| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹9.9 LAccepted-AOC 1ST SHAKUNTALA SADAN 04 RAMPURA BASTI LALGARH BIKANER RAJASTHAN 334001 | BIKANER | RAJASTHAN | 334001 | L1 | Accepted-AOC Lowest and reasonable bidder | |
| 2 | L2₹10.8 L+₹12,375 (1.16%)Rejected-Finance | L2 | Rejected-Finance Other than lowest bidder | |
| 3 | L3₹12.1 L+₹1.5 L (13.6%)Rejected-Finance BEHIND POWER HOUSE WARD NO 6 UDASAR BIKANER RAJASTHAN 334022 | BIKANER | RAJASTHAN | 334022 | L3 | Rejected-Finance Other than lowest bidder | |
| 4 | L4₹12.9 L+₹2.3 L (21.4%)Rejected-Finance | L4 | Rejected-Finance Other than lowest bidder | |
| 5 | L5₹13.5 L+₹2.8 L (26.5%)Rejected-Finance STREET NO 11 SECTOR NO 04 TILAK NAGAR SAGAR ROAD BIKANER RAJASTHAN 334001 | BIKANER | RAJASTHAN | 334001 | L5 | Rejected-Finance Other than lowest bidder |
Tender Value
₹20.0 L
EMD Value
₹39,980
Closing Date
2 Oct 2021, 6:00 pmClosed
GE (AF) NAL
GE (AF) Nal, AF Stn Nal Bikaner (Raj)-334001
As described in Bill of quantities
2021_MES_472399_1
GE (AF) NAL/T-25/2021-22
Open Tender
Electrical and Maintenance Works
Item Rate
274 days
GE (AF) NAL BIKANER
As per NIT and tender documents
9 documents required · 9 mandatory
₹500
GE (AF) NAL
₹39,980
Yes
GE (AF) NAL
13 Nov 2021
3 Sept 2021
11 Oct 2021
3 Sept 2021
2 Oct 2021
20 Sept 2021
3 Sept 2021 - 14 Sept 2021
15 Sept 2021
Amount
Taking down carefully point wiring (Light, fan, socket or power complete including fittings such as switches, Ceiling roses, pendants, regulator, sockets etc.) removing from site of work and making good to the disturbed surfaces of walls/floors etc all as specified and directed
BLANK
M&L Point wiring for One light/fan point controlled by one switch with PVC insulated fire retardant low smoke (FRLS) multi stranded copper conductor cable of 1.5 sqmm with and including concealed non-metalic rigid PVC conduit heavy duty (ISI mark) and pressed steel terminal boxes (for mounting switches / sockets /regulators / ceiling roses etc) made out of MS sheet not less than 1.6 mm thick including painting with one coat of red oxide primer on internal and external surface covered with 3mm thick laminated plastic sheet ISI marked including 1.5 sqmm PVC insulated fire retardant low smoke (FRLS) multi stranded copper conductor cable as earth continuity wire connected to common earth and each terminal box/fitting all as specified and directed . Note :- (i)The wiring shall be provided in standard colour code i.e. Red for Phase, Black for Neural and Green for earth. (ii) The quoted rate is deemed to include for cutting/chasing for concealing the conduit and making good the surface to match the existing surfaces. (iii) In case of ceiling portion where concealed conduiting is not possible, the surface conduit shall be provided ad directed. (iv) The earth wire shall be connected to common earth and each terminal boxes and fitting all as directed.
All as per description of serial item No. 3.00 here in before but for One 3-pin socket outlet 5 Amp on independent board.
All as per description of serial item No. 3.00 here in before but one 3 pin socket outlet 5 Amp on same board
All as per description of serial item No. 3.00 here in before but for One 5-pin socket outlet 5/6 & 15/16 Amp on independent board. with 2.5 sqmm FRLS multistranded copper cable including 2.5 sqmm FRLS multistranded copper cable as earth continuity wire connected to common earth and each terminal box/fitting complete all as specified and directed.
M&L Point wiring for One light / fan point controlled by one switch with PVC insulated fire retardant Low smoke (FRLS) multi stranded copper conductor cable of 1.5 sqmm in and including double locked PVC casing caping and pressed steel terminal boxes (for mounting switches / sockets / regulators / ceiling roses etc) made out of MS sheet not less than 1.6 mm thick including painting with one coat of red oxide primer on internal and external surface covered with 3mm thick laminated plastic sheet ISI marked including 1.5 sqmm PVC insulated fire retardant low smoke (FRLS) multi stranded copper conductor cable as earth continuity wire connected to common earth and each terminal box/fitting all as specified and directed . Note :- (i)The wiring shall be provided in standard colour code i.e. Red for Phase, Black for Neural and Green for earth. (ii) The quoted rate is deemed to include for cutting/chasing for concealing the Terminal box, Junction box etc and making good the surface to match the existing surfaces. (iii) In case of ceiling portion where concealed conduiting is not possible, the surface conduit shall be provided ad directed. (iv) The earth wire shall be connected to common earth and each terminal boxes and fitting all as directed.
All as per description of serial item No. 7.00 here in before but for One 3-pin socket outlet 5 Amp on independent board.
All as per description of serial item No. 7.00 here in before but one 3 pin socket outlet 5 Amp on same board
All as per description of serial item No. 7.00 here in before but for One 5-pin socket outlet 5/6 & 15/16 Amp on independent board. with 2.5 sqmm FRLS multistranded copper cable including 2.5 sqmm FRLS multistranded copper cable as earth continuity wire connected to common earth and each terminal box/fitting complete all as specified and directed.
M&L Point wiring (concealed) for One light/fan point controlled by one switch with PVC insulated fire retardant low smoke (FRLS) multi stranded copper conductor cable of 1.5 sqmm in and including stove enamelled steel conduit on surface min 20mm dia (ISI mark) and pressed steel terminal boxes (for mounting switches / sockets /regulators / ceiling roses etc) made out of MS sheet not less than 1.6 mm thick including painting with one coat of red oxide primer on internal and external surface covered with 3mm thick laminated plastic sheet ISI marked including 1.5 sqmm PVC insulated fire retardant low smoke ( FRLS) multi stranded copper conductor cable as earth continuity wire connected to common earth and each terminal box/fitting all as specified and directed . Note :- (i)The wiring shall be provided in standard colour code i.e. Red for Phase, Black for Neural and Green for earth. (ii) The quoted rate is deemed to include for cutting/chasing for concealing the conduit and making good the surface to match the existing surfaces. (iii) In case of ceiling portion where concealed conduiting is not possible, the surface conduit shall be provided ad directed. (iv) The earth wire shall be connected to common earth and each terminal boxes and fitting all as directed.
All as per description of serial item No. 11.00 here in before but for One 3-pin socket outlet 5 Amp on independent board.
All as per description of serial item No. 11.00 here in before but one 3 pin socket outlet 5 Amp on same board
All as per description of serial item No. 11.00 here in before but for One 5-pin socket outlet 5/6 & 15/16 Amp on independent board. with 2.5 sqmm FRLS multistranded copper cable including 2.5 sqmm FRLS multistranded copper cable as earth continuity wire connected to common earth and each terminal box/fitting complete all as specified and directed.
Taking out carefully the existing burnt sub main wiring of size 4 Sqm / 6 Sqmm PVC insulated multi stranded aluminum conductor cable along-with earth continuity conductor from the PVC / rigid steel, concealed / surface conduit complete all as specified and directed. Note:- 03/05 runs of 01 metre cable with one metre conduit shall be considered as one unit for measurement purposes.
Supply and laying sub main wiring complete with 03 runs (Phase, Neutral & Earthing colour code) of single core 6 sqmm fire retardant low smoke (FRLS) PVC insulated copper conductor cable multistranded and sheathed LT 1100 V grade drawn through and including steel metalic conduit 20 mm dia ISI marked and accessories surface fixed on wall /floor etc all as specified. Note:- 03 runs of 01 metre cable with one metre conduit shall be considered as one unit for measurement purposes.
Supply and laying sub main wiring complete with 03 runs (Phase, Neutral & Earthing colour code) of single core 4 sqmm fire retardant low smoke (FRLS) PVC insulated copper conductor cable multistranded and sheathed LT 1100 V grade drawn through and including steel metalic conduit 20 mm dia ISI marked and accessories surface fixed on wall /floor etc all as specified. Note:- 03 runs of 01 metre cable with one metre conduit shall be considered as one unit for measurement purposes.
Supply and laying sub main wiring complete with 05 runs (Phase, Neutral & Earthing colour code) of single core 4 sqmm fire retardant low smoke (FRLS) PVC insulated copper conductor cable multistranded and sheathed LT 1100 V grade drawn through and including non metalic PVC rigid conduit 25mm dia ISI marked and accessories surface fixed on wall /floor etc all as specified. Note:- 05 runs of 01 metre cable with one metre conduit shall be considered as one unit for measurement purposes.
Supply and laying sub main wiring complete with 05 runs (Phase, Neutral & Earthing colour code) of single core 6 sqmm fire retardant low smoke (FRLS) PVC insulated copper conductor cable multistranded and sheathed LT 1100 V grade drawn through and including steel metalic conduit 25mm dia ISI marked and accessories surface fixed on wall /floor etc all as specified. Note:- 05 runs of 01 metre cable with one metre conduit shall be considered as one unit for measurement purposes.
M&L for wiring for 3 light point controlled by one MCB at height of 8 to 10 meter approx in New tech flt bldg with and including 3 runs (Phase, Neutral & Earthing colour code) of 2.5 Sqmm for phase & neutral and 2.5 Sqmm for earth single core wire through existing conduit by providing all T& P and scaffolding etc required to reach upto light point including all safety measures as prescribed and connecting complete all as specified and directed.
Supply and fixing Switch piano flush type single pole one way 5/6 amp complete all as specified and directed..
Supply and fixing Switch piano flush button single pole one way 15/16 amp complete all as specified and directed.
Supply and fixing Switch piano flush type single pole two way 5/6 amp complete all as specified and directed..
Supply and fixing bell push flush type single pole one way 5 amp complete all as specified and directed.
Supply and fixing Socket out let 2 in 1, 3 pin, 5/6 and 15/16 amp multipurpose, flush type complete all as specified and directed.
Supply and fixing Ceiling rose surface Bakelite 65 mm x 50 mm three terminals complete all as specified and directed.
Supply and fixing in repair sheet metal enclosure for SPN DBs with double door for incorporating MCBs IP 43, 4 way with 200 Amp rated busbar, 240 volts as per IS 8623, complete all as specified and directed.
All as per description of serial item No. 27.00 here in before but 8 way
All as per description of serial item No. 27.00 here in before but 12 way
Supply and fixing as in repair MCB SPN 10-32 Amps 240Volts, Breaking capacity 10 KA 'C' curve complete all as specified and directed.
Supply and fixing as in repair MCB SP 6-32 Amps 240Volts, Breaking capacity 10 KA 'C' curve complete all as specified and directed.
Supply and fixing as in repair MCB TPN 63 Amps 415 Volts, Breaking capacity 10 KA 'C' curve complete all as specified and directed.
Supply and fixing in repair sheet metal enclosure for DBs with double door for incorporating MCBs IP 43, TPN 4 way with 200 Amp rated busbar, 240 volts as per IS 8623, complete all as specified and directed.
Supply and fixing in repair vertical TPN DB double door suitable for fixing 125 Amp MCCB , IP 45 protection with powder coated enclosure 4 way insulated busbar assembly including MCCB 4 pole, 415 V, 125A, 16 kA - 01 No complete all as specified and directed.
Suply and fixing Lamp holder angular PVC polycrbonate type with back plate suitable for PVC casing capping/conduit fitting complete all as specified and directed.
Supply and fixing as in repair IP-20 linear Retro LED T-8 tubular lamp with extruded aluminium / PC body and PC diffuser complete with inbuilt driver 1x20 watt, in existing batten/fitting after removing the old choke, stater including electrical connection, Cat Ref LTT8-20 of Make: Crompton Greaves or equivalent in Havells/Phillips
All as per description of serial item No. 36.00 here in before but 1x8 watt / 10 watt
Suply and fixing as in repair recessed LED Driver with input voltage 90-300 V AC , max current 0.7 A and output voltage 40-55 V for ceiling panel layout suitable for 600X600 MM modular ceiling grid and also can be suspended with provided kit complete all as specified and directed. Make : Syska Cat Part No. SSK -PAB-6060-A or equivalent of Philips / Havells/ Crompton
Suply and fixing as in repair recessed LED ceiling panel provided with best in class aesthetics premium white poeder coated frame blends seamlessy with ceiling layout suitable for 600x600 mm modular ceiling grid and also can be suspended with provided kit complete all specified and directed. MAKE LCPL-36-CDL(2x2) of crompton greaves or equivalent of phillips/syska.
Suply and fixing as in repair integrated LED bulk head luminaire 1 x 10 watt comprising of pressure die cast housing, acrylic diffuser & frame IP65 protection & available in 5700k (CDL) & 3000K (WW) colour temperatures pre-wired incl connection with flexible twin core wire complete all as specified and directed. MAKE-crompton greaves Cat Part No. LBHN-10-CDL or equivalent of philips / syska / Havells.
Supply and fixing as in repair IP-20 linear Retro LED T-8 tubular lamp 10 watt with extruded aluminium/ PC body and PC diffuser complete with inbuilt driver 1x10 watt Cat Ref LTT8-10, including new Decorative box type, prewired LED tube, blue colored end caps complete all as specified and directed. Make: Crompton GreavesCat Ref DMLN1 LT8-8/10 or equivalent in Havells/Phillips
Supply and fixing as in repair IP-20 linear Retro LED T-8 tubular lamp with extruded aluminium/ PC body and PC diffuser complete with inbuilt driver 1x20 watt Cat Ref LTT8-20, including new Decorative box type, prewired LED tube, blue colored end caps complete all as specified and directed. Make: Crompton Greaves Cat Ref DMLN1 LT8-16/20 or equivalent in Havells/Phillips
S&F as in repairs sheet metal enclosure single pole and neutral encolsure with two pin and earth plug and socket complete with provision for fixing of one MCB SP 20 Amps complete all as specified and directed.
Supply and fixing as in repairs stepped type electronic fan regulator , SP 230 Volt 100/120 watt complete all as specified and directed.
Supply and fixing as in repair LED PLL lamps retro fit 18 watt suitable for security light fittings 1x18 watt, complete all as specified and directed.
S&F as in repair modular switch 10 Amp one way switch one module complete all as specified and directed.
S&F as in repair modular multi socket 10 Amp 2/3 pin two module complete all as specified and directed.
S&F as in repair modular switch 25 Amp one way switch one module complete all as specified and directed.
S&F as in repair modular socket 25 Amp 2/3 pin two module complete all as specified and directed.
S&F as in repair modular metal box with frame & cover and plate suitable for three module complete all as specified and directed.
S&F as in repair modular metal box with frame & cover and plate suitable for four module complete all as specified and directed.
S&F as in repair modular metal box with frame & cover and plate suitable for six module complete all as specified and directed.
Supply and fixing as in repair Switch flame proof rotary type with termination box in LM6, 16A, single pole 250V complete all as specified and directed.
Supply and fixing as in repair LED light fitting 2 x 16 Watt flame proof, CMRI certified recommended for gas/ vapor group of IIA & IIIB, Zone 1 & 2 and IP 65 protection with die cast aluminum hosing with heat resistant toughened glass with LED tube light fixtures driver, holders, connector etc. Complete with all accessories prewired and including connecting up with three core flexible copper conductor cable with suitable size complete all as specified and directed.
Supply and fixing as in repair LED light fitting 100 Watt flame proof, CMRI certified recommended for gas/ vapor group of IIA & IIIB, Zone 1 & 2 and IP 65 protection with die cast aluminum housing with heat resistant toughened glass, with LED tube light fixtures driver, holders, connector etc. Complete with all accessories prewired and including connecting up with three core flexible copper conductor cable with suitable size complete all as specified and directed.
Supply and fixing in repair HPSV lamp 400 watt elliptical/ tubular E-40 of complete all as specified and directed.
Supply and fixing in repair electronic igniter for integral luminaries suitable for 400W HPSV/MH fitting complete all as specified and directed. Make : Crompton Greaves Cat Part No IGN112S/NH or equivalent in Bajaj/ Havells / Phillips complete all as specified and directed.
Supply and fixing in repair HPSV open construction heavy duty VPIT copper HPSV/HPMV/Metal halide ballast 400 watt choke suitable for HPSV/HPMV/Metal hallied 400W lamp complete all as specified and directed. Make : Crompton Greaves Cat Part No HDBL 40S/MH or equivalent in Havells/ Phillips/Bajaj complete all as specified and directed.
Attending day to day complaints for ceiling fan, exhaust fan and wall mounted fans installed at various locations in AF Stn Nal and rectifying the complaints by servicing of fan, cleaning throughly, greasing ball bearings, oiling bush bearing, replacing split pin and rubber real, replacement of condenser if required and including fixing back in position complete all as specified and directed. Note : (i) Defective parts required to be replaced shall be measured and paid separately under respective items. (ii) Cost of taking down of fan and re-fixing where required shall be included in the unit quoted rate
M&L Dismantling blades, down rod, canopy and taking out burnt stator assembly of ceiling fan 48"/56" sweep and taking down old burnt copper stator winding, cleaning stator slots, rewinding of stator assy with appropriate gauge of super enamelled copper winding wire, insulating material complete and assembling ceiling fan and testing for proper function including provision of split pin of suitable sizes complete all as specified and directed. Note: Cost of taking down of fan and re-fixing is included in unit rate quoted by contractor.
Supply only self lubricated ball bearing of SKF 6201 complete all as specified and directed.
Supply only self lubricated ball bearing of SKF 6202 complete all as specified and directed.
Supply only gun metal self lubricated bush bearings suitable for ceiling fan 48"/56" complete all as specified and directed
Supply only fan condenser 2.5 mfd, 50 Hz, 240 Volts complete all as specified and directed
Supply only fan condenser 4 mfd, 50 Hz, 240 Volts complete all as specified and directed
Supply and fixing as in repair flexible twin core PVC insulated copper cable of size 1.5 sqmm complete all as specified and directed
Opening the exhaust fan, removing the burnt copper winding wire complete cleaning the slots, stator and the rotors and rewinding the exhaust fan 250/300 mm sweep with existing gauge super enamelled copper conductor including varnishing and heating and re-installation etc and re-assembling complete including writing MES No. ( Letter size shall be minimum 5 mm width x 15 mm height) complete all as specified and directed. Note: (i) Spare / Part such as Bearing to be replaced shall be measured and paid for separately as 'Supply only' under respective item of this schedule. (ii) Cost of taking down of fan and re-fixing is included in unit rate of item No. 54 of this Schedule.
Opening the exhaust fan, removing the burnt copper winding wire complete cleaning the slots, stator and the rotors and rewinding the exhaust fan 380/ 450 mm sweep with existing gauge super enamelled copper conductor including varnishing and heating and re-installation etc and re-assembling complete including writing MES No. ( Letter size shall be minimum 5 mm width x 15 mm height) complete all as specified and directed. Note: (i) Spare / Part such as Bearing to be replaced shall be measured and paid for separately as 'Supply only' under respective item of this schedule. (ii) Cost of taking down of fan and re-fixing is included in unit rate of item No. 54 of this Schedule.
Supply only ball bearing suitable for exhaust fan 250 / 300 / 380 / 450mm sweep complete all complete all as specified.
Supply and fixing as in repairs metal louvers with frame suitable for 250/300/380/450 mm sweep exhaust fan of existing make complete all as specified and directed .
M&L Opening the cabin fan / wall mounted fan / table fan / pedastal fan 400/450 mm sweep, removing the burnt copper winding wire complete, cleaning the slots, stator and the rotors and rewinding with existing gauge super enamelled copper conductor including varnishing and heating and re-installation of fan etc complete. Note: (i) Spare / Part such as Bearing required to be replaced shall be measured and paid for separately as 'Supply only' under respective item. (ii) Cost of taking down of fan and re-fixing the same is included in unit rate quoted by contractor of this Schedule.
Supply only ball bearing suitable for cabin fan / wall mounted fan / table fan / pedastal fan of sweep 250 / 300 / 380 / 450mm complete all as specified and directed.
Supply and fixing as in repairs ventilator exhaust fan 250mm fibre body of existing size complete all as specified and directed. Note :- Old unserviceable exhaust fan shall be deposited by the contractor in AGE E/M yard/store.
RBS ENTERPRISES
BIDAWAT ENTERPRISES
RAJENDER ENTERPRISES
JASRAJ AND COMPANY
B.K. ROY & SONS
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .