| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹23.2 LAccepted-AOC | L1 | Accepted-AOC BEING L1 | |
| 2 | L2₹26.1 L+₹2.7 L (11.4%)Rejected-Finance | L2 | Rejected-Finance Rejected being L2 | |
| 3 | L3₹27.0 L+₹3.6 L (15.3%)Rejected-Finance | L3 | Rejected-Finance Rejected being L3 | |
| 4 | L4₹27.5 L+₹4.1 L (17.7%)Rejected-Finance 254 GOVT HOUSING COLONY CHANNAPORA SRINAGAR 190015 | SRINAGAR | SRINAGAR | JAMMU AND KASHMIR | 190015 | L4 | Rejected-Finance Rejected being L4 |
Tender Value
Refer Docs
EMD Value
₹71,000
Closing Date
10 Dec 2020, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
CWE HQ 134 Wks Engrs
HQ 134 Works Engineer, PIN-914134, c/o 56 APO
REPAIRS/ MAINT OF HIGH TENSION DISTRIBUTION SYSTEM AND ALLIED WKS AT KHREUH, SHERE-E-SHALI AND KHUNMOH UNDER GE 861 EWS
2020_MES_393573_1
134 WE-58/2020-21
Open Tender
Civil Works
Item Rate
270 days
Srinagar
Please see tender documents
8 documents required · 8 mandatory
₹500
Yes
GE 861 EWS
₹71,000
Yes
12 Jan 2021
7 Nov 2020
12 Dec 2020
7 Nov 2020
10 Dec 2020
26 Nov 2020
60 days
Amount
Excavation in trenches not exceeding 1.5m wide and not exceeding 1.5m deep and getting out soft/loose soil for laying cables/ pipes/erection of poles etc complete all as specified and directed by Engineer-in-charge.
Excavation in trenches exceeding 1.5m wide and n.exc 3 mtr deep and getting out in soft /loose soil for laying cables/ pipes/erection of poles etc, complete all as specified and directed by Engineer-in-charge.
Removing surplus soil to a distance not exceeding 50mtr and deposited where directed at a level not exceeding 1.50 mtr above the starting point, complete, all as specified and directed by Engr-in-Charge.
Returning, filling in soil including spreading, levelling, watering and well ramming in layers not exceeding 25 cm thick, complete all as specified and directed by Engr-in-Charge.
Supply and lay in trenches river sand clean including spreading/ levelling cushioning for underground cables all as specified and directed.
Supply and laying in replacement reinforced precast concrete cable cover, class HV, type 2, flat size 450mm x 180mm x 40mm complete, all as specified and directed by Engr-in-Charge.
Plain cement concrete (1:4:8) type D-2 (using 40mm graded crushed stone aggregates) as in foundation of pole etc all specified and directed.
PCC 1:3:6 type C-2 using 40mm graded stone aggregate as in foundation filling and mass concrete for stay and pole complete all as specified and directed.
M & L for PCC 1:2:4 type B-1 using 20 mm graded stone aggregate including use and waste of form work for coping of pole and stay foundation complete all as specified and directed by Engr-in-charge.
Cable jointing kit for 11 KV (Earthed) grade cable for straight through heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 70 sqmm to 95 sqmm complete all as specified and directed by Engr-in-Charge.
Cable jointing kit for 11 KV (Earthed) grade cable for straight through heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 120 sqmm to 185 sqmm complete all as specified and directed by Engr-in-Charge.
Cable jointing kit for 11 KV (Earthed) grade cable for indoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 70 sqmm to 95 sqmm complete all as specified and directed by Engr-in-Charge.
Cable jointing kit for 11 KV (Earthed) grade cable for outdoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 70 sqmm to 95 sqmm complete all as specified and directed by Engr-in-Charge.
Cable jointing kit for 11 KV (Earthed) grade cable for outdoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 120 sqmm to 185 sqmm complete all as specified and directed by Engr-in-Charge.
XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power UG cables (heavy duty) with aluminium conductor HT cable, 11000 volts, grade cross sectional area 95 sqmm 3 Core including taking down old unserviceable ACSR conductor, complete all as specified and directed by Engr-in-Charge.
XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power UG cables (heavy duty) with aluminium conductor HT cable, 11000 volts, grade cross sectional area 70 sq. mm 3 Core including taking down old unserviceable ACSR conductor, complete all as specified and directed by Engr-in-Charge.
Supply and fixing steel tubular swaged poles complete with cast iron base plate, finial taper plug, bolts, nuts, screws as specified type 410 SP-55 (11.0 mtr long) and erecting in position all as specified and directed including painting the exposed portion with two coats of aluminium paint over a coat of red oxide primer and internally through out, plus embedded portion with two coats of black bituminous paint over a coat of red oxide primer and marking of pole number and taking down old unserviceable Poles 11 mtr long, complete all as specified and directed by Engr-in-Charge. Note : Excavation, PCC for foundation and earth work shall be measured and paid separately.
Supply and install, testing and commissioning air break isolating Switch triple pole mechanically operated with vertical isolated mounting on 09 insulator and steel frame with mechanism worked from ground level and including operating rod 25mm dia medium GI of required length and locking arrangements of capacity 200 Amps 11/6.6 KV with and including drop out fuse set complete including making all incoming/outgoing connections all as directed and painting of steel work with two coats of aluminium paint over a coat of red oxide primer including taking down old and unserviceable switch complete all as specified and directed by Engr-in-Charge.
S&F (in repair) Cross arms, bracings, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed and inclusive of one primer coat, one under coat and one finishing coat of paint complete all as specified and directed by Engr-in-Charge.
Supply in repair and erect Anti climbing devices; comprising 2.24mm dia galvanised steel 2-strand barbed wire with 2.00mm dia barbs wrapped spirally round poles, to a length of 0.5 to 1.0 meter clamped and properly secured or as ordered, complete, all as specified and directed by Engr-in-Charge (clamps measured separately).
S&F (In repair) Aluminium conductor steel reinforced any size in over head lines on HT poles including stretching the aluminium conductor and binding with binding wires of aluminium or aluminium tapes etc. jumpers and connections, complete all as specified and directed by Engr-in-Charge.
S& F in repair lightning arresters gapless metal oxide type with all fittings, suitable for a system voltage of 11/6.6 KV and of class 10 KA, complete all as specified and directed by Engr-in-Charge.
Replacement of danger notice plate of 1.6mm thick mild steel sheet, vitreous, enamelled white with letters. figures and conventional skull and bones in signal red colour and fixed with MS clamps made of 25 x 3mm MS flat, bolts and nuts for HT 25 x 20 cm size complete all as specified and directed by Engr-in-Charge.
Supply and fixing in replacement of expulsion type HT drop out fuse of superior quality of capacity 10-25 Amps with two Nos insulator per pole complete all as specified and directed by Engr-in-Charge.
Pin type white, brown and green insulator including one galvanised mild steel spindle, two galvanised iron washers and one galvanised iron nut 150mm high, 150mm dia for 11000 volts grade including taking down old unserviceable complete all as specified and directed by Engr-in-Charge.
Disc type insulator, vitreous 145 mm high and 255 mm dia ball and socket type, white, brown or green two in series assembly for tension with tension clamps for conductors working pressure 11000 volts including taking down old unserviceable complete all as specified and directed by Engr-in-Charge.
Loop type insulator, vitreous, porcelain, white, brown or green insulator large size, with over all dimensions 90 x 140 mm, clearance of hole 25.5mm including taking down old unserviceable complete all as specified and directed by Engr-in-Charge.
S & F in repair of Stay assembly complete with accessories as shown in electrical plate No 1 as per SSR Part-I (2009), diameter of stay rod 16mm & MS plate 230mm x 230mm x 6mm thick , complete all as specified and directed by Engr-in-Charge. Note:- Loop type insulator, stay clamps, excavation and concrete work shall be measured and paid separately.
Filtration of transformer oil step down 11/6.6 KV / 0-433 V indoor/outdoor type up to 500 KVA capacity installed at different sub stations/locations using filtration and heating equipment at site by re-circulating transformer oil heating, dehydration and improving di-electric strength of the oil to withstand 40 KV for one minute including testing of oil as specified and directed. NOTE : Transformer oil test kit shall be provided by the contractor at site for testing of oil.
Supply and filling of fresh transformer power oil of BDV not less than 40KVA for topping up reduced level due to evaporation/leakage/loss due to dehydration in HT transformer complete all specified and directed by Engr-in-Charge. Make : Power link/ Power oil/ Savita/ Midel
S & F (in repair) of HT Bushes porcelain, vitreous with brass spindle, threaded with washer, nuts, lock and rubber seal suitable for transformer of capacity upto 160 KVA complete all as specified and directed by Engr-in-Charge.
S & F in repair of HT Bushes porcelain, vitreous with brass spindle, threaded with washer, nuts, lock and rubber seal suitable for transformer of capacity exc 160 KVA but n.exc 300 KVA complete all as specified and directed by Engr-in-Charge.
S & F in repair LT bushes porcelain Vitreous with brass spindle threaded with washers nuts, locknuts and rubber seal for indoor/outdoor transformer of capacity not exceeding 160 KVA complete all as specified and directed by Engr-in-Charge.
S & F in repair of LT bushes porcelain Vitreous with brass spindle threaded with washers nuts, locknuts and rubber seal for indoor/outdoor transformer of capacity exceeding 160 KVA but n.exc 300 KVA complete all as specified and directed by Engr-in-Charge.
S & F in repair of Breather assembly CI body of standard size filled with silica gel of transformer up to 300 KVA complete with nuts, bolts and washers complete all as specified and directed by Engr-in-Charge.
S & F in repair and fabricating, jointing and connecting with galvanised steel wire 3.15 mm dia cradles hexagonal/rectangular complete all as specified and directed by Engr-in-Charge.
GI tubing light grade galvanised with all fittings for cable protection fixed with poles laid in trenches /fixed to wall etc of nominal bore dia 80 mm, complete all as specified and directed by Engineer-in-Charge.
Supply and spreading coarse aggregates of size 20 mm at different places around HT pole structure/feeder panel upto depth 45cm complete all as specified and directed by Engr-in-Charge.
Supply and spreading fine aggregates (sand) at different places around HT pole structure/Feeder panel upto depth 40 cm complete all as specified and directed by Engr-in-Charge .
Trimming of tree branches touching to the over head power line of one span or removing of cut tree branches from the site as per the direction of AGE E/M complete including removing the tree branches. Notes:- (i) Written shut down shall be obtained from concerned JE/AGE (E/M) before cutting of tree branches touching to the HT over head lines or near to the HT over head lines. (ii) Span between two poles will be treated as one span and measured in one Job. (iii) Proper and adequate precaution to be taken by contractor of his men while performing the trimming work at site. (iv) T & P such as ladder, rope, cutter, Axes and other related tools shall be provided by the contractor.
Supplying and laying of HT rubber mat of size1.0m x 2.0m x 19mm , complete all as specified and directed by Engr-in-Charge. . Make: Jyoti/Dunlop/Electromate.
Earthing complete with galvanised steel earth plate electrode 600x600x6mm buried directly in ground not less than 2.25 mtr deep below normal ground level with top edge of earth plate not less than 1.5mtr below normal ground level connected to the Galvanised iron strip 32x6mm size by means of bolts ,nuts, check nuts and washers of galvanised iron and 32x6mm GI strip protected by provision of GI light grade pipe 40 mm bore incl provision of concrete pit in PCC1:2:4 type B-1, using 20 mm graded stone aggregates with 40 mm thick cover of RCC (1:2:4) reinforced with XPM weight not less than 4 Kg /Sqm and 6mm dia bar handle, excavation and earth work in any type of soil, charcoal dust and salt light grade GI watering pipe 20 mm bore with funnel and wire mesh and medium grade GI protection pipe 15mm bore 5 Mtr long and GI strip upto main earthing of pole complete all as shown in electrical plate No 3 of MES Sch 2009 Part-I all as specified and directed. Notes:- (i) Main earthing strip from earth plate electrode to test point upto length of 7.5 metres length shall deem to be included in the unit rate quoted against this item. (ii) GI protection pipe & earthing lead beyond 7.5 metres shall be measured and paid for separately under appropriate item of Sch A part-I. (iii) On testing after completion if desired resistance is not obtained, the contractor shall redo the earthing without any extra cost to the department.
Maint free safe earthing system (set of four electrode to be used as grid for equipment earthing) each pit complete with 01 number UL 467 approved/CPRI tested copper bonded (copper gladded earth rod with 250 microns of copper cladding) earth rod with 17.2mm dia 3000mm long electrode buried in ground to bore holes 120mm dia vertically to a depth not less than 3.50 mtr deep blow ground level or L shape in case of Rocky condition (2 ft deep and 8 ft horizontal) with top edge of earth electrode at a depth not less than 500mm below normal ground level, provision of copper bus bar of size 200mmx25mmx6mm for inter connection with copper earth lead strip 25mm x3mm and further connected to test point terminal block all as directed each earth pit shall include minimum 50 Kg (two bags of 25 Kg each) NABL lab certified back fill compound and 6 Kg (two container of 3Kg Each) NABL Lab certified conductive gel compound for filing bore holes with mother soil mixed in 1:3 ratio (one part of back fill compound and three part of mother soil), so as to achieve earth resistance below 1 Ohm including excavation of poly pit chamber with poly plastic pit cover (cost of ply pit chamber with poly plastic pit cover shall be deemed to be including in the rate quoted) complete all as specified and as directed by Engr in charge. Make Dhruva Technology Pvt Ltd, Pragati, Ashgel Electrode or equivalent. Note: (a) Copper strip beyond test point shall be measured and paid separately. (b) Contractor shall give guarantee of minimum 5 yrs for the earthing carried out by him. (c) The rate of quoted is inclusive of test point made of phosphorous bronze of size 75x75x25mm, drilled and screwed including 3 Nos 8mm dia 25mm long brass nuts and bolts complete all as directed. (d) Any other fittings/fixtures if technically required for achieving desired results (if not included above) shall be provided by contractor without any extra cost to the Govt (e) On testing after completion if the desired resistance is not obtained the contractor shall redo the earthing without any extra cost of department.
M&L for preparation of old painted surfaces, removing dust and other deposited materials by scraping from HT tubular pole of 11 Mtr long and applying two coat of black paint upto 1mtr height from ground level and rest part of the pole applying two coat of aluminium paint, including cross arms bracing, GI pipe, nuts, bolts and washers etc complete all as specified and directed by Engr-in-Charge.
S&F cable route indicator made out of GI plate 3mm thick 6' dia 25 x 25 x 3mm angle iron, 60mm long embedded in PCC block of suitable size with moulded letter "HT cable" suitable inscribed including PCC 1:2:4 type B1 (using 40mm graded aggregate block of 200 x 200 x 200mm size complete all as specified and directed by Engr-in-Charge.
Re-stretching of aluminium conductor any size and length complete including removing kinks and providing new binding wire /Jumper where required complete all as specified and directed by Engr-in-Charge. Note :- (i) Span from one pole to next pole will be considered as a on job (ii) Any damage cause die to contractor men will be rectified without any extra payment. (iii) T &P such as ladder, rope, cutter, Axes and other related material will be provided by the contractor.
Demolition of brickwork or stone/ boulder masonry, built in cement mortar including all quoins, arches, pillars, etc, complete all as specified and directed by Engr-in-Charge.
Brick work with sub class "B" bricks straight or curved on plan exceeding 6 metre mean radius built in cement mortar 1:6 using old size bricks complete all as specified and directed by Engineer-in-Charge.
15mm thick rendering on fair faces of brick/concrete/ stone wall surface in CM (1:4) of any description, and finishing the surfaces even and smooth without using extra cement complete, complete all as specified and directed by Engr-in-Charge.
M&L for servicing of HT, 11 KV OCB any capacity 50 Hz breaking capacity 25/50 KA by drawing out from panel chamber including removing carbon deposits from contract points, greasing and tightening all fixed and moving contacts for smooth functioning including replacement of tripping and closing coils, 30 Volts, DC and servicing of solenoid switch all as specified and directed by Engr-in-charge. Note : Calibration of relays and primary and secondary injection test shall be conducted by Authorised Company/ Manufactures. Certificated of authority shall be produced by the technical Auth. Make : CG/L&T/Siemens/ABB.
AYOOB CONSTRUCTION COMPANY
M/S Noor Mohammad Shalla
M/S Sky Engineers
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .