| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹34.2 LAccepted-AOC 7TH MILE UPPER SHILLONG P O NONGLYER SHILLONG MEGHALAYA | EAST KHASI HILLS | MEGHALAYA | 793009 | L1 | Accepted-AOC Lowest Bidder | |
| 2 | L2₹35.1 L+₹87,460 (2.56%)Rejected-AOC | L2 | Rejected-AOC Not Lowest Bidder | |
| 3 | L3₹36.4 L+₹2.2 L (6.36%)Rejected-AOC 7TH MILE UPPER SHILLONG P O NONGLYER SHILLONG MEGHALAYA | EAST KHASI HILLS | MEGHALAYA | 793009 | L3 | Rejected-AOC Not Lowest Bidder | |
| 4 | L4₹45.9 L+₹11.7 L (34.2%)Rejected-AOC | L4 | Rejected-AOC Not Lowest Bidder |
Tender Value
₹48 L
EMD Value
₹96,000
Closing Date
9 Feb 2023, 6:00 pmClosed
GE(I)(AF) SHILLONG
GE (I) (AF) Shillong Elephant Falls Camp PO Nonglyer Shillong-793009
CA NO GE(I)(AF) SHL/ OF 2022-23 REPAIR/REPLACEMENT OF OLD UNSERVICEABLE ALUMINIUM WIRING/SUBMAIN ALONG WITH CONNECTED DISTRIBUTION BOARD AT CERTAIN PLACES OF BLDG NO. P-251 AT HQ EAC (U) AF UNDER GE(I)(AF) SHILLONG
2023_MES_574257_1
8079/22/SHL/2022/23
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
SHILLONG
For Enlisted Contractors Class D Category b i and for unenlisted contractors meeting enlistment criteria for required Class and Category
8 documents required · 8 mandatory
₹500
GE (I) (AF) SHILLONG
₹96,000
Yes
15 Feb 2023
10 Jan 2023
11 Feb 2023
10 Jan 2023
9 Feb 2023
23 Jan 2023
10 Jan 2023 - 20 Jan 2023
Amount
Note : All unserviceable materials obtained out of demolition/dismantling/taking down (other than those for which credit catered under Schedule of credit) shall be disposed of outside MoD Land. Quoted rates against respective item shall deemed to include for same.
Taking down carefully copper/aluminium point wiring (Light, fan, socket or power) complete from existing conduits, from PVC casing/ capping including fixtures and fittings such as switches, ceiling roses, pendants, regulators, sockets light fittings etc, removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good distrubed surface of wall, floor etc complete all as specified and directed.
Taking down main switch/ DB's including MCB's with board and fixture of any description and making good distured surface of walls etc, removing materials to store for keeping in safe custody or for taking credit complete all as specified and directed.
M&L for point wiring with two run of 1.5 sqmm PVC insulated unsheathed single core FRLS stranded copper conductor cable 1100 volts grade drawn through in metal/PVC concealed conduit of any grade and size for one light/Ex Fan/Call bell point controlled by one switch including One run of 1.5 Sqmm PVC insulated unsheathed single core FRLS stranded copper conductor cable 1100 Volts grade as earth continuity conductor connected to common earth dolly, and to be terminated in new pressed flush metal box suitable for mounting modular type switchs, socket outlets etc, covered with inner/outer plate etc as per requirement at site complete as specified and directed. (Note : The rate quoted shall deemed to incude for cutting chases for concealing PVC conduit and making good distrubed surfaces.)
(a) One light/ Fan point controlled by one, one way switch complete.
(b) One 5 Amps socket outlet/ switch socket outlet on same board with other switches.
(c) One call bell controlled by one bell push complete.
M&L for point wiring complete for 5 Amps socket outlet on independent board with 2.5 Sqmm single core multistranded copper conductor of 1100 volts grade PVC insulated and unsheathed FRLS cable drawn throught existing PVC/metalic conduit of any size and grade inculding sunk type pressed steel terminal boxes (heavy duty) with 3mm thick plastic laminated bakelite sheet top cover for mounting switches, sockets, including 2.5 Sqmm multistarnded copper conductor with green PVC FRLS insulated unsheathed earth continuity conductor to common earth & connnecting to earth dolly. (Note : the rate quoted shall deemed to incude for cutting chases for concealing PVC conduit and making good disturbed surfaces.)
All as per item No.4 here-in-before but with two run 4.00 sqmm PVC insulated unsheathed FRLS stranded copper conductor cable 1100 volts grade and one run of 4 Sqmm single core PVC insulated unsheathed FRLS stranded copper conductor cable 1100 Volts grade as earth continuity conductor. for 5 pin 16 Amps socket point on independent board for gyser/ air conditioner complete all as specified and as directed.
M&L for point wiring with two run of 1.5 sqmm PVC insulated unsheathed single core FRLS stranded copper conductor cable 1100 volts grade drawn through in and including PVC casing capping (ISI Marked) of suitable size for one light/Ex Fan/Call bell point controlled by one switch including One run of 1.5 Sqmm PVC insulated unsheathed single core FRLS stranded copper conductor cable 1100 Volts grade as earth continuity conductor connected to common earth dolly, and to be terminated in new pressed flush metal box suitable for mounting modular type switchs, socket outlets etc, covered with inner/outer plate etc as per requirement at site complete as specified.
(a) One light/ Fan point controlled by one switch complete.
(b) One call bell controlled by one bell push complete.
(c) One socket out let 5A 5pin on same board complete.
M&L for point wiring complete for 5 Amps socket outlet on independent board with 2.5 Sqmm single core multistranded copper conductor of 1100 volts grade PVC insulated and unsheathed FRLS cable drawn throught and inculding PVC casing capping (ISI Marked) in walls/ ceiling/ floors and as per IS inculding sunk type pressed steel terminal boxes (heavy duty) with 3mm thick plastic laminated bakelite sheeet top cover for mounting switches, sockets, including 2.5 Sqmm multistarnded copper conductor with green PVC FRLS insulated unsheathed earth continuity conductor to common earth & connnecting to earth dolly.
All as per item No.7 here-in-before but with two run 4.00 sqmm PVC insulated unsheathed FRLS stranded copper conductor cable 1100 volts grade and one run of 4 Sqmm single core PVC insulated unsheathed FRLS stranded copper conductor cable 1100 Volts grade as earth continuity conductor. for 5 pin 16 Amps socket point on independent board for gyser/ air conditioner complete all as specified and as directed.
M & L for switch piano, flush type single pole, one way 5 Amp complete all as specified and directed.
S & F Bell push, flush type,6 amp 230 volts.complete all as specified and directed.
S&F socket outlet on same board 6Amp 2/3 pin combined AC, 230V complete all as specified and directed.
S&F switch socket combination, 3 Pin 5 Amp AC, 230V, complete all as directed.
S&F switch socket combination, 6 Pin 16 Amp, AC, 230V, complete all as directed.
S&F Buzzer, Ding Dong AC. 230 volts, single pole complete all as directed.
S&F Supply and fixing LED lights fitting 1x 20W, 220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete.
Supply and fixing LED light fitting mirror type with high out put diffuser 2 feet, 10 watt 220 V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size complete.
Supply and fixing LED luminaire 600 mm x 600 mm, 35/36 watt, 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete.
Supply and fixing sheet metal enclosure for DBs sp&N when MCB to be usedsingle pole and neutral double door, 12 way (2 incoming + 10 Outgoing), AC 240Volts with IP 54-lk 09 with series No 507642 complete all as specified and directed.
M&L for wiring for submain/circuit with two run of single core PVC insulated & unsheathed FRLS multi stranded copper conductor cable of size 10 Sqmm 1100 volts grade and one run of PVC insulated & unsheathed FRLS multi stranded copper conductor cable of size 10.00 Sqmm 1100 volts grade as earth continuity conductor drawn through in and including rigid non metallic PVC concealed conduit of suitable size on surface ofwall/ceiling including making good disturbed surfaces of wall etc
All as per item No 18 here-in before but with 6 Sqmm wire and 6 Sqmm wire as earth conductor complete all as specified and directed.
All as per item No 18 here-in-before but with16 Sqmm wire and 16 Sqmm wire as earth conductor.
All as per item No 18 here-in-before but with25 Sqmm wire and 25 Sqmm wire as earth conductor.
S&F MCB 'B' Series single pole, 6 to 32 Amps, 240 Volts 50 HZ, 10 KA breaking cap[acity complete all as directed. Make Havells/ L&T/ Legrand/Indo Asian.
S&F MCB SP 40 Amps 240 Volts, 50 Hz, 10 KA breaking capacity complete all as directed. Make : Havells /L&T/Legrand/ Indo Asian
S&F MCB SPN 40 Amps 240 Volts, 50 Hz, 10 KA breaking capacity complete all as directed. Make Havells L&T/ Legrand/Indo Asian
M&L for cutting chasing, pinning in, making good to facings where required in pointing in cement mortar 1:3 to ends or edge of landing, steps, cills, sunshades etc and cutting chasing for concealed water tubing or concealed conduit wiring etc and making good , cutting not exc 10 cm girth in stone concreate block walls, all as directed.
S&F ceiling rose PVC poly carbonate body three terminals
S&F sheet metal enclosure vertical type double door DB TPN 4 way suitable to accomodate MCCB FP, 415 volts upto 120 Amps rating, protection class IP-43 IK-09 made out of CRCA mild steel sheet surface with insulated material like polyester with epoxy powder coated surface mounted as per IEC 61439-3, with copper bus bar of 250 Amps capacity for each phase, with two neutralbars, two Earth bars and cable ties for cable managementall as specified and as approved by Engineer-in-Charge.
S&F MCCB four pole 125 Amp confirming to IEC 60947-2 thermal magnetic release and rupturing capacity 10 KA at 415 V AC , 50 Hz
Supply and fix indoor type LT wall mounted panel board made out of MS sheet of suitable size comprising following and all as specified with metering instruments and cable alley and cable gland:- (a) Incommer MCCB 4 pole 250 Amps 36 KA (b) Bus bar set of four 250 Amps Aluminium, Digital Current and Volt meter three phase (c) Outgoing MCCB 4 Pole 63 Amps 16 KA for outdoor unit - 3 + ougoing MCCB 4 pole 125 Amps 16KA - 3 (d) Outgoing MCCB 4 Pole 32 Amps 16 KA - 2
S&F MCCB four pole 125 Amp confirming to IEC 60947-2 thermal magnetic release and rupturing capacity 10 KA at 415 V AC , 50 Hz
S&F MCCB four pole 125 Amp confirming to IEC 60947-2 thermal magnetic release and rupturing capacity 10 KA at 415 V AC , 50 Hz
S&F MCCB four pole 63 Amp confirming to IEC 60947-2 thermal magnetic release and rupturing capacity 10 KA at 415 V AC , 50 Hz
S&F MCCB four pole 32 Amp confirming to IEC 60947-2 thermal magnetic release and rupturing capacity 10 KA at 415 V AC , 50 Hz
M&L for XLPE insualted, armoured heavy duty electric cable with aluminium conductor, 1100 Volts grade, cross-sectional area 10 Sqmm with 4.0 Core
M&L for XLPE insualted, armoured heavy duty electric cable with aluminium conductor, 1100 Volts grade, cross-sectional area 25 Sqmm with 3.5 Core
M&L for XLPE insualted, armoured heavy duty electric cable with aluminium conductor, 1100 Volts grade, cross-sectional area 35 Sqmm with 3.5 Core
M&L for XLPE insualted, armoured heavy duty electric cable with aluminium conductor, 1100 Volts grade, cross-sectional area 50 Sqmm with 3.5 Core
M&L for XLPE insualted, armoured heavy duty electric cable with aluminium conductor, 1100 Volts grade, cross-sectional area 10 Sqmm with 4.0 Core
M/S A K C ENTERPRISE
M/S DEEDAR ENTERPRISE
M/S SKYSCRAPER CONSTRUCTION
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .