Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹17.0 CrAdmitted-Finance | ₹17.0 Cr | L1 | Admitted-Finance |
| 2 | L2₹17.7 CrAdmitted-Finance | ₹17.7 Cr | L2 | Admitted-Finance |
| 3 | Rejected-Technical | - | - | Rejected-Technical Technically Disqualified |
| Sl No | Description | Qty | Unit | MARUTI ENTERPRISES L1 | Yella Constructions Private Limited L2 |
|---|---|---|---|---|---|
| 1.00Total Amount of BoQ 2 | |||||
| 1.01 | Amount after unconditional Rebate | 1 | Nos | 0 ₹17.0 Cr | 0 ₹17.7 Cr |
Cancellation Corrigendum
Cancellation of Tender
L1 quoted/revised rate is high
cancelled_1.pdf
Tender Value
₹13.0 Cr
EMD Value
₹26.0 L
Closing Date
27 Feb 2026, 10:30 amClosed
AGM(C)/PU - Head Ranchi
252/C, Road No 1C ,Ashok Nagar, Ranchi
Supply, Installation, Wiring Testing and Commissioning of Signalling and Telecommunication work at KDH Railway Siding of CCL
2026_RITES_266039_1
05/OT/RITES/PU-RNC/KDH-ST
Open Tender
Electrical Works
365 days
Dakra, Jharkhnad
Please refer Tender documents.
4 documents required · 4 mandatory
₹17,700
RITES LTD
₹26.0 L
5 Jun 2026
6 Feb 2026
28 Feb 2026
6 Feb 2026
27 Feb 2026
10 Feb 2026
Total Amount of BoQ 2
Amount after unconditional Rebate
Item Rate BoQ
BoQ_Ver3.0
E-tender No: 05/OT/RITES/PU-RNC/KDH-CCL/PKG-V/S&T/2025-26, Date: 06.02.2026
Name of the Bidder/ Bidding Firm / Company :
PRICE SCHEDULE (This BOQ template must not be modified/replaced by the bidder and the same should be uploaded after filling the relevent columns, else the bidder is liable to be rejected for this tender. Bidders are allowed to enter the Bidder Name and Values only )
NUMBER #
Percentage BoQ
BoQ_Ver3.0
E-tender No: 05/OT/RITES/PU-RNC/KDH-CCL/PKG-V/S&T/2025-26, Date: 06.02.2026
Name of the Bidder/ Bidding Firm / Company :
PRICE SCHEDULE - SCHEDULE-A (Supply of S&T Materials ) (This BOQ template must not be modified/replaced by the bidder and the same should be uploaded after filling the relevent columns, else the bid is liable to be rejected for this tender. Bidders are allowed to enter the Bidder Name and Values only )
NUMBER #
SCHEDULE-A (Supply of S&T Materials )
ELECTRONIC / PANEL INTERLOCKING .etc : Design, Manufacturing, Supply, and transportation of EI System(Main cabin and goomty) (HOT Stand by) as per RDSO spec. no. RDSO/SPN/192/2019 VER.2.0 or Latest ( with Latest Amendment) which includes supply of (i) Centralized Electronic Interlocking system with Distributed type IO's ( At KDH Railway Siding Yard central cabin) & Dual VDU type operation,(ii) Maintenance Terminal with Industrial Grade PC as per RDSO TAN STS/E/TAN/3007 Ver.1.0 dt.02.11.2012 or latest and 65" comercial LED monitor or latest with table etc.,(iii) Dual VDU operation with Industrial Grade PC as per Latest RDSO Spec. and 65" comercial LED monitor or latest with SM table as per approved drawing and Supply of UPS 1 KVA for operator VDU having 30 minutes backup etc,(iv) DC-DC Convertors,(v) OFC patch cords as per requirement of E.I.system,(vi)Wiring accessories required for Installation of E.I.system,(vii) Relay Racks with accessories. Note: Details brake-up of Quantity is to be submitted by agency during opening of tendering.(Rate taken from MRA)
Supply of spares@5% of EI modules (Main equipment / Module for E.I.system of the input cards/modules) as per RDSO spec. no.RDSO/SPN/192/2019 VER.2.0 or Latest ( with Latest Amendment), for KDH Railway siding Yard.(Rate taken from MRA)
Supply of active lightning arrestor of class A for building protection as per standard NFC 17-102. It shall work on early streamer emission principle and shall be made of stainless steel with a T of 60 micro second. The dimension of the device shall be 590 mm x 120 mm or more. The provision shall be there to test this device if necessary by an external tester. A non-resettable type counter shall also be supplied to count number of lightening occurrences along with required copper tape for connecting the device with earth pit. (Rate taken from ER SOR S&T 2022)
Supply and erection of a mast / high mast suitable for ESE technology based lightning protection installation, mechanically robust good corrosion and fire resistance,5 mtr. (including 2 mtr FRP) long GI/MS painted along with guying kit foundation and other accessories required for installation of mast.(Rate taken from ER SOR S&T 2022)
Supply and laying of 70 sq.mm PVC insulated flexible tinned electrolytic copper down conductor placed in a metallic / PVC protective covering wherever exposed to human intervention including saddles and all accessories as required.(Rate taken from ER SOR S&T 2022)
Supply & fixing of equipotential earth bonding unit between electrical & equipment Earthing in a explosion proof IP68 enclosure with inspection chamber for equipotential bonding during a surge.(Rate taken from ER SOR S&T 2022)
Supply & laying of 25x3 mm pure electrolytic copper tape through suitable CLASS-'B' GI pipe for loop Earthing and bonding as per site requirement.(Rate taken from ER SOR S&T 2022)
Supply & Execution of Earthing (Ring Earthing with Minimum Ten Earth Electrodes around Cabin. Building) of EI equipments along with Supply of all Required material as per RDSO/SPN/197/2008 VERSION 1.0 OR LATEST (With Latest Amendment) as per RDSO TAN no.STS/E/TAN/3006 dt.02.11.2012.,Supply of all requistes materials as per latest RDSO guide line.(Rate taken from ER SOR S&T 2022)
OUTDOOR CABLES ETC.: Cable Railway Signalling Unscreened under ground with plain annealed copper conductor, armoured PVC insulated to conform to IRS:S-63/2014 (Rev.4.0) or with latest amendments. (a) 12 core x 1.5 sq.mm.(Rate taken from Average of LOA)
Cable Railway Signalling Unscreened under ground with plain annealed copper conductor, armoured PVC insulated to conform to IRS:S-63/2014 (Rev.4.0) or with latest amendments. (b) 6 core x 1.5 sq.mm. (Rate taken from Average of LOA)
Railway underground Jelly filled 6 Quad Telecom Cable as per Spec. No. IRS:TC 30/2005 (Ver. 1) with Amd. 4 or latest amendment having 0.9 mm dia.(Rate taken from Average of LOA)
Underground, Armoures, Unscreened Railway Signalling Power Cable (Stranded 7 x 1.40) with High Conductivity Circular Copper conductor of size 2 Core x 10 Sq. mm as per specification No. IRS:S-63/2014 (Rev.4.0) & IS 1554 Pt-I with latest amendment,if any, as applicable for Power Cable.(Rate taken from Average of LOA)
Supply of OPTICAL FIBRE CABLE 24 Fibre underground Armoured as per RDSO Spec. IRS:TC-55/2006 REV - 1 Amd. 2 or Latest.(Rate taken from Average of LOA)
Supply of SDH Add/Drop MUX (STM-1) with Long Haul optics as per Tech. Spec. No.: GR/SDH-04/02 MAR 2002 with Latest amendment or Latest, equipment with 21 E1(Including Engineering Order Wire =) expandable upto 63 E1 Capacity, Simply by addition of E1 cards, fully wired, Cross Connect granularity at VC-12, VC-3 and VC-4 level, equipment with one Ethernet Interface Card. Cabinate, Power Supply Unit/Charger,Battery Bank,Sub-Racks. This also inculde Installtion,Wiring, Testing, Commissiong with Original software , with all accessories & Technical manuals etc The SDH equipment shall be TEC/RDSO approved on date of opening of technical Bid.(Rate taken from Average of LOA)
Supply & Installation of straight through joint on 6 Quad/10/20 pair cable using thermo shrink jointing kit (TSF-2), Spec. IRS-TC-77/2000/Amd 1 or latest. Note - material to be procured from RDSO's approved firm only.(Rate taken from Average of LOA)
Supply & fixing of 20 Pair CT Box, suitable for termination of 0.9mm dia 6 Quad Cable)(Rate taken from Average of LOA)
INDOOR CABLES ETC.: Supply of 1 x 10 Sq.mm. (Red/Black/Green) multi strand copper power wire as per IS:694:2010 or latest, 140 conductor each dia 0.30mm +/- 0.01 with insulation thickness of 1.0 mm and nominal conductor resistance of 1.91 ohms/km and test parameters as per RDSO Specn.No.IRS:S-76/89(Amnd.3) or latest.Colour of the wire which is required will be specified by the Engineer incharge.(Rate taken from ER SOR S&T 2022)
Supply of PVC insulated multi strand, single core copper conductor of size 3/0.75 mm as per IS 694:2010 and RDSOSpecn.No.IRS: S-76/89 (Amnd-3) or latest. Each coil should be of 100/200/500 meters length. Colour of the wire which is required will be specified by the Engineer incharge.(Rate taken from ER SOR S&T 2022)
Supply of PVC insulated multi strand, single core copper conductor of size 16/0.2 mm (0.5sqmm) as per IS 694:2010 and RDSO Specn.No.IRS: S-76/89 (Amnd-3) or latest. Each coil should be of 100/200/500 meters length. Colour of the wire which is required will be specified by the Engineer incharge.(Rate taken from ER SOR S&T 2022)
Cable indoor copper conductor plain annealed high conductivity 1100V grade PVC insulated unarmoured IRS:S-76/89 (Amd. 3) or latest amendment. (ii) 7 x 0.75 sq.mm.(Rate taken from Average of LOA)
Supply of Switch Board Cable 30 pair conductor dia 0.63 mm as per TEC Spn. No. GR/WIR-06/03 with latest amendment.(Rate taken from Average of LOA)
Supply of Indoor Cable of suitable core (1x24Cx1.0 MM dia) or similar as per Spec. No. IRS-S:76/89 (Amdt.-3) or latest.(Rate taken from Average of LOA)
DWC/GI /HDPE Pipe/cable Marker : Supply of Double Wall Corrugated (DWC)-HDPE pipe/duct of size 200 mm outer dia, & 175 mm inner dia. It includes supply of Double Wall Corrugated -HDPE pipe/duct as per RDSO Specn.No. RDSO/SPN/ 204/2011 (version 1.1) or latest and conforming to ISI Spec. No.IS:14930, Part-II. (The manufacturers, suppliers must produce valid IS license and should be certified under ISO 9000 and shall submit copy of certificate). One of the following coupling arrangements should also be supplied with each pipe as per the site requirement.1) Suitable snap fit coupler with rubber O-Ring 2) Spacers3) Tees4) Bend,5) End-capDWC pipe shall be marked at every 1 mtr length in such a way that manufacturer's name, vendor name and year of manufacture can be easily identified.Note: DWC Pipe (Full Round): 2000 Mtrs , Half Round Split DWC (1 in 2 half parts):5000 Mtrs (Rate taken from ER SOR S&T 2022)
Supply of Medium class GI pipes 100 mm dia (4.5 mm thickness) as per IS 1239 (Part 1): 2004 or Latest with socket & coupling on culverts bridges or at any other locations as decided by Site Engineer. It includes supply of all material required for fixing arrangement. Contractor will also supply flexible/corrugated HDPE pipe at the end of GI pipe to protect the cables from sharp edges and sudden bends.(Rate taken from ER SOR S&T 2022)
Supply, Transportation at site and Installation of RCC cable route marker engraved and painted on both side along the route at every 50 meter and at route diversion. The cable marker is to be fabricated as per RDSO drawing No. RDSO/Cable Laying/020, issued vide RDSO document No. RDSO/SI/G/2010 Version 1.1 dated 04.02.2014 or latest. The fixing work is to be done as per extant practice of Rly. and as per site supervisor.(Rate taken from ER SOR S&T 2022)
SIGNAL UNIT & ACCESSORIES etc : Independent Position Light Shunt Signals complete having following items: a)Shunt Signal post 90 mm dia mounting socket X 1 mtr. Long to IRS-S-6/81, IRS-S-26/64 drg. No. S 23845 (Adv). b) Shunt Signal surface base 140 mm dia to IRS-S-23844 (Adv). c) Shunt Signal unit without lenses & lamps along wiyh lamp holder unit to RDSO drg. No. SA-23840 (Adv) Alt. 1 Spec. d) Anchor bolt complete (305 mm x 50 mm x 20 mm) to Drg. No. SA-110 A/M (Rate taken from Average of LOA)
Dependent Shunt Signals complete having following items. a)Position Light Shunt Signal unit without lenses, lamps & lamps holder unit to RDSO Drg.No.SA-23840. b) OFF Set Bracket of Shunt Signal for 90 mm dia post to SA-23080 (Adv.) Alt.1.(Rate taken from Average of LOA)
Colour Light Signal (2 Aspect) as per Drg.No.SA - 23003 A/M (Adv.) & Specn. IRS-S-26/64 having following items : a) Signal Post 140 mm dia 4.5 / 3.5 mtrs. long to IRS-S-6-81 b)Signal Base C I 140 mm dia. to Drg. No. S-2011 c) CLS Ladder complete with platform and base 4.5/3.5 mtrs. long to Drg.No.SA-23153 (Adv.) Alt. d) CLS Unit 2 Apect complete to Drg.No SA - 23003 A/M to C/M (Adv.) without transformer,lenses, lamp holder and lamp. e) Anchor Bolt complete (915 x75 x 24 mm) Drg, No. 116A/H 4 No. each set. f) OFF Set Bracket of Main Signal for 140 mm dia to Drg. No. SA-23080 (Adv.) Alt.1.(Rate taken from Average of LOA)
Colour Light Signal (3 Aspect) as per Drg.No.SA - 23003 A/M (Adv.) Alt.8 & Specn. IRS-S-23/86 & 26/64 with latest amendments having following items : a) Signal Post 140 mm dia 4.5 / 3.5 mtrs. long to IRS-S-6-81 b)Signal Base C I 140 mm dia. to Drg. No. S-2011 c) CLS Ladder complete with platform and base 4.5/3.5 mtrs. long to Drg.No.SA-23153 (Adv.) Alt. d) CLS Unit 3 Apect complete to Drg.No SA - 23003 A/M to C/M (Adv.) without transformer,lenses, lamp holder and lamp. e) Anchor Bolt complete (915 x75 x 24 mm) Drg, No. 116A/H 4 No. each set. f) OFF Set Bracket of Main Signal for 140 mm dia to Drg. No. SA-23080 (Adv.) Alt.1.(Rate taken from Average of LOA)
Supply of 2 WAY AS PER RDSO DRG. NO. SA-23402 (ADV)/ ALT.2 (Rate taken from ER SOR S&T 2022)
Junction type Route Indicator direction type (4 Way) without lamp holder, lenses & lamps to IRS-S-66/84 (Amd. 1), IRS-S-23/86 with drg.No.SA-23404 (Adv.) Alt 2 or latest.(Rate taken from Average of LOA)
Calling-on-Signal unit withoiut signal lamp, lamp holder and lens arrangement and fixing arrangement having RDSO Drg.No.SA-24351 (Adv.) Alt.A.(Rate taken from Average of LOA)
MS Number plate (3mm thick) with fixing clamps of letter shall be black colour in the white back ground.Details of description shall be given by the Site Engineer.The plate & clamps shall be painted before lettering of Signal Number.(Rate taken from Average of LOA)
Enameled Number plate ( C/P ) marker of such 8" Dia (Letter in black on white back ground) with complete clamping arrangement as per RDSO Drg. No. SA -23476 (Adv).(Rate taken from Average of LOA)
Supply and Installation of Stop Board, Sighting Board on RSJ post complete with all fittings. (Rate taken from Average of LOA)
Universal Lock and Key for signal units.(Godrej Make or similar) (Rate taken from Average of LOA)
SIGNAL LED's : Supply of various LED signals (Subsidiary Signal), 110V AC retrofittable in existing CLS housing and compatible with AC LED ECR as per RDSO Specn. No.RDSO/SPN/153/2011 (Rev.4.1) or latest.- LED for Shunt Signal Aspect (Rate taken from ER SOR S&T 2022)
Supply of LED signal lamps for Main colourlight Signal, 110V AC retrofittable in existing CLS housing and compatible with AC LED ECR as per RDSO Specn. No.RDSO/SPN/ 199/2010(Rev.1) or latest - Red Aspect (Rate taken from ER SOR S&T 2022)
Supply of LED signal lamps for Main colour light Signal, 110V AC retrofittable in existing CLS housing and compatible with AC LED ECR as per RDSO Specn. No.RDSO/SPN/ 199/2010(Rev.1) or latest - Yellow Aspect (Rate taken from ER SOR S&T 2022)
Supply of LED signal lamps for Main colour light Signal, 110V AC retrofittable in existing CLS housing and compatible with AC LED ECR as per RDSO Specn. No.RDSO/SPN/ 199/2010(Rev.1) or latest - Green Aspect (Rate taken from ER SOR S&T 2022)
Supply of various LED signals (Subsidiary Signal), 110V AC retrofittable in existing CLS housing and compatible with AC LED ECR as per RDSO Specn. No.RDSO/SPN/153/2011 (Rev.4.1) or latest.- LED for Calling On Signal aspect (Rate taken from ER SOR S&T 2022)
Supply of various LED signals (Subsidiary Signal), 110V AC retrofittable in existing CLS housing and compatible with AC LED ECR as per RDSO Specn. No.RDSO/SPN/153/2011 (Rev.4.1) or latest.- LED for Route Aspect (Rate taken from ER SOR S&T 2022)
RELAYS : Q-Series LED ECR (Universal Type i.e. QECX-61), 4F/4B complete with plug board (base plate), connectors, retaining clips etc and conforming to BRS:941A STS/E/RELAYS/AC LIT LED SIGNAL/09-2002, Amdt. -1and RDSO Specn.No.IRS:S-34 & S-23 withAmdt. upto date as applicable or latest.The interlocking code for this unit shall be "ABDHK" (Rate taken from ER SOR S&T 2022)
Contactor Unit (QBCA1 Type), 24 V DC, 2F(HD)/4B or 2F(HD)2F-4B complete with plug board(base plate), connectors, retaining clips etc and conforming to BRS- 943 and RDSO Specn.No.IRS:S-34 & S-23 with amdt. upto date as applicable or latest. The interlocking code for this unit shall be "BCEJK" or "DEHJX". (Rate taken from ER SOR S&T 2022)
Q-Series Magnetically Latched Neutral Line Relay (QL1 Type), 8F/6B, 24V DC complete with plug board (base plate), connectors and retaining clips and conforming to BRS-935A and RDSO Specn.No.IRS: S-34 & S-23 or latest. The interlocking code for this unit shall be "ABCEG". (Rate taken from ER SOR S&T 2022)
Q-Series Neutral Line Relay (QN1 Type), 12F/4B, 24V DC complete with plug board (base plate), connectors and retaining clips etc and conforming to BRS- 930 and RDSO Specn.No.IRS: S-34 & S-23 with Amdt. upto date or latest. The interlocking code for this unit shall be "ABCDE". (Rate taken from ER SOR S&T 2022)
Q-Series Neutral Line Relay (QN1 Type), 8F/8B, 24V DC complete with plug board (base plate), connectors and retaining clips etc and conforming to BRS- 930 and RDSO Specn.No.IRS: S-34 & S-23 with Amdt. upto date as applicable or latest. The interlocking code for this unit shall be "ABCDF". (Rate taken from ER SOR S&T 2022)
Q-Series Line Relay (QNA1 Type), AC immunized, 12F/4B, 24 V DC along with plug board (base plate), connectors, retaining clips etc and conforming to BRS-931A and RDSO Specn.No.IRS:S-34, S-23 and S-60 with amdt. upto date as applicable or latest. The interlocking code for this unit shall be "ABDFH". (Rate taken from ER SOR S&T 2022)
Q-Series Line Relay (QNA1 Type),AC immunized, 8F/8B, 24 V DC along with plug board (base plate), connectors, retaining clips etc and conforming to BRS-931A and RDSO Specn.No.IRS:S-34, S-23 and S-60 or latest. The interlocking code for this unit shall be "ABDGH". (Rate taken from ER SOR S&T 2022)
Relay fail safe electronic time delay device with fixed timing (0 -120) seconds and conforming to RDSO Specn.No.IRS: S-61/2000 with Amnd.2 and IRS: S-34 & S-23 with Amdt. up to date or latest mounted on Q-series relay base & covered complete with connectors, retaining clip etc. The interlocking code for this unit shall be "AFGKY". (Rate taken from ER SOR S&T 2022)
Relay fail safe electronic time delay device with fixed timing (0 -60) seconds and conforming to RDSO Specn.No.IRS: S-61/2000 with Amnd.1 or latest mounted on Q-series relay base & covered complete with connectors, retaining clip etc.The interlocking code for this unit shall be "AFHKY". (Rate taken from ER SOR S&T 2022)
Fail safe electronic flasher device as per RDSO Specn.No.RDSO/SPN/173/ 2002 Amdt.2 or latest. (Rate taken from ER SOR S&T 2022)
POINT MACHINE & ACCESSORIES. : Supply of Electric Point Machine-IRS type, (AC Immunity 160V AC), Non-Trailable to operate on 110V DC complete with Lock and Detector slides, Cable Termination Box (143mm throw, thrust as applicable, Rotary locking), confirming to IRS: S 24/2002 (amdt.1) (Amdt. up to date if any) & Assy. Drg. No. RDSO-S/10910 (alt. up to date if any) & IRS: S 37/82 (amdt.3) (Amdt. up to date if any) for Motor. (Rate taken from ER SOR S&T 2022)
Supply of Point JB fitted with 18 nos. 1-way terminal block confirming to IRS-S-75/91 (AMD-2) OR LATEST, DRG. NO. SA-23741A with 3 no. of 40 mm bore G I PIPE 600 mm long as per DRG. NO. SGW/MGS/ PT4/91 fixed on hylum sheet with U channel (75x40x1500) mm for fixing ARA terminal to be procured from RDSO approved sources. (Rate taken from ER SOR S&T 2022)
Supply of Ground Connection [BG] Threaded Type for IRS type Point Machine, as per CWM/Signal Workshop/Howrah/E. Rly. drawing number, Sl.No., Description of Drawing & CWM/SW/HWH's Drawing No. mentioned below: - 1. Detector Rod (Far End) - BS/29/721 with ALT-1 Detector Rod (Near End)- BS/29/722 with ALT-1. 2. Lock Rod (Far End) - BS/29/723 with ALT-1, Lock Rod (Near End) - BS/29/724 with ALT-1. 3. Switch Extension Bracket - BS/29/725 with ALT-1. 4. Drive Rod - BS/29/726 with ALT-1 Drive Lug- BS/29/726 A with ALT-1. 5. Sleeve- BS/29/726 B with ALT-1. 6. Lug- BS/29/726 C with ALT-1. 7. Pin- BS/29/726 D with ALT-1. 8. Sketch showing the Layout arrangement- BS/29/727 with ALT-1. Amdt. and alt. up to date if any. - Turnout (Rate taken from ER SOR S&T 2022)
Point insulation Complete set as per RDSO/SPN/168/2005 for 1.Switch bracket‘D’ bracket insulation for IRS point machine - One set comprises of (a)Side plate LH to Drg.No.S-3266 - 1 No. (b)Side plate RH to Drg.No.S-3265 - 1 No. (c)Insulating bush to Drg.No.S-3199 - 4 Nos. (d) Insulating washer to Drg.No.S-8640 - 4 Nos., 2.Split-Stretcher bar 2.1 Insulation for Leading stretcher bars(BG) each set comprising of (a) Insulating plate for leading insulated stretcher bars BG as per RDSO Drg.No.T-10384 – 2 Nos. (b) Insulating bushing for leading insulated stretcher bars for BG as per RDSO Drg.No.T-10535- 4 Nos. (c) Insulating Washer for insulated stretcher bar BG as per RDSO drg.No.T-10371 – 6 Nos. 2.2 Insulation for following stretcher bars BG. Each set comprising of: (a) Insulating side plate for insulated stretcher bars BG as per RDSO Drg.No.T-10367 – 3 No. (b) Insulating bushing for insulated stretcher bars BG as per RDSO Drg.No..T-10368 – 6 Nos. (c)Insulating washer for insulated stretcher bars BG as per RDSO Drg.No.T10371 – 12 Nos& 3. Gauge tie plates (52 Kg/60Kg as per site requirement) Insulation for (BG) complete with insulating bush and washer each set comprising of: (a) Insulating plate for insulated tie plate BG as per RDSO Drg.No.T-10372-1 No. (b) Insulating bushing for insulated stretcher bar BG as per RDSO Drg.No.T10368 – 3 Nos. (c) Insulating Washer for insulated stretcher bar BG to IRS 40/84 as per RDSO drg.No.T-10371 – 6 Nos. (Rate taken from ER SOR S&T 2022)
Gauge Tie plate insulation as per RDSO/SPN/168/2005 as per RDSO drg. No: T- 10372Alt2, T- 10368, T- 10371Alt2, T-15083/88/Alt2 & T-11690/Alt2 and as per RDSO/SPN/168/2005 with latest amendments as applicable. Gauge tie plates (52 Kg/60Kg as per site requirement) Insulation for (BG) complete with insulating bush and washer each set comprising of: (a) Insulating plate for insulated tie plate BG as per RDSO Drg.No.T-10372-1 No. (b) Insulating bushing for insulated stretcher bar BG as per RDSO Drg.No.T10368 – 3 Nos. (c) Insulating Washer for insulated stretcher bar BG to IRS 40/84 as per RDSO drg.No.T-10371 – 6 Nos. (Rate taken from ER SOR S&T 2022)
POWER SUPPLY & ACCESSORIES.: Integrated Power Supply (IPS) (6 lines ) as per RDSO Specn.No. RDSO/SPN/165/2012 or latest. (Sketch No. to be provided as per site condition latter on) along with 200 AH Low Maintenance Lead Acid Battery.(Rate taken from Average of LOA)
Supply of Auto Changover LT Power Panel for CLS system as per RDSO specification no. TI/SPC/PSI/CLS/0020 with A&C slip no. 1 (8/2003) of capacity 60A, 3 supply system including 3 nos. 32A DP MCB enclosure. Design of changeover arrangement shall be got approved by the Site Engineer. All materials in this connecton shall be supplied by the contractor.(Rate taken from Average of LOA)
10 KVA single phase Diesel Generator set having 220V-AC & 50 Hz power output complete with AMF panel, fuel tank, battery to start, sound proof acoustic enclosure & other accessories. DG set should of reputed manufacturer (Kirloskeror or similar),certificate of which is to be submitted.(Rate taken from Average of LOA)
A set of 'B' &'C' class surge protection system consisting of lightning current arrestors two nos.of Class 'B' for connecting between line & neutral and Neutral & Earth & Class 'C' between line & neutral with in built thermal isolating device suitable for single phase power supply in TT network, housed in a polycarbonate transparent box with IP 65 protection, all conforming to RDSO Spec no. RDSO/SPN/144/2004 or latest .(Rate taken from Average of LOA)
Distilled water plant with stainless steel container capable of delivering 3.5 to 4.5 lits. Per hour pure distilled water including 10 liters polythene jar of good quality to be inspected by the consignee before supply of the distilled water plant. One of the plants to be installed at Gankar stn. Cabin & the other at Cement siding panel cabin.(Rate taken from Average of LOA)
LOCATION BOX / RELAY RACK / CTR & ACCESSORIES.: Supply of full size apparatus case (GKP type) (as per DRAWING NO. SW SK NO. 4/90 && other applicable GKP SW Drawing). This includes supply of location box (GKP type) with 'E' type lock & key, fitted on location door on both side, E Type lock (ward No will be specified by Site Engineer) as per RDSO Drg. No. SA 3376 and Key to Drg. No. 3377 as per RDSO drawing No. RDSO/S-11500.NOTE - One key and one handle with each four Apparatus cases to be supplied. (Rate taken from ER SOR S&T 2022)
Q series Relay rack assembly complete with fixtures & all accessories like ladder, runway for indoor cable wires, and 96 way tag blocks (6 nos. per rack) alongwith mounting arrangement etc. BRS 930, 931A, and STS/E/Relays/UEA(PI) as per drawing RITES/SIG/GEN/006A-07.(Rate taken from Average of LOA)
Main cable termination rack complete assembly with square bars for mounting 2 way disconnect terminals, ARA terminals, 8 Way terminal strips, screws, nuts & bolts, scaffolding ladders for cable wires alongwith mounting arrangements etc.as per RITES Drg. No. RITES/S&T/SIG/GEN/052A-09. (Rate taken from Average of LOA)
Supply of PBT ARA terminal as per IRS SPECN.NO. IRS: S-75-2006(REV-2) OR LATEST. Material to be procured from RDSO's approved firm.- 1 WAY,DRG.NO.23741A, ALT-4. (Rate taken from ER SOR S&T 2022)
Supply of PBT ARA terminal as per IRS SPECN.NO. IRS: S-75-2006(REV-2) OR LATEST. Material to be procured from RDSO's approved firm.- 6 WAY, DRG.NO.23756,ALT-3. (Rate taken from ER SOR S&T 2022)
Supply of 4 conductor disconnect Terminal Block for test and measurement 0.08 Sq. MM - 2.5 Sq. MM 600v 15A center marking with test slot for test plug Dia 2 MM/0.79 Inches and dia 2.3/0.091 inches.carrier rail DIN 35; front entry, cage clam connection:Grey WAGO part No. 280-870 or similer along with suitsble quantity of markers. (Rate taken from Average of LOA)
Supply of End and Intermediate Plate:2.5 MM.0.098 Inches thick Grey part No. WAGO 280-374 or similar (Rate taken from Average of LOA)
Supply of Steel Carrier Rail 35X7.5MM; 1MMX0.039 Inches; thick unslotted similar to WAGO part No. 210-229/PW110000 (Rate taken from Average of LOA)
Supply of Screwless End Post ; 10MM/0.394 Inches WIDE; Carrier Rail DIN 35, GREY SIMILAR TO wago PART No. 249-117. (Rate taken from Average of LOA)
Fuse block made of PBT as per RDSO specn. No. IRS:S-75/2006 (Rev.2) & drg.No. SA-23748 (Alt. 4). Non deteriorating fuse links knife edge type with suitable fuse carrier and box. (Rate taken from Average of LOA)
Fuse, non-deteriorating(2A/6A/10A/16A) type, cylindrical(IRS-S-78/92) [quantity as per site requirement]. Note : 2A - 150 Nos, 6A -30 Nos,10A -30 Nos , 16A = 50 Nos (Rate taken from ER SOR S&T 2022)
Negative bus bar 20mm x 5 mm thick made of Copper bar with OBA Brass screw & washers, all should be Nickel plated. (Rate taken from Average of LOA)
EARTH PIPE & ACCESSORIES.: Supply of Earth Electrode Mild Steel Galvanized,Light Class,IS:1239(part-I)-1979.Earth electrode pipe should be with 3mm thick,50 mm dia and perforated (stagerred),5mm dia holes,2 nos per 305 mm length with clamp of MS flat (Galvanized)of size 35mm x 6 mm (spec.no.226 STD).Earth pipe should include C.I.threaded cap.Materials to be procured and designed as per CSTE/ER's drg.no.S&T-1/2007. (Rate taken from ER SOR S&T 2022)
Supply of MS Flat (Spec.no.226 STD) of size 35mm X 6mm with length of 5 Mtr. With hole of 12 mm dia. at both end as per CSTE/ER's Drg.no.S&T-1/2007. (Rate taken from ER SOR S&T 2022)
MAGNETO PHONE/VHF etc. Supply and Installation of Desk type Electronic Magneto Telephone as per RDSO Spec. No. IRS TC:79/2000 (Amendment-2) or latest. (Rate taken from Average of LOA)
Supply of 25 Watt VHF synthesised trans receiver set, synthesised in frequency band 136 MHz to 174 MHz (full band), with DTMF microphone and cords, with GP antenna, 30 m of feeder cable and suitable BNC connectors, with 3m of power cord and 12V/13.5V 10Amp/15Amp power supply suitable for 25W VHF set, as per RDSO spec. RDSO/SPN/TC/107/2018, Rev. 0.0 Amndt 1 or latest. (Rate taken from ER SOR S&T 2022)
Supply, fixing and wiring of surge protection device in attachment plug module with replaceable surge protection for coaxial signal, interfaces N-connector plug/socket installed as surge protection between antenna and 25 W VHF sets, make- Phoenix Contact model CN-UB-280DC-SB-2818148 or similar as per specifications. this includes mounting plate and reserve gas filled surge arrestor (one no.) with all required connectors/clamp for commissioning of SPD at site. (Rate taken from ER SOR S&T 2022)
5 Watt VHF Portable Synthesized Trans Receiver GP-328 (VHF Walkie Talkie set) Motorola or similar make with Lithium Battery with single unit Rapid Battery charger (for GP-328/338/329/339 or similar). Complete with all accessories & ( Including DOT levying and License Fee) (Rate taken from Average of LOA)
Supply of Universal 2/4 wire way side DTMF control telephone as per RDSO spec. no. IRS: TC:82: 2005 (with Amdt. 3) or latest. (Rate taken from ER SOR S&T 2022)
Supply of power supply unit for telecom installation at way side station suitable to operate max 6 equipments of DTMF type (12V/7AH) battery with suitable battery charger) as per RDSO spec. No. IRS: TC-72-97 or latest. (Rate taken from ER SOR S&T 2022)
Supply of 4W way station DTMF equipment as per RDSO spec. no IRS-TC/60/93 or latest ( with 4 wire telephone as per spec. No IRS-TC-38/97 or latest. Make- Bentron, Epsilon or similar and supply of 12V/7AH power supply unit for control phone. (Rate taken from ER SOR S&T 2022)
Supply of OFC Termination box as per TEC Spec No.TEC/GR/TX/FTB-02/02/APR-2010 with latest amendment including all miscellaneous & consumable for fibre splicing. It should have the capacity to terminate 02 No. 24 OFC cable through separate entry holes & to take out & terminate 6 or 24 pigtails through separate exit holes. Make: JT Optics/Raychem/Aras Telecom/equivalent. (Rate taken from ER SOR S&T 2022)
UFSBI / SSDAC / MSDAC etc. Supply, Transportation, Installation, Testing and Commissioning of Multi Section Digital Axle Counter (MSDAC) for mentioned detection Point by the purchaser & Track Section as per SIP uploaded with the tender, complete with all accessories, cable required with each track device & Card viz., Axle Detectors, Track Side Electronics/DAC field units, Central Evaluator (Central Evaluator unit should be housed in a pre-fabricated Rack to be supplied along with the system), Reset unit, Relay unit, Event logger & Diagnostic terminals etc. required for different Detection Points & Track Sections as per RDSO Specification No. RDSO/SPN/176/2013, Ver.3 or latest as per Annexure-070801(A, B & C.) (Rate taken from ER SOR S&T 2022)
Supply, Installation testing & commissioning of High Availability Single Section digital axle counters (HASSDAC) with Dual sensor system as per RDSO/SPN/177/2012 version 3 or latest. This includes the supply of High frequency web mounting type Tx coil/Rx coil, VR/PR Box duly wired, Vital relays, PR Relays, Clamp with deflector plates & hardware, Dual display reset box with auto resetting facility, Surge voltage protection devices and filter card to be mounted on din rail etc. as per OEM for complete installation & testing & commissioning of (HASSDAC) system NOTE: One set of HASSDAC system will include equipment required to monitor One Up line or One Dn line of a full Block Section between two stations. This include fixing of device, relays, wiring, lacing /dressing, cable termination with lug eyelet, drilling holes in rails, Installation of track devices and make it functional along with existing UFSBI/block instrument. Material required other then supply item of HASSDAC shall be arranged by contactor to make it functional. (Rate taken from ER SOR S&T 2022)
Supply of Tools Kit for High frequency Digital Axle Counter Multi section. This includes Supply of Service test panel including meter for test of track equipment, tools for mounting and adjustment of track equipment and standard jig for drilling holes in rail. It should be as per Principal manufacturers (OEM) recommended list adequate for installation, day to day maintenance, and adjustment of indoor and outdoor gears. This shall also include kit for making and drilling of holes on rail. Note: (1) this also includes supply of cross talk measuring set as per RDSO SPEC. TC 45-88 or latest, dB meter for measuring attenuation loss & 500v insulation tester, dummy wheel, torque wrench (2) multimeter should be pure sine wave digital multimeter make Fluke Model 287/ Rishabh Model 28s. Each measuring tools &equipments to be supplied with OEM'S test certificate/ guarantee certificate (as applicable). Detail Specification of tools kit are provided in tender document. (Rate taken from ER SOR S&T 2022)
Supply of Block Panel BPAC (Block proving with digital Axle counter) using UFSBI complete set as per IRS: S-105/2012 Ver.0 with latest amendment & Manufacturing specification for Double line operation. NOTE: One set will include equipments required for one complete double line Block Section except DAC.This includes Relay, Relay Base, Retaining clip & connectors to be supplied by the contractor alongwith the UFSBI. (Rate taken from ER SOR S&T 2022)
PA SYSTEM Supply , installation commissioning of 250 watt Amplifier Make Ahuja model SSA 250M or Similar. (Rate taken from ER SOR S&T 2022)
Supply of high fidelity PA horn speaker IP-65 rated model AMH-402T, make Ahuja or similar.(Rate taken from ER SOR S&T 2022)
Supply of PVC insulated Copper Wire 1.5 sq. mm. (Rate taken from Average of LOA)
Supply of Microphone, Model PRO-2200 SC Ahuja make or superior. (Rate taken from Average of LOA)
Supply of Mike Stand Model ATS - 5, Ahuja make or superior. (Rate taken from Average of LOA)
Supply of PA wall mounted speaker, model WS-664T, Ahuja Make or superior. (Rate taken from Average of LOA)
FURNITURE Supply of Office Chair make Godrej CH-7B or similar of reputed brand. .(Rate taken from ER SOR S&T 2022)
Supply of Office table with laminated top with three drawers on left hand side and one locker on the right hand side. Olive brown with duplicate keys. Make: Godrej Model T-9 (136.5 cmX68cmX 75cm)or Similar of reputed brand. .(Rate taken from ER SOR S&T 2022)
Supply of Steel Plain Almirah with 4 adjustable slaves Size: 1980mm height, 915 mm width and 485 mm depth. Make: Godrej Storewel Plain Large or Similar of reputed brand .(Rate taken from ER SOR S&T 2022)
Supply of Panel cum Block Instrument table complete as per approved drawing. It includes any modification to it if required by Site Engineer-. .(Rate taken from ER SOR S&T 2022)
TOOLS and PLANTS. Tools and Plants & Measuring Instruments as per the following List: ;- i) Cutting Plier Insulated 200 mm = 1 no. ii) Nose plier round Insulated 150mm=1 no. iii)Screw Driver Adjustable & common handle = 1 no . iv)Socket Spanner 15 to 19 mm socket plus 5,Accessories = 1 Set.. v) Spanner Double Ended 32X33 mm = 1 no. vi) Hammer Ball Pein 1.5 lbs. = 1 no. vii) Electric Soldering Iron 230 V, 50 W Make Philips, Soldron or similar = 1no. viii) Wire Cutter Insulat ed = 1 no. ix)Wrench Adjustable SF 305 mm = 1no. x) Spanner Set ( Consisting of 8 nos.) double ended (Chromium plated) = 1no. xi) Spanner double ended 24X25mm = 1 no. xii)Earth Megger ( 0-500 )Volts ( Motwani/Shanti make or similar) = 1 no. xiii) Tool box made of sheet metal iron to carry all the tools in the list = 1no. xiv) Emergency lighting aid (BPL or similar) = 1 no. xv) 3-Cell torch light nickel plated brass body (Eveready or similar). xvi) Digital Multimeter = 1 no. with the following range: (a) 0-1000V AC / DC; (b) 0-10 Amps.; (c) 0-1000 ohms; (d) 3-1/2 digits. The Mutimeter shall be supplied with rest probes, leather cover, battery and is of reputed make like Philips/MECO/ RISHAV/ MOTWANE. xvii) Box Spanner D / E 8 X 10 mm = 1 no. xviii) Box Spanner D / E 10 X 12 mm = 1 no.xix) True RMS Digital Multimeter of 4-1/2 digits capable of measuring (a) 10Amps AC/DC cur-rent (b) True RMS voltage with bandwidth of 5 KHz similar to ESCORTS 97 or FLUKE = 1no. xx) Digital Clamp Meter (Metravi/Rishabh/Motwane or similar make) = 1no. (Rate taken from Average of LOA)
DATALOGGER : Data Logger System consisting of the following:- a) Supply of Net worked Data logger for monitoring relays,complete with processor module to monitor 1536 digital inputs and 64 analog inputs as per RDSO Spec. No. IRS-S-99/2006 (Amdt. 3) or latest.including CMU,power supply of adequate capacity,battery,modems and fault diagonastic software for failure analysis,president rack of suitable size.It should have port for E1 connectivity for sending data to control office. b) Supply of one no. composite computer-printer table,UPS and Printer,and one no.operator chair. c) In case of EI installation,this datalogger is for logging events outside of EI and full digital input must be supplied.Interface connection with EI is part of EI.This datalogger will transfer its own data along with EI data to Control Monitoring Unit by using EI connectivity.d) Supply of interconnecting cable between cotacts & datalogger,this can be either 60/40 indoor cable or jumper wires as per IRS: S-76/89 or latest RDSO spec.as per requirement.e) Supply of inter-connecting cable between CMU and Datalogger. (Rate taken from Average of LOA)
MISC . Supply of electronic Cable route tracer/locator with underground cable and pipe locating receiver and cable avoidance tool that provide location of armouredOFC ,signalling and telecom , power cable etc. make : C Scope Stanley/3M Dynatel , model: DXL-4 DBG /2273M-iD 30 or Similar/ superior. Item to be supplied after successful demonstration and Approvalby client. (Rate taken from ER SOR S&T 2022)
Supply Wiring, installation, testing and commissioning of Earth Leakage Detector (12 nos. channel) as per RDSO specification no. RDSO/SPN/256/2002 or latest having 6-digit counter, 12 Channel bus bar voltage of 110V AC/DC and/or 60V/24V/12V DC measurement in 19" sub rack along with insulation resistance meter, remote indication & buzzer in ASM room at station. The tenderer should submit three years’ warranty certificate along with supply of material. This includes supply of fuse terminal strip for incoming power supply wires. On job training at site will be given by OEM engineer for installation and maintenance of ELD. (Rate taken from ER SOR S&T 2022)
FIRE ALARM SYSTEM Supply, Installation, Testing & Commissioning of Microprocessor based Networkable Analogue Addressable up to 64 nodes 1 Loop Fire Alarm Control panel with LCD display, the panel should be equipped with sufficient No. of loop as per RDSO Specification No. RDSO/SPN/217/2018 ver 2.0 or latest. Each loop shall have capacity of 127 analogue addressable devices in 1 loop, the panel shall have sufficient No. of programmable relay control for controlling AHU's, pressurisation fans, ventilation fans at fire pump room, monitoring of fire sprinkler & sealed lead acid batteries sufficient for 24 Hours normal working & then capable of operating the system for 24 Hours during Emergency conditions as required. The panel shall have provision of connectivity of BACNET/ MODBUS/ LONWOK/TCP-IP. The panel shall have dedicated RS232 serial port for direct PC or MODEM connection, optional remote printer as per RDSO Specification No. RDSO/SPN/217/2018 ver 2.0 or latest . (Rate taken from ER SOR S&T 2022)
Supply, Installation, Testing & Commissioning of Probe type bimetallic Heat Sensor/Fixed cum ROR 90 degree with required module to be communicated with main fire Alarm Panel as per RDSO Specification No. RDSO/ SPN/ 217/ 2021 ver 3.0 or latest (Rate taken from ER SOR S&T 2022)
Supply, Installation, Testing & Commissioning of intelligent Analogue Addressable Multi-Sensor type smoke detector with inbuilt fault isolator and integral response indicator with 360 degree viewing angle. Detector shall communicate 3 danger levels for differentiated alarm activation and high tolerance to dust, dirt, temperature fluctuations and air current. Detector should have unique address for communication and assigned through panel with mounting base as required with the protection category of IP 40. All items as per RDSO Specification No. RDSO/ SPN/ 217/ 2021 ver 3.0 or latest. (Rate taken from ER SOR S&T 2022)
Supply, Installation, Testing & Commissioning of Analogue Addressable Manual Call Point with integral short circuit isolator, Analogue addressable protocol having status LED for alarming & standby mode, electronically addressed) as per RDSO Specification No. RDSO/ SPN/ 217/ 2021 ver 3.0 or latest.(Rate taken from ER SOR S&T 2022)
Supply, Installation, Testing & Commissioning of UV/IR Type Flame detector with required module to communicate on main fire alarm panel as per RDSO Specification No. RDSO/ SPN/ 217/ 2021 ver 3.0 or latest. (Rate taken from ER SOR S&T 2022)
Supply, Installation, Testing & Commissioning of Linear Heat Sensing (LHS) cable as per RDSO Specification No. RDSO/ SPN/ 217/ 2021 ver 3.0 or latest. (Rate taken from ER SOR S&T 2022)
Supply, Installation, Testing & Commissioning of LHS interface module as per RDSO Specification No. RDSO/ SPN/ 217/ 2021 ver. 3.0 or latest.(Rate taken from ER SOR S&T 2022)
Supply, Installation, Testing & Commissioning of Air Sampling Type detector shall use LASER type. This type of detector shall use piping or tubing distribution network that shall run from the detector to the area as to be protected. It should be supplied with required module & Power supply unit complete as a system with all accessories like pipes, Sampling points etc. as per RDSO Specification No. RDSO/ SPN/ 217/ 2021 ver 3.0 or latest (Rate taken from ER SOR S&T 2022)
Supply, Installation, Testing & Commissioning of intelligent Addressable Loop Powered Sounder cum beacon with base inbuilt fault isolator with protection category of IP42 and duly approved as per RDSO Specification No. RDSO/ SPN/ 217/ 2021 ver 3.0 or latest. (Rate taken from ER SOR S&T 2022)
Supply, Installation, Testing & Commissioning of FRLS unarmoured/armoured cable(2Cx1.5 sq.mm) with all accessories for connection of all Fire Alarm devices as per RDSO Specification No. RDSO/ SPN/ 217/ 2021 ver 3.0 or latest (Rate taken from ER SOR S&T 2022)
Supply of CO2 type fire extinguisher capacity 4.5 Kg capacity ISI Mark IS: 15683 operating temperature (-30)° to (50)° for class 13 B type of fire with 1 mtr. Hose pipe fitted with PVC bend horn complete in all respect.(Rate taken from ER SOR S&T 2022)
Solar power system for 110V, 300AH/400AH battery bank with load as IPS system. Each solar panel containing the following items (Rate taken from ER SOR S&T 2022) (a)Supply of solar photovoltaic module as per IRS: S 84/92 with latest Amdt. Or latest,12 V 80W peak,72 nos. in each set, (9 series x 8 parallel). Material to be procured from RDSO PART I approved manufacturer only. If, PART I source is not available procurement to be made from RDSO's approved part ii manufacturer. -Inspection-RDSO (b)Supply of charge controller of 110V,60A compatible with solar panel installed with digital meter. The charge controller should have overvoltage protection and low voltage protection, blocking diode fitted in the charge controller 1 no. In each set. The charge controller should have the mode of float/boost charging facility-Inspection-Consignee (C)Supply of junction box fitted with MOV etc. 1 no. In each set. -Inspection-Consignee (d)supply of mounting frame of angle iron MS galvanised of adequate strength for solar panel as with suitable tilting arrangement to be fixed on roof top of building (4 modules and 5 modules structure).1 no. In each set. -Inspection-Consignee (e)Supply of power cables with conduit pipes and grouting bolts/hardware. This includes 1 x 2.5 sq mm, 2x2.5 sq mm cable for series and parallel connection of modules, 2x10 sq mm cable between junction, charge controller.-Inspection-Consignee (f)Supply of Earthing kit(6 nos.)-Inspection-Consignee (g)Installation kit.1no-Inspection-Consignee.
Supply and Installation of RFID based Electronic /Pipe marker for S&T Cable with programmable memory for saving the user specific data which can be buried up to depth of 1.5 Meter. Make Stanley/3M or Similar. (Rate taken from ER SOR S&T 2022)
Supply of RFID marker locator with built in GPS module/system, 1.5 M depth range. Make Stanley/3M or Similar (Rate taken from ER SOR S&T 2022)
Supply of Automatic Media changeover system of Modem working on redundant channel for data transmission on OFC/Quad/ microwave radio, for seamless operation of UFSBI over multiple media.(Rate taken from ER SOR S&T 2022)
Percentage BoQ
BoQ_Ver3.0
E-tender No: 05/OT/RITES/PU-RNC/KDH-CCL/PKG-V/S&T/2025-26, Date: 06.02.2026
Name of the Bidder/ Bidding Firm / Company :
PRICE SCHEDULE - SCHEDULE -B (Execution of S&T work ) (This BOQ template must not be modified/replaced by the bidder and the same should be uploaded after filling the relevent columns, else the bid is liable to be rejected for this tender. Bidders are allowed to enter the Bidder Name and Values only )
NUMBER #
SCHEDULE - B (Execution of S&T work )
Excavation of cable trench as per cable route plan, 1.2 Mtr. deep and of 0.3 Mtr. to 0.6 Mtr. wide at bottom without brick as per DRG. NO. S&T/C-40(NKG), SK/4/95/NKG, SK/8/95/NKG. or latest alongside the track in all kinds of soil, conforming to distances as per cable route plan and refilling. This work includes clearing of route from bushes etc. The work shall be done as per instructions of Site Engineer . Note:-(a) for all trenches from distant signal to home signal and to relay room, the minimum headway above the uppermost cable in the trench should be 600mm. If due to a large no. Of cables headway is not available, 4" of 1:2:4 concreting should be done. Note:-(b-1) payment will be made as per actual work done on pro-rata basis, if required depth is not available at site. (b-2) if the depth of trench is not uniform in a span of 100 mtr. Or shorter lengths if site condition demands along the cable run, minimum depth will be taken for that particular stretch for payment.(Rate taken from ER SOR S&T 2022)
Excavation of cable trench as per cable route plan, 1 Mtr. deep and of 0.3 Mtr. to 0.6 Mtr. wide at bottom as per RDSO sketch No. SDO/CABLE LAYING/003 or latest alongside the track in hard soil, conforming to distances as per cable route plan and refilling. This work includes clearing of route from bushes etc., covering of cable laid in trench by loose soil for a layer of 50mm thickness approximately before covering by bricks. The work shall be done as per the extant practice on Eastern Railway and instructions of Railway Engineer at site. Note:-(a)for all trenches from distant signal to home signal and to relay room, the minimum headway above the uppermost cable in the trench should be 600mm. If due to a large no. of cables headway is not available, 4" of 1:2:4 concreting should be done. Note:-(b-1) payment will be made as per actual work done on pro-rata basis, if required depth is not available at site. (b-2) if the depth of trench is not uniform in a span of 100 mtr. Or shorter lengths if site condition demands along the cable run, minimum depth will be taken for that particular stretch for payment..(Rate taken from ER SOR S&T 2022)
Digging of cable trench 0.3 Mtrs. Deep and 0.3 Mtrs. Wide on Platform / Road / Hard rocky area. Refilling with earth leveling of trenches & restoring the original surface of trenches. The sharp edges will be smoothened out in bottom of the chase and will be leveled properly. In hard rocky ground area , cables will be laid normally on layer of shifted earth of 0.05 mtrs thickness previously deposited at bottom of the trench and cables will be covered with layer of sand or shifted earth of 0.1 mtr thickness. In case sharp edges of rocky ground cannot be protected from shifted earth then GI/ CI /PVC /DWC/ HDPE pipes will be used, if numbers of cables is small. In case number of cables are large RCC duct will be used. In isolated cases, it can be given smooth surface by using either masonry bricks or cement concrete. A row of bricks shall then be placed length wise on the top and jointed with cement mortar and layer of concrete with cement plaster shall be provided on top of the same. Note: This item in hard rocky area will be operated only where normal depth i.e.1.2 mtr is not possible and it will be decided by site engineer/unit officer incharge of work..(Rate taken from ER SOR S&T 2022)
Laying & Fixing of Medium class GI pipes 50/100 mm dia (4.5 mm thickness) as per IS 1239 (Part 1): 2004 with socket & coupling on culverts bridges or at any other locations as decided by Site Engineer. It includes installation of all material required for fixing arrangement. Contractor will install flexible/corrugated HDPE pipe at the end of GI pipe along with any masonry work(if required) to protect the cables from sharp edges and sudden bends..(Rate taken from ER SOR S&T 2022)
Placing of DWC HDPE/RCC/GI pipes along with collars in trenches at places near track and road, crossings, platform cuttings etc..(Rate taken from ER SOR S&T 2022)
Transportation , laying & installation of split double wall corrugated pipe in the cable trench parallel to the track, as per Site Engineer & cable route plan.(Rate taken from Average of LOA)
Laying of S&T Cables of various cores/ pairs/ quads in trenches/ GI pipes/ RCC pipes/ DWC pipes/ Trunking. This also includes laying of cables in track crossings & road crossings. Item includes provision of labels of coloured plastic adhesive tapes or any other identifiable material on each cable to give the cable number at each Gantry Post/hectometre post.(Cables will be meggered before and after its laying by contractor under supervision of Site engineer and he will submit the meggering report of each testing). Length of the cable laid includes the length of the cable coiled for termination purposes.(Rate taken from ER SOR S&T 2022)
Repair of pucca roads to original state in level crossing area after cable laying.(Rate taken from ER SOR S&T 2022)
Digging of trench 1.2 Mtrs. deep from rail flange/ road level and 0.3 Mtrs to 0.6 Mtrs wide and back filling after placing of DWC/ RCC/GI pipe. (Placing of DWC/RCC/GI pipe covered separately). The ballast disturbed be screened and dressed as required by Engineer-in-charge or his representatives and road tarred immediately. For track crossing, RDSO sketch No. SDO/CABLE LAYING/009 or latest and for Road Crossing, RDSO sketch No. SDO/CABLE LAYING/010 or latest are to be followed.(Rate taken from ER SOR S&T 2022)
Excavation of OFC pit for cable jointing of size 1.5m x 1.5m x 1.2 m for all type of soils. The section. Back filling the pit and ramming after jointing. Provision of brick walling the four walls and bottom of pit with RCC slab, back filling with earth and ramming as per drawing. N.B. all the materials including cement required for the above will be supplied by the Agency.(Rate taken from ER SOR S&T 2022)
Cement concrete work for miscellaneous items in the ratio 1: 3: 6. Item includes excavation, ramming, curing and plastering with cement & sand mixture (aggregate not exceeding 3.8 cm.) (Aggregate cement & sand to be supplied by the contractor). Wherever depth of 0.5 m cable trench is not feasible, cable shall be protected as :- Preparation of cement mixture 1:3:6 with contractor's own materials and spreading cement concrete mixture layer of 100 mm thick over the already laid cables in the excavated trench.(Rate taken from ER SOR S&T 2022)
Removal of Rail (13 mtrs.) in the way of cable route. In case of panel (39 Mtrs. Each) will be consider as three rails for payment purpose. (Rate taken from ER SOR S&T 2022)
Removal of PRC Sleeper in the way of cable route. (Rate taken from ER SOR S&T 2022)
Location and Signal foundation Excavation of pit, casting & plastering of concrete foundation for Colour Light Signal as per drg.No.RITES/PU-RNC/2025/03. This includes : Supply of cement, sand, stone chip 1'' size & mixing in the ratio 1:3:6.and supply of foundation bolts of sizes 24mm x 915 to suit drg.SA-116 A/M. This includes:a) Erection of 2/3/4 Aspect Colour Light Signals. b) Erection of surface base, signal post, signal unit, ladder with guard & platform, Calling on Signal, Dependent Shunt Signal on Off-set bracket, Jn. Type Route Indicator etc. as per SIP. This includes Fixing of Number Plates with complete fittings & its lettering and numbering, Fixing of LED lamps and wiring of Signal & Testing as per instruction of site Engineer. The gap between Signal Pole & surface base to be filled up to avoid tilting. (Rate taken from Average of LOA)
Excavation of pit, casting & plastering of concrete foundation for Shunt Signal. as per drg.No.RITES/PU-RNC/2025/04 This includes : Supply of cement, sand, stone chip 1'' & mixing in the ratio 1:3:6.and foundation bolts of sizes 20 mmx 305 mm to drg.SA-110 A/M This includes:(a) Erection & wiring of Shunt Signals.(b) Erection of surface base, signal post, signal unit. (Rate taken from Average of LOA)
Erection of Jn. Type Route Indicator with 6 way drum, with 1/2/3/4/5/6 way arm. This includes a) Fixing of LED lamps b) Wiring & testing (Rate taken from Average of LOA)
Excavation of pit, casting & plastering of concrete foundations for full size location box as per Drg. No. RITES/PU-RNC/2025/01 This includes: Supply of Foundation Bolts and nuts, cement, sand, stone chip & mixing in the ratio 1:3:6.This includes:a) Supply of cement of approved brand, sand, stone chip 1'' size & mixing in the ratio 1:3:6.b) Supply of 4 Nos. foundation bolts as per Drg.No.SA-112A with Nuts & MS washer. (Rate taken from Average of LOA)
Erection of Steel Apparatus Case on foundation including fixing of miniture `E' type lock & locking arrangement, wiring, testing & commissioning as per approved wiring diagram. This includes : i) Supply & fixing of hylum sheet, resin bonded 25 mm thick grade P3 in standard size of 1.22 x 1.22 mtrs. for shelves. ii) Termination of cables with number. embossed ferrules, bunching of cables with PVC tape button including supply of ferrules, tape, cable fixing clamps etc.(iii) Filling up pit inside the Apparatus Case by sand and plastering of the foundation.(iv) Fixing of terminals, fuse blocks, N.D. fuses, etc. as per approved wiring diagrams. v) Supply & Fixing of Six way terminal block on hylum strips of size 225mm x 57mm x 6mm reinforced with 25mm M.S. Angle inside Apparatus case for wiring descriptional of Terminal and fuse as per approved wiring diagram.(Rate taken from Average of LOA)
Point machine Installation, wiring, testing and commissioning of 110 V, DC Point Machine as per Specifications and approved wiring diagrams. This includes : Fixing of point machines on MS plate fixed on wooden/concrete sleepers complete with fixing of anti theft covers, junction boxes , ground connection. Fixing of insulation for gauge tie plate and crossing plate for 52/60 KG Points & Crossings.Fixing of insulation for switch extension pieces (D /P bracket) and leading and following stretcher bars.Termination of cable & Wiring from the cable termination box to the point machine as per specifications. All smithy works. Supply of MS plates, flat, angle, bolts, nuts, pins as required. Preliminary adjustment for operation of Points by Crank Handle Testing the point machines from the point of operation including testing with 5 mm Test Piece.(Rate taken from Average of LOA)
Relay Rack and CTR erection Erection of Cable Termination Rack. This includes supply of nuts & bolts, Supply and fixing of MS wiring ladder from CTR to Relay Rack,Supply & fixing of Hylam sheet (725 mm x 57mm x 3mm) for fixing terminal block & writing terminal description, termination of Signalling cable with number embossed ferrule, bunching of cable with PVC tape and button, earthing of the CTR & cable armour and soldering, MS clamps and cement for masonary works,filling up the cable pit by sand.(Rate taken from Average of LOA)
Installation of Q series Relay Rack assembly with (3/4 X 9'') anchor bolts with one nut and one washer per bolt. fixing of MS ladders as per requirement, fixing of relay base plates,relays,fuses, bus bar, terminals, terminal blocks, fixing of Hylam sheet 725mmx57mmx3mm for wiriting rilay & terminal descriptions. (Rate taken from Average of LOA)
Wiring of Relays complete in Relay Rack and Rack to Rack ,Tag Block & CTR as per approved wiring diagram. Crimping of wires with relay connectors and soldering after testing, bunching of wires with PVC tape & button. Alteration of wiring of the existing relay rack, if any, to be carried out. (Rate taken from Average of LOA)
Markers and LED fittings Installation of "C/P" marker on Signals as per standard practice at site. The necessary materials like clamp,nuts & bolts etc. for the installation of these marker shall be supplied by contractor. This shall be got done under supervision of Site Engineer.(Rate taken from Average of LOA)
Installation of RED/YELLOW/GREEN Main Signal LED aspect, current regulator and health monitoring unit(Rate taken from Average of LOA)
Installation of Route Indicator LED/ Shunt LED aspect with built in current regulator (Rate taken from Average of LOA)
Installation of Calling -on LED aspect with built in current regulator(Rate taken from Average of LOA)
Painting and Lettering Painting of two coats of synthetic enamel paint over one coat of primer on the following after scraping & cleaning surface wherever necessary with contractor's own supply of paints. Wherever required contractor shall apply coating of epoxy paint also as per instructions of site-in-charge. Epoxy paint will be supplied by agency. NOTE: - The paint and primer should be from Asian Paints/ Nerolac / Dulux / Berger. The primer / enamel paints (Aluminum synthetic, black enamel, brilliant white and yellow) will be as per (IS 5660 of 1970) / (IS 2932 of 1974) of Apparatus Case Full Size. (Outside & inside).(Rate taken from ER SOR S&T 2022)
Painting two coats of enamel paint over one coat of Red oxide primer on the following items after scrapping and cleaning of the surface wherever necessary. Primer & paints both of approved quality (i.e The paint and primer should be from Asian Paints/ Nerolac / Dulux / Berger.The primer / enamel paints (Aluminum synthetic, black enamel, brilliant white and yellow) will be as per (IS 5660 of 1970) / (IS 2932 of 1974) ) are to be supplied by Contractor. This includes: (i) Main Signal post with signal unit, Jn. surface complete with Route indicator fittings as per Rlys. standard practice. This includes dependent, Indipendent shunt Signals also as enclosed above. (Rate taken from Average of LOA)
Painting two coats of enamel paint over one coat of Red oxide primer on the following items after scrapping and cleaning of the surface wherever necessary. Primer & paints both of approved quality (i.e The paint and primer should be from Asian Paints/ Nerolac / Dulux / Berger.The primer / enamel paints (Aluminum synthetic, black enamel, brilliant white and yellow) will be as per (IS 5660 of 1970) / (IS 2932 of 1974) ) are to be supplied by Contractor. This includes: (i) Point Machine with ground connections complete (point machine with black enamel only outside & ground connection with Red oxide). (Rate taken from Average of LOA)
Painting two coats of enamel paint over one coat of Red oxide primer on the following items after scrapping and cleaning of the surface wherever necessary. Primer & paints both of approved quality( (i.e The paint and primer should be from Asian Paints/ Nerolac / Dulux / Berger.The primer / enamel paints (Aluminum synthetic, black enamel, brilliant white and yellow) will be as per (IS 5660 of 1970) / (IS 2932 of 1974) ) are to be supplied by Contractor. This includes: (i) Lettering/Numbering of Signals,Points, Apparatus cases, TLJB, etc. (Rate taken from Average of LOA)
Hiring Charges of one no.of Disel Vehicle ( Scorpio / Bolero / Tata Sumo or equivalent disel driven Vehicle) for inspection of Railway & RITES officials as reqd. Note:- i) Vehicle should have valid road licence,driving licence ,polution certificate etc.ii) Age of the vehicle should not be more than 2 (two) years.iii) Rate included all running cost,like cost of diesel,mobil ,wage of driver etc.iv)Working Period - Minimum 2500 Kms per month as per requirments of site work.v)During repairing time of the vehicle if required,then separate vehicle of similar nature to be supplied by the contractor for smooth working at site. (Rate taken from Average of LOA)
Earthing, EKT Fixing, DG Set InstallationFixing of earth electrode including laying and installation of MS flat of size 35 mm x 6 mm with length 5 mtr or as per extant practice of Eastern Railway. As per CSTE/ER'S DRG. NO. S&T 1/2007 for apparatus cases, signal post & other equipment as per instruction of site engineer. Provision for fixing MS flat at apparatus cases/ signal post/other equipment should be made by the firm at site. Full threaded bolts of 10 mm dia and length 40 mm should be welded in the apparatus cases in such way that the MS flat at apparatus case end can be fixed from outside or from inside. Welding arrangement with accessories and welding materials should be arranged by the contractor for fixing of bolts at equipment end where required as per instruction of site engineer. All hardware and other miscellaneous materials required for installation to be supplied by the contractor except earth electrodes and MS flat.Note:-all materials required to be arranged by the contractor except 2/6 core.. (Rate taken from ER SOR S&T 2022)
Supply,Installation, wiring, testing & commissioning of Rotary Key Transmitter. This includes fixing of key transmitter on hylum sheet, termination of cables, wiring of key transmitter & supply of hylum sheet, wiring material, nuts & bolts etc. (Rate taken from Average of LOA)
Installation, wiring, testing and commissioning and earthing of 10 KVA Diesel Generator Set (DG). DG set to be mounted on anti-vibrating pad & also in a sound proof accoustic enclosure. All materials required for the work to be supplied by the contractor. Wiring to be made in such a way, that the DG set can be made to Start & Stop from SM's operating room with the facility to change over power supply through a 3-position Change over switch (63Amps). (Rate taken from Average of LOA)
UFSBI/HASSDAC/PA system/Surge Protection Installation, Testing & commissioning of Block proving by Axle Counter (BPAC) including UFSBI equipment as per standard practice & directive of engineer in charge and as per OEM guidelines. (Rate taken from ER SOR S&T 2022)
Installation and commissioning of PA system complete with wiring including power supply.(Rate taken from Average of LOA)
Supply & installation of power distribution board with fittings for telecom installation consisting of: (i) MCB-M 9 single pole 240/ 415V rating 6 Amps, make Havels or similar; (ii) 8 Nos. of 5 /15 A three pin plug & sockets with indivdual switches; (iii) Power On / Off indicator lamp with fuse and connecting the PA system equipments etc.(Rate taken from Average of LOA)
Supply & installation of Power distribution board for signaling installation with fittings consisting of : (i) MCB-M9 single pole 240/415 V rating 10 A, make Havels or similar; (ii) 8 Nos. of 15 Amps Three pin plug & sockets with indivdual switc hes; (iii) Power On/Off indicator Lamp with fuse and connecting various supply voltages (as decided by the site Incharge)..(Rate taken from Average of LOA)
Supply and installation of lightning and surge protection device both Class 'B' & Class 'C' between line and neutral and neutral & earth of approved type. (Rate taken from ER SOR S&T 2022)
Installation, wiring, testing & commissioning of Data Logger, FEP, FAS, Power supply arrangement with accessories complete in all respect with door locking facilities/ arrangement. Note: Data Logger to be installed at site by the Engineer of the original manufacturer of the equipment from where it is being procured by the contractor. .(Rate taken from Average of LOA)
Installation of Distilled Water Plants at Railway Cabin & at Cement siding cabin which include necessary power supply arrangements with 15 Amps plug, sockets & fuse blocks along with water supply connections (with GI/polythene pipes) if available, at both locations or to be connected to one 100 litres polythene water tanks at suitable height as per dvice of site incharge. Necessary materials required for this purpose to be borne by the contractor for commissioning of the system..(Rate taken from Average of LOA)
Fixing of Number Plates with complete fittings as per instruction of site engineer. The marker to be etched & enamelled before painting..(Rate taken from Average of LOA)
Installation, testing & commissioning of Interlocking System..(Rate taken from Average of LOA)
Post Commissioning Maintenance of S&T Gears. This includes routine maintenance and attending failures of newly installed/commissioned S&T equipments/system under the scope of work in this contract,Disele oil,spares require and other sundry items for cleaning ,oiling,adjustments shall be arranged by the contractor..(Rate taken from Average of LOA)
Dismantling of all released Signaling gears & its disposal as per advice of Site Incharge including loading, unloading and transportation..(Rate taken from Average of LOA)
IPS Installation Installation, testing, and commissioning of IPS system SMPS based for Panel Interloked station Note: supply, installation of Power Board in IPS room is also included in above work as per railway standard or as per site engineer instructions..(Rate taken from Average of LOA)
Installation of LT Power Panel/ Power distribution panel/ Auto Changeover Panel, power supply equipments such as Rectifiers Transformers, Battery chargers etc. including mounting on wooden planks/Hylum Sheet and complete wiring for automatic change over arrangement, mounting of Program switches on Bakelite sheet of size 300 mm x 300 mm x 8 mm fitted to MS angle (size 25mm x 25mm x 5mm) brackets, wiring as per requirements. Necessary wires, lugs & glands to be supplied by Contractor. (Rate taken from ER SOR S&T 2022)
EI / PI Installations Installation, Indoor wiring of vital IO's from EI system upto CT Racks, Indoor Relay wiring for interface Circuits etc,Testing (including FAT, SAT) ,Data Input & Configuration,Diagnostic & Trouble Shooting and Commissioning of El as per SIP .(Rate taken from MRA)
Design & Supply of Documents ( It should contain module on installation etc). Design Includes Interface & Interlocking circuits,(Rate taken from MRA)
Training of Railway Personnel by OEM for installation, Commissioning, Testing, troubleshooting & making changes in application data and logics by railway officials to suit yard modification done at later stage including documentation. (Hard copies of training material/ course modules to be given to each participant).(Rate taken from ER SOR S&T 2022)
OFC works/Micro tunnelling Supply of optic fibre splice closure (24 fibre) as per tec. Specification no. G/OJC-02/01, March'99 with latest amendment or latest including all miscellaneous items and consumables for fibre splicing. (Rate taken from ER SOR S&T 2022)
Laying of OFC Cable through 40 mm dia HDPE Pipe, thickness 4 mm +/- 0.3 mm as per specification no. TEC GR No.: G/CDS-08/01 Dec' 99 with latest amendment no.: 5 or latest after making microtunnelling at a depth of Min. 1.7 M without damaging underground of sorts/drain, water supply pipe etc. The work repair of damage metal road/concreating floring and making pit as per requirement to suit the laying of HDPE pipe and also includes the supply of HDPE Pipe 40 mm dia thickness 4 mm +/- 0.3 mm as per specfication no.: TEC GR No.: G/CDS-08/01- Dec' 99 with latest amendment no.: 5 or latest. HDPE pipe will be supplied by the contractor. All other material required for laying OFC, HDPE etc will be supplied by the contractor. .(Rate taken from Average of LOA)
Transportation of HDD machine with accessories including handling of stores materials, preparation of sites and boring for placing of 110 mm dia HDPE PIPE for crossing of S&T cables together a bridges/culvers, pucca road/crossing, boring trench shall be minimum 3 (three) meter below the river bed and 1(one) meter below the track/road/pucca road crossing area. This includes supply of accessories for HDPE pipes, including, cost of fuel and all other items etc. which will be required for laying of cable through it.the work shall be executed as per instruction of site engineer.HDPE PIPE TO BE SUPPLIED AS PER RDSO SPEC. Contactor shall provide all material required for boring and adequate nos. of labours for proper laying of cables into the bore. Cable shall be laid cautiously so that it should not get damage due to rough handling & pressure on cable. - Boring up to the length of 150 meters. Preparation of site for Horizontal Boring shall be carried out in presence of Site Engineer. (Rate taken from ER SOR S&T 2022)
Horizontal Drilling by using manual pushing method at minimum depth of 1.5 meter below the formation level of earth as per decision of Engineer in charge .Pipe Supply is not covered under this item. (Rate taken from ER SOR S&T 2022)
Laying of 6 quad/Signalling cable/Power Cable with nylon rope through 110 mm HDPE pipe and back filling of boring pit. (Rate taken from ER SOR S&T 2022)
Supply and installation of Optical Fibre termination Box as per Specn. No. DPG/G/FIB-01/02 Mar '99 or DOT/G/FTB-01, Jan. '93 or with latest amendment and splicing of all the fibres inside the termination box with provision of taking out OFC as required. This includes supply of all installation accessorise required to complete the installation as per specn. no. G/OFJ-01/03 June '99 with latest amendment 10 mtr. long Patch cord as per Specn. No. G/OJF-01/01 including with latest amendment with connector as per code of practice for installation and commissioning of OFC through (STT/FO/T issued by RDSO/LKO). Supply items should be inspected by RDSO.(Rate taken from Average of LOA)
Maintenance free earthingSupply and Installation) Basic earthing kit consisting of ( a ) (i):Earth electrode of copper clad steel along of 6 feet long 3/4 inch dia & copper thickness of min of 10 mm = 2 nos.(ii)Threadless compressed type coupler = 1 no.(iii)RDSO approved earth enhancing compound in 10kg packet - 1 no.(iv)Copper tape of 25mmx6mmx300mm with 99.9% purity - 2 no. and another of 25mmx6mmx150mm to terminate on earth electrode. (Rate taken from Average of LOA)
Supply and Installation) Basic earthing kit consisting of (b) Insulated Cadmium bronze cable of 3/16" to RDSO spec.No.178/2003 to connect equipotential bus bar in relay room and surge arrestor Box.(Rate taken from Average of LOA)
Supply and Installation) Basic earthing kit consisting of (c) Routing of PVC multi strand Copper cable of 6 sqmm for various equipments and lightening protection devices to equipotential bus bar. Note: Basic Earthing Kit to be installed at site by the Engineer of the original manufacturer of the equipment from where it is being procured by the contractor. Weld materials & tools & fixtures for the weld shall be arranged by the contractor.(Rate taken from Average of LOA)
Supply and fixing of RE Pretective screens on signal(Rate taken from Average of LOA)
Provision of temporary Goomties for NI working including Provision of Public Address System complete with Microphones speakarsetc in the Yard during Non Interlocking Work(Rate taken from Average of LOA)
Supply and fixing of Rubber matting thickness 2 MM as per IS: 15652-2006 with suitable adhesive material(Rate taken from Average of LOA)
Installation of class A device on the top of the building: the device shall be installed at a height of about of about 3 mtrs. From the roof of the building using a GI mast. The device shall be connected to earth pit using the copper tape of 25 mm x 2 mm or better. This copper tape shall be run firmly along the side of the mast with help of spacers. It shall also be ensured that this down conductor shall not touch the building throughout. The down conductor should be connected to earth electrode using exothermic welding or better. A counter shall be installed at a appropriate place to count number of occurrences.(Rate taken from ER SOR S&T 2022)
Installation, testing and mounting of G.P. antenna on a GI pipe which is to be fitted on the roof of equipment room and lightning arrestors also to be mounted on a GI pipe. All fixing materials to be supplied by the tenderer and left over material to be returned to the client store. (Rate taken from ER SOR S&T 2022)
Installation of 4W way station DTMF equipment as per RDSO spec. no IRS-TC/60/93 or latest ( with 4 wire telephone as per spec. No IRS-TC-38/97 or latest. Make- Bentron, Epsilon or similar and supply of 12V/7AH power supply unit for control phone.(Rate taken from ER SOR S&T 2022)
Please Enable Macros to View BoQ information
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
cancelled_1.pdf
pdf • 0.18 MB
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.28 MB
TD05OT.pdf
Tender Documents • 33.25 MB
Drg05OT.pdf
Other Document • 0.31 MB
BOQ_309023.xls
BOQ • 0.61 MB
Download all tender documents and submit your bid