Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance | Admitted-Finance |
| 2 | Admitted-Finance | Admitted-Finance |
| 3 | Admitted-Finance 202 1ST FLOOR VIVEKANAND PURI MALKAGANJ SARAI ROHILLA NORTH DELHI DELHI 110007 UDYAM DL 01 0065084 | NORTH DELHI | DELHI | 110007 | Admitted-Finance |
| 4 | Admitted-Finance 4264 GALI SHAHTARA AJMERI GATE DELHI DELHI 110006 | NORTH DELHI | DELHI | 110006 | Admitted-Finance |
| 5 | Admitted-Finance 1008 A PREMIER ENGINEERING COMPANY PURVI RITHANI MEERUT DELHI ROAD MEERUT UTTAR PRADESH 250103 INDIA | MEERUT | UTTAR PRADESH | 250103 | Admitted-Finance |
Tender Value
Refer Docs
EMD Value
₹13,000
Closing Date
20 Aug 2024, 1:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
EE(SDW)-I
Kilokari SPS Jal Vihar New Delhi
N.I.T. NO.02 EE(SDW)-I 2024-25 ITEM NO. 2
2024_DJB_260968_2
NIT No.02 EE(SDW)-I 2024-25
Open Tender
Miscellaneous Works
Works
30 days
Work
Please refer tender documents
3 documents required · 3 mandatory
₹500
Online
₹13,000
Yes
29 Aug 2024
13 Aug 2024
20 Aug 2024
13 Aug 2024
20 Aug 2024
13 Aug 2024
Electrification of type - IV quarter No. 3, 4, 10 & D-12 of staff quarter at Jal Vihar Colony as mentioned below:- 1.10/2 Wiring for light point / fan point / exhaust fan point call bell point with 1.5 Sq. mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium PVC conduit, with modular switch, modular plate, suitable size modular box and earthing the point with 1.5 Sq. mm FRLS PVC insulated copper conductor single core cable etc. as required. Group-B.
1.14/3 Wiring for circuit/ sub main wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. 1.14.2 2 x 2.5 sq. mm + 1 x 2.5 sq. mm earth wire.
1.14.3 2 x 4 sq. mm + 1 x 4 sq. mm earth wire
1.14.3 2 x 10 sq. mm + 1 x 6 sq. mm earth wire
1.31/7 Supplying and fixing suitable size GI box with modular plate & cover on surface or in recess including providing and fixing 3 pin 5/6 A socket outlet and 5/6 A modular type switch, connections, etc. as required.
1.32/7 Supplying and fixing suitable size GI box with modular plate & cover in front on surface or in recess including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A Modular switch, connections, etc. as required.
1.25/6 Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.
1.33/7 Supplying and fixing 3 pin, 5 A ceiling rose on the existing junction box/ wooden block including connections etc. as required.
1.34/7 Supplying and fixing brass batten/ angle holder including connection etc. as required.
1.38/7 Supplying and fixing call bell/ buzzer suitable for single phase, 230 V, complete as required.
1.41/7 Installation, testing and commissioning of pre-wired, fluorescent fitting / compact fluorescent fitting of all types, complete with all accessories and tube/lamp etc. directly on ceiling/ wall, including connections with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required.
1.44/8 Installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length upt 30cm with 1.5 Sq. mm FRLS PVC insulated, copper conductor single core etc. as required.
1.50/8 Installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required.
2.4/11 Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface / recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required (But without MCB/RCCB/Isolator). 2.4.1 - 4 way (4+12), double door.
2.10/11 Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, “C” curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. 2.10.1 - Single pole.
2.14/12 Supplying and fixing following rating, three pole, (three phase and neutral), 240 volts, residual current circuit breaker (RCCB), having sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required. 2.14.3 - 63 A.
Making good the damages by required civil work as per requirement.
Goodwill Enterprises
paramount systems
Travionyx Technologies Private Limited
S N ELECTRICAL AND CONTROL PANELS
Premier Engineering Company
SAI TRADING CORPORATION
MITTAL TRADING COMPANY
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .