Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹2.1 LAdmitted-Finance | ₹2.1 L | L1 | Admitted-Finance |
| Sl No | Description | Qty | Unit | DHANSHRI ENTERPRISES L1 |
|---|---|---|---|---|
| 1.00Supply and fixing water supply tank, pipeline for Class III quarters and Office from RO Plant situated in GLR Sy No.269 Belgaum Cantonment. | ||||
| 2.00 | Dismantling of Stone/Concrete paver block slabs and tiles of any description or thickness in floors, aprons etc. of laid dry or laid dry and pointed. | 60 | Sqm | 30 ₹1,800 |
| 3.00 | Demolition of Cement concrete (unreinforced) in ground floors and pavings n exc 15 cm thickness (below or above ground level) | 3.75 | Cum | 350 ₹1,312.50 |
| 4.00 | Earth work in excavation by mechanical means (Hydraulic excavator)/ infoundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m for all kind of soil. | 15.15 | Cum | 350 ₹5,302.50 |
| 5.00 | Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out Hard/dense soil | 16.2 | Cum | 350 ₹5,670 |
| 6.00 | Providing and fixing Unplasticised Polyvinyl Chloride (uPVC)/ HDPE 25mm dia pipes, for cold water supply including all uPVC/HDPE plain & brass threaded fittings This includes jointing of pipes & fittings with one step uPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge for External work. | 239 | Mtr | 350 ₹83,650 |
| 7.00 | Providing and fixing Unplasticised Polyvinyl Chloride (uPVC) 15mm dia pipes, for cold water supply including all uPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step uPVC solvent cement, trenching, refilling & testing of joints complete as per direction
of Engineer in Charge for External work. | 25 | Mtr | 300 ₹7,500 |
| 8.00 | S&F Rotational moulded polyethylene 1000Ltr water storage tanks (cylindrical vertical with closed top) hoisted and fixed in position all as specified. | 1 | Each | 15,000 ₹15,000 |
| 9.00 | S&F Rotational moulded polyethylene 2000Ltr water storage tanks (cylindrical vertical with closed top) hoisted and fixed in position all as specified. | 1 | Each | 27,000 ₹27,000 |
| 10.00 | Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm. of all kind of soil. | 29.27 | Cum | 60 ₹1,756.20 |
Tender Value
₹2.2 L
EMD Value
₹5,000
Closing Date
19 Jan 2026, 4:00 pmClosed
CEO, Cantonment Board, Belagavi
Office of the Cantonment Board, Belagavi
Supply and fixing water supply tank, pipeline for Class III quarters and Office from RO Plant.
2026_DGDE_748178_1
No. 5PWD/92/1557
Open Tender
Civil Works - Others
90 days
SY. No. 269 Belagavi Cantt
Class IV (Karnataka State PWD)/ Class E of MES or other equivalent registration in building category.
2 documents required · 2 mandatory
₹300
CEO, Cantonment Board
₹5,000
Yes
31 Jan 2026
12 Jan 2026
20 Jan 2026
12 Jan 2026
19 Jan 2026
12 Jan 2026
Supply and fixing water supply tank, pipeline for Class III quarters and Office from RO Plant situated in GLR Sy No.269 Belgaum Cantonment.
Dismantling of Stone/Concrete paver block slabs and tiles of any description or thickness in floors, aprons etc. of laid dry or laid dry and pointed.
Demolition of Cement concrete (unreinforced) in ground floors and pavings n exc 15 cm thickness (below or above ground level)
Earth work in excavation by mechanical means (Hydraulic excavator)/ infoundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m for all kind of soil.
Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out Hard/dense soil
Providing and fixing Unplasticised Polyvinyl Chloride (uPVC)/ HDPE 25mm dia pipes, for cold water supply including all uPVC/HDPE plain & brass threaded fittings This includes jointing of pipes & fittings with one step uPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge for External work.
Providing and fixing Unplasticised Polyvinyl Chloride (uPVC) 15mm dia pipes, for cold water supply including all uPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step uPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge for External work.
S&F Rotational moulded polyethylene 1000Ltr water storage tanks (cylindrical vertical with closed top) hoisted and fixed in position all as specified.
S&F Rotational moulded polyethylene 2000Ltr water storage tanks (cylindrical vertical with closed top) hoisted and fixed in position all as specified.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm. of all kind of soil.
Removing excavated material exc. 1.50 km but n exc. 5 km and depositing where directed by the Engineer in Charge
Refixing of Machine pressed precast concrete interlocking paver block any shape and size confirming to IS 15658-2006 of 60 mm thickness, M-35 Grade, Except tiles including grit base (6mm) of 75mm thickness and old materials.
M&L Cement concrete in foundations, filling and mass concrete Type B2 1:2:4 (40 mm graded aggregate)
S&F 1HP Open well Submersible Pump with Control Panel, with a head of 100-150 feet, a discharge range of 2.2-0.3 lps. The Submersible Pumps are designed to be mounted horizontally and are capable of operating on voltages ranging from 160-240 Volt including neseccery fittings Complete as per direction of Engineer in Charge.
S&F 0.50 HP Open well Monoblock Pump with Control Panel, with a head of 10 to 15 feet, a discharge range of 2.2-0.3 lps. The Monoblock Pumps are designed to be mounted horizontally and are capable of operating on voltages ranging from 160-240 Volt including neseccery fittings Complete as per direction of Engineer in Charge.
Refixing of Machine pressed precast concrete interlocking paver block any shape and size confirming to IS 15658-2006 of 60 mm thickness, M-35 Grade, Except tiles including grit base (6mm) of 75mm thickness and old materials.
Please Enable Macros to View BoQ information
stage.html
html • 0.02 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.59 MB
ROpipeline.pdf
Tender Documents • 5.43 MB
BOQ_837855.xls
BOQ • 0.32 MB
Download all tender documents and submit your bid