Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹30.3 LAccepted-AOC NEAR INDUSTRIAL ESTATE THANDA PADDAR UDHAMPUR J K 182101 | UDHAMPUR | JAMMU AND KASHMIR | 182101 | ₹30.3 L Quoted ₹32.5 L | L1 | Accepted-AOC BEING LOWEST BIDDER |
| 2 | L2₹32.9 L+₹38,134.54 (1.17%)Rejected-AOC CHHURTA JHAJJAR KOTLI JAMMU J K 181222 | 181222 | ₹32.9 L+₹38,134.54 (1.17%) | L2 | Rejected-AOC 2ND LOWEST BIDDER |
| 3 | L3₹34.5 L+₹2.0 L (6.13%)Rejected-AOC DAYA BAGH SATTANI DHAR ROAD UDHAMPUR DISTT UDHAMPUR J K 182101 | UDHAMPUR | JAMMU AND KASHMIR | 182101 | ₹34.5 L+₹2.0 L (6.13%) | L3 | Rejected-AOC 3RD LOWEST BIDDER |
| 4 | L4₹35.8 L+₹3.3 L (10.2%)Rejected-AOC | ₹35.8 L+₹3.3 L (10.2%) | L4 | Rejected-AOC 4TH LOWEST BIDDER |
Tender Value
₹39 L
EMD Value
₹78,000
Closing Date
8 Dec 2022, 6:00 pmClosed
GE(ARMY) DHAR ROAD
GE(ARMY) DHAR ROAD
REPAIR AND MAINT OF INTERNAL ELECTRIFICATION ACS GEYSER CEILING FAN REFRIGERATOR DEEP FREEZERS EXTERNAL ELECTRIFICATION AND OTHER CONNECTED WORKS AT JAKLI RTC DHANSAL ANDREPAIR OF DRAINAGE CULVERT AND PATHWAYS AT JAK LI RTC DHANSAL UNDER GE (ARMY) DH
2022_MES_562418_1
8068/NIT-53/2022-23
Open Tender
Civil Works
Item Rate
240 days
DHANSAL
Please refer Tender documents.
6 documents required · 6 mandatory
₹500
GE(ARMY) DHAR ROAD
₹78,000
Yes
15 Feb 2023
10 Nov 2022
10 Dec 2022
11 Nov 2022
8 Dec 2022
25 Nov 2022
Amount
Taking down old unserviceable/deteriorated batten/PVC conduit point wiring aluminium/ copper from existing place i.e. light, fan, socket or power points complete with all unserviceable fittings such as switches, sockets,bell push , ceiling rose, pendants, Holders, etc and making good all disturbed surface to wall, floor etc by means of cement mortar (1 : 3) or plaster of Paris and to match / finish new surface as the existing surface either by using same colour distemper, Putti or white / colour wash all as required and directed by Engineer-in-Charge.
M & L for concealed point wiring on wall and ceiling/roof with necessary fixing arrangements with PVC-FRLS insulated and unsheathed copper multi-stranded conductor of size 1.5 Sqmm, 1100 volts grade drawn in and including rigid non metallic white / ivory PVC conduit medium grade ISI marked not less than 20 mm dia with all conduit accessories/ fittings such as junction boxes, bends, tee, elbow etc including anodized MS sunken boxes made out of MS sheet of thickness not less than 1.6 mm with earth dolly and Bakelite laminated sheet 3mm thick ISI marked for fixing of switches / sockets, fan regulators, wall mounting fittings, door bell & bulkhead etc with MS screw and cup washers including PVC-FRLS insulated and unsheathed copper multi-stranded conductor of size 1.5 Sqmm, 1100 volts grade for continuous earthing including cutting the chases and making good the surface by cement mortar (1:3) and for matching / finishing of new surfaces either by means of plaster of peris/ Putti or distemper / colour wash with same existing colour surfaces all as specified and directed by Engineer-in-Charge for the following:-
One light /Fan/Bell point controlled by one switch 6/5 Amp one way single pole.
One 3 pin socket outlet 6/5 Amps controlled by one switch on the same board with other switches.
One 3 pin 6/5 Amp socket outlet controlled by one switch independent board.
All as per item No 2 here-in-before but for power point wiring with 2.5 Sqmm PVC-FRLS insulated, unsheathed, copper conductor, stranded 1100 volt grade cable and 1.5 Sqmm PVC-FRLS insulated, unsheathed, copper conductor, stranded 1100 volt grade cable as continuous earth lead.
S&F switch piano flush type (ISI marked), single pole, one way 6 Amp, 240 Volts complete all as specified and as directed.
S&F switch piano flush type (ISI marked), single pole, one way 16/15 Amps, 240 Volts including complete all as specified and as directed.
S&F socket outlet 3 pin, 6 Amp piano flush type including complete all as specified and as directed.
S&F socket outlet, 2 in 1, 3/5 pin 6 / 16 Amp, piano flush type complete all as specified and as directed.
S&F bell push 5/6 Amps SP flush type complete all as specified and as directed.
S&F ceiling rose, surface bakelite, 65mm x 50mm, two to three terminals complete all as specified and as directed.
S&F for batten angle lamp holder insulated body with back plate suitable for batten fittings including complete all as specified and as directed.
S&F Ding dong sound door call bell electric AC 240 volt, 50 Hz ding dong type including taking down unserviceable complete all as specified and as directed.
Supply & Fixing medium step type fan regulator , 240 Volt AC, socket size, medium step 120 watt ISI marked complete all as specified and directed.
M & L for sub main wiring in replacement of worn out aluminium conductor wire with two run of FR PVC insulated unsheathed flexible copper conductor (Multistrands), single core of size 4 Sqmm, 1100 Volts grade and one run of 2.5 Sqmm FR PVC insulated unsheathed as earth (In Green Colour), flexible copper conductor (Multistrands) for continuous earthing conforming to IS 694 with latest amendments and including drawing in PVC rigid conduit not less than 20 mm dia ISI marked medium grade incl fitting like bends, elbow, junstion box, reducer, junction boxes, tee bell mouth all fixing accessories such as coupler lock, nuts, saddles pipe hooks etc complete including Cutting & Chasing required on brick wall not exceeding 10 CM girth for concealed conduit wiring and making good to disturbed surface with cement mortar 1:3 and distemper / colour wash etc to match with existing surfaces including facing / finishing complete , connecting incoming / outgoing electric connections by using required size copper lugs / thimbles and making good the disturbed surface to match with existing complete in all respect all as specified and directed. Note :- 1. Two run of single core cable with one run of contineous earth wire of copper conductor wire Flexible (Multistrand) of FR PVC insulated and PVC conduit pipe with fitting shall be measured and paid as one unit length.
Supply & Fixing in replacement of old unserviceable DB by SPN Distribution Box, double door of protection grade IP 43 in fine powder coated, matt finish with best CRCA sheet, fitted with shrouded neutral, insulated pin type copper bus bar, Din rail, earth bar of 4 way, confirming to IS 13032 & 8623 complete all as specified and directed.
Supply & Fixing in replacement of old unserviceable DB by SPN Distribution Box, double door of protection grade IP 43 in fine powder coated, matt finish with best CRCA sheet, fitted with shrouded neutral, insulated pin type copper bus bar, Din rail, earth bar of 8 way, confirming to IS 13032 & 8623 complete all as specified and directed.
Supply & Fixing in replacement of old unserviceable DB by SPN Distribution Box, double door of protection grade IP 43 in fine powder coated, matt finish with best CRCA sheet, fitted with shrouded neutral, insulated pin type copper bus bar, Din rail, earth bar of 12 way, confirming to IS 13032 & 8623 complete all as specified and directed.
Supply & fixing in replacement of AC/Geyser box by sheet steel enclosure in single pole and neutral fitted with two pin and earth plug and socket complete with one single pole MCB, 240 volt, 20 Amps , 'C' series of suitable rating complete all as specified and directed .
Supply & Fixing MCB SPN, 32 Amps 240 volts, AC , 10 KA breaking capacity 'C' Series,"ISI marked and conforming to IS 8828/IEC 60898-1 complete all as specified and directed.
Supply & Fixing MCB SP, 05 to 32 Amps 240 volts, AC , 10 KA breaking capacity 'C' Series,"ISI marked and conforming to IS 8828/IEC 60898-1 complete all as specified and directed.
S&F Wall mounted LED batten 18 Watt with 01 No LED tube rod, extruded aluminium heat sink provided for efficient heat dissipation and integrated electronic driver including dismantling taking down unsv FTL fitting T8 type any type complete all as specified and directed.
S&F LED building security light 35 watt, 230V complete with all accessories and including connecting up to ceiling rose with 0.5 sqmm three core copper flexible conductor cable, One GI medium grade suitable size dia bracket of total length 50 cm and fixed to wall with 2 Nos MS Clamp and fastener incl dismentling taking down unsv fitting any type all as specified and directed.
S&F Bulk head fitting 10 watt LED incl water proof , weather proof all as specified and directed in replacement of old unserviceable filling .complete all as directed by engr-in-charge.
Supplyand fixing LED lamp 12 watt, CDL, B-22 cap, (Pin type), 230V, PF-0.95 (min) incl dismentling taking out unsv CFL/LED Bulb. complete all as directed by engr-in-charge.
S & F service connection with twin core 10 Sqmm 240 volt heavy duty un armured PVC insulated stranded aluminium conductor cable with GI supporting wire of suitable size in replacement of old unseriveable conductor cable complete.
Excavation in trenches not exceeding 1.5 meter wide and not exceeding 1.5 meter in deep getting out in hard/dense soil for stay assembly/laying of cable/errection of poles etc complete all as specified and directed.
Returning, filling in including spreading, levelling, watering and well ramming in layers n.exc 25cm thick.
Removing of excavated material n.exc 50m and depositing where directed at a level n.exc 1.5m above the starting point.
M&L PCC (1:2:4) type B-1 using 20mm graded aggregate as in coping of new pole / reconstruction old damaged copings etc, including necessary form work complete all as specified and directed
M & L for dry Sand cushioning in trenches for protection of cable including watering and consolidation all as specified and directed.Note: Punned thickness shall be considerd for measurment purpose
M & L for well burnt brick sub class B old size laying in trenches perpendicular to axis of the cable complete all as specified and directed.
Supply and laying in trenches/Floor or fixed to Pole/Wall GI pipe light grade with fitting of size 80 mm bore for protection of cable including dismantling existing pipe complete all as specified and directed by the Engineer-in-Charge.
M&L for cutting of PCC/Hard standing/WBM road not exceeding 20 cm in width not exceeding 30 cm in depth for passing of LT cable and making good of disturbed surface to match with the existing surfaces by using old and new material i.e bitumen/PCC (1:3:6) type C-1 complete all as specified and directed .
Taking out existing worn out/old PVC insulated cable in 3.5 core of 185 sqmm to 95 Sqmm size of 1100 Volt grade in pieces from trenches making loop for transportation and removal from site after taking proper shut down from MES competent staff complete in all respect and as directed at site.
Taking out existing worn out/old PVC insulated cable in 3.5 core of 70 sqmm to 35 Sqmm size of 1100 Volt grade in pieces from trenches making loop for transportation and removal from site after taking proper shut down from MES competent staff competentlete in all respect and as directed at site.
Taking out existing worn out/old PVC insulated cable in 4/2 core of 25 sqmm to 10 Sqmm size of 1100 Volt grade in pieces from trenches making loop for transportation and removal from site after taking proper shut down from MES competent staff competentlete in all respect and as directed at site.
Material and labour for fixing or passing through pipe, laid in trenches or fixed to pole/wal or fixed to LT panel board, 1100 volts grade heavy duty cable with PVC insulated stranded aluminium conductor served with inner sheathing of PVC tape, armoured with galvanised steel wire or tape and overall PVC sheathed 35 Sqmm 3.5 core with required aluminium cable lugs all as specified and directed.
-- do-- as per item no. 36 above but size 95 sq mm 3.5 core
-- do-- as per item no. 36 above but size 25 sq mm 4 core
-- do-- as per item no. 36 above but size 10 sq mm 2 core
Taking out existing worn out/old PVC insulated cable in 3 core of 95 Sqmm to 120 sqmm size of 11000 Volt grade in pieces from trenches making loop for transportation and removal from site after taking proper shut down from MES competent staff complete in all respect and as directed at site.
Supply & laying HT XLPE Insulated screened aluminium stranded conductor cable PVC bedded galvanized strip armoured heavy duty 11 KV cross sectional area 95 Sqmm 3 Core (Earthed)conforming to IS 7098 lead in duct/trenches complete all as specified and directed
S&F sheet metal enclosure box made out of 3.15 mm thick CRCA sheet with powder coated paint (CPRI approved) double door outdoor type including solid aluminium bus bar of capacity 100 Amp 4 Nos strip with locking arrangements, enclosure box to be fixed on plinth foundation 1:2:4 and 150 mm above ground level including MS angle/ channel consisting of necessary fixing arrangements for incoming & out going cables with cable glands, lugs, nut, bolts, washers and fixing arrangement , PCC work including necessary flat iron clamps with nuts, bolts & washers and Powder coated all as specified and directed..Including taking down old unsv
Supply and Fixing cable jointing kit for 11 KV (earthed) grade cable for outdoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 95 Sqmm.Including taking down old unsv .
Supply And Fixing cable jointing kit for 11 KV (earthed) grade cable for straight through heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 95 Sqmm.Including taking down old unsv.
Dismantling and taking down old/unsv insulator of any type any size from pole/stay complete all as specified and directed.
S&F pin type, porcelain, vitreous, brown, including one galvanised mild steel spindle, two galvanised iron washer and one galvanised iron nut, 100mm height and 65 mm dia for 1100 volts grade all as specified and directed.
S&F shackle type,porcelian vitreous white, brown or green insulator including galvanised mild steel straps, washers, insulators bolts ,washer and nuts of size 100 mm height and 115 mm dia for 1100 Volts grade complete all as specified and directed.
S&F Loop type insulator, porcelian vitreous brown of size 65x90mm and clearence hole 16mm all as specified and directed.Including dismantling and taking down.
S&F Disc type insulator porcelain, vitrous 145mm high and 255 mm dia ball and socket type white, brown or green single disc with tension clamp for conductor for working pressure voltage 11000 V.
M & L triple pole mechanically operated GOD mounted on insulators and steel frame with operating mechanism worked from ground level 11000 volts grade of current carrying capacity up to 200 Amps complete incl removing the existing U/S one.
S&F in Replacement of MCCB 250 Amps 4 Pole, 25 KA, 415 V, 50 Hz complete all as specified and directed.
S&F in Replacement of but MCCB 200 Amps 4 Pole, 25 KA, 415 V, 50 Hz complete all as specified and directed.
M&L for trimming of branches of trees touching LT/HT electric over head line and making clear about 3 mtr in radius by climbing up tree or by providing ladder, at a height 7 mtr and above and carrying and depositing where directed not exceeding 50 mtr.
Dismantling taking down unserviceable flood/street/post top lantern/gate light fitting any type any capacity from Pole/Building for replacement complete all as specified and directed.
S&F Supply and fixing post top lantern LED type 40 watt 230 watt volts AC outdoor type with decorative post top for 360 degree indirect light IP 65 protection with impact and corrosion resistant complete with driver and lamp complete .
Servicing, repairing, overhauling and testing of Voltage Stabilizer of capacity upto 50 KVA by disconnecting the incoming and outgoing connection strip opening the stabilizer complete for taking out the unserviceable servo motors, auto control, circuit plates, dimmer and switches, voltmeter with switches and replace the following and testing on full load as directed by the Engineer-in-Charge for the following Capacity :-(a) Servo motor as per existing size - 01 No, (b) Voltmeter 0 to 500 Volts with switch. - 01 No, (c) Voltage on off adjusting switch (Auto control Switch), (d) Supply and pouring transformer oil after dehydrating the sump - 50 Ltrs, (e) Roller Wheels as per existing size - 01 Nos, (f) Voltmeter 0-300 Volts - 03 Nos (g) Supply and fixing of dimmer 50 KVA -01 Nos (h) Shifting of stablizer from Jhajjar Nallah to Approachable road and further to workshop will also consider in thi s job complete all as specified and directed by engr in Charge.
Supply,fixing, connecting, testing and commissioning LED street light fittings 70 Watt ,240 VOLT, current 0.31 Amps, 5700 Temp, new generation energy saving & environmental friendly long life versatile pressure die-cast aluminium IP66 road luminaire with high power LEDs as light source and electronic driver.Including taking down old unsv one. Make -Crompton/WIPRO/Havells/Phillips as approved by GE. Note : (i) A certificate of Gurrantee shall be submitted by the contractor for period 3 (three) years from the certified date of completion of work as a whole for repair/replacement of lamp & light fittings to GE. Performance guarantee amount @ 5% of quoted amount of LED lamps & light fitting shall be kept reserved for a period of three years. Atlernatively after completion of work contractor may furnish guarantee amount in the shape of FDR/BGB pledged in favour of GE. (ii) Luminarie shall be provided with all parameters mentioned above.
Supply,fixing, connecting, testing and commissioning LED flood light fittings 120 watt ,240 volt, 0.57 Amp current, > 0.95 PF, 5700 K Temp ,new generation energy saving & environmental friendly long life versatile pressure die-cast aluminium IP66 road luminaire with high power LEDs as light source and electronic driver. Make Crompton / WIPRO/ Havells /Phillips.Including taking down old unsv one. Note : (i) A certificate of Gurrantee shall be submitted by the contractor for period 3 (three) years from the certified date of completion of work as a whole for repair/replacement of lamp & light fittings to GE. Performance guarantee amount @ 5% of quoted amount of LED lamps & light fitting shall be kept reserved for a period of three years. Atlernatively after completion of work contractor may furnish guarantee amount in the shape of FDR/BGB pledged in favour of GE. (ii) Luminarie shall be provided with all parameters mentioned above.
Supply and fixing LED Solar street light fitting 15 Watt , including solar panel, charge controller with dusk down sensor complete.Color Temperature 6500K, Rating IP 65 ,including taking downold unsv one. Note- (i) Solar Lightof 15 Watt (Make - Crompton/Wipro/Havells/Phillips) -01 Nos (ii) Solar Panel-01 Nos (iii) Sensor-01 Nos (iv) Charge Controller-01 Nos (v) Lithium-ion Battery-01 Nos. are to be included in above deemed quoted rate.
Servicing of transformer any type,any make 11000 Volts / 433 Volts step down/step up, indoor/out door type of capacity upto 200 KVA comprising following work services :- (a) Disconnection of cable termination of HV & LV ends. (b) Opening of top cover by removing nuts, bolts and all mounting accessories and conservator tanks for visual inspection. (c)Checking of HV/LV insulators including internal inspection (d) Replacement of corroded nuts/bolts with double washers, burnt lugs, etc by new one (e) Servicing of tap changing gears by cleaning and polishing tapping contact points. (f) Removing, cleaning, polishing of bushings and studs of both HV/LV side by using soft cotton cloth including checking for cracking and refixing the same. (g) Refixing all cable terminals HV & LV sides and transformer top cover, conservator tank and other fitments in position. (h) Cleaning and heating of silica gel in breather. (j) Connecting HV & LV side with existing incoming and outgoing cables including re-connection of earth strip/lead. (k) HV side cable connection shall be made with new HV tape & M Seal Monoplast as required at site. (l) All marshalling boxes to be cleaned from inside. (m) All the terminal connection of control and relay wiring to be checked and tighten. (n) Examine the rollers carefully includes greasing them properly. (o) Checking of earthing connection and tightening nuts& bolts with ensuring the earthing system working properly. (p) Location- Jhajjar Nallah, Old Cook House, Power House. Note:1. Any serious faults /defect to be carried out under this item and material required shall be measured and paid separately under respective item.
De-hydration/ filtration of transformer oil by hiring on line filtration plant to achieve di-electric strength not less than minimum 50 KV including following work services :- (a) Removal of all suspended particles such as dust, rust, scales, collided carbon oxidation sludge etc upto < 1 micron. (b) De-hydration of transformer oil under vaccum. (c) Circulation of heated oil and filling of treated oil in transformer tank. (d) Top up the transformer oil upto the level NOTE : (i) Contractor shall use the vehicle mounted filtration plant with new suitable size heavy duty hose pipe. (ii) The transformer oil required for replacing/top up shall be measured and paid separately as "Supply only" (iii) Conducting field testing of di-electric strength of the transformer oil before and after filteration (iv) Checking the megger/earth resistance values with battery operated megger of 5 KV
M&L for Filling / topping of new transformer oil having dielectric strength not less than 60 KV complete including centrifuging of oil (if required) up to getting dielectric strength not less than 60 KV all as specified and directed by the Engineer-in-Charge Make:- Power oil & Equivalent approved by GE
Rectifying and arresting the oil leakage of transformer of any capacity, disconnection of cable termination of HV& LV ends , opening the top cover by using tripod, chain and pulley after removing all fitments, replacing the components of the transformer such as gaskets, "O" rings etc. Rectify the leaks in a variety of areas such as radiator fins, flanges, circuit breakers, valves, fastener assemblies, Oil leakage through pin hole / crack joint , drain valve / radiator valve , Oil leakages through gasket joints. Applying putty/M-Seal Monoplast where ever necessary. Refixing the top cover and all fitments, refixing cable termination of the HV& LV ends, testing complete all as specified and as directed. NOTE :- Cost of all type of gasket, "O" rings, putty/M-Seal Monoplast, lugs, nuts, bolts, double washers etc shall deemed to be included in the quoted rate.
Supply only breather assembly of Transformer with new silica gel upto 200 KVA transformer as per existing make and type complete all as specified and as directed.
Supply only brass terminal stud with nuts, check nut, oil seal and washer for HV side of transformer of any make ( as per sample) up to 200 KVA transformer complete all as specified and as directed.
Supply only brass terminal stud with nuts, check nut, oil seal and washer for LV side of transformer of any make (as per sample) up to 200 KVA transformer complete all as specified and as directed.
Supply only bushing of HV side as per existing size/Model of the capacity up to 200 KVA transformercomplete all as specified and as directed.
Supply only bushing of LV side as per existing size/Model of the capacity up to 200 KVA transformer complete all as specified and as directed.
M&L for painting of transformers capacity up to 200 KVA including HV/LV side marshalling box with one coat of synthetic enamel paint by using spray painting method including cleaning of existing surface of all dirt and greasy materials alongwith marking of SM/MES Nos with sticker letters n. exc 2 cm height at appropriate places complete after isolating the transformer from the electric supply and to be earthed all as specified and as directed.Location- Jhajjar Nallah, Old Cook House, Power House.
Disconnecting LT/HT connection and earthing strip connection of the transformer/stablizer upto 200 KVA and transportation upto workshop for repair and disconnecting , dismantling and complete overhauling of 11/0.433 KV distribution Transformer any capacity after drain out of transformer oil and kept in close containers for re use, lifting/removing of top cover of transformer and cores with chain pully blocks/crane, cleaning of sludge and washed down with the help of spray of clean oil and re-assembling of transformer with S & F of new gasket set assembly, replacement of nuts, bolts and washers, as required at site, re filling of Transformer oil after centrifusing at satifactory dielectric strength complete after electric connections and testing all as specified and as directed . Note :- (i) If any minor items is required for smooth functioning of transformer including general cleaning of of equipment also, the cost of the same will be deemed to be included in the unit rate. (ii) Cost of transportation up to workshop & back and installation after repair including electric/earth connection is deemed to be included under quoted rate. (iii) If retrieved transformer oil's die-electric strength is very less than it will be replaced with new one under relevent item. (iv) Transformer oil filteration/topping up shall be measured and paid separately. (v) Location- Jhajjar Nallaha and Power House Dhansal.
M&L for rewinding with supper enameled double paper covered copper wire/ strip for HV/LV (11/0.433KV) winding having existing size and giving proper insulation and de-moisturizing before assembling the winding core and including primary testing, ratio testing, no load testing, core insulation testing including taking out unserviceable winding wire complete all as specified and as directed. Note : Rewinding and testing on load of transformer to be carried out through approved firm.
M&L for preparing scraping the old painted surfaces on two pole structure and applying two coat of aluminium paint on steel tubular swaged poles HT 11 mtrs long and bracket, channels, angles,GOD including making/pasting three nos cricular strips of 300 mm wide yello & black colour with synthetic reflected enamel paint and marking /stencil writing of pole numbers with black paint after taking proper shutdowm\n from Competent MES Authority complete and all as specified and directed.
Surface dressing not exceeding 15 cm deep and getting out in soil including cleaning away all grass vegetation saplings, bush under grouting, roots etc and removing rubbish to a distance of 50 M outside the periphery of area complete all as specified and as directed. Location:- Jhajjar Nallah Pump House area, Old Cook House Area, Power House Area,Filteration Plant Area.
M&L for preparing scraping the old painted surfaces on sign board and applying two coat of White paint on Sign Board 1.5 mtr wide and 1 mtr long along with angles of hieght 2 mtr including making Danger Sign on board by painting with RED synthetic enamel paint and complete and all as specified and directed.
Taking down for servicing of split / window type AC 1.5 Ton Capacity including cleaning of cooling coil, air filters/plasma filters etc., (Indoor unit), condenser, compressors, fan motor etc., (Out door unit) with vacuum cleaner OR cleaning solution including checking the servicibility of electrical/electronic circuits relays, wiring kit, thermostat switches knobs, Remote control unit, fan, blower, etc., and keeping the AC unit in satisfactory working condition all as specified and as directed by Engineer-in-Charge. Note :- 1. Replacement of defective spares will be measured & paid separately under relevant items
Supply and fixing following defective spare parts of Split AC unit of Cap 1.5 Ton against item No-75 :-
(a) Supply and fixing Running capacitor 36 MFD Make : Bentex/Delcon/Havells
(b) Supply and fixing Running capacitor 45 MFD Make :- Unistar/Asian/Havells
(c ) Supply and fixing Starting capacitor 100-120 MFD Make:- Bentex/Delcon/Havells.
(d) Supply and fixing Starting capacitor 120-150 MFD Make :- Bentex/Delcon/Havells
(e) Supply and fixing Starting Relay 1022/ 1622 Make :- Renutral/ Sri Ram/Micro Tech
(f) Supply and fixing Starting Relay 2000 Make :- Renutral/Sri Ram/Micro Tech
(g) Supply and fixing Thermostat switch 2059/2064/2054 Make :- Indfass.
(h) Supply and fixing Main printed circuit board (PCB) with electric accessories and sensors suitable for split AC 1.5 Ton capacity
(i) Supply and fixing Condenser fan blade for spilt Type A.C Cap 1.5 Ton made of Plastic.As pes sample
(j) Supply and fixing Copper filter double capillary pencil type.as per sample
(k) Supply and fixing Wiring kit for A.C Window/split Type 1.5 ton as per sample
(l) Supply and fixing Remote control for split AC Cap 1.5 TR of any make as per site requirement
Taking down unserviceable copper pipe of size 1/4" and supply & fixing new copper pipe 1/4" complete including brazing, welding, but bolts and screws of reqd size complete all as directed by Engr-in-Charge
Description all as per item No 77 above but size 1/2"
Material & labour for detecting the leakages of gas of split type AC capacity 1.5 from any location and rectified/stopped the leakages by gas welding or by any other manner and make it function all as directed by Engr-in-Charge
Charging of Gas in Refrigerator, Water Cooler, Air Conditioner, Deep Freezer of any make of under mentioned Gas
Disconnecting from mains and Taking down for servicing of Water Cooler of Capacity up to 180 Ltrs including cleaning of cooling coil, condenser, compressors, fan motor etc with cleaning solution including checking the servicibility of electrical/electronic circuits relays, wiring kit, thermostat switches knobs, fan and blower, etc., and keeping the Water cooler unit in satisfactory working condition all as specified and as directed by Engineer-in-Charge. Note :- 1. Replacement of defective spares will be measured & paid separately as Supply and fixing
Supply and fixing following defective spare parts of Water cooler unit of Cap up to 180 Ltrs against item No-81.
(a) Supply and fixing Over load protector device for up to 180 Ltr Cap. Water Cooler. Make : Sidwal / Usha / Blue star.
(b) Supply and fixing Over load protect device for 180 Lts Cap. Water cooler. Make : Sidwal / Usha / Blue star.
(c) Supply and fixing Starting relay open type/Box type suitable for up to 180 Ltr. Make : Sidwal / Usha / Blue star.
(d) Supply and fixing Starting Capacitor 80-100 MFD Make : Unistar/Bentex
(e) Supply and fixing Running Capacitor 25 MFD Make: Unistar/Bentax.
(f) Supply and fixing Condenser fan blade plastic for Motor 1/32, 1/35 .
(g) Supply and fixing Copper filter pencil type single / Double Capillary.
(h) Supply and fixing Self closing/pushtaps for water cooler Cap up to 180 Ltr.
Supply and installing it by the company made new sealed unit compressor suitable for 180 Ltr Water Cooler alongwith test Certificate from manufacturer including one year gurantee period, cleaning of condenser by machine doing vacum the fully system & testing as directed by Engr-in-charge. Make Tecumsha /Voltas/Sidhwal / Blue star / Godrej.
Disconnecting the electric mains and Taking out unserviceable condenser fan motor 1/10, 1/16 HP from water cooler cap up to180 Ltr and supply and replace with new motor single phase AC 220 V of same Cap including reconnecting the electric connections and testing . Make : AUE, Cromption Greaves / Cool Master as directed by E-in- Charge.
Disconnecitng the mains and Taking out the unserviceable condenser coil fins type and S&F new condenser coil fins type as per existing size & patterns for Water/Coolers Cap up to180 Ltrs.
Dismantling the evaporator/cooling coil of water cooler capacity up to180 Ltrs, checking the leakages of gas and rectify the leakages by gas welding or as other manner and refixing as directed by Engr-in-Charge.
Taking out the Water Cooler Tank from water cooler up to180 ltrs cap & repair the tank with brazing welding etc to stop the leakage of tank incl provn the inserting glass wool tarpaulin sheet etc and repair to cooling coil and refixing as per original position & testing and commissioning
Supply and Fixing of PVC connections 15 mm dia bore with PTMT nuts of length 900 mm including taking down the unserviceable PVC connections.
Disconnecting from mains and Taking down for servicing of Refrigerator/Deep freezer of Capacity 165 to 310 Ltrs including detecting the leakage of gas, cleaning of cooling coil, condenser, compressors, with vacuum cleaner or cleaning solution including checking the servicibility of electrical/electronic circuits relays, wiring kit, thermostat switches knobs, etc., and keeping the Refrigerator unit in satisfactory working condition all as specified and as directed by Engineer-in-Charge. Make of Refrigerator / deep freeze - LG / Godrej / Kelvinator. Note :- 1. Replacement of defective spares will be measured & paid separately as Supply and fixing
Supply and fixing following defective spare parts of Refrigerator/Deep freezer 165 to 310 ltrs cap :-
(a) Supply and fixing Thermostat switch with Knob Make :- Indfoss or Renutrol
(b) Supply and fixing Starting relay 1/6 H.P. Open type with O.L.P. Make : KOI / Whirlpool / LG / Godrej.
(c) Supply and fixing Starting relay 1/8 H.P. open type with O.L.P. Make : KOI / Whirlpool / LG / Godrej.
(d) Supply and fixing Copper filter single capillary pencil type.
(e) Supply and fixing Interior light fittings with bulb
(f) Supply and fixing Refrigerator compartment Glasses
Supply, connecting and testing of compressor suitable for 165 to 180 ltr Refrigerator or Deep freezers equivalent capacity & testing the same with one year gurantee in working condition all as directed by Engineer-in-Charge. Make : Kirloskar/Whirlpool/Godrej. Note :- The Unit Rate quoted by the Contr shall include for replacement of filter, cleaning of condenser Nuts & bolts and making necessary connection and testing complete.
Dismantaling, Repairs / maint of RO water purifier system. Make : Renuka Model No RWT - ROS - 007 complete with replacement of the unserviceable parts on making the system serviceable as per manufactures recommendation. Note : new parts will be measured and paid separately under respective item.
(a) Supply and fixing of micro spun 20. Make Renuka code RWI 107.
(b) Supply and fixing Replacement of CTO 20. Make Renuka Code RWI 109.
(c) Supply and fixing Replacement of GAC - 20. Make Renuka Code RWI 110.
(d) Supply and fixing Replacement of membrane housing 50. Make Renuka Code RWI - 125.
(e) Supply and fixing Replacement of UV system 100. Make Renuka Code RWI 137.
(f) Supply and fixing Replacement of flow restrictor adjuster. Make Renuka Code RWI 134.
(g) Supply and fixing Replacement of micronic membrane 50. Make Renuka RWI 127.
Taking down carefully storage type electric water heater (geysers) of any capacity including labour for repair/renewal/replacement of defective parts with new parts. Desconnecting of electric and water supply connection and descaling of geysers vesswel and reassembling of geysers, and installing the same in position and making necessary mounting/electric/water supply connection and testing complete all as specified and directed by Engr-In-Charge. Note :- New parts shall be measured and paid separately as Supply and fixing
(a) Supply only heating element of capacity 2 KW geysers of any make ISI marked complete as approved by Engr-In-Charge. Make Racold/Ditz/Airex
(b) Supply and fixing heating element of capacity 1.5 KW geyser of any make ISI marked complete as approved by Engr-In-Charge. Make Racold/Ditz/Airex
(c) Supply and fixing inlet/ outlet pipe assembly with rubber gasket inbcluding nuits, bolts, washers for geysers of 50/35/25 ltrs capacity complete as approved by Engr-In-Charge.
(d) Supply and fixing inner tank vessel made out of copper sheet 22 gauge for geysers of capacity 50ltrs complete as approved by Engr-In-Charge.
(e) Description all as (d) per here in before but inner tank vessel capacity 25 litre complete.
(f) Supply and fixing indicator lamp 240 volts suitable for geyser as per site requirement complete all as specified & directed.
(g) Supply and fixing GI anchor bolts and Nuts with rowel plug for mounting the geyser.
(h) Supply and fixing glass wool suitable for geyser of capacity 50/35/25 ltrs complete all as directed and approved by Engr-In-Charge.
(i) Supply and fixing geyser assembly suitable for 25 to 50 ltr capacity ISI marked as per existing make as approved by Engr-In-Charge
(j) Supply and fixing thermostate switch for geysers of capacity 50/25 Ltr ISI marked as per existing make as approved by Engr-In-Charge
(k) Supply and fixing NRV suitable for 15mm GI pipe ISI marked as per existing as approved by Engr-In-Charge
(l) Supply and fixing safety valve suitable for electric geyser complete of make as approved by Engr-In-Charge
(m) Supply and fixing flexi PVC connection 15 mm size with PTMT nuts of length 450 mm long for geyser
M&L for tubes medium grade galvanised with all fitting and fixed of size 15 mm bore complete with walls and ceiling or laid in floors with iron spacers grouting in cement mortars, including taking out old unserviceable pipe and making good to disturbed surface with cement mortars and white washing to wall surface to matching existing surface complete all as specified and directed.
Disconnecting and taking down the ceiling fan of size 1200/1400 mm sweep carefully dismantling complete for servicing by cleaning the bearing/bush by cleaining solution and replacing the split pin and unserviceable items like bearing, bushes, rubber real, condenser, flexible cable, canopy, etc., assembling Ceiling fan and refixing in the original place connection and testing complete all well as specified and as directed Note;- Replacement of unserviceable items will be measured and paid underrespective items of sch A supply only Labour charge for replacement of unserviceable parts will be deemed in quoted rate.
(a) Supply and fixing of ball bearing for 1200/1400 mm sweep Make;- TATA / SKF/NBC
(b) Supply and fixing of gun metal bushes for 1200/1400 mm sweep ceiling fan as per sample
(c) Supply and fixing condenser 2.5 Mfd for ceiling fan Make:- Havells/Usha/Universal/Apcos
(d) Supply and fixing condenser 4 Mfd Make:- Havells/Usha/Universal/Apcos
(e) Supply and fixing rubber reel suitable for 1200/1400mmsweep ceiling fan with nuts, bolts and wahsers etc.,
(f) Supply and fixing PVC 3 core Cord Flexible copper insulated cable 24/0.2mm size Black/Grey colour Make:-Plazza/Kalinga
(g) Supply and fixing down rod 400mm long with holes for nuts & bolts suitable size dia for housing ceiling fan complete all as specified and directed.
(h) Supply and fixing hanging clamps suitable for ceiling fan with rubber, nuts and bolts complete all as specified and directed.
Disconnecting and taking down the Exhaust fan with frame and louvers from wall of size 300/380/450 mm sweep carefully dismantling complete for servicing by cleaning the bearing/bush by cleaining solution and replacing the unserviceable items like bearing, condenser, flexible cable, etc., assembling Exhaust fan and refixing in the original place connection and realacement of nuts bolts and testing complete all well as specified and as directed Note;- Replacement of unserviceable items will be measured and paid under relevant items Supply and fixing
Supply and Fixing ball bearing and Bush for Exhaust fan 300 /380/450 mm sweep Make;- TATA / SKF/NBC
Collecting the burnt ceiling fans of any make from AGE E/M store yard/ site taking out to reputed work shop dismantling removing the burnt winding, rewinding of ceiling fan with super enameled copper conduct winding wire of same gauge, insulating, varnishing, baking, including wornout bearing/bush greasing assembling and transporting the same and fixing and testing of following size at site all as specified and as directed by Engr-in-charge,
(a) 1200 mm Sweep
(b) 1400 mm Sweep
Collecting the burnt exhaust fans of any make from AGE E/M store yard/ site taking out to reputed work shop dismantling removing the burnt winding, rewinding of Exhaust fan with super enameled copper conduct winding wire of same gauge, insulating, varnishing, baking, including wornout bearing/bush greasing assembling and transporting the same and fixing and testing of following size at site all as specified and as directed by Engr-in-charge,
(a) 450mm sweep
(b) 300 to 380 mm Sweep
Repair comprehensive and preventive maintenance of DG set any make of the following capacities which include taking down diesel filter, mobile oil filter, lubricating oil, rubber hose pipe, V belt, oil pipe, diesel pipe, burnt parts etc. and tightening of nuts bolts, washers greasing etc for proper running of DG set of capacity 35 KVA
Ditto all as per item No 102 above but capacity of DG Set 63 KVA.
Note for ser No 102 to 103 (i) Supply only spares part shall be measured and paid for separately and the cost of fixing charges shall be deemed to be included in the quoted rates. (ii) Cost of oiling greasing, tightening of nuts, bolts and minor work extra are included in the unit rate quoted by the contractor. (iii) Maint of diesel generating sets will be carried out and maint record shall be prepared by Contractor and signed by JE E/M, Engineer-in-Charge and Contractor. All maint register will be provided by the Contractor for record purpose. (vi) The taken down spares shall be cleaned and refitted on DG sets if found serviceiable. All other taken down parts/spares shall be replaced and paid for under relevant item of this schedule.
Removal of radiator from engine of any capacity de-scaling and brazing as required for repair of water tank etc. and re-fixing the same properly of capacity 35 KVA to 63 KVA
Material and Labour for replacement of coupling joint to engine and generator /alternatorby by taking out old coupling from the capacity of DG sets :- DG Set 35 KVA to 63 KVA
Supply and fixing asbestos rope any dia wrapped over the exhaust pipe complete.including taking down
Repair and overhauling of self starter 12 V/ 24 V of any DG set any capacity.
Rewinding of Armature for self starter of capacity 63 to 35 KVA, 12 Volt complete all specified and directed. .including taking down
Taking out FIP from DG set transportation to authorised service centre for overhauling and re-calibration and re-fixing of DG set including replacement of necessary spare parts such as delivery valves, plungers ‘O’ ring spring,nozzel etc. of capacities DG Set 35 KVA to 63 KVA
Supply and fixing in replacement of battery terminal bolt type suitable for battery 12 volt (150/180Ah) as directed by Engineer-in-Charge.
Supply and fixing battery lead of copper conductor 50 Sqmm single core PVC insulated fitted with lead terminal on one side and other side with brass or lead terminal 1 mtr long as per site required and connection as directed by Engineer-in-Charge.
Supply and fixing AVR (Automatic Voltage Regulator) for DG Set of capacity upto 35 KVA to 63 KVA
Material and Labour for replacement of turbo charger suitable for 63 KVA capacity.
Supply and replacement of coolant for radiator of any make any type of DG set at various locations.
Material and Labour for servicing and overhauling and repairing complete alternator greasing cleaning of all stator and rotor, re-varnishing the stator and rotor winding with superior quality of varnish including heating and baking the same. Re-assembling the complete alternator, fixing in position and testing on load for 35 KVA to 63 KVA DG Set capacity .
S&F in Replacement of V Belt/Grooved of approved Make for the DG Sets make – DUNLOP, MRF, JK: of capacity DG Set 63 KVA to 35 KVA
S&F in Replacement of Oil pipe complete set of approved Make for the of DG Setsof capacity DG Set 35 KVA to 63 KVA
S&F in Replacement of Oil filter of any size Make- Mico or equivalent. For capacity of DG Set 35 KVA to 63 KVA.
S&F in Replacement of Diesel filter Make- Mico or equivalent.for capcity of DG Set 35 KVA to 63 KVA.
S&F in Replacement of Water pump assembly for DG Set complete for capacity of DG Set 63 KVA
S&F in Replacement of Ignition switch of 12/24 Volts.
S&F in Replacement of Togger switch of suitable size.
S&F in Replacement of Push Button Starter of 12/24 Volts.
S&F in Replacement of CT 50/5 to 500/5 Make AE
S&F in Replacement of Oil pressure Gauge Make- Yankey or equivalent.
S&F in Replacement of Temperature pressure Gauge Make- Yankey or equivalent.
S&F in Replacement of Solenoid switch 12/24 Volts with relay of suitable capacity. Make- Cumins or equivalent.
Material and labour for replacement of battery 12 volts 180AH maintenance free lead acid including testing complete .make EXIDE, TATA,Amron
Material and labour for painting of DG Set,canopy and control panel with synthetic enemel paint two coats by spray painting approved colour after scraping of old paint, cleaning of all rusted portion, surface including sign writing i.e MES No, Make, Capacity etc complete all as directed by Engineer-in-Charge for capacity of DG Set 63 KVA to 35 KVA
Supply and Fixing of Full over hauling packing kit suitable for capacity of DG Set 63 KVA to 35KVA
Supply and Fixing of Engine sump packing suitable for capacity of DG Set 63 to 35 KVA
Material and labour for dismantling, opening of diesel engine cylinder head, removal of unservieable worn out spare parts, cleaning of all components, reboring of cylinder on lathe machine, after reboring honning process will be carrred out.replacement of all spare parts and gaskets as per manufacturer spare part kit, re-assembling of coplete engine setting, timing setting for the capacity of 35 KVA to 63 Kva DG set. Note: Spare parts will be measured and paid seperately.
Supply and Fixing of Piston ring set suitable for following capacity of 35 Kva to 63 Kva DG Set per head piston
Supply and Fixing Cylinder liner ‘O’ ring kit suitable for capacity of 35 Kva to 63 Kva DG Set as per make of DG set
Supply and Fixing Main bearing set suitable for capacity of 35 Kva to 63 Kva DG Set as per make of DG set
Supply and Fixing Oil pump set suitable for capacity of 35 Kva to 63 Kva DG Setas per make of DG set
Supply and Fixing Valve suitable for following capacity(inlet and outlet valve) suitable for capacity of 35 Kva to 63 Kva DG Set as per make of DG set
Supply and Fixing Head gasket suitable for capacity of 35 Kva to 63 Kva DG Set
M&L for Earthing complete with galvanised steel earth plate electrode 600mm x 600mm x 6 mm thick buried directly in ground (earth pit not less than 3.75 M deep below normal ground level) with top edge of the plate not less than 3.15 M below normal ground level, connected to galvanized earth strip 32mmx6mm by means of bolts, nuts, check nuts and washers of galvanised iron including necessary excavation and earth work ,PCC pit chamber in PCC (1:3:6) type C-1 using 20 mm graded aggregate with 50 mm thick pre-cast RCC cover in (1:2:4) type B-1 using 20 mm graded stone aggregate, reinforced with 8 mm dia bar@75mm c/c both way with two Nos lifting handles of 12 mm dia mild steel plain bar, funnel with wire mesh, lugs, 50mm dia galvanised iron protection pipe light grade ,watering pipe of size 20 mm dia galvanised iron light grade, main Earthing strip upto 7.5M including charcoal dust, common salt etc all as shown in electrical plate No. 3 of SSR Part-I 2009 including testing on completion complete all as specifed and as directed. Including Taking Down old Unsv Earthing.
Supply, Installation, Testing and Commisioning incl Taking down old unsv Power Command Controller of model no DGC 60/ or as per existing make on ground of Power Command Controller Microprocessor/Microcontroller based Model No DGC-6D of DG Set AMF of capacity 35 KVA ,Housed in , Flush mounted enclosure,Discrete Logic based AMF, 3 Phase Under and over voltage protection of generator supply, Generator overspeed supervision, DC Battery Voltage supervision, External fault Detection,DG Fail to Start supervision and indication,stop Supervision and indication, Units remain fully operational (even if battery voltage falls to zero for one sec) , DGC-6D equipped with backlit LCD which display ( EB Voltagesof RYB Phase, Generator Voltage, Generator Current, Generator Frequency, RPM,Cumulative Run Hour five digit, Set Values, LED Indications, Load on Generator GCB, Auto/Manual Mode, Emergency Fault/Low Fuel fault) Operated on 12/24 Volts. Complete all as specified and directed.incl Taking down old unsv one.
Supply and top up engine oil all as specified and directed by engineer in charge Make- Kirloskar K.Oil/ Indian Oil/ Castor Oil or Equivalent.Including taking down old unsv one.
Material and labour for fixing or passing through pipe, laid in trenches or fixed to pole/wal or fixed to LT panel board, 1100 volts grade heavy duty cable with PVC insulated stranded aluminium conductor served with inner sheathing of PVC tape, armoured with galvanised steel wire or tape and overall PVC sheathed 70 Sqmm 3.5 core with required aluminium cable lugs all as specified and directed. Make of Cable : Havells, Polycab, Gloster,Finolex
Supply, installation, commissioning and testing in replacement of old unserviceable outdoor type LT panel(CPRI Approved) made out of 3.15 mm thick sheet metal, double door made out of MS angle iron base frame, cubical type floor mounted 3 Phase, 4 Wire, 415 Volts properly insulated aluminium bus bar - 04 Nos having capacity 400 amps on phase & neutral, dust and vermin proof, both side open with locking arrangement comprising of comprising of Digital meters with 3 lines of voltage, current and frequency and power factor of size 96x96 sqmm, suitable ratio CT, phase indicator-03 Sets, danger board plate, duly painted internally and externally with powder coated, fixing in position by provision of platform suitable size built with brick work in CM (1:4), 15 mm thick plastering in CM (1:6) and mounted on angle iron frame of ISA 75x75x6mm including glands, lugs, thimbles for all incomming and out going cable complete all as directed by the Engineer-in-Charge of suitable sizes for following :- Loc- Jhajjar nallah
(a) INCOMING
(i) MCCB 160 Amps adjustable type, 4 Pole, 415 V, 25 KA - 01 No
(ii) Digital volt meter - 01 Nos
(iii) Digital ammeter - 01 Nos
(vi) Current Transformer (CT) (Set of Three) - 1 Nos
(vii) Phase indicator lamp (RYB) set of three - 01 No
(b) OUTGOING
(i) MCCB 63 Amps adjustable type, 4 Pole, 415 V, 25 KA - 02 No
(ii) Single Phase Preventer for capacity upto 10 HP Motor- 02 Nos
(iii) Digital volt meter - 02 Nos
(iv) Digital ammeter - 02 Nos
(vi) Current Transformer (CT) (Set of Three) - 2 Nos
(vii) Automatic Star Delta Starter- 10 HP-02 Nos
Supply, installation, commissioning and testing in replacement of old unserviceable outdoor type LT panel(CPRI Approved) made out of 3.15 mm thick sheet metal, double door made out of MS angle iron base frame, cubical type floor mounted 3 Phase, 4 Wire, 415 Volts properly insulated aluminium bus bar - 04 Nos having capacity 400 amps on phase & neutral, dust and vermin proof, both side open with locking arrangement comprising of comprising of Digital meters with 3 lines of voltage, current and frequency and power factor of size 96x96 sqmm, suitable ratio CT, phase indicator-03 Sets, danger board plate, duly painted internally and externally with powder coated, fixing in position by provision of platform suitable size built with brick work in CM (1:4), 15 mm thick plastering in CM (1:6) and mounted on angle iron frame of ISA 75x75x6mm including glands, lugs, thimbles for all incomming and out going cable complete all as directed by the Engineer-in-Charge of suitable sizes for following :-
(a) INCOMING
(i) MCCB 250 Amps adjustable type, 4 Pole, 415 V, 25 KA - 01 No
(ii) Digital volt meter - 01 Nos
(iii) Digital ammeter - 01 Nos
(vi) Current Transformer (CT) (Set of Three) - 1 Nos
(vii) Phase indicator lamp (RYB) set of three - 01 No
(b) OUTGOING
(i) MCCB 200 Amps adjustable type, 4 Pole, 415 V, 25 KA - 02 No
(ii) MCCB 100 Amps adjustable type, 4 Pole, 415 V, 25 KA - 02 No
(iii) Digital volt meter - 02 Nos
(iv) Digital ammeter - 02 Nos
(vi) Current Transformer (CT) (Set of Three) - 2 Nos
(vii) MCCB 63 Amps adjustable type, 4 Pole, 415 V, 25 KA - 01 No
Demolition of cement concrete (unreinforced) in ground floor and in paving not exceeding 15 cm thickness (below or above ground level) complete, all as specified.
Demolition of brick work or stone/boulder masonry, built in cement mortar including all quoins arches, pillar etc but excluding ashlar facing, dressed stone work and precast concrete articles, complete all as specified and directed .
Material and labour for brick work with old size sub class 'B' burnt clay bricks, straight or curved on plan exc. 6m mean radius, built in cement mortar 1:4 complete all as specified and as directed.
M&L for Brick work with sub class 'B' bricks (except bricks), straight or curved on plan exceeding 6 metre mean radius in cement mortar 1:4, complete all as specified and directed.
Material and labour for cement concrete 1:4:8 type D-2 (using 40mm graded crushed stone aggregate) as in foundation filling and mass concrete, complete all as specified and as directed.
M&L for Stone walling of random rubble, uncoursed, well bonded, bedded and solidly hearted, built with CM 1:4 complete all as specified and directed.
M&L Stone walling (except stone) of random rubble, uncoursed, well bonded, bedded and solidly hearted, built with CM 1:4 complete all as specified and directed
M&L for extra over stone walling for hammer dressing to face hammer dressing to face stones and dressing of face beds and joints, as specified, of random rubble walling, uncoursed or brought upto courses with granite or trap stone for 20 mm complete all as specified and directed.
M&L for racking out joints/ pointing to masonry or brick work in single detached joints for flashing etc complete all as specified and directed
M & L raised pointing in cement mortar 1: 4 to random of polygonal rubble, uncoursed or brought upto courses complete all as specified and directed
M & L providing pre- cast cement conrete type C-1 1:3:6 (20 mm graded stone aggregate) as bonders in stone walling and set in CM 1:6 complete all as specified and directed
Material and labour for Plain Cement concrete 1:2:4 type B-1 (using 20mm graded crushed stone aggregate) as in coping, benching including weathering slightly rounded or chamfered angles as directed including necessary form work complete all as specified and as directed.
Taking down cement plaster, any description on brick or stone or cement concrete walls including raking out joints, hacking for key, scrubbing down with water complete all as specified and directed.
M/L 15mm thick rendering in cement mortar 1:4 in two layers using WPC as per manufacturer instruction on finishing layerof rendering on brick or concrete surfaces finished even and smooth complete all as specified.(Note: WPC shall be measured and paid separately under appropriate item as supply only)
Supply only integral water proofing compond approved brandcomplete all as specified.
Material and labour for Plain Cement concrete 1:3:6 type C2 (using 40mm graded crushed stone aggregate) as in surface channels and drains complete all as specified and as directed.
M& L for extra for forming fair finished drain or channel 30cm inner girth in cement concrete using extra cement incl forms, moulds, mitred.
M& L for Add or deduct for each 25 mm girth or part there of over or under 30cm inner girth in cement concrete using extra cement incl forms, moulds, mitred complete all as specified and directed.
75mm thick PCC 1:3:6, type C-2 using 40mm graded stone aggregates as in sub base of floor, finished even and fair, complete all as specified and directed.
25mm thick sand cushioning for laying of paver blocks complete all as specified and directed. Note :- Punned thickness of sand shall be measured and paid.
M&L for Factory made, Machine pressed precast concrete interlocking paver block any shape and size approved by EIC, ISI marked (IS:15658-2006) of 60 mm thick, M-35 grade (medium Traffic), with grey cement & pigment, complete all as specified and directed.
M&L Machine pressed gloosy finish cement concrete chequered tiles of size 300x300x25mm, jointed and pointed with mixture of white & grey cement in equal prapotion and pigment to match the colour of tiles complete all as specified and directed.
M & L screed bed or bedding layer of mortar 20mm thick in CM 1:6 for laying floor finishes complete all as specified and directed.
Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified and directed.
S&F Mild steel rolled section as in grating framed, trussed, purlins, crane gantries, rails and fastening and heavy bracket framing (Beam, tee, angle, channel or flat sections) incl distance pieces, cleats etc. confirming to grade Fe-290. Gde- E-165. complete all as specifed and directed.
S&F, Mild steel framed work such as grills, gratings, etc. with ends of bars shouldered and/or riveted or forged into spikes, framed guard bar; barred iron doors; ladder; framed balusters; railing;frame work for water tanks and similar work conforming to Fe 290 Gde-E-165 complete all as specified.
M & L for cement concrete type B-2 1:2:4 (20 mm graded aggregate) in walls or retaining walls, any thickness, size or shape including pilasters, buttresses columns, pillars, boundary pillars and posts (including caps and bases). complete all as specified and directed.
M & L for preparation of new steel surfaces of any description, over 10 cm width or girth, not other wise described and applying two coat of synthetic enamel paint over a priming coat of red oxide zinc chrome primer complete all as specified and directed.
MandeepConstructionCo
M/SHansrajbuilder
M/S PAWAN KUMAR ANAND
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .