Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹6.9 LAccepted-AOC 15 15 KHERIYA BHAN PURANI CHAWANI GWALIOR GWALIOR GWALIOR MADHYA PRADESH 474010 | GWALIOR | MADHYA PRADESH | 474010 | L1 | Accepted-AOC L1 | |
| 2 | L2₹7.1 L+₹2,917 (0.41%)Rejected-AOC VILLAGE TAPARIYAN BABINA CANTT BABINA JHANSI UP 284401 | BABINA | JHANSI | UP | 284401 | L2 | Rejected-AOC L2 | |
| 3 | L3₹8.2 L+₹1.1 L (15.0%)Rejected-AOC 1442 1 NANADANPURA BABINA CANTT TEHSIL DISTT JHANSI UP | BABINA | JHANSI | UP | L3 | Rejected-AOC L3 | |
| 4 | L4₹8.7 L+₹1.6 L (22.1%)Rejected-AOC CIVIL LINE MATATILA ROAD TALBEHAT DISTT LALITPUR U P | TALBEHAT | LALITPUR | U P | L4 | Rejected-AOC L4 |
Tender Value
Refer Docs
Closing Date
21 Jun 2021, 6:00 pmClosed
AGE I TALBEHAT
LAKEVIEW CAMP MIL STN TALBEHAT 284125
REPAIR/MAINT OF LIGHTENING CONDUCTOR AND PROTECTION SYSTEM AND CONNECTED ITEMS INCLUDING REWIRING TO CERTAIN BLDGS IN ZONE-2A, 9B, 9C AND 14 AT TALBEHAT MIL STN
2021_MES_443493_1
AGE(I)/TBT/TOK-23/2021-22
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
MILITARY STATION TALBEHAT
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
AGE I TALBEHAT
Exempted
23 Jul 2021
17 May 2021
23 Jun 2021
22 May 2021
21 Jun 2021
27 May 2021
Amount
Taking down carefully copper/Aluminium point wiring (light/fan/socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fittings etc, removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of wall, floors etc complete all as directed.
Taking down Distribution Boards along with MCB's incl removing the same from site and making good to the disturbed surface complete. Note: All taken down MCBs should be deposited to MES store by the contractor without any extra charge.
Taking down existing sub main wiring of any type and description including removal of teak wood batten/pipe etc complete.
M/L for point wiring concealed type with 1.5sq mm FRLS PVC insulated unsheathed single core multithreaded copper conductor cable 1100 volts grade incl 1.5 Sq mm PVC insulated unsheathed copper conductor cable as earth continuity conductor drown through in and incl FRLS PVC rigid conduit not less than 20 mm dia with its accessories pressed steel terminal box incl 3mm thick ISI marked laminated sheet cover for fixing switches/socket/regulators etc for the following: Wire: Make -Mescab/Polycab/KEI PVC conduit: Make -Polycab/Precision/Plaza Note:- On RCC ceiling/column, false ceiling, AC/Metallic Sheet ceiling wiring done on surface with conduit/PVC Casing caping and its accessories.
One light/fan/bell point controlled by one No piano type switch 5 Amps single pole one way
One light point controlled by 2-way piano type switches 5 Amps two way for stair case.
One socket outlet 5/3 pin 6 AMPS controlled by one switch on the same board.
One socket outlet 5/3 pin 6 AMPS controlled by one switch on independent board.
All as per item NO 4.00 above but 3 pin socket out let 15/16 Amps on the independent Board all as spfd with single core unsheathed PVC insulated cable multistranded copper conductor of size 4 sq mm for phase & neutral & 4 sq mm for earth continuity conductor.
S&F Switch Piano Flush button single pole one way 5/6 Amp. MAKE:- Havells(Reo)/Anchor(Penta)/Gold Medal
S&F Switch Piano Flush button single pole two way 5/6 Amp. MAKE:- Havells(Reo)/Anchor(Penta)/Gold Medal
S&F Switch Piano Flush button single pole one way 15/16 Amp. MAKE:- Havells(Reo)/Anchor(Penta)/Gold Medal
S&F socket outlet 2 in 1, 3 pin & 2 pin, 5/6 Amp, 240 volt. MAKE:- Havells(Reo)/Anchor(Penta)/Gold Medal
S&F socket outlet 2 in 1 , 3 pin & 2 pin, 5/6 Amp and 15/16 Amp, 240 volt. MAKE:- Havells(Reo)/Anchor(Penta)/Gold Medal
S&F ceiling rose surface bakelite 65mmx50mm 100watt three terminal. MAKE:- Havells(Reo)/Anchor(Penta)/Gold Medal
S&F step type electronic fan regulator flush type on the existing phenolic laminated sheet. MAKE:- Havells(Reo)/Anchor(Penta)/Gold Medal
S&F Lamp hoder/Batten holder PVC/Polycarbonate insulated body with metal ring and back plate for batten fitting. MAKE:- Havells(Reo)/Anchor(Penta)/Gold Medal
S&F Bell Ding Dong type, AC 230 Volts, Single pole. MAKE:- Havells(Reo)/Anchor(Penta)/Gold Medal
S&F Bell Push, flush type, 5 Amp, AC-230 Volts, single pole. MAKE:- Havells(Reo)/Anchor(Penta)/Gold Medal
S&F Switch modular type single pole one way 6/10 Amp 240 volt. MAKE:- Havells(Reo)/Anchor(Roma classic)/Philips
S&F Switch modular type single pole one way 16/20 Amp 240 volt. MAKE:- Havells(Reo)/Anchor(Penta)/Gold Medal
S&F for socket modular type 2 & 3 Pin 6/10 Amp with shuttered, suitable for 2 module 240 volt. MAKE:-Havells(Reo)/Anchor(Roma classic)/Philips
S&F for socket modular type 2 & 3 Pin 6/16 Amp flush type, with shuttered, suitable for 2 module. Make: Havells(Oro)/Anchor(Roma classic)/Philips
S&F Bell push modular type single pole one way 6 Amp 240 volt. MAKE:-Havells(Reo)/Anchor(Roma classic)/Philips/C&S
S&F fan regulator modular type electronic step type, suitable for 2 modules 100 watt, 240 volt. MAKE:-Havells(Reo)/Anchor(Roma classic)/Philips
M&L for sub main wiring with two single core PVC insulated of size 6 sqmm FRLS unsheathed copper conductor 1100 volt grade multistranded and incl drawn through and including non metallic rigid PVC conduit and conduit accessories of 25 mm external dia and conduit FRLS accessories of ISI marks medium grade including 6.0 sqmm FRLS copper wire for earth continuity wire and connected of common earth dolly. Wire: Make -Mescab/Polycab/KEI PVC conduit: Make -Polycab/Precision/Plaza Note:- (i)One run of conduit two run of 6 sq mm copper conductor & one run of 6.0 sq mm copper conductor is measured as one unit. (ii) On RCC ceiling/column, false ceiling, AC/Metallic Sheet ceiling wiring done on surface with conduit and its accessories.
M&L for sub main wiring with two single core PVC insulated of size 4.0 sqmm FRLS unsheathed copper conductor 1100 volt grade multistranded and incl drawn through and including non metallic rigid PVC conduit and conduit accessories of 20 mm external dia and conduit FRLS accessories of ISI marks medium grade including 4.0 sqmm FRLS copper wire for earth continuity wire and connected of common earth dolly. Wire: Make -Mescab/Polycab/KEI PVC conduit: Make -Polycab/Precision/Plaza Note:- (i)One run of conduit two run of 4 sq mm copper conductor & one run of 4.0 sq mm copper conductor is measured as one unit. (ii) On RCC ceiling/column, false ceiling, AC/Metallic Sheet ceiling wiring done on surface with conduit and its accessories.
S&F in replacement single pole and neutral enclosure with a two pin and earth socket complete with one single pole MCB of 20 Amp 240 volt. Make:- Legrand/Hager/Schneider/Indoasian/Siemens.
S&F sheet metal enclosure double door for MCB DB single pole and neutral 8 way with 200 Amps 240 volts double door (Metallic) type. Make:- Legrand/Hager/Schneider/Indoasian/Siemens.
S&F sheet metal enclosure double door for MCB DB single pole and neutral 4 way with 200 Amps, 240 volts double door (Metallic) type. Make:- Legrand/Hager/Schneider/Indoasian/Siemens.
S&F sheet metal enclosure double door for MCB D B Triple pole and neutral 4 way, (4+12) with 200 Amps rated bus bar 440 volts earth dolly IP-43, IK09, double door (Metallic) type. Make:- Legrand/Hager/Schneider/Indoasian/Siemens. Note:-MCB are measured and paid separately under respective items.
S&F MCB SP 5 to 63 Amps 240 volts 'C' series, 10 KA, 50 Hz, confirming to IS/IEC-60898-1. Make:- As approved Make of DB
S&F MCB SPN 20 to 40 Amps 240 volts 'C' series, 10 KA, 50 Hz, confirming to IS/IEC-60898-1. Make:- As approved Make of DB
S&F MCB TPN 40 to 63 Amp, 440 volt 'C' series, 16 KA, 50 Hz, confirming to IS/IEC-60898-1. Make:- As approved Make of DB
Supply and fixing LED 4' batten light 18/20 Watt 230 Volt, complete connection with PVC insulated multi stranded copper flexible wire twin core of suitable size from nearest source complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing LED 2' batten light 9/10 Watt 230 Volt, complete connection with PVC insulated multi stranded copper flexible wire twin core of suitable size from nearest source complete all as specified and as directed by Engineer-in-Charge.
Material and Labour for earthing complete with galvanized steel earth plate electrode 600 x 600 x 6 mm thick buried directly in ground( earth pit not less than 2.25 meter deep below ground level) with top edge of plate not less than 1.5 meter below normal ground level, connected to galvanized steel earth lead MS flat 25X4 mm dia by means of bolts, nuts, check nuts and washers of galvanized iron or steel, all as shown in electrical plate No 3 of SSR Pt I including necessary excavation and earth work PCC (1:3:6) type C-1 with 50 mm thick pre cast RCC ( 1:2:4) type B-1 cover slab framed with 50X30X4 mm MS angle (reinforced with 6 mm dia deformed bar @ 15 cm C/C both ways and suitable handle of 10 mm dia round bar) including providing charcoal or coke and magnesium sulphate in alternate layers of 15 cm compacted thickness all around the earth electrode, with funnel and 20 mm bore galvanized iron watering pipe (medium grade) wire mesh, copper lugs, complete in all respect., GI earth wire protected by 40 mm bore (light grade) galvanized iron pipe and other end connected to the earth bar (test point) made of MS flat (400X32X6 mm) bend in ‘D’ shape and fixed to wall by means of fast nut or bolt grouted in to wall at 1 mtr from plinth height. 4sqmm PVC insulated (colour green) copper conductor single run as earth continuity conductor along with 15 mm PVC conduit grouted in wall or fixed on wall surface to be continued up to main switch board and fix with common earth dolly as directed by EIC . Disposal of soil to a distance not exceeding 50 mtr and necessary testing on completion complete all as specified and as directed. (Note: Galvanised iron strip 25x4mm included in item rate)
M & L aluminium strip 25x3.15 mm with saddles and fixing screws etc for conductor from roof to ground level & connected to testing point complete all as specified and as directed
M & L Galvanised iron strip 32x6 mm buried in ground level & connected to earth plate.
M & L single pointed Air termination aluminium rod 12mm dia, 300 mm long complete all as specified and as directed
Supply and fixing porcelain vitreous white/brown/green spacers insulator of size 75mmx35mmx40mm height complete with one number galvanized iron stud bolts 66mm long including nut & washers and two number galvanized iron fixing bolts including washers and drilling holes for holding /fixing aluminium strip/roof conductor as required including testing on completion complete all as specified and as directed by the Engineer-in-Charge.
M&L for wooden door size 750x650x10mm thick suitable for existing meter box along with fixing and locking arrangement and including painting complete all as specified and as directed by Engineer-in-Charge.
Cutting of wall, floor and roads 32mm to 230mm deep for fixing of pipe, boxes and exhaust fan etc. complete all as specified and directed.
M&L for cement concrete in foundations, filling and mass concrete type C-2 (1:3:6) 20mm grade aggregate complete all as specified and as directed.
Supply and laying or fixing in replacement GI tubes light grade 40 mm dia, on place of rusted GI pipe in support of cables, on roof/pole/wall/laid in floor/in trenches. Make:- JINDAL, TATA, PRAKASH.
M/S Kharya Associates
M/S SHIVA TRADERS
HARNAM SINGH ANIL SINGH
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .