting of Poles Aluminium Paint
Sundry items like aluminium lugs, Jumpers, binding Tape
ST POLES (09 MTR.) LONG
ACSR WEASEL CONDUCTOR
11 KV DISC INSULATORS WITH FITTINGS
11 PIN INSULATOR WITH PINS
GI V cross-arm with top Bracket including clamp
GI Channel X-arm including clamps and braces
NUTS & BOLTS(Galvanized)
GI Barbed Wire for Anti Climbing
Cement bottoming 1:2:4 mix as per REC standards .5cum /pole
Painting of Poles Red Oxide
Painting of Poles Aluminium Paint
Galvanised Stay set
11KV Link Set
ST POLES (08 MTR.) LONG
LT PVC 3.5 Core Armoured 120 mmsq Cable
ACSR WEASEL CONDUCTOR
Shakle Insulator
Suspension/Tension Clamp
Insulating piercing Connectors
NUTS & BOLTS(Galvanized)
GI Barbed Wire for Anti Climbing
Cement bottoming 1:2:4 mix as per REC standards .5cum /pole
Painting of Poles Red Oxide
Painting of Poles Aluminium Paint
GIRI ELECTRICAL & SONS
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .