Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹41.4 LAccepted-AOC | L1 | Accepted-AOC Accepted being L1 bidder | |
| 2 | L2₹47.6 L+₹5.9 L (14.1%)Rejected-Finance NO 3 WD BUILDING JP AGARWALLA ROAD BHARALUMUKH KAMRUP ASSAM 781009 UDYAM AS 03 0009483 | KAMRUP METRO | ASSAM | 781009 | L2 | Rejected-Finance Being higher than L1 | |
| 3 | L3₹50.3 L+₹8.6 L (20.6%)Rejected-Finance | L3 | Rejected-Finance Being higher than L1 | |
| 4 | L4₹50.3 L+₹8.6 L (20.7%)Rejected-Finance | L4 | Rejected-Finance Being higher than L1 | |
| 5 | L5₹51.7 L+₹10.0 L (23.9%)Rejected-Finance | L5 | Rejected-Finance Being higher than L1 |
Tender Value
₹75.5 L
EMD Value
₹1.4 L
Closing Date
21 Aug 2020, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
CE (AF) Shillong Zone
CE (AF) Shillong Zone Elephant Fall Camp Shillong 793009
COMPLETION OF INCOMPLETE WORK FOR PROVN OF RING MAIN SYSTEM OF ELECTRIC SUPPLY AT AF STN JORHAT
2020_MES_359749_1
88498/R and C/JOR
Open Tender
Miscellaneous Works
Item Rate
180 days
GE (AF) JORHAT
As per tender documents
6 documents required · 6 mandatory
₹1,000
GE (AF) Jorhat
₹1.4 L
Yes
17 Sept 2020
9 Jul 2020
27 Aug 2020
9 Jul 2020
21 Aug 2020
7 Aug 2020
9 Jul 2020 - 30 Jul 2020
60 days
Amount
Excavation in trenches , n exc 1.5m wide and n.exc 1.5m in depth for foundation etc and getting out in soft/loose soil all as directed.
Returning, filling in, including spreading, leveling, watering and well ramming in layer not exc 25 cm thick in soft/loose soil complete all as specified and directed.
Removing excavated material to a distance n.exc 50 m and depositing where directed at a level n.exc 1.5m above the starting point all as directed and specified
Taking out XLPE insulated armoured, heavy duty electric UG cable with alluminium conductor, 11000 volts grade of cross sectional area 95 sqmm, 3 core all as specified and directed.
Supply and laying in trenches, ducts XLPE insulated, screened , PVC bendded , galvanized steel wire armoured heavy duty 11000Volts garde, HT,FRSL with PVC inner and outer sheathed , of size 3Core, 95Sqmm with stranded aluminum conductor (earthed) cable, conforming to IS 7095(Part-II) All as specified and directed (The quoted rate shall be deemed to include the following factors:-) (Note: 1. The routine test of cable shall be witnessed by the representative of Accepting Officer at manufacturer’s factory premises. 2. All the lot shall be marked with GE(AF) Jorhat in every 5meter length. 3. Purchase Vouchers, Gate pass, and test certificate is to be submitted to the GE. 4. Commissioning tests as required will be conducted at work site and inspected by EI of Accepting officer. 5. Earth work, excavation, cable protection with sand/brick, GI duct shall be measured and paid separately)
Bricks sub class ‘B’ locally available best quality laid in trenches over sand cushioning for cable protection complete as specified and directed.
M&L for HDPE pipes class PN 10 of 100mm bore of pressure rating 1Mpa for cable protection complete all as specified and directed.
Dismantling and taking out Unserviceable gang operated device including DO assembly complete all as specified and directed.
M&L for Plain cement concrete 1:3:6 type C2 (using 40mm graded stone aggregate) as in foundation for poles/ stay assembly etc complete all as specified and directed.
Supply and installation of HT 12 KV SF-6insluted metal enclosed outdoor type RMU with standard metering unit having digital display,3phase,50 Cycle Rated STR: 12kA/3Sec, Rated Bus bar Current : 630A,3Way(2Nos ;load break switches and 01 No. of 630 amp vaccum “T” Off circuit breaker) with self Powered (3 O/C & 1E/F) relays with in built 11 KV CT’s 03 Nos) having CT ratio 50/1 accuracy class 1.0 of metering and 5P10 for protection purpose & 11 KV resin cast PT’s 03 Nos. The RMU unit should be designed, manufactured and tested according IEC 60694,IEC 62271-102,IEC 62271-100, IEC 62271-200, IEC 60265-1, IEC 60529. The ring main unit comprises the following :-
Item No. 10.00 Contd... (a) Load Break switch should have the following:- Manually operated 12KV 630A, Load break switch and earthing switch with amking capacity. –“Live Cable” LED indictors through Capacitor Voltage Driver mounted on the Bushings. - Mechanical ON/OFF/Earth indication. - Cable testing facility without disconnecting the cable terminals. - Anti reflex operating handle. - Cable box suitable for cable termination of 1no 3Cx95 Sqmm XLPE cable. - Cable door should be arc proof and interlock with respective earthing switches for safety of operation, it should not be possible to open the cable and the cable door unless the earth switch is ON.
Item No. 10.00 Contd... (b) Circuit breaker should have following each circuit breaker:- - Manually operated 630 A VCN and eathing switch with amking capacity. - Anti reflex operating handle. - Fault arc interruption should be in vacuum only. - Auxilary contact 2NO and 2NC. - -3O/C +1E/F self powered relay with l;ow and high set of over current and earth fault. Relay should have facility to trip the breaker from remote commands without requiring shut trip coil. Relay type J603 of ABB or equivalent. - Mechanical ON/OFF/Earth indication. - Cable box suitable of cable termination of 1 No. 95Sqmm 3 Core XLPE cable.
Item No. 10.00 Contd... (c) Metering:- ( to be provided in separate chamber.) - 3 phase digital Amn meter for 0-100 Amp including extra CT-3 Nos of of suitable ration for metering -1 set. - 3Phase digital volt meter for 0-12Kv-01No. - Resin cast PT 01 set of 03Nos. - Multi function meter for measurement of V.A<F KVA ,Pf -01No. - RYB indicators -1SET - Manometer is essential to check the healthiness of the unit -01No. - FPI(Fault passage indicator )-1Set Note:- 1. The RMU shall be tested as type test, routine test ad per IS in presence of GE/his rep. 2. The contractor shall submit QAP(quality assurance programme) within 15days after placement of order forRMU testing in factory. RMU shall be despetched only after inspection clearance by inspecting officer. 3. The contractor shall get prior approval of GE for the make of the RMU they plan to procure. 4. Prior ot manufacture, the general arrangement drawing design details of thye RMU shall be got approval from GE. 5. Commissioning test as required will be condi=ucted at work site and inspected by EI deputed by the Accepting officer. 6. PCC foundation as per manufacture’s instruction shall be deemed to be include in quoted rate.
S&F cable jointing kit for 11KV (earthed) grade cable for indoor termination, cold shrinkable type end joint complete with jointing material and accessories suitable for 95 Sqmm 3 Core XLPE armoured aluminium conductor cable compete all as specified and ditected.
Earthing complete with copper earth plate electrode 600x600x3.15mm buried directly in ground(earth pit not less that 2.25mm deep below ground level) with top edge of the plate not less that 1.5mm below normal ground level connected to 20x3 mm copper earthing strip and main earthing strip upto 7.5mm from testing point fixed by means of iron or steel nuts checknuts and washers, copper earthing strip protected by 25mm bore light grade galvanized iron pipe and other end connected to earthing test point including funnel with watering pipe of 20mm bore light garde galvanized iron pipe, wire mesh, charcoal or coke and common salt in alternate layer of 15cm(compacted thickness) all around the earth electrode with concrete earth pit in PCC(1:3:6) type C-1, cast iron frame, 50mm thick pre-cast RCC 1:2:4 type B1 cover slab set in 1:4, reinforced with 8mm dia TMT bar 10cm C/C and suitable habdle of 10mm dia round bar, including necessary excavation, earth work in soft/loose soil to a distance n.exe 50 m and necessary testing complete all as shown in Electrical plate No3 of MES SSR Part-I 2009. (Note :- Earth strip and 25mm dia GI protection pipe upto 7.50meter length shall be measured in the unit rate)
S&F copper strip 25x3 mm for connecting the equipments with running copper earth strip connecting with nuts , bolts, washers and copper thimbles complete all as specified and directed.
Supply, install, testing and commissioning of totally enclosed KOISK box 90x90x75Cm, dust and vermin proof suitable for 11Kv 3Phase, made out of 3.15mm thick CRCA sheet and built upon rigid frame work having front and rear hinged door with neoprene rubber gasket including plate, earthing strip point and bottom detachable gland plate complete with suitable size of zinc/chromium plated and nuts, bolts and washers etc. The aluminum bus bar having 400 Amps capacity-03 Nos. supported with suitable size of high strength SMC/DMC material insulator with suitable size of brass nut, bolts and washers with heat shrinkable PVC sleev. The KOISK shall be powder coated and degree of protection shall be of IP-66. The panel shall be embedded with 50x50x6 mm MS angle iron frame and 60Cm above the normal ground level including all necessary PCC work completeall as specified and as directed.
(SCHEDULE OF CREDIT) Note :- Amount of Rs. 30580.00 indicated in Tender shall be deducted from the total quoted amount of BOQ.
PURBANCHAL BUILDERS
M/S SANTOSHI TRADERS
M/S PAUL CONSTRUCTION
M/S PS ENTERPRISE
SRI HARSHITA ELECTRICALS
THE SUPPLY AGENCY
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .