Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹19.0 LAccepted-AOC | L1 | Accepted-AOC Lowest bidder | |
| 2 | L2₹21.2 L+₹1.6 L (7.90%)Rejected-Finance | L2 | Rejected-Finance Other than lowest bidder | |
| 3 | L3₹21.9 L+₹2.3 L (11.8%)Rejected-Finance C O SECTOR 02 HOUSING COLONY CHANNI HIMMAT JAMMU J K PIN 180015 | JAMMU | JAMMU AND KASHMIR | 180015 | L3 | Rejected-Finance Other than lowest bidder | |
| 4 | L4₹23.6 L+₹4.0 L (20.2%)Rejected-Finance | L4 | Rejected-Finance Other than lowest bidder | |
| 5 | L5₹23.9 L+₹4.2 L (21.6%)Rejected-Finance | L5 | Rejected-Finance Other than lowest bidder |
Tender Value
Refer Docs
EMD Value
₹51,500
Closing Date
28 Dec 2020, 6:00 pmClosed
GE AF JAMMU
GE AF JAMMU
CA NO GE/AFJ-25/2020-21 MANNING/OPERATIO OF PUMP HOUSE NO11,08 AND 03 AND MANNING OPERATION AND MAINTENANCE OF SWIMMING POOL AT AF STN JAMMU
2020_MES_387449_2
CA NO GE/AFJ-25/2020-21
Open Tender
Electrical and Maintenance Works
Item Rate
334 days
JAMMU
AS PER TENDER DOCUMENTS AND AS PER POLICY IN VOGUE
9 documents required · 9 mandatory
₹500
GE AF JAMMU
₹51,500
Yes
2 Feb 2021
12 Dec 2020
30 Dec 2020
12 Dec 2020
28 Dec 2020
14 Dec 2020
Amount
Outsourcing of Services for Manning and operation of following Plants installed at water Tube well No.8, 3 and 11 at 23 wing AF station Jammu in two Shifts per day including Sundays and Holidays from 0500Hrs to 1300Hrs & 1300Hrs to 2100Hrs by deploying minimum 01 (One) Skilled Fitter General Mechanic (FGM) per shift: PLANTS INSTALLED AT TUBE WELL NO. 11 AT 23 WING AF STATION JAMMU: (i) Submersible motor pump set of capacity 33 HP - 01 No. (ii) Diesel engine driven Generator Set of capacity 100 KVA for providing Stand by power supply. -01 No. (iii) Altoc Dosing Pump for chlorination -01 No.
PLANTS INSTALLED AT TUBE WELL NO. 3 AT 23 WING AF STATION JAMMU: i) VT pumpset of capacity 25 HP - 01 No. ii) Altoc Dosing Pump for chlorination -01 No. (iii) Voltage Stabilizer 100 KVA-01 No. PLANTS INSTALLED AT TUBE WELL NO. 08 AT 23 WING AF STATION JAMMU: (i) Submersible motor pump set of capacity 33 HP - 01 No. (ii) Diesel engine driven Generator Set of capacity 100 KVA with APFC panel for providing Stand by power supply. -01 No. (iii) Altoc Dosing Pump for chlorination -01 No. (iv) Voltage Stabilizer-100 KVA
Note for Item No 1.00: -(a)The personnel deployed by the Contractor must have technically qualified having Govt approved ITI with minimum two years experience/ A person having SSC qualification with seven years experience in the relavent trade / Ex servicemen of the relavent trade (Fitter General Mechanic/Pump Operator/DG Set Operator as the case may be) and shall have adequate knowledge of operation and maintenence of DG Set/Pump Sets and other Electrical Machinery. (b) Persons employed must have Aadhar number and linked bank account. (c) Contractor shall install & Maintain digital Bio-metric attendance systems at the installation as required to record the attendance of the personnel and authorised admin for Bio matric machine will be the concern JE E/M Incharge of the installation all as directed by Engineer-in-charge. Expenditure to this effect shall be included in quoted rate.
(d) It is an express condition of the contract that payment of wages to tradesmans/workers deployed at site of work shall be made through bank account of individuals only. The contractor deposit/ distribute the payment in first week of every month and will confirm to Engineer-in-Charge by submitting the bank transaction document from bank. The salary paid to the trademen /worker shall not be less than minimum wages/fair wages as notified by Govt. time to time by the Govt. (e) The unit rate quoted shall be be deemed to include cost of consumable items such as cotton, waste cloth, Hessain cloths, T & P required for maintenance, nuts, bolts, washers, grease, oil, battery terminals, stationery for log book sheet, attendance register (in addition to Biometric attendance), Fist Aid Box, Operator dress and other minor items.
(f) In case of Non deployment of operator on duty, non rectification of defects / cleaning of installation, non maintenance of log sheets and other records in the installation on particuar day, it shall be considered that operator are absent on duty and recovery at double cost of basic rate quoted (i.e. minimum fair wages) by contractor under ser item No 1.03 here-in-before shall be deducted by the Engineer-In-Charge from the dues without any notice to the Firm. (h) Contractor shall provide proper uniform to the operator as approved by Engineer-in-charge. Operator without approved uniform will treated as absent and liable for panel recovery as stated above.
(j) No claim whatsoever shall be admissible regarding distance between plants/installation and location of plant/installation to be kept operational under above items. Rate quoted are deemed to be inclusive of this aspect. (k) On acceptance of the agreement, contractor shall produce the copies of educational qualifications and experience certificates of tradesmen being deployed in the work and the same shall be verified by the Engineer-in-charge. (l) The contractor on acceptance will acquire valid entry passes from AF Security Section for entering in restricted area through Engineer-in-charge. (m) The contractor shall engage the requisite manpower in the manner so as to give adequate rest to the working personnel already deployed.
Material and labour for Cleaning of silt, sludge mud accumulated at bottom of drain all around swimming pool (passing water of suction sweeper) by removing concrete covers over drain and refixing to the entire satisfaction of Engineer-in- charge.
Supply only hard wire teeth brush for cleaning of swimming pool of size 30 cm length and width not less than 10 cms complete all as specified and as directed by Engineer-in-Charge.
Material and labour for Servicing of DG set of capacity 100 KVA installed at Pump House No 11 & 8 at 23 Wing AF Jammu including carrying out maintenance check alongwith following repairs: (a) Drain out the lubricating oil from sump and refilling after proper cleaning. (b) Check tightness of all nuts and bolts. (c) Check adjustment of V belt for driving engine water pump and alternator. (d) Assembling complete old serviceable parts (e) Testing of DG set after servicing to entire satisfaction of Engineer-in-Charge. (f) Cleaning of air cleaner filter and renew after period of hrs run as specified by manfacturers manual. (Labour only)
Note: (i). Any minor parts such as screws, washers, split pins, clips etc shall be supplied by the firm and rate for the same shall be deemed to be included in the unit rate quoted. (ii) The job shall be carried out after two hundred hrs run of DG set and shall be measured and paid separately no. of times carried out during the entire period of contract. (iii) Any parts other than mentioned in above Note (i) required to be replaced during servicing of engine shall be measured and paid for separately as "Supply only".
Supply only following provisional items to be incorporated in the work against relevant item of this BOQ here in before for DG set of capacity 100 KVA.
Oil filter Catridge with 'O' rings / gasket.
Fuel filter Catridge with 'O' rings / gasket.
Air cleaner filter Catridge with 'O' rings / gasket.
Material and labour for Repair/ servicing to battery charging alternator 12 Volt by repllacing worn out required parts to be supplied by the firm and testing as directed by Engr-in-Charge.
Material and labour for Servicing / repair to self starter 12 volts by replacing burnt out field coil and other worn out parts such as carbon bush, spring etc as required, assembling with serviceable and new parts including taking out from engine and refixing at its original position after repair suitable for any type of Engine.
Supply and fixing fan belt for any size of the Engine as per existing for DG set 100 KVA capacity including taking down of old unserviceable fan belt complete all as specified and as directed.
Material and labour for synthetic insulating Mat of size 2 m x 1m x 19 mm thick suitable for 1100 volts, complete all as specified and directed by Engr-in-charge.
Excavation in trenches n.exc 1.5 M wide and n.exc. 1.5 M in depth and getting out in soft/loose soil all as directed by Engr-in-Charge
Returning filling in including spreading levelling and well ramming in n.exc. 25 Cum complete all as directed by Engr-in-Charge.
Removing the excavated material n.exc. 50m and depositing where directed at & level n.exc. 1.5m above the starting point all as directed by Engr-in-charge.
Supply , laying, jointing & testing of DI Type K-7 pipe, 150mm dia, with socket & spigot ends, with cement morter zinc coated out side as per IS 8329/2000 in standard length suitable for and including push on tyton joints with rubber rings, laid in trenches, including taking up or down old unserviceable water mains (including all fittings), of any type including burning out joints including turning water OFF or ON as necessary and taking off and refixing covers, access doors etc.complete all as specified and directed by Engr in charge.
Supply , laying, jointing & testing of DI Type K-7 pipe, 100mm dia, with socket & spigot ends, with cement morter zinc coated out side as per IS 8329/2000 in standard length suitable for and including push on tyton joints with rubber rings, laid in trenches, including taking up or down old unserviceable water mains (including all fittings), of any type including burning out joints including turning water OFF or ON as necessary and taking off and refixing covers, access doors etc.complete all as specified and directed by Engr in charge.
S & F Pressure gauge 4" dial 0-21 kgs rating with taking down old u/s pressure gauge of any type
Plain Cement concrete in foundations, filling and mass concrete Type C2 1:3:6 (using 40 mm graded crushed stone aggregates) complete all as specified and as directed.
Dismantling of existing unserviceable/rusted panel and supply, fabrication, fixing, installation, testing and commissioning of Panel box, double door, sheet metal closed, for indoor/outdoor type, made up of CRCA sheet 2/3mm thick (2mm for indoor or 3mm for outdoor) as required at site, including cutting, bending, drilling, welding of factory fabricated LT panel of existing size by using 40 x 40 x 5mm angle iron frame (or other section as per manufacturer's requirements) for each unit panel, fixing with nuts, bolts on 75 x 40 mm ISMC as per direction of Engineer-in-Charge and aldrops for locking arrangements and bottom cable enty of both sides duly powder coated painted, in LT panel, comforming to IS:8623, IEC:60439 and CPRI approved, protection class IP 65 with provision to accommodate the followings: -
(a) Aluminium bus bar of suitable size for RYB (live) and neutral as main bus bar. (b) Aluminium bus bar of suitable size for RYB and neutral as down links/connectivity to LT MCCBs. (c) Digital Ammeter and voltmeter for Incoming. (d) LED Indication lamps for RYB for Incoming Indication (e) ON load front operated change over switch (f) MCCBs as Existing capacity as Incomer (g) MCCBs Existing capacity as out going NOTE: (i) CRCA sheet of 2/3mm thick shall only be measured and paid under this item. Any angle iron, ISMC channel or any other steel item required to manufacture the panel shall be measured and paid as "Supply only" under ser item No 40.00 here-in-after in this BOQ. (ii) Labour part for fabrication, welding, etc. of complete panel and fixing of all accessories (as mentioned above at ser No 17.01 (a) to (g) above including making all connection is deemed to be included in overall rates quoted by the tenderer against this item. (iii) Accessories mentioned at ser No 17.01 (a) to (g) above shall be measured and paid seperately as "Supply only" under relevant items of this BOQ here-in-after. (iv) Taking down of old unserviceable panel alongwith its all member and accessories is deemed to be included in overall rates quoted against this item. (v) Drawing and size shall be got approved by Engineer-in-Charge before placing the order.
Supply only MCCB 200 Amps 4 pole 36 KA with thermal magnetic release, complete all as specified and directed. Make: Legrand (DPX³) Cat Part No 4202 48 or equal approved in Siemens (3VL)/Schneider (NSX)/L&T (D-Sine)
Supply only MCCB 160 Amps 4 pole 25 KA with adjustable thermal and fixed magnetic setting complete all as specified and directed. Make: Legrand (DPX³) Cat Part No 4200 57 or equal approved in Siemens (3VL)/Schneider (NSX)/L&T (D-Sine)
Supply only MCCB 63 Amps 4 pole 25 KA with adjustable thermal and fixed magnetic setting, complete all as specified and directed. Make: Legrand (DPX³) Cat Part No 4200 53 or equal approved in Siemens (3VL)/Schneider (NSX)/L&T (D-Sine)
Supply only MCCB 32/40 Amps 4 pole 16 KA with adjustable thermal and fixed magnetic setting, complete all as specified and directed. Make: Legrand (DPX³) Cat Part No 4200 02 or equal approved in Siemens (3VL)/Schneider (NSX)/L&T (D-Sine)
Supply only change over switch in sheet metal enclosure, 200 A rating, four pole, LT heavy duty, 415 volts, 50 Hz with side handle complete all as specified and as directed by Engineer-in-Charge. Make: IHBFFE0200 (HSD Code 8536) of Havells or equal approved in Standard/C&S
Supply only LED Indication lamp for LT Panel board RED/YELLO/BLUE, Surface Mounted Device LED technology Low Power consumption < 0.6W Low Voltage Glow Protection (LVGP) Cat No: SIL 240A-240V AC Make: L&T or HPL/Havells
Supply only aluminium bus bar of rating 200A to 400A including bending and drilling of holes as required and fixing in LT panels complete all as specified and as directed by Engineer-in-Charge.
Supply only 50 sqmm copper conductor (HRFR) PVC insulated (unsheathed) flexible single core cable for power panel wiring between bus bar to MCCB of different capacity, complete all as specified and as directed by Engineer-in-Charge. MAKE: L&T / FINOLEX / GRANDPLAY / ANCHOR / POLYCAB
Supply and fixing copper lugs suitable for 50 sqmm single core copper conductor cable, fixed in repairs, complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing single phase preventor 230 volts, 50 cycles, fixed in repairs, complete all as specified and as directed by Engineer-in-Charge. Make: Minilec
Removing of existing filter media from the pressure filteration plant and cleaning of pressure filter tank by removing of sand, stone, mud, sludge and broken stainer etc and supply and fixing of new stainer approx 50 Nos and supply and filling of new filter media of the following size: - (a) 25-15 mm natural pabbles = 15 cubic feet (b) 15-10 mm natuarl pabbles = 15 cubic feet (c) 8-16 mm mesh size sand = 25 cubic feet (d) 16-32 mm mesh size sand = 100 cubic feet and (e) testing of filter including applying of existing synthetic enamel paint two coats over a coat of red oxide primer complete all as specified and specified.
Taking down unserviceable water level indicator and supply, install, testing and commissioning of wall mounting solid state water level indicator cum controller AC & DC driven with 5 stage LED indication system (20, 40, 60, 80 & 100%) with following specifications: - Make: GUATDIAN of Model:LL-C2 (a) AC&DC diven with 6V battery backup to support the display electronic circuit in case of the power failure. (b) An Electric isolation system to isolate the level sensing probe signal voltage/power from the main power supply line. (c) High speed steel sensor probes (6 Nos) for the purpose of sensing water levels. (d) The system should have provision to trip off the motor in case of the empty tank status with motor on and off LED indication.
Supply and fixing of wiring using flexible copper cable of size 6 core 14/0.006 along with GI support wire including taking down unserviceable wiring complete all as specified and as directed by Engineer-in-Charge. MAKE: L&T / FINOLEX / GRANDPLAY / ANCHOR / POLYCAB
Supply and installation in repairs 12 volts 150 AH lead acid wet maintenance free batteries including initial charging with necessary material connecting with battery lead of DG set at site and setting aside including connecting with battery lead of generator complete. MAKE: EXIDE/AMARON/OKAYA
Dismantling of existing unserviceable/rusted panel and supply, fabrication, fixing, installation, testing and commissioning of Panel box, double door, sheet metal closed, consists of 3 compartments having front shutters with floor and wall mounting provisions, dust and vermin proof, having dimensions 46" (height) x 30" (width) x 10" (depth) factory fabricated, made out of 16 guage CRCA sheet and built upon regid frame work of angle iron of size 50x50x6mm and having front doors with neoprence rubber gasket including danger plate, earthing strip point at side, ventilation louvers at the side, bottom detachable gland plate complete with suitable size of Zinc plated nuts, bolts and washers etc. The pannel shall be powder coated and the power and control circuit diagram shall be accompany the eqpt and circuit wiring with colour code solid conductor copper cable for easy identification including incomming/ outgoing cable holes at the bottom. The Panel shall be emmbeded with 50 x 6 mm MS channel and 30 cm above the normal ground level complete with PCC foundation (1:2:4 ) type B2 incl all connections of lugs complete including taking down old panel all as specified and directed. Size of panel should be with provisions and to accomodate and supply and fixing the following items: -
Disconnecting and taking out old unserviceable gaseous chlorination system and supply, installation, testing and commisioning of chemical dosing system suitable for inject solution up to 25 LPH, complete with strainer, stroke controllet, FRP tank of 150 litres capacity, Inlet and outlet piping and comprising of Electrically operated dosing pump and agitator coupled with three phase 415 volts, 50 Hz, 0.50Hp, 1440 RPM motor with starter, agitators blade shall be made up of stainless steel with anticorrosive paint including addition and alteration, taping of existing CI/DI pipe and making connections for Injection of Chlorine and making electrical connections and as directed by Engineer-in-Charge. MAKE: Satya Sai Aqua Pura services or Equal approved make by E-in-C's branch
Material & labour for Earthing using galvanised iron earth plate electrode of size 60cm X 60cm X 6mm thick burried directly in ground vertically at a depth not less than 2.25 mtr below normal ground level with top edge of earth plate at a depth not less than 1.5 mtr below normal ground level, earth plate surrounded from all sides by 15 cm thick and packed layer of charcoal dust and common salt filling in alternate layers including refilling with good earth as specified and electrode connections by using galvanised iron strip of size 32x6mm by means of bolts, nuts, check nuts and washers made of GI and provision of GI pipe medium grade 40 mm dia for protection of earthing lead and 20mm dia for watering arrangement including funnel, wire mesh, CI pit cover and PCC chamber pit with PCC 1:2:4 type B-2 (including necessary excavation and earth work disposal of surplus soil to a distance not exceeding 50 mtr all as specified and shown on plate No 5 of SSR Part-I 2009.
Supply only Altoc GP Calcium Based granular Disinfectant (Aqua fit) in 45kg packaging plastic dram for water treatment complete all as specified and as directed by Engineer-in-Charge. Make: Purichlor or equivalent E-in-C's approved make.
Supply only current transformer (CT) of 200/5 Amps ratio resin cast type wound CT on LT panel board and connections to secondary terminals to ammeter all as specified and as directed by Engineer-in-Charge. MAKE: GE/KAPPA/RISHAB
Supply only current transformer (CT) of 160/5 Amps ratio resin cast type wound CT on LT panel board and connections to secondary terminals to ammeter all as specified and as directed by Engineer-in-Charge. MAKE: GE/KAPPA/RISHAB
Supply only current transformer (CT) of 63/5 Amps ratio resin cast type wound CT on LT panel board and connections to secondary terminals to ammeter all as specified and as directed by Engineer-in-Charge. MAKE: GE/KAPPA/RISHAB
Supply only current transformer (CT) of 32/5 Amps ratio resin cast type wound CT on LT panel board and connections to secondary terminals to ammeter all as specified and as directed by Engineer-in-Charge. MAKE: GE/KAPPA/RISHAB
Supply only mild steel angle iron or MS channel framed work conforming to Fe-410 W (Gde-E-250) quality-B, including applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and as directed by Engineer-in-Charge
SCHEDULE 'A' PART-II (Schedule of credit) Credit amount of Rs (Refer schedule of credit) for retrieved material mentioned in Sch 'A' Part-II of Tender documents in PDF form will be deducted offline during acceptance of tender of lowest bidder.
M/S VIDYA ENTERPRISES
MAMTA ENTERPRISES
asian traders
bamral builder
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .