Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹31.6 LAccepted-AOC 7 MULLAI NAGAR MAIN ROAD WEST TAMBARAM CHENNAI 600045 | CHENGALPATTU | TAMIL NADU | 600045 | L1 | Accepted-AOC Accepted | |
| 2 | L2₹33.5 L+₹88,863 (2.73%)Rejected-AOC 03 PATEL STREET GANDHI NAGAR AVADI TIRUVALLUR TAMIL NADU 600054 | THIRUVALLUR | TAMIL NADU | 600054 | L2 | Rejected-AOC Reajected | |
| 3 | L3₹34.0 L+₹1.4 L (4.30%)Rejected-AOC | L3 | Rejected-AOC Reajected | |
| 4 | L4₹34.0 L+₹1.4 L (4.37%)Rejected-AOC | L4 | Rejected-AOC Reajected | |
| 5 | L5₹34.9 L+₹2.3 L (7.16%)Rejected-AOC 1074 BAGYALAKSHMI STREET VENKATESAPURAM ARAKKONAM 631002 | ARAKKONAM | RANIPET | TAMIL NADU | 631002 | L5 | Rejected-AOC Reajected |
Tender Value
Refer Docs
EMD Value
₹64,000
Closing Date
24 Jun 2021, 6:00 pmClosed
Garrison Engineer M NAS Arakkonam
Garrison Engineer M NAS Arakkonam 631006
REPAIR MAINTENANCE WORKS TO UNSERVICEABLE LT UG CABLES LT SWITCH GEAR PANEL COMPONENTS COPING AND ALLIED ITEMS IN TECHNICAL ADMIN AREA ARAKKONAM
2021_MES_448775_1
8986E8
Open Tender
Electrical and Maintenance Works
Item Rate
120 days
Arakkonam
AS PER NIT
7 documents required · 7 mandatory
₹500
Garrison Engineer M NAS Arakkonam
₹64,000
Yes
30 Jun 2021
5 Jun 2021
26 Jun 2021
5 Jun 2021
24 Jun 2021
19 Jun 2021
7 Jun 2021 - 12 Jun 2021
Amount
Material and labour for cleaning and servicing complete for LT ACB of capacity upto 630 Amps any type including contacts and busbars connections with CRC spray, checking the incomming and out going bus bar connections /power cable and tightening of all bolts,nuts at power cables/ bus bar including replacement of burnt copper/ aluminium lugs as per site requirement, removing the carbon deposit and reconditioning of door lock complete all as specified and as directed .
All as per item no-1 here-in-before but for LT ACB capacity above 630 and upto 1250 Amps any type
Material and labour for dismantling,taking down, checking,cleaning and servicing of switch gear of rating 315 A to 400A MCCB any type contacts with CRC spray including checking the bus bar connections /power cable from Main Bus bar to MCCB and out going cable connections of MCCB, tightening of incomming and outgoing cables including replacement of Copper / Aluminium lugs as per site requirements including removing the carbon deposit and replacing the gasket of compartment door, reconditioning of door lock complete all as specified and directed.
4. All as per item no-3 here-in-before but for switch gear of rating 200 A to 250A MCCB any type complete all as specified and directed.
5. All as per item no-3 here-in-before but for switch gear of rating 100A to 160 A MCCB any type complete all as specified and directed.
6. All as per item no-3 here-in-before but for switch gear of rating 63 A MCCB any type complete all as specified and directed.
Material and labour for MCCB adjustable thermal and fixed magnetic setting 4 Pole of rating 400 Amps, ICS=100%ICU, breaking capacity 35 KA including additions/ altertions to existing MCCB mounting place in the panel for properly fixing and reconnecting in/ out going bus bar or cable connections including supply and fix suitable rating/ size lugs, extended teriminals as per site requirements and making good distrubed panel surfaces complete all as specified and as directed by Engr-in-charge. Make: Schneider /ABB /Legrand /Siemens
All as per item No.07 here-in-before but for MCCB of rating 320 Amps, ICS=100%ICU, 4 pole, breaking capacity 35 KA.
All as per item No.07 here-in-before but for MCCB of rating 250 Amps, ICS=100%ICU, 4 pole, breaking capacity 35 KA.
Material and labour for straight through cable heat shrinkable joint kit for 1.1 KV grade complete with jointing material and accessories like lugs etc., complete suitable for following size XLPE cable complete all as specified and as directed by Engr-in-charge.
150 sqmm 3.5 core to 185 sqmm 3.5 core
50 sqmm 3.5 core to 120 sqmm 3.5 core
25 sqmm 4 core
16 sqmm 4 core
Dismantling and taking out following size cable from existing feeder pillar/ LT panel and removing/ cutting burned part of cable including taking out loop for extension of cable upto required length and fixing /connecting the cable in existing position including necessary nuts, bolts, lugs of approriate size and refixing of cable gland for following sizes complete all as specified and as directed by Engr-in-charge. Note: The quoted rate includes necessary earth work and supply and fixing of lugs of appropriate sizes.
185 sqmm to 240 sqmm
95 sqmm to 120 sqmm
50 sqmm to 70 sqmm
16 sqmm to 35 sqmm
Surface excavation not exc 30 cms deep and average 15 cms deep and getting out in soft/ loose soil including removing green vegetation, roots, bushes etc., from surroundings of poles, panels, etc., complete all as specified and as directed by Engr-in-charge.
Material and labour for preparation of old plastered or unplastered cemented surface and applying two coats of white wash on cemented surface/ wall etc., complete all as specified and as directed by Engr-in-charge.
Excavation in trenches, not exc 1.5m wide and not exc 1.5m in depth for taking up/ laying cable etc., and getting out for soft/ loose soil complete all as specified and as directed by Engr-in-charge.
Material and labour for cutting of bituminous road/ floor for laying of pipe/ cables not exc 1.5m wide and not exc 1.5m deep including refilling with material and watering well ramming compacting and making good with PCC 1:2:4 type B-1 suitable thick complete all as specified and as directed by Engr-in-charge. Note: PCC shall be measured and paid separately under respective item of schedule.
Taking up existing old/ unserviceable/ burnt under ground cable from the existing positions/ trenches etc., including testing with the help of megger, disconnecting and removing unserviceable portion of cable complete all as specified and as directed by Engr-in-charge. Notes: (i) Excavation/ earth work shall be measured and paid seprately under relavent items. (ii) Retrived serviceable bricks from site be properly stacked and reused as protection to UG cable and shall be measured and paid separetely under relevent items. (iii) Serviceable portion of cable shall be relayed as directed and shall be measured and paid separetely under relevent items.
240 Sqmm 3.5 core
185 sq mm 3.5 core
120 sqmm 3.5 core
95 sqmm 3.5 core
50 sqmm 3.5 core
25 sqmm 4 core
16 sqmm 4 core
Relaying serviceable portion of cable as obtained against item No.16 here-in-before in the trench including necessary connections with suitable lugs complete all as specified and as directed by Engr-in-charge. Note: Cable straight through joints/ bus bar chamber if any as per site requirement shall be measured and paid seprately under relevent item of schedule.
240 Sqmm 3.5 core
185 sq mm 3.5 core
120 sqmm 3.5 core
95 sqmm 3.5 core
50 sqmm 3.5 core
25 sqmm 4 core
16 sqmm 4 core
Supply, laying XLPE insulated, screen, PVC bedded, galvanised steel strip or wire armoured, electric power cable (heavy duty) with aluminium conductor of following size for replacement of unserviceable portion of cable including connecting up with proper size aluminium lugs, glands wherever necessary in LT panels/ bus bar chamber panel /joints etc., as per site requirement including testing complete all as specified and as directed. Make: POLYCAB/ NICCO/ PLAZA/ Havells/ KEI Note: (i) Rates includes supply and fix necessary glands, lugs, etc., (ii) Excavation/ earth work shall be measured and paid separately under relevent items. (iii) Cable straight through joints/ bus bar chamber if any as per site requirement shall be measured and paid seprately under relevent item of schedule.
240 Sqmm 3.5 core
185 sq mm 3.5 core
120 sqmm 3.5 core
95 sqmm 3.5 core
50 sqmm 3.5 core
25 sqmm 4 core
16 sqmm 4 core
Spreading riddled earth as obtained from item No.14 here-in-before for UG cable cushioning complete all as specified and as directed by Engr-in-charge. Note: If the required quantity of riddled earth not obtained from above item the contractor should bring the same from other location shown (not beyond 50m) including necessary earthwork as directed for borrow pit /trench to obtain the required quantity including removing surplus soil without any additional cost and the cost deemed to be included in the rate quoted by the contractor.
Supply and lay pipe galvanised iron tubing light grade of 50mm dia in trenches/ under road or floor /on wall /near pole /panel etc., including taking out the corroded old pipe complete all as specified and as directed by Engr-in-charge. Make: Tata /Jindal /Prakash /Surya
All as per item No.20 here-in-before but galvanised iron tubing light grade of 80mm dia.
All as per item No.20 here-in-before but galvanised iron tubing light grade of 100mm dia.
All as per item No.20 here-in-before but galvanised iron tubing light grade of 40mm dia.
Supply and lay standard size common burnt clay building bricks sub class 'B' for cable protection, laid dry complete all as specified and as directed by Engr-in-charge.
Relaying of serviceable bricks as obtained from item No.14 here-in-before complete all as specified and as directed by Engr-in-charge.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25cms for soft /loose soil complete all as specified and as directed by Engr-in-charge.
Removing excavated material to a distance not exc 50m and depositing where directed at a level not exc 1.5m above the starting point complete all as specified and as directed by Engr-in-charge.
Material and labour for PCC in roof kerb or mud stops, rounded or chemfered on edges type, road cutting filling etc., PCC 1:3:6 (Using 20mm graded stone aggregate) complete all as specified and as directed by Engr-in-charge.
Material and labour for MCCB adjustable thermal and fixed magnetic setting 415V, 3 Pole of rating 200 Amps, ICS=100%ICU, breaking capacity 36 KA including additions /altertions to existing MCCB mounting place in the panel for properly fixing and reconnecting in/ out going bus bar or cable connections including supply and fix suitable rating/ size lugs, extended terminals as per site requirements and making good distrubed panel surfaces complete all as specified and as directed by Engr-in-charge. Make: Schneider /ABB /Legrand /Siemens
All as per item No.29 here-in-before but for MCCB of rating 160 Amps, ICS=100%ICU, 3 pole, breaking capacity 16 KA.
All as per item No.29 here-in-before but for MCCB of rating 63 Amps, ICS=100%ICU, 3 pole, breaking capacity 16 KA.
All as per item No.29 here-in-before but for MCCB of rating 100 Amps, ICS=100%ICU, 3 pole, breaking capacity 16 KA.
Supply and lay in replacement synthetic insulating rubber mat of size 2000x1000x12mm ISI marked complete all as specified and as directed by Engr-in-charge.
Supply and lay in replacement synthetic insulating rubber mat of size 2000x1000x10mm ISI marked complete all as specified and as directed by Engr-in-charge.
Supply and fix for drawn GI strip 32x6mm in replacement complete all as specified and as directed by Engr-in-charge.
Material and labour for MS chequered plate of thickness not less than 5mm and area as per site requirement size to cover cable duct openings including repairing works to edges of duct with appropriate PCC to place MS chequered plate equally on the duct in the installations complete including painting with two coats of synthetic enamel paint of approved tint over a coat of red oxide primer and taking out the broken PCC duct covers complete all as specified and as directed by Engr-in-charge.
Supply and fix GI pipe light grade 15mm dia on walls, roof/ laid on floors, ground etc., with all fittings as GI wire protection complete all as specified and as directed by Engr-in-charge. Make: Tata /Jindal /Prakash /Surya
Material and labour for earthing complete with using GI earth plate electrode of size 600x600x6mm thick buried directly in ground vertically to a depth of not less than 2.25m below ground level, with top edge of the earth plate at a depth of not less than 1.5m below ground and connected to GI earth wire 4mm by means of GI bolts and nuts, check nuts, washers and GI earth wire protected by GI pipe light grade 15mm bore and connecting to panel /DBs etc., as per site requirement including alternate layers of charcoal and salt crystal, necessary excavation, earth work in any type of soil PCC (1:3:6) type C-1 earth chamber, 40mm thick RCC cover with 6mm dia MS bars 10 cm c/c on both ways as reinforcement complete including watering pipe 20mm dia medium grade with funnel complete with mesh all as shown in electrical plate No.3 of MES schedule Part 1 complete including testing on completion complete all as specified and as directed by Engr-in-charge. Note: (i) Quoted rate deemed to include necessary earth work, PCC chamber, RCC cover, reinforcement, removal of surplus soil, site clearance etc., (ii) GI earth wire, GI tubing light grade 15mm bore upto 7.5m deemed to be included in the rate quoted by the contractor. (iii) Quoted rate include testing after completion from test point and the desired earth resistance shall be not more than 2 ohm. If the desired result is not obtained the earthing will be re done by the contractor at no extra cost.
Supply and fix for drawn GI wire 4mm complete all as specified and as directed by Engr-in-charge.
Material and labour for PCC 1:3:6 type C1 (Using 20mm graded stone aggregate) as in copping of electric pole at site including providing necessary form work complete all as specified and as directed by Engr-in-charge.
SIVA ENTERPRISES
SREE BALAJI ENTERPRISES
SUSII CONSTRUCTIONS
m/s SRI VALLI ENTERPRISES
PSK Enterprises
RD ENTERPRISES
HRML CONSTRUCTIONS
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .