Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Tender Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹35.4 LAccepted-AOC | L1 | Accepted-AOC BEING LOWEST | |
| 2 | L2₹36.8 L+₹47,971.76 (1.32%)Rejected-Finance 3 3430 NICHOLSON ROAD KASHMERE GATE DELHI DELHI DELHI 110002 | CENTRAL DELHI | DELHI | 110002 | L2 | Rejected-Finance NOT BEING LOWEST | |
| 3 | L3₹36.8 L+₹49,759.58 (1.37%)Rejected-Finance | L3 | Rejected-Finance NOT BEING LOWEST | |
| 4 | L4₹36.8 L+₹54,336.57 (1.50%)Rejected-Finance 32 FATEH ENCLAVE OFFICERS ENCLAVE PHASE II PATIALA 147001 PB | PATIALA | PATIALA | PUNJAB | 147001 | L4 | Rejected-Finance NOT BEING LOWEST | |
| 5 | L5₹38.3 L+₹2.0 L (5.50%)Rejected-Finance 21 GREEN ENCLAVE SULLAR PATIALA 147001 | PATIALA | PATIALA | PUNJAB | 147001 | L5 | Rejected-Finance NOT BEING LOWEST |
Tender Value
Refer Docs
EMD Value
₹80,000
Closing Date
8 Feb 2024, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
LT COL SANDEEP KUMAR
GE NORTH PATIALA MILITARY ENGINEER SERVICES SANGRUR ROAD PATIALA CANTT
SPL REPAIR TO BLDG NO P 48 AND P 65 of 660 ARMY AVN SQN (R AND O) AT MIL STN PATIALA
2024_MES_638032_1
GE (N)/TOKEN-91/2023-2024
Open Tender
Civil Works
Item Rate
180 days
PATIALA
AS PER TENDER DOCUMENTS
9 documents required · 9 mandatory
₹500
GE NORTH PATIALA
₹80,000
Yes
22 Feb 2024
18 Jan 2024
10 Feb 2024
18 Jan 2024
8 Feb 2024
1 Feb 2024
Amount
Taking down cement plaster of any description, any thickness from external surfaces of walls/soffits etc. incl raking out joints, hacking for keys, scrubbibg down with water etc complete all as specified and directed by Engineer-in-Charge.
Removing existing plaster over the affected bricks to be removed using mechanical means. The affected bricks to be completely exposed complete all as specified and directed.
Apparent visible efflorescence to be first cleaned using hard wire brush and all cyrstal deposits to be removed. The bricks shall then be cleaned using soft brush of powdery crystals removed. Then make a 1 to 4 solution of vinegar and water (1 part vinegar to 4 parts water) and apply it to the efflorescence affected area using a nylon brush. Allow the vinegar/ water solution to sit on the surface of the affected area for 15 minutes, but do not allow the solution to dry. Rinse the area with clean water, using low pressure jet. Two cycles of cleaning using vinegar water solution to be repeated complete all as specified and directed.
The joints of bricks so cleaned shall be pointed using cement putty made a site using Sika Latex/SBR polymer diluted at ratio of 1:4 with water. The solution so made shall be used to be mixed with cement to make a putty consistency paste. The cement putty shall be then worked out in the joints which are clean and in SSD condition.
The bricks so pointed shall be cleaned of all dust or deposit using brush. A undiluted single component acrylic polymer-Sika Raintite, to be used to prime the brick surface. The primer while being tacky the first coat of water proofing coating is done, second coat is applied after a time interval of 4-6 hours after the first coat has dried. The water proofing coating shall be two component polymer modified cementitious coating-Sika top seal-107, having a thickness of 1.5mm in two coats. The material to be factory batched and ready to use. The two components shall be mixed using low speed drill having a RPM 350-450 and fitted with a paddle. The mixing to be done for 3-4 mintues to give a brush able consistency mix. The coating shall be done using brush 100-150mm wide brush. It is to be take care that material while being used is agitated every 3-5 mintues to avoid powder part getting settled. The water proofing coating shall have below properties Tensile Strength - 4.56 N/mm2 after 14 days exposure (According to ASTM D 2370) Bond Strength 2.0 N/mm2 at + 27o C (failure in substate). After application of second coat and while the material is still wet, coarse sand is sprinkled over the coating so as to ensure proper mechanical key is provided for subsequent plaster.
M&L for plastering 15mm thick over the treated surface shall be done with 1:4 cement sand plaster added with acrylic polymer-Sika Plastocrete Plus, @ 3% by weight of cement.
M&L for cement plastering 15mm thick in cemet mortar 1:4 including mixing of liquid water proofing compound as per manufacturer's instructions on brick work or concrete surfaces or in chajjas/parapet walls etc finished even and smooth without using extra cement and fixing of chicken wire gauge where directed complete all as specified and as directed by Engineer-in-Charge.
Supply only integral liquid water proofing compound complete all as specified & as directed by Engineer-in-Charge.
M&L for cement plastering 10mm thick in cemet mortar 1:6 on brick work or concrete surfaces finished even and smooth without using extra cement complete all as specified and as directed by Engineer-in-Charge.
M&L for cement plastering 5mm thick in cemet mortar 1:3 as on ceilings or concrete surfaces finished even and smooth without using extra cement complete all as specified and as directed by Engineer-in-Charge.
Complete removal of existing treatment of any type/description from walls/RCC surfaces etc with mechanical means/grinder complete all as specified and directed.
Complete removal of existing treatment of any type/description from ceilings/RCC surfaces etc with mechanical means/grinder complete all as specified and directed.
M & L for preparation of Old/New of plaster surface of wall and applying two coats of oil bound distamper white or tinted over a coat of primer including 1.5 to 2.5 mm thick wall care putty incl one coat of primer over & incl preparation of plastered finished of wall specified and directed by Engineer-in-Charge.
Preparation of new plastered or unplastered surfaces and applying three coats of white wash on wall surfaces complete all as specified and directed
Preparation of new/old plastered surfaces of ceiling and applying three coat of white wash on ceiling surfaces all as specified.
M & L for Preparation old/new of plastered surfaces of walls/soffits and applying two coats of exterior emulsion paint over a coat of primer incl 1.5 to 2.5 mm thick wall care putty and preperation of plastered surface, complete all as specified and directed by Engineer-in-Charge.
Taking down chowkhats or frames (without taking off shutters from the frame) exc 1.5 Sqm and n. exc 4.00 Sqm incl cutting holes and making good reqd shape for hold fast block for new frame complete all as specified.
Taking down chowkhats or frames (without taking off shutters from the frame) n. exc 1.5 Sqm incl cutting holes and making good reqd shape for hold fast block for new frame complete all as specified.
S&F Powder coated Pressed steel frames made of MS sheet of size 125x60mm 1.20 mm thickness for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate, etc., complete as specified,
M&L PCC (1:3:6 ) type C 0 using 12.50 mm graded aggregate as infilling in PS Chowkhats/Holdfast Block all as specified .
Supply & fixed 35mm thick Flush shutters, solid core construction, with partical board core and plywood face panels, commercial type on both sides complete all as specified and directed.
S&F 35 mm thick factory made glazed & Skelton shutter of IInd class H/Wood open rebated & prepared to receive glass or gauze etc without sash bar open rebated with edges of framing plain, chamfered or rounded, fitted with cut & mitred beads for securing glass or guage etc size of stiles rails etc as specified in sec 8 clause 8.24 (a) of SSR Part-I (2010).
S&F 300mm, mild steel ordinary rat tail rod pattern springs including roller and roller plate complete fixed all as specified.
M&L for Powder coated (Minimum thickness of powder coating 50 micron) Anodised aluminium frames and shutters for doors, windows, ventilators with one or more rebates including joining cleat for fixing etc. complete all as specified and directed by Engineer-in-Charge.
S&F tinted sheet glass ordinary quality 4mm thick area n.exc 0.50 sqm each complete all as specified and directed
S&F stainless steel wire cloth 0.36mm nominal dia of wire and 1.40mm avg width of aperture complete all as specified and directed
S&F 12mm thick high density fibre board pre-laminated on both sides (water proof) below & above middle/lock rail in powder coated aluminium doors and to be fixed with and including EPDM gasket to render the glazing, air and water tight etc aluminium beads 20 mm size with and complete all as specified and directed by Engr-In- Charge
S&F stainless steel (304 grade) finished butt hinges 125mm complete all as specified and directed
S&F powder coated aluminium tower bolt 200mm long complete all as specified and directed
S&F powder coated aluminium handles 150mm complete all as specified and directed
S&F powder coated aluminium hook and eye of suitable length adjustable to aluminium window shutters complete all as specified and directed
Dismantling, floor, hearth or wall tiling including CM(bedding (but not backing), removing serviceable tiles to store & rubbish off the premises complete all as specified and directed
M&L for single charge, ceramic, stain & scratch resistant, joint free, premium quality coloured tiles 400 x 400 mm and 8-10 mm thick as in floor etc in any pattern of light & dark tiles as approved set and jointed adhesive of Sika (Ceram Grey) @ 5kg/ sqm and pointed in white or coloured cement to match in floors etc over and pointed in white cement with pigment to match the colour of tiles complete all as specified
M&L 20 mm thick screed bed in CM 1:6 for laying floor finishes complete all as specified and directed by Engr-in-Charge.
M&L for single charge, cermic, stain & scratch resistant, joint free, premium quality coloured tiles 400x 100 mm and 8-10 mm thick as in floor etc in any pattern of light & dark tiles as approved on vertical surfaces such as in skirting / dado etc length of each unit not less than 600mm and height not more than 150 mm set and jointed adhesive of Sika (Ceram Grey) @ 5kg/ sqm over & incl 10 mm thick screed in cement mortar (1:4) over and pointed in white cement with pigment to match the colour of tiles complete all as specified. Note : Skirting should be flushed with the wall plastering
M&L for anti skid ceramic joint free premium quality coloured tiles 300x300mm and 6-7 mm thick as in floors etc in any pattern of light & dark tiles as approved set and jointed in neat cement slurry and pointed in white or colored cement to match in floor etc , over and pointed in white cement with pigment to match the colour of tiles complete all as specified.
M&L for Glazed ceramic tiles area exceeding 0.06 but n exc 0.16 sqm each 7mm thick coloured on vertical surfaces set and jointed in neat cement slurry and pointed in white cement to match including 10 mm thick rendering of CM 1:4 all as directed and specified.
M&L for 10 mm thick rendering on fair faces of brick work or concrete surfaces in CM 1:4 for fixing of wall tiles all as specified and directed
Dismantling of Stone slabs & tiles of any description or thickness in floors, aprons etc. Laid, bedded & pointed in any mortar as described and specified
M&L for baroda green marble machine cut as in shelves/steps/counter tops, 20 mm thick, set and jointed in cement slurry over & including screed of 15 mm thick rendering in cement mortar (1:4) and pointed in cement mixed with pigment to match the shade of slab including rubbing cutting type polishing and bull nose on exposed sides complete all as specified.
Providing machine cut Kota stone slab flooring 18-20 mm thick laid over 20mm thick cement mortar 1:3 screed bed laid and jointed with grey cement slurry mixed with pigments to match the shade of the slab including rubbing and polishig to mirror finish complete to be fixed in any position as described and specification.
S&F in repair stainless steel tubing of 25 mm bore minimum 1.0 mm wall thickness as in curtain rod complete incl accessories like brackets, stops etc all as specified & directed. Note: (For the purpose of mesurement and payment running length of curtain rod only shall be considered.)
S&F in repair Stainless steel sink with drainage board 0.80 mm thick for kitchen with plugs washers and waste pipe of 40mm dia PVC waste pipe incl new fittings upto floor trap,CP waste fitting and including cantilever cast iron brackets, connecting union, etc, overall size 915mm x460 mm with bowl size 410mm x 330mm x 160mm including making good disturbed portion in CM 1:3 or PCC 1:2:4 as directed.
S&F Sink mixer, fancy type, chromium plated , 15mm bore, fixed as in repair complete all as specified and directed
S&F in repair Vitreous china squatting pan of Orissa patten size 580 x 440 white with (C I P trap long size) joint run and lead front or back inlet with integral footrest including connection to trap and to flushing pipe,anti-syphonage pipe, etc, complete and making good to floor in CM 1:3 all as directed and specified.
S&F in repair flushing cistern of PVC 10 ltr. cap. with dual flushing system, valveless syphonic action type, , low level, white/ivory/off white with inlet, ball valve, float and including brackets and connection to pipe etc. and incl all necessary accessories like rag bolts/gel gasket etc as recommended by manufacturer for fixing, packing and taking down existing of any description/size complete in all respect all as specified.
S&F in repair Soap dish, vitreous China white, approximate size 160x 160x90mm complete all as directed and specified.
Taking up or down existing steel tubing and connections, 15mm bore complete all as specified.
S&F Steel water tubing medium grade 15mm bore galvanised with all fittings and fixed to walls and ceiling or laid in floors complete all as specified and directed
Taking up or down existing steel tubing and connections, 20mm bore complete all as specified.
S&F Steel water tubing medium grade 20mm bore galvanised with all fittings and fixed to walls and ceiling or laid in floors complete all as specified and directed
S&F in repair 15 mm dia Bib Tap cast copper alloy fancy type CP with crutch or butterfly handle, screwed down screwed for iron pipe or for brass ferrule complete all as specified and directed
S & F in repair Stop cock cast copper alloy with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule for 15mm bore pipe complete all as specified and directed
S&F Bathing mixer three in one for shower fancy type, chromium plated 15mm bore, non telephonic and including connected accessories, complete all as apecified and directed.
S & F in repair towel rail, CP brass, 20mm dia 'D' type, 60 cm long between flange complete all as specified.
S & F in repair Brass chromium plated shower roses 50mm size with swivel joint any size all as directed and specified.
S&F in repair doubled layered rotational moulded polyethylene (White colour)water storage tanks (cylindrical vertical with closed top / cover) 500 Ltrs capacity hoisted and fixed in position all as specified including 25 mm PVC ball valves, high pressure, with polythene float and fly nut complete screwed for 20mm bore iron pipe and including GI nipple/union of 20mm GI bore to connect to PVC tank complete all as specified.
S&F in repair 20mm bore Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed complete all as specified.
S&F in repair PVC connections 15mm size with brass nuts of length 450mm complete all as directed and specified.
S&F in repair stainless steel grating 150x150 mm size square shaped with cockroach trap for floor trap fixed in position complete all as specified .
Repair to RCC sunshades, Chajjas, Balconies, Columns, bands, beams and similar RCC work at any position/height by dismantling loose/disintegrated portion and dubbing out with Cement Concrete 1:1½:3, 15mm to 50mm thick using 6 to 12mm graded stone aggregate to make up and finished to required shape including provision of necessary supports if required and stitching of cracks with mild steel U clamps made out of 8mm dia @ 150mm c/c with inserting concrete block stretcher with cement mortar 1:3 mixed with adhesive chemical (Polymer based) and reinforced with PVC chicken mesh including form work where ever required and finished with10 mm thick plastering in CM 1:4 finished even and fair without using extra cement including preparation of surfaces to receive finishes complete all as specified and directed.
Demolition of cement concrete un -reinforced in ground floors and pavings n.exc 15cm thickness complete all as specified.
M & L for Plain cement concrete 1:2:4 mix, type B-2 (using 40mm graded Brick aggregate) as in filling of sunken portion complete all as specified and directed.
M & L for bedding layer of cement mortar 15 mm thick for laying floor finishes in cement mortar 1:3 , mixed with water proofing compound, on brick or concrete surfaces of wall of sunken portion , trowelled to even and smooth finish without using extra cement with WPC paid and measered sepretly complete all as specified.
M&L for Applying three coats of brush bond acrylic based cementitious material of approved quality for sunken portion treatment all as per manufacturer instruction and providing 200 mm micron thick polythene film over 85/25 grade bitumen layer @ 0.5 kg /Sqm all as specified
M&L for for providing and fixing stainless steel (Grade 304) railing made of hollow tubes , channels, plates etc , including welding , grinding , polishing, and making curvature (where ever required) and fitting the same with necessary stainless steel nuts and bolts complete , including fixing the railing with necessary accessories and stainless steel dash fasteners , stainless steel bolts etc. of required size , on the top of floor or the side of waist slab with arrangement complete as specified and directed.
Providing 50 mm dia GI pipe medium grade spouts 60 cm long complete all as specified and directed.
S&F Bands, straps, supports or stays for rainwater, ventilating pipes, including bolts, if required: hooks (stay) and similar small articles conforming to Fe-290 Gde-E-165 all as specified
S&F in repair PVC(HDPE) SWR , 110 mm bore, single socketed in any length with rubber ring joints using solvent as per maunfacture instruction, fixed to walls complete all as specified including fixing of pipe to wall with flat iron clamps of size 25 x 3mm, bolts washing, nuts etc as in repairs after taking down existing damaged CI rain water pipe complete all as specified and as directed.
S & F in repair for PVC (SWR) bends/tees of any radius for 110mm bore with access door as complete all as specified.
S&F in repair Cast iron soil, waste and vent pipe,100mm bore, sand cast in any length, with or without ears, with lead joints, fixed to walls/laid in floors and making necessary connections, fixed as in repair complete all as specified and directed.
S&F in repair Cast iron soil, waste and vent pipe,75mm bore, sand cast in any length, with or without ears, with lead joints, fixed to walls/laid in floors and making necessary connections, fixed as in repair complete all as specified and directed.
M&L cast iron nahani/floor/multifloor trap 100 mm dia including jointing with solvent cement in repair fixed in cement concrete (1:2:4) type B1complete all as specified and directed.
S&F in repair CI Bends (any radius), for 100mm bore CI piipes diminishing pieces or tapers (larger bore measured) fitted with oval access doors complete all as specified.
S&F in repair cast iron junction combination 'T' equal or unequal for 100mm bore with access door as complete all as specified.
M&L for cast iron cowls of 100 mm dia complete all as specified and directed.
S&F CI bend (any radius) of 75 mm bore in repair.
Salt glazed stone-ware gully traps,Centrifugal type 150 x 150mm size , square or roundmouthed, type 'P' or 'S' incl CI grating fixed in repair complete all as directed and specified.
Dismantling of brick tiles or terracing tiles single layers on roofs complete all as specified.
Demolition of mud phuska on roof any thickness all as directed.
M & L for Roughening surfaces of old concrete floor/roof by picking, sweeping clean and washing down with water to remove dust, etc. complete all as specified.
M&L PCC 1:3:6 type C-0 using 12.5 mm graded stone aggregates as in padding over roof, minimum thickenss at khurra as 25 mm to maintain a slope of 1:40, complete all as specified and directed.
M & L for Cutting grooves in brick wall, 75mm wide and 65mm deep and shaping horizontal face of groove with cement mortar 1:3 complete all as specified.
M & L for Providing and laying 3mm thick APP (Atactic Polyproplene Polymer) modified prefabricated five layer, weight not less than 4.0 Kg/Sqm water proofing membrane black finished, reinforced with non-woven polyster matt make as approved including of a coat of bitumen primer @ 0.40 ltr/sq.m by the same membrane manufacturer of density 0.87 to 0.89 Kg/Ltr at 25 degree C temperature and viscosity 70 - 160 cps Over the coat, 3mm th 5 layered APP membrane shall be laid using butane torch and sealling all joints, overlaps of joints shall be 75mm longitudianal and 100 mm on transverse direction etc after the surface complete as per standard practice as per manufacturers instructions. The vital physical and chemical parameters of the membrane shall be as under - (i) Joint strength inlongitueinal and transverse direction at 23 degree C as 650/450N/5cms (ii) Tear strength in longitudinal and transverse direction as 300 / 250 N/. Softening point of membrane not less than 150 degree C Cold flexibility upto 20 degree C when tested in accordance with ASTM (D05147) (iii) The laying of membrane shall be got done through the authorised applicator of manufacturer of membrane only all as specified and directed.
Precast PCC plain factory made tiles, ISI marked, 22 mm thick of size 250 mm x 250 mm, fabricated using grey cement & no pigments. on 15 mm thick cement mortar (1:3) bedding and joints grouted flush in cement mortar (1:3) mixed with integral liquid water proofing compound over roof surfaces complete all as specified.
M&L 20 mm thick screed bed in CM 1:4 for laying floor finishes with WPC paid and measered sepretly complete all as specified and directed by Engr-in-Charge.
M&L modified polymeric membrane shall be covered with bituminous based aluminium paint @ 0.2Kg per Sqm in two coats on Non accessible Roofs complete all as specified and directed.
Providing precast cement concrete louvres and jallies, 25mm thick using type B0 (1:2:4) (12.5mm graded aggregate) in CM 1:4) (measured solid), in?cluding all mouldings but excluding frame
M & L for Preparation of new Wooden surfaces of any description, over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified
Demolition of brick work or stone/boulder masonary built in cement mortor including all quoins,arches,pillars etc complete all as specified.
M&L Brick work with sub class 'B' bricks straight or curved on plan exceeding 6m mean raidus bulit in C:M 1:6 all as specified.
M & L for Cement concrete (1:2:4) type B-1 using 20 mm graded stone aggregate as in plinth protection, 50 mm thick, surfaces finished even and smooth without using extra cement as in plinth protection including provision of construction joints complete all as directed by Engr-in-Charge and complete as specified.
M & L for PCC 1:3:6 type C-2 using 40mm graded stone aggretgate, as in base for PVC tanks complete all as specified and directed.
Taking down carefully existing points wiring on surface conduit/concealed conduit for light/ fan/socket /power/ bell from wall & roof along with fitting and fixtures such as switches, sockets, ceiling roses, batten holders, unserviceable light fittings, piece of wires,gutties, conduit, wooden boards etc and making good the disturbed portion of all floor, ceiling etc all as specified and directed.
M & L for point wiring with 1.5 sqmm PVC insulated and unsheathed FRLSH(FLAME RETARDANT LOW SMOKE AND HALOGEN) single core multi-stranded copper conductor for one light/fan and including PVC rigid concealed conduit medium grade 19/20 mm dia to be terminated in pressed steel terminal boxes with top cover plate including 1.5 sqmm PVC insulated and unsheathed FRLSH single core multi-stranded copper earth continuity conductor controlled by one switch and/or one regulator including repairing the surfaces in CM 1:3 and finishing the surface as per existing treatment required for fitting of flush and junction boxes all as specified and directed (Switches and regulators shall be measured and paid for separately.) ( Wiring shall be done as per colour code in IS for phase, neutral and earth) (In case of Modular: Modular cover plate and metal flush boxes incl in Point wiring) Make of Wire: KEI/Havells/Finolex 2.Make of The modular cover plate must be same make of switch/socket.
One light/fan point controlled by one switch 6 amp one way
All as described above but point wiring with 2.5 sqmm single core multi stranded copper conductor PVC insulated & unsheathed cable 1100 volt grade and 1.5 sqmm PVC insulated and unsheathed cable 1100 volt grade with multi stranded copper conductor for earth wire for 15/16 amp multi purpose socket combination point on independent board.
All as per Sl item No 96 above herein before but one 5Amp socket point on same board but with other switches complete all as specified and directed.
All as per Sl item No 96 above herein before but one 5Amp socket point on independent board but with other switches complete all as specified and directed.
M&L modular switch 1 way 6 A, 1 module.
M&L modular socket, 6A-2/3 pin combined, 2 module.
M&L modular switch 16 Amps, 1 module with indicator.
M&L modular socket 16 Amps, 6 pin, 2 module Make
S & F fan regulator modular type 2 module complete all as specified.
S&F ceiling rose 65x17mm three terminals
S& F Modular Bell switch 1 way, 6 Amps, 1 module complete all as specified.
Suppy and fix bell ding dong type AC 230 volts complete all as specified and directed.
S&F Lamp holder ,PVC/polycarbonate type with back plate suitable for batten fitting.
S&F LED bulb 9 watt all as directed by Enineer-in-charge.
Supply and fix in replacement of old unsv building light ,25 W IP 66 LED security light for building luminaire comprising of die cast aluminium housing with weather proof gasket for lamp & driver compartment with system wattage of 25 W . The LED make must be of minimum 100 lumen/watt CCT 6500K .The driver must be power factor > 0.95 with short circuit protection , open circuit protection , reverse polarity protection , high voltage protection. the luminaire must have secondary optics with perfectly matched lens for better light control with GI bracket of suitable size and clamps with fixing accessories connection with PVC insulated three core flexible copper conductor cable 0.75X3 Sqmm with proper clamps .complete all as specified and directed by Engr in charge.
S&F incl taking down 20 watt wall mounted, new generation LED batten fitting length ~ 4 feet with polycarbonate diffuser andextruded thermoplastic body > 90 lumen/watt having correleted color temperature(CCT) of Emitting light 6500/3000 K with CRI of LED >90 . including all fixing accessories & connecting up with PVC insulated twin core flexible copper conductor cable of suitable size complete all as specified and directed by Engr in Charge.
S&F incl taking down 10 watt wall mounted, new generation LED batten fitting length ~ 2 feet with polycarbonate diffuser andextruded thermoplastic body > 90 lumen/watt having correleted color temperature(CCT) of Emitting light 6500/3000 K with CRI of LED >90 . including all fixing accessories & connecting up with PVC insulated twin core flexible copper conductor cable of suitable size complete all as specified and directed by Engr in Charge.
Supply and fix incl taking down new generation energy saving 9/10 watt LED bulk head (porch light fitting) made of plasitic housing with opal diffuser With IP 65. having correleted color temperature(CCR) of Emmiting light 6500/3000 K with CRI of LED >90. connection with PVC insulated twin core flexible copper conductor cable of suitable size.complete all as specified and directed by Engr in Charge.
S&F MCCB DB VTPN 4 WAYdouble door 240 volts with 125 Amps standard bus bar of suitable size and common neutral link all enclosed in standard sheet flush mounting type, drilling holes for incoming and out going cables complete suitable for ways with IP43 protection complete all as specefied and directed. (Note: MCCB should be B or C curve as directed by engineer in charge)
S&F MCCB , TPN, 240 Volt , 125 amp for fixing in DBs of including proper thimble connections complete all as specified and directed. (Note: MCCB should be B or C curve as directed by engineer in charge)
S&F MCB DB double door 240 volts with 200 Amps standard bus bar of suitable size and common neutral link all enclosed in standard sheet flush mounting type, drilling holes for incoming and out going cables complete suitable for 8 ways with IP54 protection complete all as specefied and directed. (Note: MCB should be B or C curve as directed by engineer in charge)
S&F MCB , SPN, 240 Volt , 40 amp for fixing in DBs of including proper thimble connections complete all as specified and directed. (Note: MCB should be B or C curve as directed by engineer in charge).
S&F MCB, single pole 240 volts 6 to 32 Amp capacity fixing in DB’s including proper thimble connections complete all as specified and directed. (Note: MCB should be B or C curve as directed by engineer in charge)
S&F MCB, single pole 240 volts 40 to 63 Amp capacity fixing in DB’s including proper thimble connections complete all as specified and directed. (Note: MCB should be B or C curve as directed by engineer in charge)
Supply and fixing for sub main wiring two single core PVC insulated and unsheathed cable with 6 Sqmm multi -strand copper conductor drawing in PVC concealed conduit with 6 Sqmm PVC copper conductor cable as in earth wire system ,including taking out old wiring complete all as directed. Note1: Neccessary cutting chasing wherever required and making good the disturbed surface shall be part of job at no extra cost.Note2 : Two runs of 6 sqmm cable alongwith one run of 6 Sqmm PVC insulated unsheathed copper conductor as earth wire, conduit and conduit accessories will be measured as one length).
Supply and fixing for sub main wiring two single core PVC insulated and unsheathed cable with 4 Sqmm multi -strand copper conductor drawing in PVC concealed conduit with 4 Sqmm PVC copper conductor cable as in earth wire system ,including taking out old wiring complete all as directed. Note1: Neccessary cutting chasing wherever required and making good the disturbed surface shall be part of job at no extra cost.Note2 : Two runs of 4 sqmm cable alongwith one run of 4 Sqmm PVC insulated unsheathed copper conductor as earth wire, conduit and conduit accessories will be measured as one length).
Supply and fixing for sub main wiring Four single core PVC insulated and unsheathed cable with 10 Sqmm multi -strand copper conductor drawing in PVC concealed conduit with 6 Sqmm 2 core PVC copper conductor cable as in earth wire system ,including taking out old wiring complete all as directed. NoteNote2 : four runs of 10 sqmm cable alongwith two run of 6 Sqmm PVC insulated unsheathed copper conductor as earth wire, conduit and conduit accessories will be measured as one length).
Supply and fixing earth metal plug and socket single pole and neutral with a two pin and earth plug and socket alongwith one single pole MCB of 20 Amp concealed in wall all as directed by Enineer-in-charge.
Earthing complete with galvanised steel earth plate electrode, 600x600 x 6.0mm thick buried directly in ground(earth pit not less than 2.25m deep below normal level) connected to galvanised earth lead wire 4.0mm dia by means of nuts, bolts, & washers of GI as shown in electrical plate No 3 of SSR Part I. Connected to earthing test point testing complete including necessary earth pit chamber PCC 1: 3: 6 type C1, and 50mm thick RCC 1 : 2: 4 chamber cover and with 8mm dia mild steel re-enforcement of 15Cm C/C spacing both ways with a handle made of 8 mm bar for fitting, galvanised iron funnel, wire mash watering pipe GI 20 mm dia light grade, and protection to earth lead shall be provided with GI pipe light grade 15mm dia up to 7.5m from the earth plate electrode, excavation, charcoal and common salt mixed refilling of soil etc complete all as directed. Test Sheet having Earth resistance value less than 3 ohm will be submitted by contractor.
supply and fixing exhaust fan 250 mm,single phase ac 220 V in PVC body compelete all as specified and as directed.
Excavation in trenches not exceeding 1.5 mtr wide and not exceeding 1.5 mtr in depth for laying of cables including getting out in any kind of soil complete all as specified and directed.
Returning filling in including spreading, levelling, and well ramming, in layers not exceeding 25 cm each layer in any kind of soil.
Removing surplus excavated material from site not exceeding 50 mtrs from starting point and depositing where directed at a level not exceeding 1.5 mtr above the starting point.
M&L for providing river sand as in sand cushioning to under ground cable including punning down of sand in layers as specified and as directed
supply and laying un-reinforced precast concrete cable cover class LV, Type 2, with peak size 300mmx180mmx40mm. complete all as specified and directed by Engr-in-charge.
M&L for galvanized steel tubing 50 mm light garde (ISI marked) inreplacement of old damaged steel GI pipe for protection of cable fixed to pole/walls or laid in floors, road crossing ducts with all necessary fittings and fixed with clamps, bolts, nuts and washers etc complete all as specified and directed.
Supply , laying , jointing and testing XLPE insulated screened armoured heavy duty electric cable with aluminium conductor 1100 volts grade of size 50 Sq mm 3.5 Core with aluminum thimble of same size complete all as directed.
ANIL KUMAR AND CO
AR CONSTRUCTIONS
SWAMI ENGINEERS
Buttar Construction Co.
M/S Mukesh Kumar Gupta
Arneja Builders
stage.html
html • 0.06 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .