Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹37.6 LAccepted-AOC B 150 GROUND FLOOR BACK SIDE PANDAV NAGAR DELHI 110092 | DELHI | EAST DELHI | DELHI | 110092 | 1 | Accepted-AOC QUOTED RATES ARE REASONABLE AND ACCEPTED | |
| 2 | 2₹40.1 L+₹2.5 L (6.54%)Rejected-Finance | 2 | Rejected-Finance OTHER THAN LOWEST | |
| 3 | 3₹40.1 L+₹2.5 L (6.71%)Rejected-Finance VILL MOHANPUR PO SEWLI TELINI PARA PS TITAGARH DIST 24 PGS NORTH KOLKATA 700121 | 24 PARAGANAS NORTH | WEST BENGAL | 700121 | 3 | Rejected-Finance OTHER THAN LOWEST | |
| 4 | 4₹40.3 L+₹2.7 L (7.26%)Rejected-Finance REGD OFFICE VILLAGE KHEJURI TEHSIL SIKANDARPUR DISTT BALLIA UTTAR PRADESH | BALLIA | UTTAR PRADESH | 277303 | 4 | Rejected-Finance OTHER THAN LOWEST | |
| 5 | Rejected-Technical STATION ROAD POST RANGIYA DIST KAMRUP ASSAM PIN 781354 | KAMRUP | ASSAM | 781354 | - | Rejected-Technical FIRM BANNED IN WLR QE JUN 2023 |
Tender Value
₹44 L
EMD Value
₹88,000
Closing Date
21 Nov 2023, 6:00 pmClosed
GE AF BIHTA
Aif Force Station Bihta - 801103
WIDENING OF PCC ROAD IN SMQ AREA AND CERTAIN OTHER MINOR AND REVENUE WORKS AT AF STN DARBHANGA
2023_MES_625048_1
8356/BHT/DBG/E8
Open Tender
Civil Works
Item Rate
180 days
Darbhanga
Class D category a(i)
7 documents required · 7 mandatory
₹500
GE (AF) Bihta
₹88,000
Yes
24 Jan 2024
26 Oct 2023
29 Nov 2023
26 Oct 2023
21 Nov 2023
9 Nov 2023
27 Oct 2023 - 2 Nov 2023
Amount
S&F adjustable metal curtain rod, 1 inch rod diameter, capable of hanging heavier fabrics which can hold upto 10 Kg load, rod length from 36 to 72 inches with decorative finials and mounting brackets incl required screws on either end, complete all as specified and directed by Engr-in-Charge.
Surface excavation n exc 30cm deep and averaging 15cm and getting out in Soft/ loose soil, complete all as specified and directed.
Excavation in trenches not exc 1.5 m wide and not exc 1.5 m deep for foundation etc or for shafts, column footings or for laying cables etc not exc 10 Sqm on plan and getting out in soft/loose soil, complete all as specified and directed.
M&L PCC 1:4:8 type D-2, using 40 mm graded stone aggregate, as in foundation, filling, mass concreting etc, complete all as specified and directed.
M&L brick work with pulverized fuel Ash-lime bricks (Fly ash bricks - non modular size), straight or curved on plan exc 6 m mean radius, built in CM 1:6, complete all as specified and directed.
M&L for mild steel TMT bars, 10 mm dia and over, cut to length, bent to shape required including cranking, bending spirally for hooping for column, hooking ends and binding with and incl MS wire (annealed) not less than 0.9 mm dia complete all as specified and directed.
M&L for mild steel TMT bars, 6 to 8 mm dia, cut to length, bent to shape required including cranking, bending spirally for hooping for column, hooking ends and binding with and incl MS wire (annealed) not less than 0.9 mm dia complete all as specified and directed.
~Ditto~ but 5 to 10 mm dia mild steel TMT bars as in stirrups, spacers and binders etc complete all as specified and directed.
M&L RCC 1:2:4 type B-1 using 20 mm graded stone aggregate, as in foundations, including rafts, footings, foundation beams, plinth beams, bases for columns etc, under-reamed piles and mass concrete, complete all as specified and directed.
M&L RCC 1:2:4 type B-1 using 20 mm graded crushed stone aggregate, as in columns, pillars, piers, posts and struts etc, complete all as specified and directed.
Formwork (rough finished surfaces) to sides of columns, pillars, piers, posts, struts and stanchions etc complete all as specified and directed.
M&L for 15 mm thick rendering on brick work or concrete surfaces in CM 1:4 finishing surfaces even and smooth without using extra cement complete all as specified and directed.
M&L preparing newly plastered surfaces of walls and applying two coats of cement based paint over a coat of primer, complete all as specified and directed.
Returning filling in soil including spreading, leveling, watering and well ramming in layers not exc 25 Cm, complete all as specified and directed.
Removing excavated materials (soil) not exc 50 m distance and depositing where directed at a level not exc 1.5 m above starting point, complete all as specified and directed.
M&L Mild Steel work in roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc., conforming to Fe 410-W (Gde - E-250) quality-A, complete all as specified and directed.
S&F Prepainted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified, complete all as specified and directed.
S&F Prepainted galvalume aluminum zinc coating GI based Plain steel sheet crimped eaves and steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified, complete all as specified and directed.
M&L hardcore (broken stone) of gauge not exc 63 mm, deposited spread and leveled in layers not exc 15 cm thick, watered and rammed to a true surface, complete all as specified and directed.
M & L 150 mm thick PCC 1:2:4 type B1 (using 20mm graded stone aggregates) as in base course to floor finish, complete all as specified and directed.
M & L for preparation of new or previously untreated steel surfaces exceeding 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer, complete all as specified and directed.
M&L forming construction joints 30 mm deep and 10 mm wide, filled with sealing compound grade - B, complete all as specified and directed.
M&L for 100mm thick plain cement concrete type C-2, 1:3:6 (using 40mm graded stone aggregate) as in sub floors, sub bases, floor and pavings etc complete all as specified and directed.
M&L for 40mm thick plain cement concrete type B-0, 1:2:4 (using 12.50mm graded stone aggregate) as in floors, bases and pavings etc, complete all as specified and directed.
M&L for PCC 1:2:4 type B-0 (using 12.5 mm graded crushed stone aggregate) as in cills, coping, benching on chajjas, roof kerbs, bed blocks and the like including weathering, slightly rounded or chamfered angles and throating as directed with and including necessary Formwork, complete all as specified and directed.
Formwork (fair finished surfaces) to flat faces of walls, retaining walls, abutments, parapets and staircase railings and similar work including attached pillasters, buttresses, etc.; vertical or to batter, complete all as specified and directed.
Supply only glass dividing strips 3 mm thick and 38 mm wide, fixed in position to conform to design, complete all as specified and directed. (Rate of fixing shall be deemed included in the unit rates of PCC flooring).
M&L for 15 mm thick rendering on fair faces of brick walls or concrete surfaces in CM 1:6, finishing surfaces even and smooth without using extra cement, complete all as specified and directed.
M&L for obtaining approved earth (Stablised soil) from out side of MoD land (exc. 1km and not exceeding 30km) and bringing out to site and deposited for embankment /filling of craters/other purposes, complete all as specified and directed.
Spreading and levelling soil in layers not excedding 25 Cm thick and well ramming including watering as required, complete all as specified and directed.
S&F Collapsible steel gates, top hung, consisting of channel pickets, pivoted flat bars, top and bottom runners, brass handles etc., as specified, erected in position and securing runners with holdfasts and brackets, complete which include fixing to both new or old work and shall be done with a mix of concrete not leaner than PCC 1:2:4 type B1(size 150mmx100mmx100mm) complete all as directed by E.I.C.
Taking out old serviceable glass of any description, from old wooden or metal frames, or stone, concrete or brick surrounds, any thickness or size; hacking out old putty or removing beads etc, including making good breakages in taking out and handling removing to store or stacking for reuse, complete all as specified and directed.
M&L preparation of newly plastered surfaces of walls and applying 3 mm thick wall care putty as per manufacturer's instructions and over it applying two coats of distemper oil emulsion over a coat of primer, complete all as specified and directed.
S&F rolled mild steel framed work (Fe-410 W Gde-E250) quality B as in doors or wicket gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing complete all as specifed and directed.
M&L preparing new iron surfaces of any description not exceeding 10cm in width or girth when unconnected with other painting or when painted in a different tint and applying two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer, complete all as specified and directed.
S&F Framed work such as grills, gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework and similar work conforming to Fe.290.Gde-E-165 for portion framed and hung as gates incl pintle hinges, stops, hand made sliding bolts etc complete all as specified and directed.
Cutting holes in brick walls built in cement mortar exc half brick but not exc. one brick for inserting holdfasts and making good dismantled portion in cement mortar 1:3 or cement concrete 1:2:4 Type B-1 as required, complete all as specified and directed.
S&F Anodised 8mm thick aluminium grill having diamond shape opening of 50mmx50mm (anodised transparent or dyed to required shade according to IS:1868 with minimum anodic coating of grade AC 15) of approved design/pattern, with approved standard section and fixed to the existing window frame with C.P. brass/ stainless steel screws @ 200 mm centre to centre, including cutting the grill to proper opening size for fixing and operation of handles and fixing approved anodised aluminium standard section around the opening, all complete as per requirement and direction of Engineer-in-charge. Note- It includes for anodised aluminium hardware as indicated, glazing clips, rubber packing, anodised aluminium snap on beading for fixing glass panes in frames.
Forming embankments including raising (or lowering) earth, spreading in layers n exc. 30 cm thick; watering, ramming/rolling and finishing to required size, shape, etc., n exc. 1.5 m high from base, complete all as specified and directed.
S&F 50 mm bore Galvanized Steel tubes, medium grade with all fittings and fixed complete to walls and ceilings or laid in floors complete all as specified.
Excavation over areas not exc 1.5 m deep and getting out in soft/loose soil, complete all as specified and directed.
M&L Providing cement concrete 1:2:4 type B-1 using 20 mm graded stone aggregate as in lintels upto 1.5m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, kerbs, water troughs and the like including weathering, slightly rounded or chamfered angles and throating, including use and waste of necessary form work, complete all as specified and directed.
M&L RCC 1:2:4 type B-1 using 20 mm graded stone aggregate, as in slabs supported on walls, beams, columns etc, roofs, landings, deck slabs, shelves etc complete all as specified and directed.
Formwork (rough finished surfaces) to soffits of suspended slabs such as roof slabs, floor slabs, landing and similar works, not exc 200 mm thick, complete all as specified and directed.
Formwork (rough finished surfaces) to edges of concrete exc 10 Cm thick and not exc 20 Cm thick as in slabs, bands, cills, flooring etc for rough finished surfaces complete all as specified and directed.
Earth filling under floors, laid in layers not exceeding 15 cm thick, leveled and rammed including watering, complete all as specified and directed.
Excavation in post holes (or similar holes) Each n exc 0.50 Cum, getting out, returning filling in and ramming earth or broken rubble mixed with earth around in layers not exceeding 25 cm, watering and removing surplus soil to a distance of n exc 50m and making good surface in soft/loose soil, complete all as specified and directed.
M&L PCC 1:3:6 type C-2, using 40 mm graded stone aggregate, as in foundation, filling, mass concreting etc, complete all as specified and directed.
S & F Joist, channel, MS pipe, angel, flat, or tee section as in posts and struts in fencing including drilling holes notching for wire etc, flat iron fillet (for securing wire mesh/chain link fencing) incl all necessary drilling riveting, bolts etc. and similar work conforming to Fe 290 Gde E-165, complete all as specified and directed.
M&L 100 mm thick plain cement concrete 1:2:4 type B-1 (using 20mm graded stone aggregate) as in floor, sub floor, sub base etc, complete all as specified and directed.
M&L for forming contraction (dummy) joints 65mm deep 10mm wide filled with sealing compound grade 'B', complete all as specified and directed.
Excavation in trenches not exc 1.5 m wide and exc 1.5m but not exc 3.0 m in depth for foundation etc or for shafts, wells, cesspits, pier holes etc n. exc 10 sqm on plan and getting out in soft and loose soil, complete all as specified and directed.
M&L 450 mm dia Reinforced concrete pipes, class NP3, laid and jointed complete with collars, complete all as specified and directed.
Demolition of cement concrete (unreinforced) in ground floor and pavings n.exc 15 cm thickness (below or above GL), complete all as specified and directed.
Demolition of brick work or stone boulder masonry built in cement mortar including all quoins, arches, pillars etc. but excluding ashlars facing, dressed stone work & precast concrete articles, complete all as specified and directed.
Demolition of concrete of any description and in any position not otherwise specifically provided for cement concrete (unreinforced), complete all as specified and directed.
Dismantling of corrugated or semi corrugated asbestos cement sheets in roof covering including ridges, complete all as specified and directed.
M&L 75 mm thick plain cement concrete 1:2:4 type B-1 (using 20mm graded stone aggregate) as in floor, sub floor, sub base etc, laid in panels, surfaces finished even and smooth without using extra cement, complete all as specified and directed.
M&L 25 mm thick plain cement concrete 1:2:4 type B-0 (using 12.50mm graded stone aggregate) as in floor, sub floor, sub base etc, complete all as specified and directed.
Formwork (for fair finished surfaces) to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including supports, overhangs, etc. also splays between floors and beams, etc., complete all as specified and directed.
M&L RCC 1:2:4 type B-1 using 20 mm graded stone aggregate, as in beams, cantilevers, bressumers, lintels etc over 1.5 m in span complete all as specified and directed.
S&F Anodised powder coated aluminium frame for doors, windows, ventilators (having minimum powder coating thickness of 50micron) with one or more rebates including joining cleat for fixing etc. complete all as specified and directed.
S&F Anodised powder coated (minimum thickness of powder coating 50micron) aluminium door shutters, aluminium section weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber neoprene packing, handles 2 Nos in each door, hinges, anodised aluminum snap beading screws etc. complete all as specified and directed.
S&F Anodised powder coated (minimum thickness 50micron) aluminium window and ventilator shutters, fixed type without sash bar, aluminium section weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws etc. complete all as specified and directed.
Supply only sheet glass 5.5 mm thick, ordinary quality, cut to size as required at site, complete all as specified and directed. (Cost of fixing of glass shall be deemed included in the unit rates of aluminium door/window shutters)
S&F Mortice lock, vertical type, size 100 mm brass body consisting of 2 levers, complete all as specified and directed.
S&F 150 mm size aluminium handles, cast type, anodised, complete all as specified and directed.
S&F Double action floor spring hydraulically regulated made up of minimum 1.25 mm thick aluminium alloy sheet foundation box, main body with stainless steel cover, governing pivot made of brass, other parts made of mild steel heavy duty and fixed, complete all as specified and directed.
S&F 150 mm long aluminium anodised barrel tower bolts of extruded section and fixed, complete all as specified and directed.
Taking down chowkhat or frames not exc 1.50 Sqm each with shutters (without taking off shutters from the frame), complete all as specified and directed.
Taking down chowkhat or frames exc 1.50 Sqm and not exc 4.00 Sqm each with shutters (without taking off shutters from the frame), complete all as specified and directed.
M&L Screed bed or bedding layer of cement mortar 1:6, 20 mm thick for laying floor finishes, complete all as specified and directed.
M&L for non skid ceramic coloured tiles, 7 to 8mm thick (square/rectangular) area of each tile exceeding 0.06 Sqm but not exceeding 0.11 Sqm, in floors etc, set and jointed in neat cement slurry and pointed in coloured cement to match the shade of tiles, complete all as specified and directed.
M&L for non skid ceramic coloured tiles, 7 to 8mm thick (square/rectangular) area of each tile exceeding 0.06 Sqm but not exceeding 0.11 Sqm, in skirting/dado etc, set and jointed in neat cement slurry and pointed in coloured cement to match the shade of tiles, complete all as specified and directed.
M&L chequered cement concrete tiles 20 cm x 20 cm by 25 mm thick, set jointed and pointed in neat cement slurry with grey cement and pigments as in floors, complete all as specified and directed.
Taking down cement plaster any description/thickness on brick or stone walls etc including raking out joints, hacking for key, scrubbing down with water etc, complete all as specified and directed.
M&L for preparation of new plastered surfaces and applying three coats of White wash on walls, complete all as specified and directed.
S&F rolled mild steel as in Plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, without any attachment, conforming to Fe-410-W (Gde-E- 250) quality - B, complete all as specified and directed.
M&L mild steel work as in Hand rails, half round or other stock section or core for wooden hand-rail straight portion, drilled and countersunk for balusters running bars, for doors, balusters, nosing to steps including embeding in concrete and screwing etc. wind ties for roof including securing bolts; posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc.; flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc., and similar work conforming to Fe-290 Gde E-165, complete all as specified and directed.
M&L for rolled mild steel work as in joist, channels, angle, tube or Tee section fixed independently without connecting plates etc, cut to ordinary length ie 20 mm of the length indicated, conforming to Fe-410-W (Gde-E- 250) quality - B, complete all as specified and directed.
Preparation of old painted surface of steel or iron work of any description, over 10cm in width or girth, not otherwise described and applying one coat of synthetic enamel paint, complete all as specified and directed.
S & F sub main wiring using approved colour coding (Phase-red, Neutral-black, Earth-green) complete with two single core FRLS PVC insulated and unsheathed stranded copper conductor cable 10 sqmm as current carrying conductor and as neutral cable, voltage rating 1100 volt, ISI marked drawn in and including concealed PVC conduit ISI marked of dia not less than 25 mm and thickness 2 mm with stranded accessories along with one run of FRLS PVC green colour insulated, unsheathed, stranded copper conductor of size 10 sqmm, complete all as specified and as directed . Notes: (a) Two runs of single core FRLS PVC cable with one run of earth contunity conductor and conduit shall be measured as one unit. (b) Cost of cutting chases in wall for concealling conduit and making good to match with existing finish shall be deemed included in the quoted unit rate.
S&F sheet metal enclosure with a two pin and earth plug and socket complete with one single pole MCB of 240 Volts, 20 Amps, C series, 10 KA, complete all as specified and directed.
G S CONSTRUCTION
Sabitri Jhunu Enterprise
M/s SKP CONSTRUCTION
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .