Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹32.1 LAccepted-AOC 1 14 SUJAL MANSION B BLOCK BHANGWADI KALBADEVI ROAD MUMBAI 400 002 | MUMBAI | MAHARASHTRA | 400002 | L1 | Accepted-AOC BEING LOWEST | |
| 2 | L2₹39.3 L+₹5.5 L (16.1%)Rejected-Finance E 84 OF HQ CWE NW MUMBAI AGE 87 1 3 GEETA NAGAR NAVY NAGAR COLABA MUMBAI 400 005 | MUMBAI | MAHARASHTRA | 400005 | L2 | Rejected-Finance BEING OTHER THAN LOWEST | |
| 3 | L3₹41.8 L+₹7.9 L (23.3%)Rejected-Finance NOT AVAILABLE | L3 | Rejected-Finance BEING OTHER THAN LOWEST |
Tender Value
₹50 L
EMD Value
₹1 L
Closing Date
13 Sept 2024, 6:00 pmClosed
GE NW NAVY NAGAR COLABA MUMBAI
GE NW NAVY NAGAR COLABA MUMBAI
REPAIR MAINTENANCE AND REPLACEMENT OF UNSERVICEABLE METER PANELS CONTROL SWITCHGEARS SHAFT WIRING CABLE TRUNKING AND DISTRIBUTION BOXES OF HIGH RISE BUILDING AT RS COLABA UNDER GENW NAVY NAGAR COLABA MUMBAI
2024_MES_667007_1
8406/E8
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
GE NW NAVY NAGAR COLABA MUMBAI
Class D and Category b(I)
8 documents required · 8 mandatory
₹500
GE NW NAVY NAGAR COLABA MUMBAI
₹1 L
Yes
3 Oct 2024
20 Jul 2024
16 Sept 2024
20 Jul 2024
13 Sept 2024
3 Aug 2024
20 Jul 2024 - 10 Aug 2024
Amount
S&F in replacement of MCB DB SPN conforming to as per IEC 61439-3 and IP 43, IK 09 with acrylic door, 4 way complete with din rail, Neutral and Earthing bar after taking out the old unserviceable DBs, connection complete and making good the disturbed surfaces by plastering or PCC work inclding distembering to the affetced to walls. Make : Legrand/Havells/Siemens/L&T
All as per item No. 1.00 above but MCB DB SPN 8 way.
All as per item No. 1.00 above but MCB DB SPN 12 way.
S&F in replacement of MCCB DB VTPN 4 way as per IEC 61439-3 Suitable for Flush /Surface mounting with 250 A Copper Busbar for each phase with 2 Neutral bar, 2 Earthbar and Cable ties for Cable management fully insulated busbar & shrouded Neutral bars improved Pan assembly for ease of installation prefitted masking sheet reversible metalic door for IP 43 & IP 54 DB's with provision for 100 Amp 4pole MCCB as incomer and SP/TP MCB's as outgoing complele all as specified and directed. Make : Legrand/Siemens/Schneider/ABB
All as per item No. 4.00 above but MCCB DB VTPN 8 way.
S&F in replacement of MCCB 125A, 16kA, 4P, Thermal magnetic release , Ics=100% Icu . Make : Legrand/Siemens/Schneider/ABB
S&F in replacement of MCB TP 63A, 10kA, 415V. Make : Legrand/Siemens/Schneider/ABB
S&F in replacement of MCB SPN, 32 Amp, 10 KA, 230 Volt. Make : Legrand/Havells/Siemens/L&T
S&F in replacement of MCB SP 40A, 10kA, 240V. Make : Legrand/Siemens/Schneider/ABB
S&F in replacement of MCB, single pole, upto 20 Amp, 10 KA, 230 Volt. Make : Legrand/Havells/Siemens/L&T
S & F in replacement with cable PVC insulated, PVC sheathed, armoured, FRLS, 1100V grade, 2 core 6 sqmm stranded copper conductor electric cable laid on wall/ roof/ duct complete with proper saddling and connecting to DBs with glands including taking out existing unserviceable cable complete all as specified.
Supply and fixing of DLP PVC trunking system with all connected fittings for fixing on wall ceiling surfaces (end, joint of lid, joint of body, interior angle, exterior angle, flat angle, derivation) confirming standard EN 50085-2-1 of under mentioned size and refixing/resaddeling of all dismantalled UG cables/submain inside the trunking and made connection as specified and directed :
PVC truncking 80X50MM
Flexible cover 65MM width
Clip on partition
Base joint for tuncking
Joint for 65MM width cover
Flat angle for 80X50-DLP TRU
Internal angles adj 80-100 degree
External angles adj 60-120 degree
Taking out old existing unarranged communications cable/conduits/casing caping/Lightening Protection cable from wall surfaces and keep a side and refixing the same after making good of wall surfaces under cable trunking/trays or using saddling complete all as specified and directed.
Taking down carefully copper/ aluminium point wiring ie. light, fan, socket or power/ points complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets etc. and making good disturbed surfaces of ceiling, walls, floors, etc.
Material and labour for point wiring for one light/Exhaust/Ceiling fan/6 Amp socket on independent board/Bell point complete with proper colour coding using, 1100 volts grade, 1.5 Sqmm, PVC insulated FRLS, unsheathed wire with multi stranded copper conductor conforming to IS-694, part-II, ISI marked and including PVC casing and caping not less than 25 mm size, ISI mark with all accessories on wall/ceiling /floor/roof etc, including 1.5 Sqmm, PVC insulated, FRLS, unsheathed, 1100 volts multistranded copper conductor green colour as continuous earth wire connected to common earth dolly all as specified and directed for the following :- NOTE : Circuit conductor from MCB DB to Switch boards should not be less than 2.5sqmm and no extra cost will be paid on this aspect..
All as per item No. 15.00 above but 3 pin socket outlet, 5 Amps on the same board with other switches.
All as per item No 15.00 above but with 2.5 sqmm cable for one three pin 15 Amps socket out let controlled by one switch.
S & F modular switch, 1 module, single pole one way 6 Amp conforming to IS:3854 and ISI marked complete all as direcred. Make - Crabtree(Athena)/Anchor(Penta)/Legrand(Britzy)
S & F in replacement with modular switch, 1 module, single pole one way 6 Amp conforming to IS:3854 and ISI marked complete all as direcred. Make - Crabtree(Athena)/Anchor(Penta)/Legrand(Britzy)
S & F modular socket 6A, 3 pin, 2 module conforming to IS:1293 : 2019 and ISI marked complete all as direcred. Make - Crabtree(Athena)/Anchor(Penta)/Legrand(Britzy)
S & F in replacement with modular socket 6A, 3 pin, 2 module conforming to IS:1293 : 2019 and ISI marked complete all as direcred. Make - Crabtree(Athena)/Anchor(Penta)/Legrand(Britzy)
S & F modular switch, 1 module, single pole one way 16 Amp conforming to IS:3854 and ISI marked complete all as direcred. Make - Crabtree(Athena)/Anchor(Penta)/Legrand(Britzy)
S & F in replacement with modular switch, 1 module, single pole one way 16 Amp conforming to IS:3854 and ISI marked complete all as direcred. Make - Crabtree(Athena)/Anchor(Penta)/Legrand(Britzy)
S & F modular socket 6/16A, 3 pin, 2 module conforming to IS:1293 : 2019 and ISI marked complete all as direcred. Make - Crabtree(Athena)/Anchor(Penta)/Legrand(Britzy)
S & F in replacement with modular socket 6/16A, 3 pin, 2 module conforming to IS:1293 : 2019 and ISI marked complete all as direcred. Make - Crabtree(Athena)/Anchor(Penta)/Legrand(Britzy)
S & F modular stepped type fan regulator, 2 module, single pole one way ISI marked. Make - Crabtree(Athena)/Anchor(Penta)/Legrand(Britzy)
S & F in replacement with modular stepped type fan regulator, 2 module, single pole one way ISI marked. Make - Crabtree(Athena)/Anchor(Penta)/Legrand(Britzy)
S & F modular bell push switch, 1 module, single pole one way 6Amp ISI marked. Make - Crabtree(Athena)/Anchor(Penta)/Legrand(Britzy)
S & F in replacement with modular bell push switch, 1 module, single pole one way 6Amp ISI marked. Make - Crabtree(Athena)/Anchor(Penta)/Legrand(Britzy)
Taking out old wooden/PVC board and disconnecting all electric connection from switches, board and S & F in replacement with modular PVC Gang box of 8 module, ISI marked for mounting of modular switches and sockets including blank plate for blank module. Make - Crabtree(Athena)/Anchor(Penta)/Legrand(Britzy)
All as per Item No- 30.00 above but of modular PVC Gang box, 4 module.
All as per Item No- 30.00 above but of modular PVC Gang box, 3 module.
All as per Item No- 30.00 above but of modular PVC Gang box, 1/2 module.
S&F modular white cover plate with frame, 8 module.
S&F modular white cover plate with frame, 4 module.
S&F modular white cover plate with frame, 3 module.
S&F modular white cover plate with frame, 1/2 module.
Taking down unserviceable FTL/batten fittings with supply and fix LED batten fitting 10 Watt, 240V, 2ft CDL/NW comprises of extruded channel in thermally conductive material with decorative end cap and high translucent serration milky white diffuser of high optically efficient plastic FR grade. The luminaire is pre-wired with high efficiency electronic driver having operating voltage 140-270V, P.F >0.95, THD <20% and IP20 protected alongwith provision of two Nos of PVC box of size 75x75x20mm for mounting light fittings including ceiling rose. The contractor shall provide test certificate from authorized lab. Make of Light Fitting : Wipro/Crompton/Philips/Bajaj/Polycab
S & F in replacement with Analog time switch 3P Module, 24 hours program, programmable every 15 min., backup of 100 hours, current capacity 16A for ON/OFF controlling of security lights complete all as directed.
S & F in replacement with power contactor 3 pole AC, with 240 volt coil, 32 Amp rating conforms to IS / IEC 60947-4-1 for ON/OFF controlling of security lights complete all as directed.
S & F ceiling rose with earth terminal connection, 3 terminal/ PVC/ polycarbonate, isolated body of size 60x50mm.
S & F in replacement with ceiling rose with earth terminal connection, 3 terminal/ PVC/ polycarbonate, isolated body of size 60x50mm.
S & F in replacement with electric bell ding dong, AC, 230V single pole.
Taking down old unserviceable and Supply, install, testing and commissioning of meter cabin panel mounted on angle iron frame 40 x 40 x 5 mm grouted on floor,cubical indoor type for 415V, 3 phase, 4 wire made out of CRCA sheet not less than 2 mm thick , vermin proof factory fabricated, CPRI approved, front open hinged door with locking arrangement powder coated, individual compartment for MCCBs and 400 Amps rated copper bus bar alongwith compartment for fixing of Electronic Smart Prepaid Meters, top and bottom cable entry with proper size glands including provisions of vision glasses for meter readings as directed. Meter cabin panel shall be comprising of the following :- (a) MCCB 4 pole, 160 Amps, 25 kA, 415 volt, thermal magnatic realease type, Ics=100% Icu -01 Nos, (as incomer) Make-Legrand/Siemens/Schneider. (b) MCCB 4 pole, 63/100 Amps, 16 kA, 415 volt, thermal magnatic realease type, Ics=100% Icu -03 Nos, (as outgoing) Make-Legrand/Siemens/Schneider. (c) MCB SPN 32 Amps 10 KA - 28 Nos Make-Legrand/Siemens/Schneider. (d) Smart electronic prepaid single phase Meter tamper proof, static meter of Class 1.0, 240 V, 50 Hz, 10 A-60 A conforming to IS-16444 and relevant IEC. - 28 Nos Make-L&T/HPLor other equivelent. (e) Digital type Voltmeter ( 0-500 Volts), 3 phase, 4 digit, high resolution, LED type with onsite programmability- 01 Nos. Make: Securemeters, Reshab or L&T. (f) Digital type Ampermeter ( 0-300 Amps) three phase with copper wound CT coil assy of suitable ratio & size Class I accuracy, 0.5 VA burden & onsite programmability- 01 Nos. Make: Securemeters, Reshab or L&T. (g) Indicating lamp LED type with holder key flush mounted, Red, Yellow, blue with toggle switch - 1 set ( set of three) as in incoming phases. (h) Tinned copper bus bar strips made of copper of size 40x5mm suitable length-(01Set of four) including provision of new vision glasses-28 Nos. (j) Submain cable 2 core 6 Sqmm copper conductor from MCB SPN to each Meters. (k) Making good the disturbed surface of meter cabin room if any damages occures during fixing/shifting of panel.
Note :- (i) Before fabrication of panel the contractor has to take approval from GE on drawing. (ii) All existing cable connections will be disconnected from old Panel carefully and re-connected with new Panel by providing glands and thimble all as directed by Engineer-in-Charge. (iii) Taking out old electronic energy meters from existing Meter panel and shall be deposited to MES store.
All as per Item No.44.00 above but scope of work including provision of housing the following accessories:- (a) MCCB 4 pole, 200 Amps, 25 kA, 415 volt, thermal magnatic realease type, Ics=100% Icu -01 Nos, (as incomer) Make-Legrand/Siemens/Schneider. (b) MCCB 4 pole, 125 Amps, 16 kA, 415 volt, thermal magnatic realease type, Ics=100% Icu -01 Nos, Make-Legrand/Siemens/Schneider. (c) MCCB 4 pole, 63/100 Amps, 16 kA, 415 volt, thermal magnatic realease type, Ics=100% Icu -03 Nos, Make-Legrand/Siemens/Schneider. (d) MCB SPN 32 Amps 10 KA - 30 Nos Make-Legrand/Siemens/Schneider. (e) Smart electronic prepaid single phase Meter tamper proof, static meter of Class 1.0, 240 V, 50 Hz, 10 A-60 A conforming to IS-16444 and relevant IEC. - 30 Nos Make-L&T/HPLor other equivelent. (f) Digital type Voltmeter ( 0-500 Volts), 3 phase, 4 digit, high resolution, LED type with onsite programmability- 01 Nos. Make: Securemeters, Reshab or L&T. (g) Digital type Ampermeter ( 0-300 Amps) three phase with copper wound CT coil assy of suitable ratio & size Class I accuracy, 0.5 VA burden & onsite programmability- 01 Nos. Make: Securemeters, Reshab or L&T. (h) Indicating lamp LED type with holder key flush mounted, Red, Yellow, blue with toggle switch - 1 set ( set of three) as in incoming phases. (j) Tinned copper bus bar strips made of copper of size 40x5mm suitable length-(01Set of four) including provision of new vision glasses-30 Nos. (k) Submain cable 2 core 6 Sqmm copper conductor from MCB SPN to each Meters. (l) Making good the disturbed surface of meter cabin room if any damages occures during fixing/shifting of panel. Note :- (i) Before fabrication of panel the contractor has to take approval from GE on drawing. (ii) All existing cable connections will be disconnected from old Panel carefully and re-connected with new Panel by providing glands and thimble all as directed by Engineer-in-Charge. (iii) Taking out old electronic energy meters from existing Meter panel and shall be deposited to MES store.
All as per Item No.44.00 above but scope of work including provision of housing the following accessories:- (a) MCCB 4 pole, 125 Amps, 16 kA, 415 volt, thermal magnatic realease type, Ics=100% Icu -01 Nos, (as incomer) Make-Legrand/Siemens/Schneider.
(b) MCCB 4 pole, 63/100 Amps, 16 kA, 415 volt, thermal magnatic realease type, Ics=100% Icu -03 Nos, Make-Legrand/Siemens/Schneider. (c) MCB SPN 32 Amps 10 KA - 29 Nos Make-Legrand/Siemens/Schneider. (d) Smart electronic prepaid single phase Meter tamper proof, static meter of Class 1.0, 240 V, 50 Hz, 10 A-60 A conforming to IS-16444 and relevant IEC. - 29 Nos Make-L&T/HPLor other equivelent. (e) Digital type Voltmeter ( 0-500 Volts), 3 phase, 4 digit, high resolution, LED type with onsite programmability- 01 Nos. Make: Securemeters, Reshab or L&T. (f) Digital type Ampermeter ( 0-300 Amps) three phase with copper wound CT coil assy of suitable ratio & size Class I accuracy, 0.5 VA burden & onsite programmability- 01 Nos. Make: Securemeters, Reshab or L&T. (g) Indicating lamp LED type with holder key flush mounted, Red, Yellow, blue with toggle switch - 1 set ( set of three) as in incoming phases. (h) Tinned copper bus bar strips made of copper of size 40x5mm suitable length-(01Set of four) including provision of new vision glasses-29 Nos. (j) Submain cable 2 core 6 Sqmm copper conductor from MCB SPN to each Meters. (k) Making good the disturbed surface of meter cabin room if any damages occures during fixing/shifting of panel. Note :- (i) Before fabrication of panel the contractor has to take approval from GE on drawing. (ii) All existing cable connections will be disconnected from old Panel carefully and re-connected with new Panel by providing glands and thimble all as directed by Engineer-in-Charge. (iii) Taking out old electronic energy meters from existing Meter panel and shall be deposited to MES store.
shree arihant constrution (BID ID -3082622)
SHREE JAGDISH FURNITURE CO. (BID ID -3084583)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .