Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹11.3 LAccepted-AOC | L1 | Accepted-AOC Lowest Bidder | |
| 2 | L2₹11.9 L+₹44,000 (3.83%)Rejected-AOC | L2 | Rejected-AOC Other than lowest Bidder | |
| 3 | L3₹12.0 L+₹46,994 (4.09%)Rejected-AOC | L3 | Rejected-AOC Other than lowest Bidder | |
| 4 | L4₹14.2 L+₹2.7 L (23.5%)Rejected-AOC | L4 | Rejected-AOC Other than lowest Bidder | |
| 5 | L5₹15.4 L+₹3.9 L (33.5%)Rejected-AOC RZ H 5 NANDA BLOCK MAHAVIR ENCLAVE PART 1 PAL AM SOUTH WEST DELHI DELHI 110045 | SOUTH WEST DELHI | DELHI | 110045 | L5 | Rejected-AOC Other than lowest Bidder |
Tender Value
₹18 L
EMD Value
₹36,000
Closing Date
19 Jul 2021, 6:00 pmClosed
GE(S) Jaipur
Garrison Engineer (South) Jaipur Military Engineer Services Kalyan Marg, Jaipur302006
REPAIR/ MAINTENANCE OF STREET LIGHTS AND CONNECTED ITEM UNDER ZONE-III AREA UNDER GE(S) JAIPUR
2021_MES_453359_1
GE (S)J-11P/2021-22 8658/ /E8
Open Tender
Miscellaneous Works
Item Rate
240 days
Jaipur
Class E Cat b(i)
9 documents required · 9 mandatory
₹500
GE (S) Jaipur
₹36,000
Yes
3 Aug 2021
22 Jun 2021
21 Jul 2021
22 Jun 2021
19 Jul 2021
6 Jul 2021
Amount
Disconneting and taking down the U/S street light fitting from pole or wall and repair the same (of any type, capacity & make) by replacement of spare parts & making the fitting functional and refixing after repairs all as specified and directed by Engineer-in-Charge. Note : (i) Spare parts/accessories required to be replaced shall be measured and paid seperately as "Supply only" under the relevent items.
Disconneting and taking down U/S High Mast light fitting from the steel tower and repair the same(of any type, capacity & make) by replacement of spare parts & making the fitting functional and refixing after repairs all as specified and directed by Engineer-in-Charge. Note : Spare parts/accessories required to be replace shall be measured and paid seperately as "Supply only" under the relevent items.
S&F in replacement of 1100 Volts grade heavy duty cable with inner sheathing of PVC tape and overall PVC sheathed in service connection three core stranded aluminum conductor of size 4.0 sqmm, ISI marked, drawn through steel pole from junction box to street light fitting or for OH connections complete all as specified and directed.
S&F in replacement of New Generation Energy Saving 150 W LED flood light, with optical lens, powder coated PDC aluminium body with toughened glass vision having wide operating voltage range & lumen efficacy>105 lm/w.Surge protection upto 10 KV PF>0.95 temp 5700 K to 6500 K IP 66. Make:- Syska Cat Part No. SSK-BLE-150WL or equivalent of CG,Philips,havells,phillips,bajaj.
S&F in replacement of New Generation Energy Saving 250 W LED flood light, with optical lens, powder coated PDC aluminium body with toughened glass vision having wide operating voltage range & lumen efficacy>105 lm/w.Surge protection upto 10 KV PF>0.95 temp 5700 K to 6500 K IP 66. Make:- Syska Cat Part No. SSK-BLE-250WL or equivalent of CG,Philips,havells,phillips,bajaj.
S&F in replacement of 60 W LED street light fitting with lens optics on LEDs, IP 66 protected luminaire fixture made from pressure die cast aluminum housing & heat resistance toughned glass cover with one number of 60 W driver, having wide operating voltage range, surge protection 10 KV as directed by Engineer-in-charge including taking out old U/S street light fitting of any type/size. Make: Halonix, or equivalent in Philips/Wipro/C.G/Havells/C&S/Syska Note: Reducer including cutting, welding etc if required at site for installing LED fiitings shall be deemed to be included in quoted rates.
S&F in replacement of 70 W LED street light fitting with lens optics on LEDs, IP 66 protected luminaire fixture made from pressure die cast aluminum housing & heat resistance toughned glass cover with one number of 60 W driver, having wide operating voltage range, surge protection 10 KV as directed by Engineer-in-charge including taking out old U/S street light fitting of any type/size. Make:- Syska Cat Part No. SSK-BLS-70W or equivalent of Halonix/Philips/Wipro/C.G/Havells/C&S Note: Reducer including cuttig welding etc if required at site for installing LED fiitings shall be deemed to be included in quoted rates.
Supply only in replacement of LED Driver with surge protector suitable for 45 to 60 watt LED fitting complete all as specified and directed by Engr-in-charge.Make CG/ Wipro /Philips/syska/havells/Bajaj. Note:-Driver & surge protector shall be of same make or suitable for LED fitting as available at site.
Supply only in replacement of LED Driver with surge protector suitable for 70 to 80 watt LED fitting complete all as specified and directed by Engr-in-charge.Make CG/ Wipro /Philips/syska/havells/Bajaj. Note:-Driver & surge protector shall be of same make or suitable for LED fitting as available at site.
Supply only in replacement of LED Driver with surge protector suitable for 90 to 100 watt LED fitting complete all as specified and directed by Engr-in-charge.Make CG/ Wipro /Philips/syska/havells/bajaj. Note:-Driver & surge protector shall be of same make or suitable for LED fitting as available at site.
Supply only in replacement of LED Driver with surge protector suitable for 150 watt LED fitting complete all as specified and directed by Engr-in-charge.Make CG/ Wipro /Philips/syska/havells/bajaj. Note:-Driver & surge protector shall be of same make or suitable for LED fitting as available at site.
Supply only in replacement of LED Driver with surge protector suitable for 200 watt LED fitting complete all as specified and directed by Engr-in-charge.Make CG/ Wipro /Philips/syska/havells/bajaj. Note:-Driver & surge protector shall be of same make or suitable for LED fitting as available at site.
Supply only in replacement of LED Driver with surge protector suitable for 250 watt LED fitting complete all as specified and directed by Engr-in-charge.Make CG/ Wipro /Philips/syska/havells/bajaj. Note:-Driver & surge protector shall be of same make or suitable for LED fitting as available at site.
S&F in replacement of thermoplastic, polystyrene unbreakable junction box size 260 x 210 x 116 mm suitable for pole mounted outdoor type IP 65 insulated complete with FI clamp & nut, bolts, washers and including resin type terminal block heavy duty suitable for ring lugs with phase seperators between R, Y, B, N terminals and one MCB SP 6 amp 10 KA, all duly mounted on din cannel, cable glands for cable entry incl GI double clamp made out of 25x4 mm GI strip complete all as specified and directed. Make : Hensel Cat Part No K9350 or eq Syntex/Legrand etc.
Supply,lay,and testing LT underground cable XLPE of size 16 sqmm 4 core insulated screened PVC bedded galvanised steel strip armoured heavy duty with multi stranded aluminium conductor 1100 volts grade (ISI) marked laid in trenches, ducts, pipes or fixed on pole etc. including taking down.
Supply,lay, and testing LT underground cable XLPE of size 25 sqmm 4 core insulated screened PVC bedded galvanised steel strip armoured heavy duty with multi stranded aluminium conductor 1100 volts grade (ISI) marked laid in trenches, ducts, pipes or fixed on pole etc. including taking down.
Labour only for repair of U/S timer switch assembly of any type/rating & accessores/ spares including reconnecting and testing complete. Note : - Supply only accessories/ spare parts shall be measured & paid separatley under respective items of Sch `A`
Supply only following accessories/ spares parts :-
Contactors 4 pole 63 Amp
Contactors 4 pole 40 Amp
Timer Switch Electronic digital type Make:L&T
Excavation in trenches n.exc 1.5 meter wide and n. exc 1.5 meter in depth for foundation etc or for laying of cable etc and getting out in soft/loose soil.
M&L sand cushioning to PVC underground cable with tibba sand and punning to provide a required cover.
M&L bricks for protection cover to underground cable (with old size sub class 'B' bricks) with width equal to length of brick laid dry and flat abutting each other with gaps between adjaccent brick not exceeding 10 mm as directed by Engineer-in -charge.
Returning filling in including spreading levelling watering and well ramming in layers n.exc 25 cm depth.
Removing of excavated material (soil) to a distance n.exc 50 meter and depositing where directed at a level n.exc 1.5 meter above the starting point.
M&L for cutting the existing cable from loop and making end termination with aluminium lugs without jointing kit with cable glands suitable for LT U/G cable of following sizes:
a) 2x6 to 2x16 sqmm .
b) 4x10 to 25x4 sqmm .
All as per itme No. 24.02 above but with cable end jointing kit.
M&L for PCC (1:2:4) type B1 using 20 mm graded crushed stone aggregate as in coping/pedestal of poles including providing necessary formwork for fair finished exposed concrete surfaces including demolition of old coping complete all as specified and directed.
Dismantling of existing u/s concrete/ steel pole including foundation
M&L PCC poles of 9 mtere long lof size 102X172mm at top and 102X279 at bottom, class 10 complete all as directed by Engr-in-charge
Supply and fix steel tubular poles of 9 mtr length with cast iron base plate,finial taper plug, bolts nuts and screws specified type 410 SP-31 complete all as specified and directed
M & L for painting to surfaces of existing Steel tubular pole 9.0/11.0 mtr long with attached accessories (cross arms, clamps, GI protection pipe etc) with one coat of aluminium paint after preparation of surfaces including painting to poles with two coats black & white paints in straps 5 x 30cm alternatively all round the poles from the bottom complete all as specified & directed.
M&L for Trimming of tree in vicinity of electric supply pole/street light pole/solar modules & depositing at places n exc 50m all as directed by Engineer-in-Charge.
Labour for boring under road/drain by manual/machine method for inserting GI tubing up to 50 mm dia for cable protection all as specified and directed.
Supply and lay tube GI light grade of 40 mm bore in trenches/ road crossings/ floor etc. with all fittings for protection of cable complete all as specified & directed.
Material & labour for fixing 40 to 50 mm dia medium grade GI bracket swan neck type of 1.2 meter length complete with clamps channel and angle iron including complete fitting and fixture all as specified and directed.
S&F in repair nature switch for automatic ON/OFF of street light by sensing natural light of 3 phase upto 12KW load. For switching ON< = 30 lux, For switching OFF>=10 Lux, Auto high voltgae sense and trip, auto low voltage sense and trip, 50-60HZ, IP66 protection class 2, with 3 nos contactor and 32-40 Amp MCB and copper wiring by minimum of 10 Sqmm Cat part no- swadeep 02EC 12KW3P or equivalent L&T/Legrand/ Siemens
S&F in repair nature switch for automatic ON/OFF of street light by sensing natural light of 1 phase upto 8KW load. For switching ON< = 30 lux, For switching OFF>=10 Lux, Auto high voltgae sense and trip, auto low voltage sense and trip, 50-60HZ, IP66 protection class 2, with copper wiring by minimum of 10 Sqmm Cat part no- swadeep 02EC 8KW1P or equivalent L&T/Legrand/ Siemens
Laying only LT UG cable 16 sqmm x 4 core to 70 sqmm x 3.5 core making all electrical connections as directed by Engr-in-Charge. Note: UG cable will be issued under Sch 'B' for fixing/ laying only.
M/s Prakash Enterprises
SHREE BHAGWATI ENTERPRISES
S.R.Enterprises
SM CONSTRUCTION COMPANY
DIVYA ASSOCIATES
M/S TRADE LINKERS
M/s Radhey Enterprises
LAKSHMI ASSOCIATES
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .