| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹29.2 LAccepted-AOC | L-1 | Accepted-AOC Being lowest bidder | |
| 2 | L-2₹34.3 L+₹5.1 L (17.4%)Rejected-Finance KERNI MARKET COURT ROAD UDHAMPUR J K 182101 | UDHAMPUR | UDHAMPUR | J K | 182101 | L-2 | Rejected-Finance Other than lowest bidder | |
| 3 | L-3₹37.1 L+₹7.9 L (27.0%)Rejected-Finance | L-3 | Rejected-Finance Other than lowest bidder | |
| 4 | L-4₹37.2 L+₹8.0 L (27.2%)Rejected-Finance QTR NO 7 REHARI COLONY JAMMU TAWI J K PIN 180005 | JAMMU | JAMMU AND KASHMIR | 180005 | L-4 | Rejected-Finance Other than lowest bidder | |
| 5 | L-5₹37.9 L+₹8.7 L (29.7%)Rejected-Finance | L-5 | Rejected-Finance Other than lowest bidder |
| Sl No | Description | Qty | Unit | Hare krishna engineering const. L4 | M/s Koul & Sons L3 | Shri Karshni Builders L1 | M/S IMTESH BHAT L5 | M/S ELECTROMATICS L9 | kerni electricals L2 | SHARMA CONSTRUCTION COMPANY L8 | Mehta Enterprises L7 | M/S TRIKUTA BUILDERS L6 |
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 1.00 | B/R Portion: -
Demolition of brick work built in cement mortar including all quoins, arches, pillars etc. complete all as specified and as directed. | 3 | Cubic Metre | 50 ₹150 Lowest | 80 ₹240 | 200 ₹600 | 99 ₹297 | 500 ₹1,500 | 100 ₹300 | 90 ₹270 | 100 ₹300 | 500 ₹1,500 |
| 2.00 | Material and labour in replacement for brick work with sub class ‘B’ bricks straight or curved on plan exceeding 6 mtr mean radius built in cement mortar (1:6) complete all as specified and as directed. | 3 | Cubic Metre | 3,000 ₹9,000 Lowest | 4,800 ₹14,400 | 3,800 ₹11,400 | 3,999 ₹11,997 | 5,800 ₹17,400 | 4,000 ₹12,000 | 5,400 ₹16,200 | 4,000 ₹12,000 | 6,000 ₹18,000 |
| 3.00 | Demolition of cement concrete (unreinforced) of any description and in any position not otherwise specifically provided for and complete removal of debris outside MOD land complete all as specified and as directed. | 27.25 | Cubic Metre | 100 ₹2,725 | 80 ₹2,180 | 50 ₹1,362.5 Lowest | 99 ₹2,697.75 | 200 ₹5,450 | 100 ₹2,725 | 90 ₹2,452.5 | 100 ₹2,725 | 100 ₹2,725 |
| 4.00 | Material and labour plain cement concrete (1:2:4) type B-0 (using 12.50mm graded crushed stone aggregate) 25mm thick as in sub base for floor tiles complete all as specified and as directed. | 500 | Square Metre | 50 ₹25,000 Lowest | 140 ₹70,000 | 70 ₹35,000 | 220 ₹1,10,000 | 200 ₹1,00,000 | 250 ₹1,25,000 | 270 ₹1,35,000 | 150 ₹75,000 | 100 ₹50,000 |
| 5.00 | Dismantling floors, hearth or wall tilling including cement mortar bedding (but not backing) removing unserviceable materials outside MOD area and rubbish off the premises complete all as specified and as directed. | 790 | Square Metre | 20 ₹15,800 | 10 ₹7,900 | 5 ₹3,950 Lowest | 9 ₹7,110 | 22 ₹17,380 | 10 ₹7,900 | 9 ₹7,110 | 10 ₹7,900 | 50 ₹39,500 |
| 6.00 | Material and labour plain cement concrete (1:4:8) type D-2 (using 40 mm graded crushed stone aggregate) as in foundation, filling and mass concrete, RCC sunken portion as base layer for receiving top layer complete all as specified and as directed by Engineer-in-Charge. | 1 | Cubic Metre | 2,000 ₹2,000 Lowest | 3,800 ₹3,800 | 4,000 ₹4,000 | 2,969 ₹2,969 | 6,000 ₹6,000 | 3,100 ₹3,100 | 2,700 ₹2,700 | 5,000 ₹5,000 | 3,000 ₹3,000 |
| 7.00 | Material and labour for Glass fibre reinforced modified cementitious coating system before the final coat of Latex Shield 2K (or equivalent) in sunken treatment. Base coat : Berger HS Latex plus (or equivalent), Consumption base coat : 0.3 Kg/Sqm, Reinforcement : Glass fiber, Second and Third coat : Latex shield 2K (or equivalent), Consumption top coat : 3 Kg/Sqm, System requirements : density : 2.00 Kg/Ltr, Compressive strength : 0.5 N/Sqmm. (i) Wall penetration through the RCC slab must be sealed using Berger HS Repir (or equivalent). (ii) Intersection of base slab with wall must be provided with a 50 mm fillet using Berger HS Latex plus (or equivalent) modified mortar with a bonding coat of Berger HS Latex plus (or equivalent) modified cement slurry upto 1.5 Mtr. (iii) All depressions, unevenness, surface honeycombing shall be repaired using Berger HS Latex plus (or equivalent) modified polymer mortar with a bonding coat of Berger HS latex plus (or equivalent) modified cement slurry, including cleaning of RCC surface to remove dust, loose particles, etc with compressed air or any other suitable technique depending on site conditions, grinding any sharp edges, etc complete all as specified and as directed. | 12 | Square Metre | 700 ₹8,400 | 450 ₹5,400 | 300 ₹3,600 Lowest | 479 ₹5,748 | 600 ₹7,200 | 2,500 ₹30,000 | 600 ₹7,200 | 1,000 ₹12,000 | 1,000 ₹12,000 |
| 8.00 | Material and labour non-skid ceramic tiles 7 to 8 mm thick (square/rectangular) area of each tile exceeding 0.18 Sqm but not exceeding 0.38 Sqm, in floors etc. fixed with approved tile adhesive and provided with 4mm spacer, spacer gaps to be filled with approved epoxy grout complete all as specified and as directed by Engineer-in-Charge. | 440 | Square Metre | 900 ₹3,96,000 | 800 ₹3,52,000 | 900 ₹3,96,000 | 799 ₹3,51,560 | 780 ₹3,43,200 | 750 ₹3,30,000 Lowest | 1,080 ₹4,75,200 | 1,100 ₹4,84,000 | 900 ₹3,96,000 |
| 9.00 | Material and labour non-skid ceramic tiles 7 to 8 mm thick (square/rectangular) in vertical surface such as skirting, dado etc. fixed with approved tile adhesive and provided with 4mm spacer, spacer gaps to be filled with approved epoxy grout complete all as specified and as directed by Engineer-in-Charge. | 40 | Square Metre | 900 ₹36,000 | 900 ₹36,000 | 800 ₹32,000 | 799 ₹31,960 | 850 ₹34,000 | 780 ₹31,200 Lowest | 900 ₹36,000 | 1,100 ₹44,000 | 900 ₹36,000 |
| 10.00 | Material and labour non-skid ceramic tiles 7 to 8 mm thick (square/rectangular) area of each tile not exceeding 0.18 Sqm, in floors etc. fixed with approved tile adhesive and provided with 4mm spacer, spacer gaps to be filled with approved epoxy grout complete all as specified and as directed by Engineer-in-Charge. | 60 | Square Metre | 850 ₹51,000 | 850 ₹51,000 | 900 ₹54,000 | 799 ₹47,940 | 850 ₹51,000 | 780 ₹46,800 Lowest | 900 ₹54,000 | 1,100 ₹66,000 | 900 ₹54,000 |
Tender Value
₹49.7 L
EMD Value
₹99,400
Closing Date
29 Aug 2025, 6:00 pmClosed
GE Jammu
GE Jammu c/o 56 APO Pin-900277
CERTAIN SANCTIONED SPECIAL REPAIR AND MINOR WORKS AT DAMANA UNDER GE JAMMU
2025_MES_721703_1
GEJC-53/2025-26
Open Tender
Civil Works
Item Rate
180 days
AoR of GE Jammu
Please refer Tender Documents
8 documents required · 8 mandatory
₹500
GE Jammu
₹99,400
Yes
2 Dec 2025
1 Aug 2025
1 Sept 2025
1 Aug 2025
29 Aug 2025
15 Aug 2025
Amount
B/R Portion: - Demolition of brick work built in cement mortar including all quoins, arches, pillars etc. complete all as specified and as directed.
Material and labour in replacement for brick work with sub class ‘B’ bricks straight or curved on plan exceeding 6 mtr mean radius built in cement mortar (1:6) complete all as specified and as directed.
Demolition of cement concrete (unreinforced) of any description and in any position not otherwise specifically provided for and complete removal of debris outside MOD land complete all as specified and as directed.
Material and labour plain cement concrete (1:2:4) type B-0 (using 12.50mm graded crushed stone aggregate) 25mm thick as in sub base for floor tiles complete all as specified and as directed.
Dismantling floors, hearth or wall tilling including cement mortar bedding (but not backing) removing unserviceable materials outside MOD area and rubbish off the premises complete all as specified and as directed.
Material and labour plain cement concrete (1:4:8) type D-2 (using 40 mm graded crushed stone aggregate) as in foundation, filling and mass concrete, RCC sunken portion as base layer for receiving top layer complete all as specified and as directed by Engineer-in-Charge.
Material and labour for Glass fibre reinforced modified cementitious coating system before the final coat of Latex Shield 2K (or equivalent) in sunken treatment. Base coat : Berger HS Latex plus (or equivalent), Consumption base coat : 0.3 Kg/Sqm, Reinforcement : Glass fiber, Second and Third coat : Latex shield 2K (or equivalent), Consumption top coat : 3 Kg/Sqm, System requirements : density : 2.00 Kg/Ltr, Compressive strength : 0.5 N/Sqmm. (i) Wall penetration through the RCC slab must be sealed using Berger HS Repir (or equivalent). (ii) Intersection of base slab with wall must be provided with a 50 mm fillet using Berger HS Latex plus (or equivalent) modified mortar with a bonding coat of Berger HS Latex plus (or equivalent) modified cement slurry upto 1.5 Mtr. (iii) All depressions, unevenness, surface honeycombing shall be repaired using Berger HS Latex plus (or equivalent) modified polymer mortar with a bonding coat of Berger HS latex plus (or equivalent) modified cement slurry, including cleaning of RCC surface to remove dust, loose particles, etc with compressed air or any other suitable technique depending on site conditions, grinding any sharp edges, etc complete all as specified and as directed.
Material and labour non-skid ceramic tiles 7 to 8 mm thick (square/rectangular) area of each tile exceeding 0.18 Sqm but not exceeding 0.38 Sqm, in floors etc. fixed with approved tile adhesive and provided with 4mm spacer, spacer gaps to be filled with approved epoxy grout complete all as specified and as directed by Engineer-in-Charge.
Material and labour non-skid ceramic tiles 7 to 8 mm thick (square/rectangular) in vertical surface such as skirting, dado etc. fixed with approved tile adhesive and provided with 4mm spacer, spacer gaps to be filled with approved epoxy grout complete all as specified and as directed by Engineer-in-Charge.
Material and labour non-skid ceramic tiles 7 to 8 mm thick (square/rectangular) area of each tile not exceeding 0.18 Sqm, in floors etc. fixed with approved tile adhesive and provided with 4mm spacer, spacer gaps to be filled with approved epoxy grout complete all as specified and as directed by Engineer-in-Charge.
Material and labour glazed ceramic tiles 300 x 450 x 7mm thick on vertical surface such as in skirting, dado etc. fixed with approved tile adhesive and provided with 4mm spacer, spacer gaps to be filled with approved epoxy grout complete all as specified and as directed by Engineer-in-Charge.
Demolition of stone slabs and tiles of any description or thickness in floors/ walls laid bedded and pointed in any mortar etc. complete all as specified and as directed.
Material and labour granite (of any type) 16-20mm thick (tabled rubbed and polished) as in steps, jambs, pillars, window cills, cooking platforms and like in cement mortar (1:4) including pointing in colour cement (1:2) using marble dust with admixture of pigment to match with shade of granite over and including 15mm thick screed bed in cement mortar (1:6) edges of slab to be rounded from all sides (including cutting, wastage and polishing) complete all as specified and as directed.
Taking down chowkhats or frames with shutters (without taking off shutters from the frames) not exceeding 1.5 Sqm each, including cutting holes for taking out holdfasts or dismantling brick work (holes cut and any other damage to jambs, walls for taking out holdfasts shall be finished identical to existing finish without any extra cost to Govt) and removing from site complete all as specified and as directed by Engineer-in-Charge.
Taking down chowkhats or frames with shutters (without taking off shutters from the frames) exceeding 1.5 Sqm and not exceeding 4 Sqm each, including cutting holes for taking out holdfasts or dismantling brick work (holes cut and any other damage to jambs, walls for taking out holdfasts shall be finished identical to existing finish without any extra cost to Govt) and removing from site complete all as specified and as directed by Engineer-in-Charge.
Taking down shutters of any description exceeding 1 Sqm and not exceeding 2 Sqm each complete all as specified and as directed by Engineer-in-Charge.
Material and labour factory made pressed steel frames of size 105 x 60mm made out of PBI sheet 1.25mm thick for doors with one or more rebates including necessary fixing lugs, hinge, lock strike plate etc. complete including bottom of each chowkhat to be welded with 02 no's 25 x 25 x 3mm angle iron projecting 10cm on either side including PCC (1:3:6) type C-0 in back filling of chowkhats and two coats of synthetic enamel paint over one shop coat of zinc chromate primer on all exposed surface complete and one coat of tar on the ends of steel surface in contact with bricks/ concrete surface. Colour/ shade will be approved by Engineer-in-Charge complete all as specified and as directed.
Material and labour factory made pressed steel frames of size 125 x 60mm made out of PBI sheet 1.25mm thick for doors with one or more rebates including necessary fixing lugs, hinge, lock strike plate etc. complete including bottom of each chowkhat to be welded with 02 no's 25 x 25 x 3mm angle iron projecting 10cm on either side including PCC (1:3:6) type C-0 in back filling of chowkhats and two coats of synthetic enamel paint over one shop coat of zinc chromate primer on all exposed surface complete and one coat of tar on the ends of steel surface in contact with bricks/ concrete surface. Colour/ shade will be approved by Engineer-in-Charge complete all as specified and as directed.
Supply and fixing 35mm thick second class hard wood plain framed, panelled shutter (two panel) with lock rail and panel of 9 mm B.W.P. commercial ply or 12 mm veneered particle board with commercial veneering on both faces. The size of rail and stile as per IS : 1003 (Part I), kiln seasoned and chemically pressure treated complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing 35mm thick factory made second class hard wood, glazed and skelton shutter open rebated and prepared to receive glass, guage, etc. (without sash bars), edges of framing plain, chamfered or rounded, fitted with cut and mitred beads for securing glass etc. sizes of members of shutters as specified in SSR 2009 Pt-I Section 8.24 (b) supplied and fitted to chowkhats complete all as specified and as directed.
Material and labour preparation of new wooden surfaces over 10cm width or girth and applying two coats of synthetic enamel paint over one coat of pink primer complete all as specified and as directed.
Supply and fixing pre-painted (factory painted) box type mild steel windows/ Ventilator (factory made) outer frame made out ERW tube 'P' section 65 x 45 x 25 mm and shutter of ERW tube 'P' section 50mm x 35mm x 20mm openable (double shutter) with glazed shutter on external side and gauzed shutter fixed with galvanized mild steel wire cloth 0.56mm nominal dia of wire and average width of aperture 1.18mm including necessary GI wire staples etc on internal side including steel pintel hinges steel handle 100 mm long mild steel tower bolt 02 no's on each shutter stopper of 'Z' section and its locking arrangement and mild steel hook and eyes suitable for fixing cooler/ AC window complete all as specified and shown on drawings No CEPZTD-324/07 Sh 1/3 to 3/3 complete all as directed. Notes: - The quoted rates shall also include: - (i) Two coats of synthetic enamel paint over one shop coat of zinc chromate primer on all exposed surface complete and one coat of tar on the ends of steel surface in contact with bricks/ concrete surface. Colour/ shade will be approved by Engineer-in-Charge. (ii) 4 no's MS steel lugs made of 20 x 5 mm Iron flat 200 mm long. (iii) 10 mm Sq Bar grill/ guard bar design as per drawing. (iv) PCC block for embedding lugs complete. (v) Galvanised mild steel wire cloth, 0.56mm nominal dia of wire and average width of aperture 1.18mm and fixed with tinned tacks, or galvanised wire staples complete. (vi) 3mm thick ordinary glass sheet quality and glazing with oil putty including glazing pins or spring clips.
Supply and fixing factory made single extruded WPC (Wood Polymer Composite) solid door/ window/ Ceosetory windows and other frames/ chowkhat of size 45 x 70 mm (+ 5 mm) comprising of virgin PVC polymer of 'K' value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with mitred joints after applying PVC solvent cement and screwed with full body threaded star headed stainless steel screws having minimum frame density of 750 kg/ cum, screw withdrawal strength of 2200 N (Face) and 1100 N (Edge), minimum compressive strength of 58 N/mm², modules of elasticity 900 N/mm² and resistance to spread of flame of Class 'A' category with property of being termite/ borer proof, water/ moisture proof and fire retardant and fixed in position with mild steel hold fast/ lugs/ stainless steel dash fasteners of required dia and length complete all as specified and as per directions of Engineer-in-Charge.
Supply and fixing 28 to 30mm thick (stile) factory made solid PVC moulded door shutter with wood free EPS with 2, 4 or 6 raised panel design with 2mm thick moulded PVC sheet on the front face and 2mm plain colour PVC sheet on back face, supply and fixing in frame at site as per specifications and drawing shown in SSR complete all as specified and as directed.
Supply and fixing in repairs 18mm thick factory made prelaminated solid PVC board for wardrobe shutter/ kitchen cabinet shutter/ shelves in any colour including PVC edge tape for edging of all around of shutters and exposed faces of same colour complete all as specified and as directed.
Supply and fixing stainless steel auto closing hinges for fixing in kitchen cabinet shutter/ wardrobe shutter with self closing mechanism which allows the cabinet door to close smoothly complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing 100mm hasp and staple, mild steel, wire type, stove enamelled black, including bolt to hinge plate and fixed with screws complete all as specified and as directed.
Supply and fixing butt hinges extruded aluminium alloy with galvanised mild steel hinge pin, anodised 100 mm long complete all as specified and as directed.
Supply and fixing aluminium anodised bow handle fabricated type extruded section of 150mm long complete all as specified and as directed.
Supply and fixing aluminium anodised barrel tower bolts of extruded section 150mm long complete all as specified and as directed.
Supply and fixing 300 mm aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminium alloy and fixed complete all as specified and as directed.
Supply and fixing mild steel helical door spring 300mm including roller and roller plate complete fixed with welding to existing steel chowkhats complete all as specified and as directed.
Supply and fixing 150 mm overall length of cover plate of floor door stopper of aluminium alloy body and tongue, anodised with hard drawn steel spring fixed in floor complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing in repair curtain rods, mild steel, chromium plated with fixing brackets, stops, side finnels etc complete with all fittings complete all as specified and as directed.
Supply and fixing galvanised mild steel wire cloth, 0.56mm nominal dia of wire and average width of aperture 1.18mm and fixed with tinned tacks, or galvanised wire staples complete all as specified and as directed.
Dismantling PVC water tank/ demolition of RCC water storage tanks of capacity exceeding 250 but not exceeding 500 litres and removing from site complete all as specified and as directed.
Supply and fixing rotational moulded polyethylene water storage tanks 500 litres capacity (cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Part - I, including 20mm ball valves, 20mm tank nipple complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing in repairs 25mm outer dia CPVC gate valves complete all as specified and as directed by Engineer-in-Charge.
Taking up or down steel tubing with connections for cleaning for refixing or removing or storeyard complete of bore 15mm complete all as specified and as directed.
Taking up or down steel tubing with connections for cleaning for refixing or removing or storeyard complete of bore 20mm complete all as specified and as directed.
Supplying and laying of 20mm outer dia CPVC pipes SDR 11 and Plain CPVC SDR 11 fittings on concealed in wall and ceiling or laid in floor complete with all fittings (such as bends, elbows, Tee short pieces, connectors, back nuts, diminishing pieces, caps and plugs, unions etc.) complete all as specified and as directed.
Supplying and laying of 25mm outer dia CPVC pipes SDR 11 and Plain CPVC SDR 11 fittings on concealed in wall and ceiling or laid in floor complete with all fittings (such as bends, elbows, Tee short pieces, connectors, back nuts, diminishing pieces, caps and plugs, unions etc.) complete all as specified and as directed.
Supply and fixing in repairs stainless steel sink with drainage board made out of 1.00mm thick sheet for kitchen with plug, washers, waste pipe, connecting union overall size 915mm x 460mm with bowl size 410mm x 330mm x 160mm including 32mm bore PTMT waste coupling, fixing in cement mortar onto dwarf wall or fixing cantilever brackets complete all as specified and as directed.
Supply and fixing in repairs stainless steel plate rack of size 750 x 600 x 250mm of size having partition as per sample kept in AGE B/R office and fixed with steel fasteners or steel screwed complete all as specified and as directed.
Supply and fixing in repairs vitreous china wash down water closet (pedestal pattern) white (excluding flushing cistern and flush pipe) including PVC seat cover white closed pattern with recessed bottom and connection to drain or outgoing pipe and flushing pipe complete all as specified and as directed.
Supply and fixing in repairs 10 litres capacity PVC low level flushing cistern including 32mm dia PVC flush pipe, fixing in position with PVC connection pipe of 15mm x 450mm long etc complete all as specified and as directed.
Supply and fixing in repairs Vitreous china wall hang corner wash hand basin, size 400 x 400 x 195mm including 32mm bore PTMT waste coupling, waste pipe and PVC connection pipe of 15mm x 450mm long complete all as specified and as directed. Make: - Cera, Cat Part No : S2040161 or equivalent in makes as specified in Group - 1 of Appx 'F'.
Supply and fixing in repairs 15mm bore chromium plated cast copper alloy bib taps fancy type with crutch or butterfly handle screwed down, screwed for iron pipe or for brass ferrule complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing in repairs 15mm bore chromium plated wall mixer with bend pipe for overhead shower pipe for mixing hot and cold water with connecting legs and wall flanges screwed down for iron pipe and fixed complete all as specified and as directed. Make: - Cera Cat Part No : F2006402 or equivalent in makes as specified in Group - 1 of Appx 'F'.
Supply and fixing in repairs 15mm bore chromium plated basin/ sink mixer for mixing hot and cold water screwed down for iron pipe complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing in repairs 15mm dia angle/ stop cock of chromium plated, glossy finish complete all as specified and as directed.
Supply and fixing in repairs brass chromium plated shower rose 125mm size with or without swivel joints any size including fixing to steel pipe of 15mm bore complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing in repairs health faucet (ABS body) mild steel chromium plated suitable for 15 mm dia pipe with 1.25 metre long flexible tube and ABS wall hook including making connections and fixed in position complete in all respect all as specified and as directed.
Supply and fixing in repairs tubular towel rail 20mm dia 'D' type 60cm long between flanges chromium plated complete all as specified and as directed.
Material and labour in repairs PVC (SWR) floor trap 75mm dia plain with grating including jointing with solvent cement etc complete all as specified and as directed.
Supply and fixing in repairs 110mm dia PVC (SWR) pipes single socketed in any length with rubber joints fixed to walls/ floor etc complete all as specified and as directed.
Supply and fixing in repairs 75mm dia PVC (SWR) pipes single socketed in any length with rubber joints fixed to walls/ floor etc complete all as specified and as directed.
Supply and fixing in repairs PVC (SWR) bends/ single Tee/ Y 110mm dia any radius with access door complete all as specified and as directed.
Supply and fixing in repairs PVC (SWR) bends/ single Tee / Y 75 mm dia any radius with access door complete all as specified and as directed.
Supply and fixing in repairs PVC (SWR) vent cowl 110mm bore complete all as specified and as directed.
Supply and fixing in repairs PVC (SWR) vent cowl 75mm bore complete all as specified and as directed.
Taking down cement plaster of any description on brick walls, concrete surfaces including racking out joints, hacking for key, scrubbing down with water, etc. complete removal of debris outside MOD land (including all necessary scaffolding, lifting arrangement upto 12 mtr height) complete all as specified and as directed.
Material and labour rendering 5mm thick on fair faces of concrete surface of ceiling in cement mortar (1:3) surface finished even and smooth surface without using extra cement complete all as specified and as directed.
Material and labour rendering 10mm thick on fair faces of brick work or concrete surface in cement mortar (1:6) surface finished even and smooth without using extra cement complete all as specified and as directed.
Material and labour rendering 15mm thick in cement mortar (1:4) on fair faces of brick surface finished even and fair including water proofing compound (including all necessary scaffolding, lifting arrangement upto 12 mtr height) complete all as specified and as directed.
Material and labour Capillary rise treatment of walls, Base coat : Berger HS Latex plus (or equivalent), Consumption base coat : 0.3 Kg/Sqm, Second and Third coat : Latex shield 2K (or equivalent), Consumption top coat : 3 Kg/Sqm, System requirements : density : 2.00 Kg/Ltr, Compressive strength : 0.5 N/Sqmm complete all as specified and as directed.
Material and labour preparing of new plastered surface of ceiling and applying two coats of distemper oil bound over primer coat complete all as specified and as directed by Engineer-in-Charge.
Material and labour complete removal of existing treatment and preparation of ceiling and applying two coats of distemper oil bound over primer coat complete all as specified and as directed by Engineer-in-Charge.
Material and labour preparing of new plastered surface of wall and applying wall care putty and applying two coats of distemper oil bound over primer coat complete all as specified and as directed by Engineer-in-Charge.
Material and labour complete removal of existing treatment and preparation of surface and applying wall care putty on old surface of walls and applying two coats of distemper oil bound over primer coat complete all as specified and as directed by Engineer-in-Charge.
Material and labour preparing of new plastered surface of wall surface and applying exterior wall care putty and acrylic smooth exterior paint of required shade (Two coats over and including priming coat of exterior primer applied as per manufacturer's instructions) (including all necessary scaffolding, lifting arrangement upto 12 mtr height) complete all as specified and as directed.
Material and labour complete removal of existing treatment on wall/ ceiling surface and applying exterior wall care putty and acrylic smooth exterior paint of required shade (Two coats over and including priming coat of exterior primer applied as per manufacturer's instructions) (including all necessary scaffolding, lifting arrangement upto 12 mtr height) complete all as specified and as directed.
Removing existing treatment from roof surfaces such as tiling, tarfelt, fungus, moss, dust etc., cleaning the surface of all foreign material by wire brushing and dusting and racking out RCC slab complete all as specified and as directed and removing the debris outside defence land.
Material and labour cleaning of the exposed concrete slab and repairing the surface irregularities like cracks, potholes, as per manufacturer's method statement by Berger HS Rapairo (or equivalent) along with HS Latex Plus (or equivalent) and cement in mixing ratio of (1:4) where ever required complete all as specified and as directed.
Material and labour providing cement concrete (1:2:4) type B-0 (using 12.5 mm graded crushed stone aggregate) in roof padding, roof kerbs or mud stops, rounded or chamfered on edges complete all as specified and as directed.
Material and labour Home Shield PU Roofkoat (or equivalent) is a one component liquid, solvent free, cold applied, waterproofing membrane that is highly elastic and UV resistant with 10 years Warranty. ASTM D 6083-97a waterproofing and heat reflecting system having following key performance properties. (i) UV resistant, prevent yellowing and weathering. (ii) Highly elastic upto 350% and crack bridging. (iii) Excellent adhesion on porous and non-porous substrates. (iv) Tensile Strength >10 N/Sqmm with GeoTextile fleece. (v) Solar Reflective Index (SRI) more than 109-111 ASTM E1980-11. System : First coat : Providing and applying primer over the prepared surface with HS PU roofkoat Primer (or equivalent), Coverage : 0.2Kg/Sqm (with 50% dilution of water), Reinforcement : Geotextile 40 gsm, Second coat : Home shield roofkoat (or equivalent), Consumption : 0.5 Kg/Sqm, Third coat : HS PU roofkoat (or equivalent), Consumption : 0.8 Kg/Sqm. System buildup - 1.5Kg/Sqm with geotextile of 40 gsm complete all as specified and as directed.
Material and labour PCC 75mm thick (1:3:6) type C-2 (using 40mm graded crushed stone aggregate) in plinth protection/ path/ Hardstanding finished even and fair complete all as specified and as directed.
Surface excavation not exceeding 30 cm deep and averaging 15cm deep and getting out in soft/ loose soil complete all as specified and as directed.
Excavating in trenches not exceeding 1.5 metre wide and not exceeding 1.5 metre in depth and not exceeding 10 Sqm on plan in any type of soil and getting out complete all as specified and as directed.
Returning, filling in (soil) including spreading, levelling, watering and well ramming in layers not exceeding 25 cm thick in any type of soil complete all as specified and as directed.
Removal of excavated material (soil) to a distance not exceeding 50 metre and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified and as directed.
Material and labour for 75mm thick cement concrete in base and mass concrete (1:4:8) type D-2 (using 40mm graded crushed stone aggregate) complete all as specified and as directed.
Material and labour for brick work with sub class ‘B’ bricks straight or curved on plan exceeding 6 mtr mean radius built in cement mortar (1:6) complete all as specified and as directed.
Material and labour for applying two coats of cement based paint including preparation of new plastered surface complete all as specified and as directed.
Material and labour for providing and laying 60mm thick factory made chamfered edge cement concrete paver block of M-35 grade with approved colour, design and pattern as in footpath, parks, lawns, drive ways or light traffic parking etc., of required strength, thickness and size/ shape, made by table vibratory method using PU mould, laid in required colour and pattern over and including 50mm thick compacted bed of fine sand, compacting and proper embedding/ laying of interlocking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand complete all as specified and as directed.
Material and labour plain cement concrete (1:5:10) type E-2 (using 40mm graded crushed stone aggrregate) in foundations, filling and mass concrete complete all as specified and as directed.
Material and labour for providing and laying at or near ground level factory made kerb stone of M-25 grade cement concrete in position to the required line, level and curvature, jointed with cement mortar (1:3) (1 cement : 3 coarse sand), including making joints with or without grooves thickness of joints except at sharp curve shall not to more than 5 mm, including making drainage opening wherever required complete all as specified and as directed.
E/M Portion: - Taking down old unserviceable copper/ aluminium point wiring concealed/ batten (light, fan, socket or power) complete, including fixtures and fittings such as switches, sockets, ceiling roses, bell push, bell electric, lamp holder, bulk head fitting, pendants, regulators, sockets and any type of switch board wooden/ iron, round block etc removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc complete all as specified and as directed.
Taking down carefully unserviceable TPN DB's/ MCB DB's of any type/ size with MCB's and disconnecting and making good disturbed surfaces complete all as specified and as directed.
Material and labour in replacement for sub main wiring with proper colour coding, insulated, unsheathed, multistranded, copper conductor FRLS, cable of 2 run 6 Sqmm for phase and neutral and one run of 4.0 Sqmm for earth wire unsheathed, multistranded, copper conductor FRLS, drawn through the existing rigid PVC concealed conduit fixed on wall. Two runs of cable for phase/ neutral and one run of cable for earth will be measured and paid as one unit length including taking down old wiring complete all as specified and as directed. Note: - Wiring shall be done in proper colour coding.
Material and labour for complete point wiring with 1.5 Sqmm two single core multistranded copper conductor FRLS insulated and unsheathed heavy duty cable in colour code including continuous earth wire with cable of size 1.5 Sqmm copper conductor flexible FRLS insulated drawn in and including concealed PVC rigid conduit medium grade ISI marked after cutting chases in wall, plastering after concealing conduit, including modular galvanised flush boxes of suitable size and white cover plate with frame as per relevant IS for mounting modular switches, sockets, fan regulators etc and including making good the disturbed surface as per existing complete all as specified and as directed by Engineer-in-Charge for the following: -
Description all as per Ser item No 92.00 here-in-before but for multi 5 pin 5 amp socket outlet on same board ISI marked complete all as specified and as directed.
Description all as per Ser item No 92.00 here-in-before but for multi 5 pin socket outlet 5 amp socket on independent board ISI marked complete all as specified and as directed.
Description all as per Ser item No 92.00 here-in-before but for one bell/ buzzer point controlled by one push button on the same board with other switches or independent with cable 1.5 Sqmm size complete all as specified and as directed.
Description all as per Ser item No 92.00 here-in-before but for multi 6 pin 15 Amp socket outlet independent controlled by 15 Amp switch with 2.5 Sqmm copper conductor multistranded cable PVC insulated FRLS and unsheathed cable in and including PVC rigid concealed conduit 20/25 mm dia and unsheathed copper conductor multistranded cable 2.5 Sqmm as earth wire FRLS PVC insulated in green color complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing for modular socket, 6A - 5 pin combined 2 module, 240 volts ISI marked complete all as specified and as directed.
Supply and fixing for modular switch 1 module 6A, 1 module, 240 volts ISI marked complete all as specified and as directed.
Supply and fixing for modular bell push 6A, 1 module, 240 volts ISI marked complete all as specified and as directed.
Supply and fixing for ceiling rose, 3 Pin/PVC/polycarbonate isolated body ISI marked complete all as specified and as directed.
Supply and fixing for modular switch 1 way 16A, 1 module, 240 volts ISI marked complete all as specified and as directed.
Supply and fixing for modular socket 6A/16A - 6 pin combined 2 module, 240 volts ISI marked complete all as specified and as directed.
Supply and fixing for Calling bell Ding Dong AC 230 Volts, single pole ISI marked complete all as specified and as directed.
Material and labour for lamp holder, PVC/Polycarbonate type with back plate suitable for batten fittings complete all as specified and as directed.
Material and labour for self ballast LED retrofit lamp with PVC body and PC Diffuser 9 watt 230 Volt 6500K complete all as specified and as directed.
Supply and fixing in replacement LED lights fitting 1 x 20W, 220V, AC decorative box type complete with LED tube rod 18 watts driver, holder and power factor >0.9, 100 Lumen/Watt, 6500 K cool day type conforming to ISI including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and as directed.
Supply and fixing of vertical distribution board (V.TP&N) 4 way double door suitable for TPN 4 pole 125 Amp 16 KA four pole as incomer, it should be IP-43 protected with copper bus bars, neutral links, Earthing bar complete all as specified and as directed.
Material and labour for replacement distribution board sheet steel powder coated for MCB with copper bus bar and neutral link earthing stud SPN 8 way 240 volts double door complete all as specified and as directed by Engineer-in-Charge. Note: - Distribution board and MCB's should be of same make.
Supply and fixing of SPN 40 to 63 Amp rating 240V, 10 KA 'B' curve miniature circuit breaker (MCB) of following poles and current carrying capacity in the MCB distribution board complete with connection, testing and commissioning complete all as specified and as directed.
Supply and fixing of 240V, 10 KA 'B' curve miniature circuit breaker (MCB) of single pole and current carrying capacity 6 to 32 Amp complete with connection, testing and commissioning complete all as specified and as directed.
Material and labour for Earthing complete with galvanised mild steel earth plate electrode of size 600 x 600 x 6mm thick burried directly in ground earth (in vertical) earth pit not less than 2.25 mtr deep below normal ground level with top edge of the earth plate not less than 1.5 mtr below ground level connected to galvanised iron or earth lead wire 4mm dia (8 SWG) by means of nut, bolt, check nuts and washer of galvanised iron including PCC pit in PCC (1:2:4) type B-1 pre-cast RCC cover slab using reinforcement with suitable handle made of round bar, including necessary excavation and earth work in any type of soil, 20mm dia medium grade galvanised steel tube for watering with one end fixed with cast iron funnel and wire mesh 15mm dia bore light grade galvanised steel tubing upto 5 m length for drawing earth lead wire protection, common salt, charcoal, etc complete all as shown in electrical plate No 3 of SSR Part-I and testing on completion all as specified and as directed.
Supply and fixing of LED light fitting 10W bulk head luminaires including LED light driver holder connecting up with three core flexible copper conductor cable of suitable size complete all as specified and as directed.
Supply and fixing in replacement LED street light fitting 35 Watt 230 V AC outdoor type with high pressure die cast aluminium housing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP-65/66 protection complete all as specified and as directed.
Supply and fixing in replacement 415V 10 KA 'B' curve miniature circuit breaker (MCB) TPN 4 Pole, upto 125 Amps of following poles and current carrying capacity in the distribution board complete with connection, testing and commissioning complete all as specified and as directed.
Supply and fixing of fan step regulator, 100W - 1 module 240 volts ISI marked complete all as specified and as directed.
Disconnecting and taking out defective underground cable any size and any type from roof, pole, pipe, floor, wall etc complete all as specified and as directed.
Supply and laying, connecting and testing XLPE underground cable insulated and overall sheathed with aluminium conductor heavy duty 1100 volts grade 16 Sqmm 4.0 core laid in trenches/ on poles/ road crossing or passing through existing/new pipe under road crossing, clamping on wall etc. complete all as specified and as directed. Notes: - (i) Earth work, sand, bricks, removing, returning filling aluminium thimbles/lugs will be paid separately. (ii) Cost of laying electrical cable through new/existing pipe under road, buildings, railway tracks, highways are included in the quoted rates. (iii) All equipments, machinery or tools if required for laying electrical cable through new/existing pipes are provided by the contractor without any extra cost.
kerni electricals (BID ID -3410354)
M/s Koul & Sons (BID ID -3410356)
Hare krishna engineering const. (BID ID -3402413)
M/S IMTESH BHAT (BID ID -3402793)
M/S TRIKUTA BUILDERS (BID ID -3409097)
Mehta Enterprises (BID ID -3402450)
SHARMA CONSTRUCTION COMPANY (BID ID -3402494)
M/S ELECTROMATICS (BID ID -3402921)
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .