Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹4.9 LAccepted-AOC | L1 | Accepted-AOC AOC | |
| 2 | L2₹5.0 L+₹2,052 (0.41%)Rejected-Finance VILL P O JAMBEDIA DIST BANKURA PIN 722139 | JAMBEDIA | BANKURA | WEST BENGAL | 722139 | L2 | Rejected-Finance 2nd lowest | |
| 3 | L3₹5.0 L+₹2,573 (0.52%)Rejected-Finance | L3 | Rejected-Finance 3rd lowest |
| Sl No | Description | Qty | Unit | MAGNET ELECTRIC WORKS L1 | UJJWAL MUKHERJEE L2 | MANDAL TRADERS L3 |
|---|---|---|---|---|---|---|
| 1.00 | Dismentling the existing damage , defective & non functioning Electrical accessories by Co's own tools & tackles by maintening normalcy as far as possible as per direction of EIC and the agency have to submit the dismantled Electrical Installations at the BSMC&H Electrical sub division by their own arrangements with full list of items. | 1 | Item | 2,980 ₹2,980 Lowest | 2,985 ₹2,985 | 2,985 ₹2,985 |
| 2.00 | Supplying and fixing 415V, TPN SFU with sheet steel enclosure on angle iron frame on wall with nuts bolts etc incl. S&F 3 nos DIN type HRC fuse. 100A, Make - Siemens/L&T. (At X-ray room) | 1 | Each | 7,912 ₹7,912 Lowest | 7,915 ₹7,915 | 7,916 ₹7,916 |
| 3.00 | Supplying and fixing 240/415 V Isolator on din rail of existing DBs and necessary connection Make-Legrand / Siemens, as to GS. (At Lokpur, Administrative building, OPD building & PMSSY building) 415 V, 63A FP | 8 | Each | 1,057 ₹8,456 Lowest | 1,060 ₹8,480 | 1,061 ₹8,488 |
| 4.00 | Supplying and fixing 240/415V, MCB of Breaking capacity 10kA & C characteristics on din rail of existing DBs and necessary connection Make-Legrand/ Siemens as to GS. (At SNCU) 415 V, 32A FP | 1 | Each | 1,497 ₹1,497 Lowest | 1,499 ₹1,499 | 1,499 ₹1,499 |
| 5.00 | Supplying and fixing MCB SS enclosure with IP-20/30 protection, powder coated provision for two/four pole MCB, concealed in wall after cutting the wall & mending good the damages to original finish incl. painting, connection & provision for earthing attachment 4 Way | 9 | Each | 396 ₹3,564 Lowest | 400 ₹3,600 | 399 ₹3,591 |
| 6.00 | Distribution wiring in 2 x 22/0.3 (1.5 sqmm) single core stranded 'FRLS' PVC insulated & unsheathed copper wire (Finolex/ Havells/KEI approved by EIC) in 20mm size PVC rigid conduit 'FR' (Precision make), with 1x22/0.3 (1.5 sqmm) single core stranded 'FRLS' PVC insulated & unsheathed copper wire for ECC, with drop Concealed type if reqd as per direction of EIC to light/fan/call bell points with Piano Key type switch fixed on MS CRC sheet metal (16 SWG) switch board cum JB on wall complete with 2 no. suitable size “Ph & N” copper bar incl. bakelite/Perspex (wall matching color) top cover 3 mm thick and incl. 175 mm x 100 mm x 65 mm inspection box, making earthing attachment, painting the MS box and mending good the damages to original finish. (At Pediatrics OPD, Natun Bhavan & Ladies Hostel) Average run 10 mtr | 19 | Point | 1,250 ₹23,750 Lowest | 1,255 ₹23,845 | 1,256 ₹23,864 |
| 7.00 | Supply & Fixing 240 V, 6A, plug socket with separate 6A Piano key type switch (Brand approved by EIC) on sheet metal switch board embedded in wall incl. S & F 150x100x65mm MS (16SWG) switch board and bakelite/perspex top cover of 3mm thick by Brass screws after making housing for switch by cutting bakelite/perspex cover and making necessary connections as required. (At Labour room, PMSSY building, OPD building & Ladies hostel) | 11 | Each | 255 ₹2,805 Lowest | 260 ₹2,860 | 260 ₹2,860 |
| 8.00 | Supply & Fixing 240 V, 1 x 20A, plug socket with separate 20 A Piano key type switch (Brand approved by EIC) on sheet metal switch board embedded in wall incl. S & F150 x 100 x 65mm MS (16SWG) switch board and bakelite /perspex top cover of 3mm thick by Brass screws after making housing for switch by cutting bakelite/perspex cover and making necessary connections as required. (At SNCU, Gynae OT, SRB hostel, Natun Bhavan, OPD building, Cath Lab & Antinatal ward) | 13 | Each | 359 ₹4,667 Lowest | 363 ₹4,719 | 360 ₹4,680 |
| 9.00 | Supply & Fixing 240 V, 3 nos. 6A, & 1 no. 20A plug socket with separate 3 nos. 6 A & 1 no. 20A Piano key type switch, indicator & 20A switch type SP MCB (Brand approved by EIC) on sheet metal switch board embedded in wall incl. S & F 240x200x65mm MS (16SWG) switch board and bakelite/perspex top cover of 3mm thick by Brass screws after making housing for switch by cutting bakelite/perspex cover and making necessary connections as required. (SNCU & PMSSY building) | 5 | Each | 942 ₹4,710 Lowest | 945 ₹4,725 | 945 ₹4,725 |
| 10.00 | Supply & Fixing 240 V, 25 A, 3 pin Modular type plug socket (Brand approved by EIC), without plug top and switch with 2 Module GI Modular type switch board with top cover plate flushed in wall and making necy. connections with PVC Cu wire and earth continuity wire etc as per G.S. (At OPD building) | 7 | Each | 442 ₹3,094 Lowest | 445 ₹3,115 | 446 ₹3,122 |
Tender Value
Refer Docs
EMD Value
₹9,080
Closing Date
31 Dec 2025, 11:55 amClosed
AE/BMCESD/PWD
Kenduadihi, Gobindanagar Hospital campus, Bankura-722102
Annual Maintenance estimate of the E.I. work at MCH Building at Bankura Sammilani Medical College and Hospital Campus under BSMC and H, Bankura.------ Renovation and rectification of E.I work at various location of hospital campus under BSMCH
2025_WBPWD_964673_1
WBPWDTE/AE/BMCESD/NIQ-23/Q of 2025-2026
Open Tender
ELECTRICAL WORKS ORG
Item Wise
14 days
AE/BMCESD/BANKURA
Please refer Tender documents.
3 documents required · 3 mandatory
₹9,080
Yes
20 Jul 2026
1 Dec 2025
6 Jan 2026
1 Dec 2025
31 Dec 2025
18 Dec 2025
Amount
Dismentling the existing damage , defective & non functioning Electrical accessories by Co's own tools & tackles by maintening normalcy as far as possible as per direction of EIC and the agency have to submit the dismantled Electrical Installations at the BSMC&H Electrical sub division by their own arrangements with full list of items.
Supplying and fixing 415V, TPN SFU with sheet steel enclosure on angle iron frame on wall with nuts bolts etc incl. S&F 3 nos DIN type HRC fuse. 100A, Make - Siemens/L&T. (At X-ray room)
Supplying and fixing 240/415 V Isolator on din rail of existing DBs and necessary connection Make-Legrand / Siemens, as to GS. (At Lokpur, Administrative building, OPD building & PMSSY building) 415 V, 63A FP
Supplying and fixing 240/415V, MCB of Breaking capacity 10kA & C characteristics on din rail of existing DBs and necessary connection Make-Legrand/ Siemens as to GS. (At SNCU) 415 V, 32A FP
Supplying and fixing MCB SS enclosure with IP-20/30 protection, powder coated provision for two/four pole MCB, concealed in wall after cutting the wall & mending good the damages to original finish incl. painting, connection & provision for earthing attachment 4 Way
Distribution wiring in 2 x 22/0.3 (1.5 sqmm) single core stranded 'FRLS' PVC insulated & unsheathed copper wire (Finolex/ Havells/KEI approved by EIC) in 20mm size PVC rigid conduit 'FR' (Precision make), with 1x22/0.3 (1.5 sqmm) single core stranded 'FRLS' PVC insulated & unsheathed copper wire for ECC, with drop Concealed type if reqd as per direction of EIC to light/fan/call bell points with Piano Key type switch fixed on MS CRC sheet metal (16 SWG) switch board cum JB on wall complete with 2 no. suitable size “Ph & N” copper bar incl. bakelite/Perspex (wall matching color) top cover 3 mm thick and incl. 175 mm x 100 mm x 65 mm inspection box, making earthing attachment, painting the MS box and mending good the damages to original finish. (At Pediatrics OPD, Natun Bhavan & Ladies Hostel) Average run 10 mtr
Supply & Fixing 240 V, 6A, plug socket with separate 6A Piano key type switch (Brand approved by EIC) on sheet metal switch board embedded in wall incl. S & F 150x100x65mm MS (16SWG) switch board and bakelite/perspex top cover of 3mm thick by Brass screws after making housing for switch by cutting bakelite/perspex cover and making necessary connections as required. (At Labour room, PMSSY building, OPD building & Ladies hostel)
Supply & Fixing 240 V, 1 x 20A, plug socket with separate 20 A Piano key type switch (Brand approved by EIC) on sheet metal switch board embedded in wall incl. S & F150 x 100 x 65mm MS (16SWG) switch board and bakelite /perspex top cover of 3mm thick by Brass screws after making housing for switch by cutting bakelite/perspex cover and making necessary connections as required. (At SNCU, Gynae OT, SRB hostel, Natun Bhavan, OPD building, Cath Lab & Antinatal ward)
Supply & Fixing 240 V, 3 nos. 6A, & 1 no. 20A plug socket with separate 3 nos. 6 A & 1 no. 20A Piano key type switch, indicator & 20A switch type SP MCB (Brand approved by EIC) on sheet metal switch board embedded in wall incl. S & F 240x200x65mm MS (16SWG) switch board and bakelite/perspex top cover of 3mm thick by Brass screws after making housing for switch by cutting bakelite/perspex cover and making necessary connections as required. (SNCU & PMSSY building)
Supply & Fixing 240 V, 25 A, 3 pin Modular type plug socket (Brand approved by EIC), without plug top and switch with 2 Module GI Modular type switch board with top cover plate flushed in wall and making necy. connections with PVC Cu wire and earth continuity wire etc as per G.S. (At OPD building)
Supply & Fixing 240 V,25 A, 3 pin Modular type plug top with indicator (Brand approved by EIC) & necy. Connections. (At OPD building)
Supplying & Fixing Industrial Plug & Socket board with 415 V, 30A, TPN & Earth Metal Industrial Plug socket & 30A Industrial top incl. S&F 32 A TPN/FP MCB breaking capcity 10kA (C- Curve) in SS enclosure fixed on wall and cecessary conection. (At PMSSY building)
Distribution wiring in 1.1 KV single core stranded 'FRLS' PVC insulated & unsheathed copper wire (Finolex / Havells/ RR Kable / Gloster /approved by EIC) in 20mm size PVC rigid conduit 'FR' (Precision make) incl. necy. fittings as required. 2 x 1.5 sqmm + 1 x 1.5sqmm (for Separate Plug)
2 x 2.5 sqmm + 1 x 1.5sqmm (for Power plug )
2 x 4.0 sqmm + 1 x 2.5sqmm (for Power plug & AC machine )
4 x 6.0 sqmm + 2 x 4.0 sqmm (for Industrital socket & AC machine )
Finishing of the PVC insulated wire ends by socketting with pin/ ring type copper sockets and insulated tapes etc., including supplying sockets, tapes. as per GS 1.5 sq mm
Supplying and fixing compression type gland complete with brass gland, brass ring & rubber ring for dust & moisture-proof entry of XLPE/PVC armoured cables as below : 4 core 95 sqmm
Finishing the end of following XLPE/PVC armoured cables by crimping method incl. supplying and fixing solderless socket (Dowels make), tapes, anticorrosive paste & jointing materials . 4 core 95 sqmm
Supply of 250 V 50 HZ high flo oscillating type metal body Wall Bracket( Tornedo - 2 ) fan operated by pull cord switch with inbuilt regulator ( Make -CG/ Orient/ PWD Approved) 18" (450 mm). (For MCH building, OPD building, Main building, PMSSY building & Chumery Hostel)
Fixing of Wall Bracket on wall with necessaryS&F rag bolts, nuts & washers (6 mm dia x 62 mm long) or as reqd. incl. S&F 24/0.20 PVC insulated flexible copper wire 0.5 mt. length etc to complete the installation and mending good the damages as per direction of EIC.
Supply of exhaust fan (Make -- EPC, Heavy duty/equivalent make) of following sizes as per direction of EIC.(For Rabin Hall) 30 cm (18") 1420 RPM
Fixing only exhaust fan after making hole in wall and making hole in wall good damages and smooth cement finish etc. as practicable as possible and providing necy. length of PVC insulated wire and making connection for exhaust of dia. 30 cm (18")
Supply & Fixing Emergency Bulb 9 Watt Rechargeable Inverter LED Bulb for Home Cool Daylight. (At Central Kitchen & Old Nurses' Hostel)
Supply & Delivery of 4 feet twin commercial LED type fluorescent light fittings complete with all accessories similar to Philips make cat No. TMC 501 P2 x T - LED 22 W P3 242 with 2 nos x Master LED Tube lamp of 1200 mm , 18W 865 T 81- 2100 ln corresponding to Wipro / Bajaj / Crompton/ Havells / PWD approved as per direction of EIC. (For Ladies hostel)
Fixing only single/twin fluorescent light fitting suspended 25 cm bellow the ceiling with 2 No. 20 mm dia EI conduit (14 SWG) supports fixed with “L” type MS clamp whose one side fixed on ceiling with sutable size 4 nos. fastener and other side connected with the conduit with suitable size of bolts and nuts incl. S&F EI conduit, “L” type (125mmx125mm) 6mm thick and 25mm with MS clamps and connecting the length of PVC insulated wire and mending good damages to original finish and painting etc. by 2x24/0.20 mm (1.5sqmm.) flexible copper wire of 1.10 mt. length.
Supply & Fixing of 250V 50 HZ OLP- 30A single phase A.C Starter (Make -Electron, / PWD Appvd) suitable for 1.5 / 2.0 TR Airconditioner Machine incl S & F suitable size G I box (16 SWG) flushed in wall with voltage check, Amp check, Time check incl. making connection as per direction of EIC. (At OPD building)
Supply, Installation, Testing & Commissioning of 12 Volts, 7 Ah, CHLORIDE SAFEPOWER Sealed lead-acid battery with 3 years warranty (Make - Exide / Amaron )
Supply, Installation, Testing & Commissioning of 12 Volts, 12 Ah, CHLORIDE SAFEPOWER Sealed lead-acid battery with 3 years warranty (Make - Exide / Amaron )
Labour charge for repairing of 230V, 2 Kw Geyser as per direction of the EIC.
Cost for supply and fixing Geyser heat coil as per sample replacing existing damaged one as per direction of EIC.
Brick work at the wall to fill the existing location of the Window AC machine and Plastering on the new brick work of wall & 2 coat colour work on plaster to original finish as per EIC.
UJJWAL MUKHERJEE (BID ID -7678861)
MANDAL TRADERS (BID ID -7678819)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .