Supplying, Installation, Testing and Commissioning of Split and Cassette type Air-Conditioning systems for Labs and Faculties at JIPMER, Puducherry
2026_HITE_287139_1
HITES/FM/JIP/MECH/2026-27/05
Open Tender
Miscellaneous Works
Item Rate
60 days
Puducherry
Please refer Tender Documents
2 documents required · 2 mandatory
₹590
Yes
HITES
₹19,972
Yes
31 Aug 2026
10 Aug 2026
1 Sept 2026
10 Aug 2026
31 Aug 2026
10 Aug 2026
Supplying , Installation, Testing and Commissioning of Air Cooled Hi Wall split type Air conditioners complete with Indoor unit(IDU), Out door unit (ODU), surface / concealed copper Refrigerant piping with insulation (closed cell elastomeric nitrile rubber tubular pipe section) upto 3 Mtr (IDU to ODU), copper power cable upto 3.5 Mtr (IDU to ODU) i/c drain pipe R-32/R-410/ R-407 Green Refrigerant, wireless Remote control, suitable for working between 180-260V with low & high voltage cutoff and 50 hz ,1 phase AC supply capable of performing cooling, dehumidification, air circulation of following capacity with Scroll / rotary compressor. The system shall be able to deliver 100% of the rated capacity upto 42 0C. Min 5 year Original Equipment Manufacturer (OEM) warranty both compressor and Printed Circuit Board (PCB). Must comply : Electrical cable IS 694 or IS 9968 temperature sensing control IS/International Electrotechnical Commission (IEC) 60730, hermetic compressor IS 10617, heat exchanger IS 11329, capacitor IS 2993 and motor IS 12615. Complete as per CPWD specification and IS : 1391 Part II 2023. The system shall be able to operate up to 50 0C (out door ambient temperature).Inverter Type - Cooling only
2.0 TR with 5 Star BEE Rating
1.5 TR with 5 Star BEE Rating
1.0 TR with 5 Star BEE Rating
Supplying, Installation, Testing and Commissioning of Air Cooled Cassette type Air conditioners complete with Indoor unit(IDU), Out door unit (ODU), R-32/R410A/R-407 Green Refrigerant, wireless Remote, inbuilt drain pump, suitable for 400/230V, 50 Hz ,1 /3 phase AC supply, including surface / concealed copper Refrigerant piping with insulation (closed cell elastomeric nitrile rubber tubular pipe section) upto 5.5 Mtr (IDU to ODU), copper power and control cable upto 5.5 Mtr (IDU to ODU) including drain pipe, the system shall be capable of performing cooling, dehumidification, Air circulation, filteration & ventilation of following capacity with Scroll/rotary compressor with min 5 year Original Equipment Manufacturer (OEM) warranty both compressor and Printed Circuit Board (PCB) as specified. The system shall be able to deliver 100% of the rated capacity as per relevant IS Code. The lab testing reports as per IS: 1391 shall be submitted from National Accreditation Board for Testing and Calibration Laboratories (NABL) accredited as per International Electrotechnical Commission (IEC) 17025 standards/Central Power Research Institute (CPRI)/ Electrical Research and Development Association (ERDA)with Original Equipment Manufacturer (OEM) etc. complete as per CPWD specification and as per IS: 1391 as required. (Heating & Cooling)
Supply, installation, testing and commissioning of copper refrigerant piping with 13 mm thick nitrile rubber insulation interconnecting the Condensing unit to evaporating unit for split units as per site condition
Copper refrigerant piping for 2 TR machine of suitable size 5/8" & 3/8".
Copper refrigerant piping for 1 TR & 1.5 TR machine of suitable size 1/2" & 1/4".
Voltage Stabilizer 5 KVA rating suitable for 2TR Split & Cassette AC Units with Overcurrent & Under voltage protection. (The input voltage is 230V ± 10% AC 50 c/s)
Voltage Stabilizer 4 KVA rating suitable for 1TR and 1.5TR Split AC Units with Overcurrent & Under voltage protection. (The input voltage is 230V ± 10% AC 50 c/s)
Supply and installation of 20A-25A 3 pin metal clad plug and socket with 20A-25A MCB with suitable powder coated sheet steel enclosure with fixing accessories etc
Supply and installation of PVC drain pipe ISI marked, connecting the drain lines from the indoor units to floor sump to be concealed / 9mm thickness nitrile rubber insulation for Split units or to be laid as per site required with as may be decided by Engineer-in-charge.
25mm dia
Supplying & fixing of casing N capping along with accessories in surface/ recess (any ISI marked)
Removing of Old Split Units, stabilizers and its related accesories.
Supplying and drawing following sizes of FRLS/HFFR PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required.
3 x 2.5 sq. mm
3 x 4 sq. mm
Supplying and fixing of following sizes of steel conduit along with accessories in surface /recess including painting in case of surface conduit, or cutting the wall and making good the same in case of recessed conduit as required.
No Rupees Only
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.32 MB
Tender documents_Volume1NIT.pdf
Tender Documents • 0.49 MB
Tender documents_Volume2GCC.pdf
Tender Documents • 1.35 MB
Tender documents_Volume3SCC.pdf
Tender Documents • 4.50 MB
Tender documents_Volume4TS.pdf
Tender Documents • 0.44 MB
Volume5BOQ.xls
Other Document • 0.14 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at [email protected].