Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹33.1 LAccepted-AOC | L1 | Accepted-AOC lowest and reasonable | |
| 2 | L2₹38.8 L+₹5.6 L (16.9%)Rejected-Finance 00 BHUSAR FARM KE PASS K K PURI NANDANPURA JHANSI UTTAR PRADESH 284003 | JHANSI | UTTAR PRADESH | 284003 | L2 | Rejected-Finance Not lowest | |
| 3 | L3₹39.4 L+₹6.2 L (18.7%)Rejected-Finance FLAT NO 06 BLDG NO B 2 PLEASANT PARK WANWADI PUNE 411040 | PUNE | MAHARASHTRA | 411040 | L3 | Rejected-Finance Not lowest | |
| 4 | L4₹41.0 L+₹7.7 L (23.3%)Rejected-Finance | L4 | Rejected-Finance Not lowest | |
| 5 | L5₹42.5 L+₹9.3 L (28.0%)Rejected-Finance | L5 | Rejected-Finance Not lowest |
Tender Value
Refer Docs
EMD Value
₹90,600
Closing Date
30 Jul 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
COL VIKAS KESARWANI
CWE AF LOHEGAON
PROVISION OF RING MAIN WATER SUPPLY SYSTEM AT 9 BRD UNDER GE AF LOHEGAON
2022_MES_527970_2
81853/E8
Open Tender
Civil Works
Item Rate
180 days
GE AF LOHEGAON
Please refer Tender documents. Class D and Cat a(ii)
8 documents required · 8 mandatory
₹500
GE AF LOHEGAON
₹90,600
Yes
26 Sept 2022
12 Jul 2022
6 Aug 2022
12 Jul 2022
30 Jul 2022
18 Jul 2022
60 days
Amount
Taking out/down of old rusted raising main and replace with new ductile iron flaged type pipe of (class-K9) and including connection, testing and commissioning complete all as specified and directed by Engr in Charge:- Note:- (i) Rate quoted by the contractor shall deemed to be included all necessary arrangements for scaffiolding, replacement of raising main pipe line of OHT at Cafs 9 BRD, apply a coat of synthetic enamel paint over the primed surface of pipeline.
150 mm bore
Supply, laying, connecting and testing of New Ductile Iron S/S pipe of (class-K9) including all fittings such as push on rubber gasket joint and commissioning complete all as specified and directed by Engr in Charge:-
100 mm bore
150 mm bore
Supply, laying, connecting and testing in repairs CI/Ductile iron specials including all fittings such as tail piece, bend, socket, etc. as required at site for jointing upto 200 mm dia CI/Ductile iron pipe complete all as specified and directed by Engr-in-Charge.
S & F Sluice Valve, Cast Iron body, Stainless Steel Spindle, Gun Metal Rings including Wheel for operation, Flanged and Drilled, confirming to IS - 14846, Class PN -1.6, Long Body type including all Joints with Rubber Gasket and Jointing Materials, Bolts, Nuts, Washer complete including taking down existing unserviceable sluice Valve all as specified and as directed by Engineer - in - Charge:-
250 mm dia bore
150 mm dia
100 mm dia
Supply, install, testing and commissioning of LT Feeder Piller weather/vermin proof, made out of 3 mm thick CRCA sheet, factory assembled cubicle pattern modular and compartmentalized construction, outdoor type, with front and backside hinged double door with locking arrangement, floor mounted free standing type, duly powder coated, 3 phase and neutral 100 amps current carrying capacity aluminium bus bar with epoxy insulated coating with colour code and insulated support with aluminium earth bus of size 25x3mm with terminal switch, cable galleries, inter connecting bus bar connection/linkage, complete with the following switch gears & accessories described below and mounting of the panel board on ground with PCC (1:3:6) bedding upto a height of 30 cm above gorund level, complete all as specified and as directed by Engineer - in - Charge.:- (a) MCCB, 415 Volt, 4 pole, of capacity 200 Amps, 25 KA - 1 No. (b) MCCB, 415 Volt, 3 pole, of capacity 63 Amps, 25 KA - 2 Nos (c) Star Delta Starter, Fully Automatic, air cooled type complete with all accessories, 415 Volt, 50 Hz of capacity suitable for pumping set 10 HP, 3 Phase, motor – 2 Nos (d) Single phase preventer with reverse phase protection, 415 Volt, 3 Phase, 50 Hz of rating 25 Amps - 2 Nos (e) Electronic (digital) Multimeter suitable for measuring Volts, Amps, frequency, PF etc. panel mounted type - 1 No (f) LED phase indication lamps for 3 phase RYB) –1 set.
Supply, laying, connecting and testing of GI tubing medium grade and including all fittings such as bends, elbows,tees, Union,short pieces,connectors,check nuts,diminishing pieces ,caps and plugs, unions,etc fixed and laid in trenches complete all as specified and directed by Engineer - in - Charge for the following sizes:-.
25 mm dia
50 mm dia
80 mm dia
M & L Construction of Valve Chamber of 750mmx750mmx750mm of internal size suitable for Sluice Valve, with 150 mm thick PCC 1:4:8, Type D2, using 40mm graded aggregate for foundation, 200 mm thick Brickwork with old size Fly Ash Bricks in Cement Mortar 1:6, 40 mm thick PCC, 1:3:6, Type B1, using 20mm graded aggregate Coping, rendering in CM 1:4, 15 mm thick including provision of Mild Steel Sheet Cover 3 mm thick with 1.2X1.2MX0.9M mm size Angle Iron frame work embedded in concrete with suitable hinges and locking arrangements including two coat of synthetic enamel black paint over a coat of red oxide zinc chrome primer to steel surfaces and including necessary earth work excavation in any type of soil etc., removal of surplus soil off the premises complete all as specified and as directed by Engineer in charge.
Excavation in trenches not exceeding 1.5 mtr in width and not exceeding 1.5mtr in depth for taking out/laying of pipes and getting out in soft/loose soil complete all as specified and directed by Engineer - in - Charge.
Excavation in trenches not exceeding 1.5 mtr in width and not exceeding 1.5mtr in depth for taking out/laying of pipes and getting out in hard /dense soil complete all as specified and directed by Engineer - in - Charge.
Excavation in trenches not exceeding 1.5 mtr in width and not exceeding 1.5mtr in depth for taking out/laying of pipes and getting out in soft disintegrated rock complete all as specified and directed by Engineer - in - Charge.
Returning filling in including spreading levelling watering and well ramming in layers n.exc 25cm with soil obtained from excavation complete all as specified and as directed by Engr-in- Charge.
Removing excavated excavated soil/ material not exceeding 50mtr and depositing where directed at a level n.exc 1.5 mtr above the starting point complete all as specified and as directed by Engr-in- Charge.
M&L for precast cement concrete block masonry with solid blocks, exc. 10cm in width with PCC type C1, 1:3:6 (using 20 mm graded stone aggregate) and set in CM (1:6) complete all as specified and as directed by Engr-in- Charge.
M & L for steel structure for bracing, supprots, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding , bending cold or hot, driling holes for bolts, in any shape or size as indicated or size as indicated or directed and inclusive of one primer coat , one under coat and one finising coat of paint all as per diercted by Engr in Charge
Demolition of cement concrete (un-reinforced) in ground floors and pavings not exceeding 15cm thickness (below or above ground level) complete all as specified and as directed by Engr-in- Charge.
M&L for cement concrete (1:3:6) type C2 in foundation filling and mass concrete using 40mm graded stone agg for making good the desturbed floor/wall /duct surface or any foundation work as required on site etc complete all as specified and as directed by Engr-in- Charge.
M/L for providing earthing complete with GI earth plate electrode 600 mm x 600 mm x 6 mm thick buried directly in ground earth pit not less than 2.25 Mtr deep below ground level with top edge of the plate not less than 1.5 Mtr below normal ground level connected to copper earth strip 32X6 mm by means of bolts, nuts, checknuts & washers and connecting to earth dolly all as shown in electrical plate No. 5 of SSR Part I of 2009.00 & & as specified or indicated and testing on completion including exaction/earth work in any type of strata PCC ( 1:3:6 ) type C1 earthing chamber, pre cast slab 50 mm thick in cement concrete ( 1: 2 : 4 ) type B 1 ( reinforced with welded steel wire fabric (XPM) weight not less than 4 Kg / Sqm), funnel with wire mesh, watering pipe of 20 mm bore medium grade and lugs, including GI earth strip 32 X 6 mm with GI protection pipe of 40 mm medium grade 7.5 meter long, etc complete all as specified and directed by ENgr-in- Charge.
Supply laying jointing,testing and comissoning of XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, 3.5 core cross-sectional area 95sqmm complete all as specified and directed by Engr-in-Charge.
S&F copper earth continuity conductor or main earthing lead of size 25 x 4mm fixed to wall on batten or recess or chases or burried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for earthing etc as required complete all as specified and directed by Engr-in-charge.
Supply & fixing in replacement of LT cable 1100 volts grade PVC insulated multistranded copper conductor cable single core of size 35 sqmm complete all as specified and directed by Engr-in- Charge.
A K ENTERPRISES
Chaulya Enterprises
purva engineears and contracters
Shri Sant Cosntruction
CHAITANYA WINDWELL
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .