CIVIL SURGEON SINDHUDURG
CIVIL HOSPITAL SINDHUDURG SINDHUDURGNAGARI TALUKA KUDAL DIST SINDHUDURG
INSTALATION OF MEDICAL GAS PIPLINE SYSTEM, WITH BED HEAD PANEL,CUBICLE CURTAIN TRACK, SURGICAL SCRUB STATION
2019_DHS_504111_1
E-09/DHS/DMF/CEN.OXYGEN SYSTEM/2019-20
Open Tender
Medical Equipments/Waste
Item Rate
45 days
SDH SAWANTWADI DIST SINDHUDURG
Please refer Tender documents.
2 documents required · 2 mandatory
₹3,900
Yes
via Payment Gateway
₹65,000
Yes
CIVIL SURGEON SINDHUDURG
4 Mar 2020
4 Nov 2019
17 Dec 2019
4 Nov 2019
16 Dec 2019
4 Nov 2019
13 Nov 2019
Amount
OXYGEN SYSTEM
SITC Of Indigenous 4+4 size main manifold complete with middle frame with chain for individual cylinder along with Non Return Valves for every cylinder.It should CE compliance. D type bulk cylinder wall type oxygen manifold fabricated from high pressure non arsenical, phosphorous, deoxidized degreased seamless round 16mm OD copper pipe having 15 SWG thicknesses. The cylinders will be connected through extruded brass and hard soldered slip-on tee at every 250mm space. The third side of the tee will be ½” BSP male thread for connecting each cylinder. Each male connection of the tee will be connected with high pressure non return valve with spring loaded seat arrangement. The entire manifold top frame will be supported by 50mm x 50mm x 6mm thick steel angle with suitable distance piece at the back. So that when the manifold top frame is installed it is 50mm away form the surface of the wall. The cylinders will be connected to the manifold through high pressure coiled half hard copper tail pipe with extruded brass end connections. One end connection suitable for cylinder valve and the other end suitable for top frame NRV connection. The Tail pipe will be half hard seamless 3/8” OD and ¼” bore copper pipe. The tail pipe & manifold top frame will be tested hydraulically at 300 kg/cm2 and air tested at 200 kg/cm2. The supplied manifold should come along with manufacturer test certificates. There should be a suitable arrangement for connecting both 4 + 4 cylinder bank to a fully automatic control panel. Middle frame:-The cylinders will be supported by a middle frame fabricated from 3½” x 2½ “ x 6mm thick steel angle to be installed at 3feet 10 inch height from the floor level. This will be curved cut with 4½” radius for support each cylinder. Middle frame will have GI chain link connection to hold each cylinder. The steel middle frame will be powder coated to 3 micron. So that does not rust during us
SITC Of Imported Digital Fully Automatic Control Panel for Oxygen 2100lpm,NFPA-99 standards, It should fully complies and meets NFPA-99 standards only. Country of origin certificate must be submitted. It should be UL Listed/ETL Listed. It shall be dome loaded fully automatic control panel and shall have digital display. It shall be dome loaded fully automatic control panel and Panel should be integrated with pressure gauges, regulators and control switching components inside panel. Should have digital LCD display ( LCD screen size 10incg or above ) the actual running status of bank in use. The unit should be compact and housed in a NEMA Type-1 enclosure with locking provision. It should be fully automatic type and shall switch from “Bank in Use” to “Reserve Bank” without fluctuation in the final line pressure. After the switchover, the “Reserve Bank” shall then become the “Bank in Use” and the “Bank in Use” shall become the “Reserve Bank.” The control panel includes a line gauge, two bank gauges and incorporates six LED’s: two green for “Bank in Use,” two yellow for “Bank Ready” and two red for “Bank Empty” on the front of the cabinet. The manifold shall consist of two bank regulators (dome bias) used to reduce the cylinder pressure to the two line regulators which in turn controls the final line pressure.The manifold has an intermediate and line relief valve that is internally connected to a common vent port, terminating into a 1/2" FNPT pipe. The header bars shall be equipped with highpressure shutoff valves outside the cabinet to allow for emergency isolation of the header bars. The header bar shall incorporate integral check valves for each station. The manifold is equipped with pressure transducers, which sends information to the main circuit board for operation of the fail-safe relay which transmits a remote signal to the master alarm or buzzer.The external shut-off valves connecting to the header bars must be ball valves capable of withstanding pressure of 3,000 psi. The manifold shall be installed in accordance with the requirements stated by NFPA 99, CGA,HTM 02-01,EN ISO 7396 1&2 ,Country of origin certificate must be submitted. It should be UL Listed/ETL Listed.
SITC Of Indigenous 2+2 size Emergency manifold complete with middle frame with chain for individual cylinder along with Non Return Valves for every cylinder .It should CE compliance.oxygen cylinder emergency manifold with 4nos. double stage oxygen high flow regulator installed in parallel and controlled by 15mm NB full port brass ball valve duly electro plated. The construction of the emergency manifold will be similar to the oxygen manifold mention above including the meddle frame.
SITC Of Imported Gas Outlets DISS Points- Front loading Oxygen. NFPA ,UL Listed/ETL Listed certificate. Should fully complies with NFPA-99 standards or CGA standards. 0r HTM02-01 or BS EN ISO 7396 1&2. It should be duly USFDA or UL Listed or ETL Listed. It should be manufactured with a 7-3/4" [197 mm] length type “K” 1/2" [12.7 mm] outside diameter (3/8" nominal) size copper inlet pipe stub, which is silver brazed to the outlet body. The body shall be of 1-5/16" [33 mm] diam¬eter, one piece brass construction. For positive pressure gas services, the outlet shall be equipped with a primary and secondary check valve and the secondary check valve shall be rated at a maximum of 200 psi [1,379 kPa] in the event the primary check valve is removed for maintenance. Outlet bodies shall be gas specific by indexing each gas ser¬vice to a gas specific dual pin indexing arrangement on the respective identification module. It should have large color coded front plate shall be used for ease of gas identification and aesthetic appeal. It should have one piece chromed fascia plate shall frame the outlet. With the back rough-in mounted, the outlet shall adjust from 3/8" [10 mm] to 1" [25 mm] variation in wall thickness. It should have modular design and include a gas specific 16 ga. [1.6 mm] steel mounting plate designed to permit on-site ganging of multiple outlets, in any order, on 5" [127 mm] spacing. It should be cleaned and degreased for medical gas service, factory assembled and tested. It should be Indexed to eliminate interchangeability of gas services. It should have 360° Swivel Inlet Pipe for easy installation and should have universal rough-in assembly to accept quick disconnects or diss front adaptors
SITC Of Indigenous BPC Oxygen flow meter with Humidifier Bottle. 0-15 L/min standard flow rate. It should CE compliance.
SITC Of Imported Oxygen High Pressure Rubber tube white color.
VACUUM SYSTEM
SITC Of Base Frame Mounted Indigenous Oil Lubricated Reciprocating Vacuum Pumps , Model V244 each having 34.60 cfm PD with 2 HP 3 Phase electric motor.
SITC Of Indegenous Vacuum Receiver Tank 500 ltr.
SITC Of Indegenous Bacterial Filter
SITC Of Indegenous Vacuum Pressure Switch
SITC Of Indegenous Vacuum Silencer
SITC Of Imported Gas Outlets DISS Points- Front loading Vacuum. NFPA Type,UL Listed/ETL Listed certificate Should fully complies with NFPA-99 standards or CGA standards.or 0r HTM02-01 or BS EN ISO 7396 1&2.. It should be duly USFDA or UL Listed or ETL Listed. It should be manufactured with a 7-3/4" [197 mm] length type “K” 1/2" [12.7 mm] outside diameter (3/8" nominal) size copper inlet pipe stub, which is silver brazed to the outlet body. The body shall be of 1-5/16" [33 mm] diam¬eter, one piece brass construction. For positive pressure gas services, the outlet shall be equipped with a primary and secondary check valve and the secondary check valve shall be rated at a maximum of 200 psi [1,379 kPa] in the event the primary check valve is removed for maintenance. Outlet bodies shall be gas specific by indexing each gas ser¬vice to a gas specific dual pin indexing arrangement on the respective identification module. It should have large color coded front plate shall be used for ease of gas identification and aesthetic appeal. It should have one piece chromed fascia plate shall frame the outlet. With the back rough-in mounted, the outlet shall adjust from 3/8" [10 mm] to 1" [25 mm] variation in wall thickness. It should have modular design and include a gas specific 16 ga. [1.6 mm] steel mounting plate designed to permit on-site ganging of multiple outlets, in any order, on 5" [127 mm] spacing. It should be cleaned and degreased for medical gas service, factory assembled and tested. It should be Indexed to eliminate interchangeability of gas services. It should have 360° Swivel Inlet Pipe for easy installation and should have universal rough-in assembly to accept quick disconnects or diss front adaptors
SITC Of Indegenous Ward Vacuum Unit with Regulator, Collection Jar of 600 ml with Bracket
SITC Of Imported Vacuum High Pressure Rubber tube Yellow color.
SITC Of Indigenous Combined Electrical Panel vacuum system with duplexing and cascading system and time totalizer, Electrical Wiring Inside Plant Room. Hospital will provide at one point 3 Phase power supply with cable and distrbution panel with phase preventer.
SITC Of Medical Grade Copper Pipes BS EN 13348:2016 BSI Kite Mark, Copper Pipes used should be solid drawn, seamless, Deoxidized phosphorus,non-arsenical, half hard, tempered and degreased, Manufactured as per BS EN 13348: 2016 in eitherR250 half hard or R290 hard Meeting the requirements as per the Medical grade Copper pipe standards. Degreasing of pipe shall be such that there is less than 20mg/m2 (0.20mg/dm2 of hydrocarbons on the degreased surface when tested by method specified by BS EN 13348: 2016. It should also have LLOYD third party inspection of copper pipes. The supplier should provide Manufacturer's Test Certificate of copper pipes for physical Properties and chemical composition. Copper pipes joined by silver brazing method for copper to brass. Inert gas welding technique should be used by passing Nitrogen gas inside the copper pipes during brazing, in order toavoid carbon deposition inside the copper pipes. All copper pipes and fittings like bends, Tees, reducers and straight couplings should be As per EN 1254-1. Copper pipes to be fixed with walls with suitable saddles and supports after erection, All the pipes should be cleaned or purged with the help of dry nitrogen gas, &Should be tested with dry Nitrogen
42 mm OD x 1.2 mm thick
28 mm OD x 1 mm thick
22 mm OD x 1 mm thick
15 mm OD x 1 mm thick
12 mm OD x 0.7 mm thick
SITC Of Imported Aluminium Body Valve Box with Pressure Gauge NFPA-99 standards, The valve box shall be constructed of 18 gauge steel, complete with a baked white enamel finish. Affixed to the opposite sides of the box will be two adjustable steel brackets for the purpose of mounting the box to the structural support. The steel brackets shall accommodate various finished wall thicknesses between 3/8" and 1-3/16" and shall be field adjustable. The frame assembly shall be constructed of anodized aluminum and shall be mounted to the back box assembly by standard 6 x 3/8" tapping screws as provided. With the exception of the security valve box, the removable front shall consist of an opaque window with a pullout ring pre-mounted to the center of the window with the exception of the security valve box, access to the zone shut-off valves shall be by merely pulling the ring assembly to remove the window from the frame. The window can be reinstalled without the use of tools only after the valve handles have been returned to the open position with the exception of the security valve box and the alarm/valve combination units, the window shall be marked to prohibit unauthorized persons from tampering with the valves with the following silk-screen caution: “MEDICAL GAS CONTROL VALVES. CLOSE ONLY IN EMERGENCY” and with the exception of the security valve box and the alarm/valve combination units, each valve shall be supplied with an identification bracket which shall be bolted directly onto the valve box for the purpose of applying an approved medical gas identification label. The front panel shall be labelled to instruct persons to close the valves only in an emergency. The valve box shall be constructed so that the front panel cannot be attached to the box while any valve inside is in the closed position. It should have openings to the box’s interior shall be dust-tight. It should have each pipe inside the box shall come with its own pressure gauge that can be viewed through the clear window. All gases and their respective gauges shall be clearly labelled with the proper color coordination as per NFPA 99. -2 Gas
SITC Of Imported Digital Medical Gas Area Alarm NFPA-99 standards, It should fully complies and meets NFPA-99 standards only. Country of origin certificate must be submitted. It should be UL Listed/ETL Listed certificate must be submitted. The alarm shall be microprocessor based with a 10" screen and capable of monitoring up to 8 sensors. Sensors shall be mounted locally (in the rough-in box) by installing the copper pipe provided or mounted remotely. Sensors shall be automated for gas specific detection. Area alarm shall be fabricated from 18 gauge steel with a 3/8" O.D. type “K” copper pipe for connection to the service line. The default set-points shall be +/- 20% variation from normal condition. In the calibration mode High/Low set-points shall be adjustable by on board push buttons. To view the set points and audible alarm sound level, press and hold the mute button for twenty (20) seconds. The digital sensors can be mounted locally or remotely utilizing shielded twisted pair wiring up to 500 ft. The sensors shall be designed to create interference barrier for increased RFI/EMI protection. The LCD brightness and volume shall be field adjustable. The LCD display shall be readable in poor lighting conditions. Screen text shall be customizable for gas locations. The sensors shall be gas specific with a DISS nut and a nipple. The LCD sensors’ operating range shall be the following: Mid-pressure: 0-99 psi; Oxygen and Vacuum. The alarm shall conform to UL Standard 1069. The alarm shall comply with the electromagnetic compatibility standards FCC Part 15 Class A and ICES-003 Class A. -2 Gas
Imported Isolation Valve with Indegenous Brass fittings
SITC Of Indigenous 1500 MM HORIZONTAL/VERTICAL BED HEAD PANEL - Double Duct,It should CE compliance. It should be constructed of extruded aluminium profiles with 2 channels to provide a modular surface mounted unit with integrated accessory rails for equipment management. It should have 2 separate partition rows wise for medical gases and electrical Switch & sockets. Length should be 1500mm All med gas piping shall be hard-piped and brazed to a single point of connection. Fascia panels, top, middle and bottom cover panels shall be removable for access for easy installation and maintenance. It should be pre piped with provision for 6 gas outlets. (Bed head panels does not include gas outlet cost) It should have 6 electrical sockets., RJ-45=1, RJ-11=1, Picture Bed head Panel It should be supplied with a reading /examination luminary over the bed head Unit. 1no. nurse call switch, 1no.luminary light switch which should be mounted below the panel. Design to meets the need of the ICU Designed to make l recovery more pleasant, should be made of an innovative polycarbonate sheet onto which it is applied a colorful film, featuring pictures recomanded by user,
Supply, Installation Testing and Commissioing 2- Bay Surgical Scrub Station-Stainless Steel Scrub Sink Indigenous : Scrub stations for each operation theatre should have been designed to ensure that surgeons and staff can undergo a thorough aseptic scrub, whether using the count stroke or timed scrub methods. Stainless Steel Scrub Sink. Each fixture is fabricated from heavy gauge, type 304, stainless steel and is seamless welded construction polished to a satin finish. Hands free operation includes infrared sensor with a built-in range of adjustment. User definable settings of 3, 6, 12, 30 and 45 seconds, 1, 3, 5 and 10 minute are available. A thermostatically controlled mixing valve automatically maintains water. It should have a foot operated facility. It should have CE compliance under Class 1 Medical devices directive.
Supply, InstallationTesting and Commissioing of Cubicle Curtain Track :Ceiling Cubical Partition Track Aluminum rail with plastic runner, rings and netted curtains It is made from heavy Duty Aluminium cubicle track size 20mm wide x 30mm high, made of aluminium natural anodized to 15 microns complete with continuous PVC liner, nylon gliders and hooks, plastic end cap, connecting bridge, overlapping joint connector, wall brackets with matching screws to make up cubicle height to 2100mm clearance from floor level at 1000mm spacing and securely fixed to above slab.
MEDICAL ELEBORATE CONCEPT TVT LTD
Sumukha Meditek
MDD MEDICAL SYSTEMS INDIA PVT LTD
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .