| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹13.4 LAccepted-AOC | ₹13.4 L | L1 | Accepted-AOC BEING L1 AND REASONABLE |
| 2 | L2₹16.9 L+₹3.4 L (25.6%)Rejected-Finance R O WARD NO 08 H NO 108 DHAR ROAD UDHAMPUR TEHSIL DISTT UDHAMPUR 182101 | UDHAMPUR | UDHAMPUR | JAMMU KASHMIR | 182101 | ₹16.9 L+₹3.4 L (25.6%) | L2 | Rejected-Finance OTHER THAN L1 |
| 3 | Rejected-Technical NEAR MES FILTER PLANT SANGOOR UDHAMPUR J K 182101 | UDHAMPUR | UDHAMPUR | J K | 182101 | - | - | Rejected-Technical Not Approved. Not enlisted in b iii category. |
| 4 | Rejected-Technical 15A 9 CHOWBHAGA ROAD KOLKATA KOLKATA 700039 | KOLKATA | WEST BENGAL | 700039 | - | - | Rejected-Technical Not Approved. Not enlisted in b iii category. |
| 5 | Rejected-Technical C O SECTOR 02 HOUSING COLONY CHANNI HIMMAT JAMMU J K PIN 180015 | JAMMU | JAMMU AND KASHMIR | 180015 | - | - | Rejected-Technical Not Approved. Not enlisted in b iii category. |
Tender Value
₹15 L
EMD Value
₹30,000
Closing Date
27 Oct 2022, 6:00 pmClosed
Col Sachin Sharma CWE
Military Engineer Services, Commander Works Engineer, Udhampur, PO - Garhi, Udhampur-182121
REPAIR/ MAINT OF HT UNDERGROUND CABLE, HT SWITCH GEAR AND ALLIED WORKS AT 132/33 KV UNDER RAC SUB DIVISION UNDER GE (UTILITIES) UDHAMPUR
2022_MES_548928_2
CWE/U(U)-60/2022-23
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
UDHAMPUR
AS PER TENDER DOCUMENTS
7 documents required · 7 mandatory
₹500
GE (UTILITIES) UDHAMPUR
₹30,000
Yes
12 Nov 2022
8 Oct 2022
29 Oct 2022
8 Oct 2022
27 Oct 2022
15 Oct 2022
Amount
M & L for carrying out following Onsite Tests for 132 / 33 KV 20 MVA Transformer of any capacity with required / suitable testing equipment by Qualified and Licensed Personal, Recording Test Results and submitted to GE to keep on record duly signed by all concerned complete all as specified and as directed: [a] IR Test [b] PI [c] Magnetic Balance Test [d] Ratio test [e] Di-electric Test of Oil [f] Short Circuit Test [g] Vector Group [h] Winding Resistance
M & L for Repairing / Servicing of potential transformer single phase oil immersed, self cooled, hermetically sealed outdoor type, 145Kv, 50Hz, Ratio (132000 V)/(110/√3) including carrying out following activities complete all as specified and as directed: [a] Checking PT Limb[Ceramic insulator] for any cracks, pitting and burns [b] Cleaning / Decarbonising with CTC [c] Carrying / conducting Ratio Test. [d] Tightening all Primary and Secondary connections. [e] Tightening and fixing basement Nuts & Bolts.
All as per item No. 02.00 but for 36KV potential transformer (33Kv)/ (110V/√3) hermetically sealed
All as per item No. 02.00 but for 145KV current Transformer 400-200-100 / 1A outdoor type
All as per item No. 02.00 but for 145KV current Transformer 800-400-200/1A outdoor type
All as per item No. 02.00 but for 33KV current Transformer 400-200-100/1A outdoor type
All as per item No. 02.00 but for 33KV current Transformer 800-400-200/1A outdoor type
M & L for repairing & servicing of 132 KV Isolator & Earth Switch including carrying out following activities complete all as specified and as directed: [a] Cleaning of contact for dust, oxidation & pitting with CTC. [b] Cleaning of all insulators with CTC and observing any cracks and carbon deposits / contents. [c] Repairing, adjusting the rotating arms for perfect operation including lubrication with Petroleum Jelly [d] Repairing / Replacement of Tension Spring in Fixed Contacts. [e] Lubricating of all moving parts for smooth operation. [f] Checking of Auxiliary Contacts and their Calibration [g] Applying Petroleum Jelly to all Electrical Contacts / Moving Contacts. [h] Tightening of all Electrical and Mechanical Connections. Note: The rate quoted is deemed to be inclusive of Consumables like nuts & bolts, washers, petroleum jelly, CTC, T & P etc. complete and necessary safety measures for working in 33 KV Yard.
All as per item No. 08.00 but for 33 KV Isolator & Earth Switch
1100 Volts PVC insulated FRLS copper conductor control armoured cable shall comply with standards as IS 1554 (partI and partII)pvc Insulated heavy duty electric cable, is 5831 PVC insulation and sheath of electric cable, is 8130 conductor for insulated electric cable and cords, is 3961 current rating of cable, IS 502 extended solid dielectric insulated power cable for rated voltage from 1KV to 30KV, IEC 540 and 540A test methods for insulation and sheath of electric cable and cords, IEEE 383 standard for type test for class II electric cable field splices and connections, swedish standard and SS 424 1475 ClassF3 for flammable test, IEC 332-1 test on electric cable under fire condition, IEC 754 -1 test method for acid generation, ASTMD-2863 oxygen index test and temperature index test NEMA WC5 for accelerated water absorption test and dielectric strength retention test construction of cable shall be such that the PVC fillers will be used to provide uniform circular cross section before the inner sheath is applied. All material shall comply the applicable provisions of the test mentions in the specifications mentioned above, current rating and derating factors under normal conditions of installation shall be as per latest amendment IS-3961 (Part-II) the length of the cable shall be supplied in drum length of 500m for all sizes with tolerance of only 5% of ordered quantity of size 2.5sqmm 7 core armoured complete all as specified and as directed by Engr-in-Charge.
All as per item No. 10.00 but for 2.5 SQMM 6 Core
M & L for cleaning and servicing of complete HT 33 KV 4 pole isolator structure by greasing, cleaning, servicing of jumpers, re-jumpering wherever required, tightening of nuts & bolts etc. including painting with two coats of aluminium paint over a coat of zinc chrome primer on all steel surfaces from main receiving point to distribution bus bar bay structures up to transformers inside MRS complete, all as specified and directed by Engr-in-Charge.
S & F in repairs Silica Gel into Breather of Transformers complete, all as specified and directed by Engr-in-Charge.
M & L for Repairs / Servicing of 145KV SF6 circuit breaker out door type with breaking cap 31.5 KA having nominal system voltage 132 KV & rated voltage 145Kv 50Hz, 3 Poles(G.O) out-door interrupting Cap, rated normal current 1250 A, having 2 trip coils auxiliary contacts 12 NO & 12 NC, closing coil 1 No. Arcing time 25 milliseconds, Tripping & closing control circuit voltage 110V DC and spring operated mechanism of ABB make comprising of the following complete all as specified and as directed: [a] Cleaning of Interrupter Limbs for Dust, Oxidising and Decarbonising with CTC. [b] Repair / Servicing of Spring Loaded Operating Mechanism [c] Repair / Servicing of Spring Charging Motor [d] Checking, repairing & servicing of Gearbox, Auxiliary Switches, Spring, Limit Switch etc. complete [e] Checking & Repairing Electrical and Mechanical Operations [f] Checking & Repairing Remote Closing and Tripping of SF6 bracker from Control Panel. [g] Lubrication all Moving Parts with Petroleum Jelly & cleaning all Bushing Insulators with CTC [h] Tightening of all Mechanical Connections of Mechanism [i] Tightening of all HV and LV Connection. Note: Spares required for Servicing / Repairing of SF6 bracker shall be measured and separately under respective items of this BoQ at supply only rates.
M & L for Repairs / Servicing of 36KV VCB outdoor type with hallow porcelain insulated porcelain clad VCB having nominal system voltage 33KV highest system voltage 36KV interrupting capacity rated normal current 1250A, frequency 50Hz, short circuit current 25KA, control circuit voltage 110V DC, of ABB make and comprising of the following complete all as specified and as directed: [a] Cleaning of Vacuum Interrupter Limbs for Dust, Oxidising and Decarbonising with CTC. [b] Repair / Servicing of Spring Loaded Operating Mechanism [c] Repair / Servicing of Spring Charging Motor [d] Checking, repairing & servicing of Gearbox, Auxiliary Switches, Spring, Limit Switch etc. complete [e] Checking & Repairing Electrical and Mechanical Operations [f] Checking & Repairing Remote Closing and Tripping of VCB from 33KV Control Panel. [g] Lubrication all Moving Parts with Petroleum Jelly & cleaning all Bushing Insulators with CTC [h] Tightening of all Mechanical Connections of Mechanism [i] Tightening of all HV and LV Connection of VCB. Note: Spares required for Servicing / Repairing of 36 KV Circuit Breaker shall be measured and separately under respective items of this BoQ at supply only rates.
Supply only following spares suitable for 145 KV Outdoor type SF6 Breaker of make:ABB Model No LTB145D1/B complete all as specified & directed by Engineer-in-charge:-
Damper suitable for 145 KV Outdoor SF6 Breaker of make ABB cat part No 1HYB300862-A as per existing model complete all as specified & directed by Engineer-in-charge.
Tripping latch Assembly for 145 KV Outdoor SF6 Breaker of make ABB cat part No EXIN200410-R1 as per existing model complete all as specified & directed by Engineer-in-charge.
Closing latch Assembly for 145 KV Outdoor SF6 Breaker of make ABB cat part No EXIN200416-R1 as per existing model complete all as specified & directed by Engineer-in-charge.
Closing coil 110/220V for 145 KV Outdoor SF6 Breaker of make ABB cat part No EXIN400834-R9 as per existing model complete, all as specified and directed by Engr-in-Charge.
Triping coil 110/220V for 145 KV Outdoor SF6 Breaker of make ABB cat part No EXIN400833-R9 as per existing model complete all as specified and directed by Engr-in-Charge.
Closing Spring Assembly for 145 KV Outdoor SF6 Breaker of make ABB cat part No 1HYB300784-A as per existing model complete all as specified and as directed.
Triping Spring Assembly for 145 KV Outdoor SF6 Breaker of make ABB cat part No 1HYB300785-A as per existing model complete all as specified & directed by Engineer-in-charge.
Drive unit motor, Type 220V AC/DC for 145 KV Outdoor SF6 Breaker of make ABB cat part No EXIN-300802-R1 as per existing model complete all as specified & directed by Engineer-in-charge.
Limit Switch with bracket complete for 145 KV Outdoor SF6 Breaker of make ABB cat part No 1HYBN700023R1 as per existing model complete, all as specified and directed by Engr-in-Charge.
Supply only following spares suitable for 36 KV Outdoor Vacuum Circuit Breaker of Make: ABB model No OVB-VBF 36 complete, all as specified and directed by Engr-in-Charge:-
Geared motor for 220-250V DC suitable for 36 KV Outdoor VCBs of ABB cat part No 1VRC007323G0005, as per existing model complete all as specified and directed by Engr-in-Charge.
MC open Coil Mo1(220-250V DC/220-250V AC) suitable for 36 KV Outdoor VCBs of ABB cat part No 1VCR004289G0007 as per existing model, complete all as specified and directed by Engr-in-Charge.
Auxiliary Switch 8NO + 8NC suitable for 36 KV Outdoor VCBs of ABB cat part No 1 VYN301450-041 as per existing model complete, all as specified and directed by Engr-in-Charge.
Trip Coil MO2 Assly 48Vca-Vcc (Addiyional trip) suitable for 36 KV Outdoor VCBs of ABB cat part No 1VCR002985G0003 as per existing model complete, all as specified and directed by Engr-in-Charge.
Shunt closing release - MC24VDC suitable for 36 KV Outdoor VCBs of ABB cat part No 1VCR004291G0001 as per existing model complete, all as specified and directed by Engr-in-Charge.
MU Coil Assly (48V AC-DC) Under Voltage suitable for 36 KV Outdoor VCBs of ABB cat part No 1VCR004290G0003 as per existing model complete, all as specified and directed by Engr-in-Charge.
MC Closing Coil (220-250VDC/220-250V AC) suitable for 36 KV Outdoor VCBs of ABB cat part No 1VCR004291G0007 as per existing make & Model complete, all as specified and directed by Engr-in-Charge.
Supply , laying and testing and commissioning of HT Cable XLPE insulated , screened, PVC bedded galvanised steel strip or wire armoured electric power cable ( heavy duty) with aluminium conductor , 33000 volts earthed grade cross sectional area 400 Sqmm 3 core, laid in trenches, through pipe in road crossing, ducts, fixed along poles, complete all as specified and directed by Engr-in-Charge.
M&L for heat shrinkable type end termination joint kit outdoor type suitable for XLPE insulated HT cable 33000 Volts grade of size 400 Sqmm 3 core complete with jointing material and accessories along with testing after jointing including taking out the old unserviceable joint kit complete all as specified and directed.
M&L for Dehydration including filtration and cleaning of Transformer oil by dehydrating machine incl testing of sample before and after dehydration and filtration and replacement of silica gel all as specified and directed NOTE:- dehydration machine and testing kit will be provided by the Dept. but transportation of machine is the responsibility of Contractor without any extra cost to the dept. Sample testing will be carried out in the presence of Engr-in-Charge on site.
Supply & Filling /pouring of up to the appropriate level Transformer oil of low viscosity having dielectric strength not less than 60 KV complete all as specified and as directed NOTE:- Dielectric strength test shall be carried out at site before poring/filling in transforme
Supply & Fixing of PG clamp 4 bolt suitable for ACSR Zebra conductor complete all as specified & Directed by Engr-in-Charge
Supply & Fixing of 3 phase S1 duty, electric motor for Isolator Jn Box 0.5 HP, 415 V+10%, 50Hz+5%, 1410 RPM complete all as specified & Directed by Engr-in-Charge
M&L for 36KV porcelain Post insulator having highest system voltage 36KA. 50Hz short ckt current 25KA, phase to phase distance 1.5M height of insulator 508.00mm used for support ACSR conductor use for interconnection complete all as specified & Directed by Engr-in-Charge
M&L for 145Kv porcelain Post insulator having highest system voltage 145Kv, 50Hz short circuit current 31.5 KA, phase to phase spacing 3m height of insulator 1460 mm used for support ACSR conductor use for interconnection complete all as specified & Directed by Engr-in-Charge
Supply and fix disc type insulator including its accessories of GI for 33 KV volts grade with three 11 KV insulator in one series. (One unit shall be set of three)
Supply and fixing in replacement 240V, 10 KA 'C' curve miniature circuit breaker (MCB) of single poles and current carrying capacity upto 32 AMP, in the MCB DB Complete with connection all as describe by Engr-in-Charhe
Description all as per item No 27.00 described above but for upto 63 Amp TP
S & F Aluminium conductor steel reinforced (ACSR) any size on poles, stretched on LT poles without any kink and bends of various sizes complete including fixing to insulator with Aluminium binding wire complete all as specified and directed by Engr-in-charge.
M&L For taking out ACB trolley from LT control panel 415 V 3 phase 800 Amp , 50 kA, 4 Pole (Make :- schneider) and cleaning the ACB with CRC removing all dust , carbon etc greasing the mechanical parts gears ,lever charging male female contacts and spring holders and testing and calibration for overload current and fault current complete all as specified and directed by Engr-in-charge.
Material and labour for calibration of overcurrent earth fault relay of make Siemens ( model No 7SJ66) as per existing load for earth fault , over current and short circuit ,including setting the relay on required electric load and testing on earth fault and short circuit and over load with the help of relay testing kit for 132KV & 33 KV system complete all as specified and directed by Engr-in-charge.
Supply & Fixing in replacement Lightning arresters expulsion type complete with all fittings, transmission class, discharge capacity 65 kilo amp suitable for 33 KV line complete all as specified & Directed by Engr-in-Charge
slathia construction works
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .