Loading…
Loading…
| # | Company | Quoted % | Amount | Rank | Status |
|---|---|---|---|---|---|
| 1 | L1₹3.0 LAdmitted-Finance | -6.70% | ₹3.0 L | L1 | Admitted-Finance |
Tender Value
₹3.2 L
EMD Value
₹6,460
Closing Date
18 Mar 2026, 5:30 pmClosed
EE PWD Elec Dn Ajmer
EE PWD Elec Dn Ajmer
Sound system work with Falls Ceiling Wall Panelling Sound System and Electricak Work at Town Hall Nagaur
2026_CEPWD_546324_4
NIT 49 2025-26 EE PWD Elec Dn Ajmer
Open Tender
Electrical Works
90 days
Ajmer
Refer NIT and Tender Doc
4 documents required · 4 mandatory
₹500
Egras in Fav of EE PWD Elec Dn Ajmer
₹6,460
Yes
EE PWD Elec Dn Ajmer
21 Mar 2026
15 Mar 2026
19 Mar 2026
15 Mar 2026
18 Mar 2026
15 Mar 2026
16 Mar 2026
S&F following sizes (dia.) of ISI marked MMS ( IS:9537 P - III ) PVC conduit along with ISI marked (IS:3419-1988) accessories as required in recess including making jhiri in the wall,clamps at suitable spacing, covering conduit and making good the same as required.
Supply and laying following size twin parallel type Speaker cables made with multi wire, bright annealed flexible bare electrolytic grade copper conductor, insulated with specially formulated transparent grade PVC compound, red strip for identification in existing conduit etc. as required.
Supply, Drawing and Testing of 4 pair, 23 AWG Solid Bare Copper wire insulated with PVC, U/UTP (Unscreened/Unshielded Twisted Pair), Category 6, Class E, 100 Ohm Impedance, Indoor Cable as per latest ammendments of ANSI/TIA/EIA-568 , The copper conductors should be balanced twisted in pairs, seperated by a cross-member fluted pair divider & protected by LSZH Jacket. Certified performance in a 4-connector configuration upto 100 Mtrs channel requirements & transmission frequencies ranging from 250 to 500 Mhz. in existing MS/PVC Conduits/casing capping including making connections to Information outlets and Patch Panels with jack & ferruling at both ends for identification with necessary tools for punching, stripping, crimping and testing etc as required complete in all respect.
Supply and Installation of unshielded/360 degree shielded PCB based Information outlets made of high impact plastic body with ABS, Flammability rating UL 94 V-0 with provision for protection against dust in jack or Faceplate, suitable for Cat 6/6A application complying to latest amendments, According. to Cat. 6/6A channel, It should support channel as well as components requirements of Cat 6/6A standards at frequencies 250/ 500 MHz. Cat 6/6A unshielded/shielded Jack should be suitable to terminate 4 pair, 23/24 AWG solid/stranded wire diameters, using 100 Ohm unshielded/shielded balance twisted pair cable, the jack should have toolless/impact termination on reliable copper tin plated Insulation displacement contact, with easy lock mechanism, It supports IEC 60603-7-4 and complied with ANSI/TIA 568 C.2 & ISO/IEC 11801 or latest standard. jack should be RJ11,RJ12 & RJ45 compatible. Should support Ethernet 1.2 Gb/s ATM,Digital video and broadband/baseband analog video, Voice over internet protocol (VOIP) Specifications in existing modular/MS Boxes along with necessary connections as required. All as per pre approved by Engineer in charge.
Cat 6, Un-sheilded Information Outlet
Supply & fixing of square Faceplate for Flush / Surface Mount Information Outlets Single/Dual or Quad Aperture with dust cover, material should be High-impact, flame retardant, thermoplastic, UL listed material, Suitable for RJ45 unshielded/shielded connection modules. Should match with I. O. OEM. Dimensions should be 86mm X 86mm as required complete in all respect. All as per pre approved by Engineer in charge.
Single Aperture
supply, Installation, Testing & Commissioning of Delegate mike Unit with fixed microphone and flexible stem prority button for Deligate mike microphone ,optioal chime tone facility for proceeding Delegate mike announcement with two headphone socket built in loudspeaker is automatcally muted when the microphone is on/off button Delegate mike unit should have a frequency responce 400hz to10hz ,length of microphone from base to steam should not be less than 488 mm in size ;nominal acoustic input 85 db SPL,dimensions (without microphone) (HxWxD) 50x135x135 mm; weight of unit should not be less then 1.2 kg ;operating temperature -5°C to +45°C,two 3.5mm (0.14 in) stereo headphone sockets; including make connecion testing etc complete as required.
SITC of 30 Watt speaker with taping facility having frequency range of 65Hz-20KHz@(-10db) with power handing of 200Watt continuous and more than 350 Watt @peak etc complete as required.
Supply & Installation of 240 Watt Mixer Amplifier Unit- for providing a crisp call or clear music with 4 microphone / line inputs, plus music source input, announcement only output, 3 wire volume override, with Mains power supply 230 VAC ±10%, 50 Hz (reduced power at lower mains), Inrush current 20 A , Power consumption 120W, Frequency response (Line) 80 Hz to 18 kHz (+1/‑3 dB @‑10 dB ref. rated output) Frequency response (Mic.) 80 Hz to 18 kHz (+1/‑3 dB @‑10 dB ref. rated output) Distortion <1%@ rated output power, 1 kHz Bass Control Max. ± 8 dB Treble Control Max. ± 8 dB, including making connection etc complete as required.
Supply, Installation, Testing & Commissioning of High−performance 15 meter HDMI male to HDMI male cable Wall plate for the interoperability in all respect to etc complete as required.
SITC of 1Phase Input, 1Phase Output Microprocessor control based Inverter with input voltage range of 180-260V and output voltage same as input 210V +/- 10%, output frequency of 50 +/- 0.1 Hz and 0.8 Output factor. Overall efficiency of upto 80%, Transfer time 15 msec & Sinewave output.Inverter should have LED/LCD Panel Display showing Mains ON, INV. ON, Charging/Charged.Inverter should have protection from Overload/Short Circuit Trip/Over Temperature and Low Battery Trip.Batteries should be Tubular Type for 60 min back up with Trolley/Rack and necessary cable for Inverter to Batteries Installation.
2KVA (1/1) Inverter with 3200 VAH
Please Enable Macros to View BoQ information
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.82 MB
Tendernotice_2.pdf
PDF • 23.83 MB
Tendernotice_3.pdf
PDF • 4.91 MB
BOQ_974229.xls
BOQ • 0.39 MB
Download all tender documents and submit your bid