Loading…
Loading…
| # | Company | Quoted % | Amount | Rank | Status |
|---|---|---|---|---|---|
| 1 | L1₹17.5 LAdmitted-Finance | -46.46% | ₹17.5 L | L1 | Admitted-Finance |
| 2 | L2₹18.5 L+₹95,810.70 (5.47%)Admitted-Finance | -43.53% | ₹18.5 L+₹95,810.70 (5.47%) | L2 | Admitted-Finance |
| 3 | L3₹19.5 L+₹1.9 L (11.1%)Admitted-Finance | -40.50% | ₹19.5 L+₹1.9 L (11.1%) | L3 | Admitted-Finance |
| 4 | L4₹19.9 L+₹2.4 L (13.8%)Admitted-Finance UDAIPUR | -39.09% | ₹19.9 L+₹2.4 L (13.8%) | L4 | Admitted-Finance |
| 5 | L5₹20.0 L+₹2.5 L (14.3%)Admitted-Finance | -38.79% | ₹20.0 L+₹2.5 L (14.3%) | L5 | Admitted-Finance |
Tender Value
₹32.7 L
EMD Value
₹65,400
Closing Date
4 Jul 2026, 6:00 pmClosed
EXECUTIVE ENGINEER LIGHT
JAIPUR NAGAR NIGAM PANDIT DEENDAYAL UPPADHYAY BHAWAN LALKOTHI TONK ROAD JAIPUR
WORK OF INSTALLING HIGH MAST LIGHTS FROM AJMERI GATE (YADGAR) TO SITAPURA IN THE SAFE IDEAL CORRIDOR, YEAR 2026-27
2026_DLB_570777_1
05 EXECUTIVE ENGINEER LIGHT
Open Tender
Electrical Works
Percentage
120 days
JAIPUR
As Per Bid Documents
3 documents required · 3 mandatory
₹500
ONLINE PAY IN JAIPURMC WEBSITE
₹65,400
8 Jul 2026
25 Jun 2026
6 Jul 2026
25 Jun 2026
4 Jul 2026
25 Jun 2026
This is a percentage-rate BOQ. The schedule below shows estimated quantities and rates. Bidders quote a single percentage above or below the total estimated cost.
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | (42.32) SITC of Cutting back up surface up to 2 Mtr. Depth by digging by Bogie including all layers of crust for laying pipe line etc. and making good to original condition (excluding cost bitumen) | 500 | Mtr. | 428 | ₹2,14,000 |
| 2 | (60.2) Providing & Laying P.V.C. / XLPE insulated & P.V.C. sheathed Arrmoured Aluminium cable confirming to IS:1554 P-I / IS :7098 P - I of 1.1 KV with H4- Grade electrolytic aluminium conductor confirming to IS 8130 of purity >99.6 %, round / flat strip armouring of cables, Inner / outer sheath confirming to IS:5831 in existing RCC / Hume / Stoneware / PVC pipe/ open duct/cable trench / Cable tray(with cable tie) including testing etc. as required of following size. OEM must have it's own in house NABL accrediated Laboratory for testing procedure as per IS:10810.For additional technical parameters of product / work refer Annexure 'A' attached with this BSR | - | - | - | - |
| 3 | (60.2.4.3) 16.00 sq. mm*4 core | 500 | Mtr | 238 | ₹1,19,000 |
| 4 | (60.2.5.3) 25.00 sp.mm *3.5 core | 200 | Mtr | 292 | ₹58,400 |
| 5 | (55.1) Providing & Fixing of 240/415 V AC MCB with positive isolation of 10 kA breaking capacity (B/ C/D tripping characteristic as per type of load and site requirement) 4 KV impulse withstand voltage, ISI marked IS 8828(1996) / conforming to IEC 60898-1 2002, IEC 60947-2, low watt losses, trip free mechanisum , energy limiting of class 3 as per IEC, minimum phase termination capacity of 35sq.mm. , conductor line load reversibility , IP 20 contact protection and fitted in existing distribution board/sheets, minimum electrical operation 20,000 upto 20 A rating and 10,000 upto 63 A, 5000 for 80 A & above rating including making connections, testing etc. as required. OEM shall have submit NABL / CPRI / ERDA accrediated lab type test reports & All as per pre approved by Engineer in-charge. For additional technical parameters of product / work refer Annexure 'A' attached with this BSR | - | - | - | - |
| 6 | (55.1.1) Single pole MCB (With B/C curve tripping Characteristics) | - | - | - | - |
| 7 | (55.1.1.2) 6 A to 32 A rating | 10 | Each | 192 | ₹1,920 |
| 8 | (61.13) P / L of Double wall corrugated HDPE pipe confirming to IS : 16205 P-24, Stiffness Class 750 N, Externally corrugated and having smooth surface inside with HDPE Coupler, Elbow, Tee at required Depth below the ground for laying cable of following Nominal Outer dia. MFR Test report from NABL accrediated is to be submitted.(Excavation of Earth & Back filling with compaction is to be Paid Extra)All as per pre approved by Engineer in-charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR . | - | - | - | - |
| 9 | (61.13.1) 50 mm | 500 | Mtr | 87 | ₹43,500 |
| 10 | (53.1) Supply and laying PVC Insulated and PVC Round Sheathed Multi
Core copper conductor (IS:694) and as per IS 8130 : 2013 of 1.1 kV
grade . Wire should be made from 99.90 % purity copper, stranding
in acc. to IS:8130/IEC 60228 for lower watt loss , oxygen free for
less chances of oxidization, insulation PVC type A/C/D , flame
retardant as per IS 10810-53, better amperage rating as per IS:3961
part 5, in existing pipe / open trench / Cable tray / on surface
including making connection etc. as required. For additional
technical parameters of product / work refer Annexure 'A' attached
with this BSR | - | - | - | - |
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.09 MB
BOQ_1015575.xls
BOQ • 0.35 MB
EPROC05XENLIGHT.pdf
Tender Documents • 7.32 MB
datecorri05xenlight.pdf
PDF • 0.46 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .