| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L3₹1.6 Cr+₹24.2 L (14.5%)Accepted-AOC | ₹1.6 Cr+₹24.2 L (14.5%) Quoted ₹1.9 Cr | L3 | Accepted-AOC AOC |
| 2 | L1₹1.7 CrRejected-Finance | ₹1.7 Cr | L1 | Rejected-Finance REJECT |
| 3 | L2₹1.9 Cr+₹22.1 L (13.2%)Rejected-Finance | ₹1.9 Cr+₹22.1 L (13.2%) | L2 | Rejected-Finance REJECT |
| 4 | L4₹2.0 Cr+₹36.0 L (21.6%)Rejected-Finance | ₹2.0 Cr+₹36.0 L (21.6%) | L4 | Rejected-Finance REJECT |
| Sl No | Description | Qty | Unit | CHIRAYU POWER PVT LTD L1 | Ecoteam Solar Pvt Ltd L2 | Heramb Industries L4 | CORPORATE RENEWABLES PRIVATE LIMITED L3 |
|---|---|---|---|---|---|---|---|
| 1.00PART (A) : DESIGN & SUPPLY OF THE FOLLOWING: | |||||||
| 2.00 | A.1-- SPV system complete with PV modules (minimum 590 Wp TOPCon cell) installed in array with Modular Mounting Structure (MMS) complete on Ground as per site requirements. Capacity/ size-- 450KW | 1 | Set | 94,36,000 ₹94,36,000 | 89,00,000 ₹89,00,000 | 70,87,500 ₹70,87,500 Lowest | 70,87,500 ₹70,87,500 Lowest |
| 3.00 | A.2--Invertor complete with safeties & protection Capacity/ size-- 450 KW | 1 | Set | 25,00,000 ₹25,00,000 | 17,00,000 ₹17,00,000 | 9,45,000 ₹9,45,000 Lowest | 9,45,000 ₹9,45,000 Lowest |
| 4.00 | A.3--Solar meter & CT with testing Capacity/ size-- As per site requirement | 1 | Lot | 3,00,000 ₹3,00,000 | 5,00,000 ₹5,00,000 | 2,36,000 ₹2,36,000 Lowest | 2,36,000 ₹2,36,000 Lowest |
| 5.00 | A.4-- DC cables (6 sq. mm, Copper), cable trays, supports, conduits etc Capacity/ size-- As per site requirement | 1 | Set | 8,22,000 ₹8,22,000 | 6,00,000 ₹6,00,000 | 5,90,000 ₹5,90,000 Lowest | 5,90,000 ₹5,90,000 Lowest |
| 6.00 | A.5-- AC Cable - (Size as per SLD)(Copper conductor, GI armoured, XLPE/HR PVC insultaed, 1.1 KV grade cable., - Length shall be as per site requirement between Inverter to AC Isolator box, including cable trays in buildings & outside buildings, necessary MS supports, etc as per site requirement. Capacity/ size-- | 1 | Lot | 44,250 ₹44,250 Lowest | 9,00,000 ₹9,00,000 | 9,44,000 ₹9,44,000 | 9,44,000 ₹9,44,000 |
| 7.00 | A.6-- AC Cable For Solar PV System - (Size as per SLD), Aluminium conductor, GI armoured XLPE/HR PVC insultaed, 1.1 KV grade cable., - Total length (tentative cable route shown in site layout) as per site requirement between each Inverter Isolator Box to LT Power Distribution Panel and existing LT PCC , including cable trays in buildings & outside buildings, necessary MS supports, etc as per site requirement. Capacity/ size-- As per site requirement | 1 | Lot | 5,19,200 ₹5,19,200 Lowest | 9,00,000 ₹9,00,000 | 14,16,000 ₹14,16,000 | 14,16,000 ₹14,16,000 |
| 8.00 | A.7-- Chemical Earthing system, with solid copper bonded rods (minimum 250 microns coating thickness), copper earth strips, Copper earth electrodes, lightning arrestor etc. Capacity/ size-- As per site requirement | 1 | Lot | 78,000 ₹78,000 Lowest | 3,50,000 ₹3,50,000 | 2,95,000 ₹2,95,000 | 2,95,000 ₹2,95,000 |
| 9.00 | A.8-- Remote monitoring system, Weather station (Solar irradiation sensor, wind velocity meter, Ambient temperature sensor) As per site requirement | 1 | Set | 2,00,000 ₹2,00,000 Lowest | 2,40,000 ₹2,40,000 | 4,13,000 ₹4,13,000 | 4,13,000 ₹4,13,000 |
| 10.00 | A.9-- Bidirectional meter and Solar Check meter (11 KV) with CT, PT units as per Local Electricity board requirement. Necessary testing & liaison with MSEDCL/ CEIG /MEDA and obtaining approvals are included in the scope of work. Capacity/ size-- As per site requirement | 1 | Set | 3,00,000 ₹3,00,000 | 90,000 ₹90,000 Lowest | 2,95,000 ₹2,95,000 | 2,95,000 ₹2,95,000 |
Tender Value
Refer Docs
EMD Value
₹2 L
Closing Date
3 Jan 2026, 5:00 pmClosed
Managing Director CSCMPUL Sambhajinagar
Gandheli Dairy Plant, Gut No. 97, Po. Aadgaon Tal. and Dist. Chhatrapati Sambhajinagar
Design,Manufacture, Supply,Transport, Installation,Testing and Commissioning with 5 Years Comprehensive Maintenance Contract (CMC) of 450 kWp grid connected Solar Photovoltaic (SPV) System (Net Meter)At Gandheli Dairy Plant,Gut No.97 Turnkey basis
2025_ACMPU_1261880_1
E Tender/Notice 8/ Recall/2025-26
Open Tender
Hiring of Goods
Item Rate
120 days
at Gandheli Dairy Plant Chh Sambhajinagar
Please refer Tender documents.
4 documents required · 4 mandatory
₹10,000
₹2 L
at Gandheli Dairy Plant Chh Sambhajinagar
11 Sept 2026
20 Dec 2025
5 Jan 2026
20 Dec 2025
3 Jan 2026
20 Dec 2025
24 Dec 2025
PART (A) : DESIGN & SUPPLY OF THE FOLLOWING:
A.1-- SPV system complete with PV modules (minimum 590 Wp TOPCon cell) installed in array with Modular Mounting Structure (MMS) complete on Ground as per site requirements. Capacity/ size-- 450KW
A.2--Invertor complete with safeties & protection Capacity/ size-- 450 KW
A.3--Solar meter & CT with testing Capacity/ size-- As per site requirement
A.4-- DC cables (6 sq. mm, Copper), cable trays, supports, conduits etc Capacity/ size-- As per site requirement
A.5-- AC Cable - (Size as per SLD)(Copper conductor, GI armoured, XLPE/HR PVC insultaed, 1.1 KV grade cable., - Length shall be as per site requirement between Inverter to AC Isolator box, including cable trays in buildings & outside buildings, necessary MS supports, etc as per site requirement. Capacity/ size--
A.6-- AC Cable For Solar PV System - (Size as per SLD), Aluminium conductor, GI armoured XLPE/HR PVC insultaed, 1.1 KV grade cable., - Total length (tentative cable route shown in site layout) as per site requirement between each Inverter Isolator Box to LT Power Distribution Panel and existing LT PCC , including cable trays in buildings & outside buildings, necessary MS supports, etc as per site requirement. Capacity/ size-- As per site requirement
A.7-- Chemical Earthing system, with solid copper bonded rods (minimum 250 microns coating thickness), copper earth strips, Copper earth electrodes, lightning arrestor etc. Capacity/ size-- As per site requirement
A.8-- Remote monitoring system, Weather station (Solar irradiation sensor, wind velocity meter, Ambient temperature sensor) As per site requirement
A.9-- Bidirectional meter and Solar Check meter (11 KV) with CT, PT units as per Local Electricity board requirement. Necessary testing & liaison with MSEDCL/ CEIG /MEDA and obtaining approvals are included in the scope of work. Capacity/ size-- As per site requirement
A.10-- Spares, tools, meters Capacity/ size--
PART (B) : Installation, Testing and Commissioning
B.1-- SPV system complete with PV modules (minimum 590 Wp TOPCon cell) installed in array with MMS complete on Ground as per site requirements. Capacity/ size-- 450KW
B.2-- -Invertor complete with safeties & protection Capacity/ size-- 450 KW
B.3-- Solar meter & CT with testing Capacity/ size-- As per site requirement
B.4-- DC cables (6 sq. mm, Copper), cable trays, supports, conduits etc as per site requirement. Capacity/ size--
B.5-- AC Cable - (Size as per SLD)(Copper conductor, GI armoured, XLPE/HR PVC insultaed, 1.1 KV grade cable., - Length shall be as per site requirement between Inverter to AC Isolator box, including cable trays in buildings & outside buildings, necessary MS supports, etc as per site requirement. Capacity/ size-- As per site requirement
B.6-- AC Cable For Solar PV System - (Size as per SLD), Aluminium conductor, GI armoured XLPE/HR PVC insultaed, 1.1 KV grade cable., - Total length (tentative cable route shown in site layout) as per site requirement between each Inverter Isolator Box to LT Power Distribution Panel and existing LT PCC , including cable trays in buildings & outside buildings, necessary MS supports, etc as per site requirement. Capacity/ size--
B--7 Chemical Earthing system, with solid copper bonded rods (minimum 250 microns coating thickness), copper earth strips, Copper earth electrodes, lightning arrestor etc. Capacity/ size-- As per site requirement
B--8 Remote monitoring system, Weather station (Solar irradiation sensor, wind velocity meter, Ambient temperature sensor) Capacity/ size--
B--9 Bidirectional mete r and Solar Check meter (11 KV) with CT, PT units as per Local Electricity board requirement. Necessary testing & liaison with MSEDCL/ CEIG /MEDA and obtaining approvals are included in the scope of work. Capacity/ size-- As per site requirement
B.10-- Civil works complete – like pile foundation, construction of invertor room, Path way, Putting Gravels grouting of bolts/structural members, breaking of wall /floor slab, cut-outs making, finishing, painting, support etc required for the SPV system is included in the scope of work. Capacity/ size--
stage.html
html • 0.05 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.00 MB
TENDERDOCUMENT_Update.pdf
Tender Documents • 2.79 MB
BOQ_2174644.xls
BOQ • 0.25 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .