Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹28.4 LAccepted-AOC | L1 | Accepted-AOC Accepted | |
| 2 | L2₹35.8 L+₹6.5 L (22.1%)Rejected-Finance | L2 | Rejected-Finance Not Lowest | |
| 3 | L3₹39.9 L+₹10.7 L (36.4%)Rejected-Finance 38 BUDDHADEV BASU ROAD ASHRAMPARA POST SILIGURI DIST DARJEELING | L3 | Rejected-Finance Not Lowest | |
| 4 | L4₹40.5 L+₹11.3 L (38.5%)Rejected-Finance | L4 | Rejected-Finance Not Lowest | |
| 5 | L5₹40.7 L+₹11.4 L (39.1%)Rejected-Finance RATNA RAJ BUILDING 1ST FLOOR 262 BIDHAN ROAD OPP TERA HOTEL PO SILIGURI 734001 DIST DARJEELING WB | JALPAIGURI | WEST BENGAL | 734001 | L5 | Rejected-Finance Not Lowest |
Tender Value
₹43.5 L
EMD Value
₹87,000
Closing Date
17 Dec 2024, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE SEVOKE ROAD
GE Sevoke Road Post Salugara Dist Jalpaiguri PIN 734008
REPAIR, MAINTENANCE AND REPLACEMENT OF CABLES, POST TOP LAMPS, FLOOD LIGHTS, SECURITY LIGHTS AND CONNECTED ITEMS AT SEVOKE ROAD MIL STN UNDER GE SEVOKE ROAD
2024_MES_684598_1
8403/SEV OF 2024-25
Open Tender
Civil Works
Item Rate
180 days
GE SEVOKE ROAD
AS PER TENDER DOCUMENTS
7 documents required · 7 mandatory
₹0
₹87,000
24 Jan 2025
20 Nov 2024
20 Dec 2024
20 Nov 2024
17 Dec 2024
4 Dec 2024
21 Nov 2024 - 30 Nov 2024
Amount
Excavation in trenches not exc 1.5 Mtr wide and not exc 1.5 Mtr deep soft/loose type of soil getting out and levelling of bottom surface to required level for cable/stay all as directed.
Removing excavated soil to a distance not exc 50m and depositing where directed at a level not exc 1.5m above the starting point all as specified and as directed.
Returning,filling in,including spreading,levelling, watering and well ramming in layers not exceeding 25 cm thick all as specified and as directed.
Materials and labour for 50 mm outer dia double wall corrugated (DWC) HDPE pipe, ISI marked for enclosing cable below ground/road surface to a required depth including suitable size couplers for jointing of pipe all as per site requirement etc complete all as specified and directed.
Materials and labour for 75 mm outer dia double wall corrugated (DWC) HDPE pipe, ISI marked for enclosing cable below ground/road surface to a required depth including suitable size couplers for jointing of pipe all as per site requirement etc complete all as specified and directed.
Materials and labour for GI tubing of 40 mm bore light grade with all fitting fixed to wall/ceiling/pole or in trench formed by road/PCC cutting/boring as cable protection laid on floor all as specifed and directed.
Materials and labour for GI tubing of 50 mm bore light grade with all fitting fixed to wall/ceiling/pole or in trench formed by road/PCC cutting/boring as cable protection laid on floor all as specifed and directed.
Supply and fixing for GI tubing of 80 mm bore light grade with all fitting fixed to wall/ceiling/pole or in trench formed by road/PCC cutting/boring as cable protection laid on floor all as specifed and directed.
Supply and laying in trenches/wall LT UG XLPE insulated ,armoured heavy duty electric cable with aluminium conductor 1100 volts grade cross sectional area 120sq mm x 3.5 core including taking down old u/s making necessery connections all as specified and as directed.
All as per item No 9 above but 50sqmm, 3.5 core
All as per item No 9 above but 25sqmm, 4 core
All as per item No 9 above but 16sqmm, 4 core
All as per item No 9 above but 16sqmm, 2 core
All as per item No 9 above but 10sqmm, 4 core
All as per item No 9 above but 10sqmm, 2 core
Materials and labour for replacement of Steel tubular swaged pole complete with cast iron base plate, finial taper plug, bolts, nuts and screws of type 410 SP-31 ( 9 metre long) complete all as specified and directed.
Materials and labour for replacement of steel tubular swaged poles with swan neck arrangement for fixing street light fittings complete with cast iron base plate, finial taper plug, bolts, nuts and screws of type 410 SP-75 ( 14.5 metre long) complete all as specified and directed.
Materials and labour for PCC, type C1, 1:3:6, (using 20mm graded crushed stone aggregated) as in coping of poles including formwork including demolition of old damaged concrete from pole complete all as specified and as directed
Materials and labour PCC, type D2, 1:4:8, (using 40mm graded crushed stone aggregated) as in PCC/Road cutting /installation area and foundation of pole etc complete all as specified and as directed.
Materials and labour for boring horizontal holes 100mm dia upto 2mtr deep in soil under roads /PCC as directed for cable passing through pipes of required size and disposal of soil to a distance not exc. 50m (Note: connected items like pipes is measured and paid separately under relevant items)
Supply and fixing in repair Indicator lamp (AC/DC), LED, type for as per existing fitting.complete all as specified and as directed by Engr-in-Charge.
Supply and fixing in repair 3 Phase LED Ammeter complete all as specified and as directed by Engr-in-Charge.
Supply and fixing in repair, 3 phase LED Voltmeter complete all as specified and as directed by Engr-in-Charge.
Supply and fixing cable jointing kit for 1.1 KV grade for straight through joint complete with jointing material heat shrink type and accessories suitable for 3.5/4 core XLPE, armoured, aluminium conductor cable of size 16 to 50 Sqmm, Outdoor type, including taking out & relaying damaged UG cable after repair complete all as specified and as directed. (Note:- Excavation and connected items will be measured and paid separately)
Supply and fixing cable jointing kit for 1.1 KV grade for straight through joint complete with jointing material heat shrink type and accessories suitable for 3.5 core XLPE, armoured, aluminium conductor cable of size 70 to 185 Sqmm, Outdoor type, including taking out & relaying damaged UG cable after repair complete all as specified and as directed. (Note:- Excavation and connected items will be measured and paid separately)
Supply and fixing as in repairs MCCB four pole , 415 Volt, 63 Amps,16 KA , fixed thermal & magnetic setting complete all as specified and directed
Supply and fixing as in repairs MCCB four pole , 415 Volt, 100 Amps, 25 KA , fixed thermal & magnetic setting complete all as specified and directed .
Supply and fixing as in repairs MCCB four pole , 415 Volt, 125 Amps,25 KA , fixed thermal & magnetic setting complete all as specified and directed.
Supply and fixing MCCB, 160 Amps, 4P, 25 kA, 415 Volts, with adjstable thermal release & adjustable magnetic release complete including taking down old unserviceable MCCB complete all as specified and as directed. .
Materials and labour for earthing complete with galvanized steel pipe electrode 40mm bore, medium grade, 3.5 meters length, buried directly and preferably vertically in ground with top edge not less than 1.25 meters below ground level connected with earthing lead galvanized iron strip of size 25x4 mm connected to galvanized earth pipe by means of bolts, nuts, checknuts and washer of galvanized iron including PCC (1:2:4) type B1 precast RCC cover slab with suitable handle made of 6mm round bar, including necessary excavation and earth work in any type of soil, 20mm dia medium grade galvanized steel tube for watering with one end fix with cast iron funnel and wire-mesh, with protection pipe of 32 mm dia light grade galvanized steel tubing upto 7.5 meters length for drawing earthlead including common salt, charcol , bentonite in alternate layers etc all in around of earthing pipe of 600mm dia, complete all as shown in EP number 2 of SSR Part-1 including testing on completion and including taking down old U/S earthing & testing complete all as specified and as directed.
Materials and labour for painting old painted LT Panel/feeder pillar by two coats of synthetic enamel paint after preparation of surfaces complete all as specified and as directed.
Servicing of LT Panel after shut down and removing all dust particles and proper layout of LT panel wlth gland packing including 2.5 sqmm copper single core copper cable including repairing/replacing door hinges/door lock etc for necessary connections complete all as specified and directed
Materials and labour for Preparation of metalic surface with sand paper for street light pole and other steel surface complete all as specified and as directed by Engr- in-Charge
Materials and labour for one coat of red oxide zinc chrome primer on steel surfaces of street light pole and other steel surface complete all as specified and as directed by Engr- in-Charge
Materials and labour for aluminium paint two coats on newly primed metalic surface of street light pole and other steel surface complete all as specified and as directed by Engr- in-Charge
Materials and labour for two coats of Yellow/black synthetic enamel paint on metalic surface complete all as specified and as directed by Engr- in-Charge
Materials and labour for preparation of old decorated concrete/plastered surfaces and applying two coats of Cement based paint complete all as specified and as directed by Engr- in-Charge
Labour only for taking down any unserviseable street light fittings/flood light/garden light/gate light/fountain light fitting any type/size and refixing same after repair/replacement of all unserviceable accessories of any type and size from existing position/location or removing connection oxide by cleaning terminals and shifting materials to store for keeping in safe custody for repair work or taking credit complete all as specified and as directed. (Note: Items if required for repair work will be measured and paid seperately under relevant items)
Supply and fixing in repair LED 25 W warm white colour building security light made up of pressure die cast housing with high efficient LED as lighting source and toughned glass cover having top opening separate driver compartment with IP66 protection and impact resistance of IK07 and suitable for dia 40 mm complete all as specified and directed.
Supply and fixing in repair LED street light of capacity 70 Watt made up of pressure die cast aluminium housing with high power LED as light source and lens embedded toughned glass including electronic driver should have luminaire efficacy ≥140 lumens/watt, CRI>70, PF > 0.95, CCT=5700±300, IP66,impact resistance IK 07, inbuilt protection against lightning, over voltage, short circuit and surge/spike protection upto 10KV including suitable fixing arrangement with 40mm dia existing braket and connection suitable for 40mm dia braket with PVC insulaed PVC sheathed, multistranded copper conductor cable of size 1.5 sqmm x 3 core from light fitting to pole box complete all as specified and directed.
Supply only LED Garden spike light 12 W RGB, with dust jet water protection including taking down old u/s and making necessery connections complete all as specified and directed.
Supply and fixing LED light water proof light having IP-68 under water Led light 10 watt compatible for fountains white/warm white colour including taking down old u/s and making necessary connections complete all as specified and directed.
Supply and fixing in repair LED warm white bollard light 9W LED bollard with opal acrylic diffuser having arrangements for replacing the LED bulbs and IP66 protection suitable for dia upto 60mm complete all as specified and directed.
Supply and fixing in repair warm white LED 20 W post top made in cast aluminium with decorative opal polycarbonate diffuser with IP 65 protection suitable for dia upto 60mm complete all as specified and directed.
Supply and fixing in repair warm white LED 40 W post top made in cast aluminium with decorative opal polycarbonate diffuser with IP 65 protection suitable for dia upto 60mm complete all as specified and directed.
Materials and labour for water proof, 3 core PVC insulated and PVC sheathed, copper conductor cable of size 1.5 sqmm, 1100 Volts grade including PVC conduits properly fixed on steel/RCC poles using GI wire for electrical connection of street light fittings, complete all as specified and directed.
Materials and labour for water proof, 3 core PVC insulated and PVC sheathed, copper conductor cable of size 2.5 sqmm, 1100 Volts grade including PVC conduits properly fixed on steel/RCC poles using GI wirefor electrical connection of street light fittings, complete all as specified and directed.
Supply and fixing cable junction box having protection "dust proof, acid resistant, shock proof, fire retardent self extinguisher" for outside installation with knockout entry for cable of size upto 25 sqmm and of size 295X195x100mm with terminals, brackets for street light pole mounting and including one 6A MCB SP all as specified and as directed.
Supply and fixing cable junction box having protection "dust proof, acid resistant, shock proof, fire retardent self extinguisher" for outside installation with knockout entry for cable of size upto 25 sqmm and of size 155x155x100mm with terminals, brackets for street light pole mounting and provision of one 6A MCB SP all as specified and as directed.
Materials &Labour for submain wiring with two single core PVC insulated, unsheathed, FRLS, stranded copper conductor of size 1.5 Sqmm and one single core PVC insulated, unsheathed,FRLS, stranded copper conductor 1.5 Sqmm green in colour as earth continuity conductor drawn into and including PVC casing capping (medium grade) of suitable size with all fitting & accessories complete including taking down old unserviceable sub-main wiring all as specified and directed by Eng-in-Charge . (Note: Two runs of 1.5 Sqmm cable and one run of 1.5 Sqmm earthing cable along with casing capping altogether shall be measured as one unit.)
Supply and fixing in repair switch piano flush type single pole one way 5 Amps
Supply and fixing in repair PVC rectangular block for mounting, switches, sockets, fan regulator etc. with 3 mm thick plastic laminated sheet cover of size 100 mm x 100 mm and 50 mm deep for mounting switches.
Supply and fixing in repair ceiling rose surface bakelite 50x25 mm three terminal complete all as specified and as directed
Taking down existing unsv/faulty LT UG cable 1100V of any size from existing location and relaying the same after necessary repair work all as specified and directed. (Note: Items if required for repair and excavation works will be measured and paid separately under relevant items)
Relaying of old recovered cable cover of any size in trenches all as directed.
Taking out old servicable tilted poles and refixing same at location as directed by engineer-in-charge including excavtion for taking out complete all as directed. Note:- PCC for foundation and coping work shall be measured and paid separately under respective items.
Materials and labour for repairing of junction boxes by replacing all cable terminals followed by dressing of cable heads and refixing with two aluminium strips with nut bolts all as directed.
Taking out old bricks and relaying after cable repair work complete all as specified and as directed.
Materials and labour bracket for street light made out of 40mm dia medium grade GI Pipe of 1.5 mtr length, bend to shape with 02x clamps of existing size and shape and 04 Nut bolts inclusive of 2 coats of aluminium paint over a coat of primer after preparation of surface including taking out old unservicable bracket complete all as specified and as directed.
Materials and labour for GI bracket made out of 25 mm bore medium grade GI Pipe with two sets clamps grouted in wall with four number of wall fastners , bend to shape all as directed, length of pipe shall not be less than 1.5 metre for fixing of light fittings inclusive of 2 coats of aluminium paint over a coat of primer after preparation of surface including taking out old unservicable bracket complete all as specified and as directed.
Supply only MS adopter for street light fitting of existing size and shape with nut bolts inclusive of one primer coat , one finished coat of aluminium paint all as specified and as directed.
Supply and fixing 20 mm dia PVC conduit on the Steel/RCC poles, fixed by using GI clamp of suitable size including nuts and bolts by disconnecting existing open/loose 1.5 Sqmm single/three core pvc wire and inserting same in PVC conduit complete all as speciifed and as directed.
Supply and fixing in repair LED flood light warm white colour 100 watt 230 V AC outdoor type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant complete with driver and lamp all as specified and as directed.
Supply and fixing in repair LED flood light warm white colour 120 watt 230 V AC outdoor type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant complete with driver and lamp all as specified and as directed.
Materials and labour for grouting of 40 mm dia medium grade GI pipe (including cost of GI Pipe) using PCC type C1 for fixing post top lamps on MES installtions pump houses/sub station etc minimum 15 cm pipe shall be inside the pillar/post and 40 cm above the post/pillar complete all as specifed and as directed by engr in charge.
Supply and fixing in repair 8 KW ,three phase automatic Street Light timer switch for automatic switching on/off street light based on lux level of nature light, consisting of sensor overload protection fuse gear, power contactor & MCB of suitable capacity, terminal blocks for cable entry & control unit enclosed in pole/Wall mountable elcosure made out of rust proof, shock proof, termite proof FR grade SMC, conforming to IP 66 with universal lock and key arrangement complete all as specified and as directed by Engr- in- Charge Make: kakatiya energy system Pvt Ltd Cat No. Swadeep 66-02EC-5KW 3P or equivalent in Havells/GE
Servicing of LT Panel including fixing of damaged doors, disconnecting of all LT cable and refixing including, painting of entire panel with two coats of syntheic enamel paint and replacement of lugs complete all as specified and directed.
Supply and fixing in repair LED lights driver of existing make for bollard light/post top lamp/building security light upto 40 watt complete all as specified and as directed.
Supply and fixing in repair LED lights driver of existing make for bollard light/post top lamp/building security light upto 120 watt complete all as specified and as directed.
Materials and labour for taking out old unservicable flood light from high mast poles upto 16M height and refixing same after repairing complete all as specified and as directed. The quotated rates shall be inclusive of all safety arrangements and cost of making scaffolding /hiring of cranes for taling down flood lights upto 16M height.
Materials and labour for servicing of cable junction box by taking out old serviceable cable and refixing same after dressing the cable and inserting suitable size lugs complete all as specified and as directed.
CHANDAN TRADERS (BID ID -3185009)
M/S BUILDERS ENTERPRISE (BID ID -3185896)
SHRI JIBANDHAN PAUL (BID ID -3184857)
ENGINEERING AND CONSTRUCTION CO. (BID ID -3182763)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .