At DBWS-Electrical work in connection with Upgradation of infrastructure for augmentation of maintenance facilities in Workshop
EL1DBW1-Infra-25-26-92RT2
EL1DBW1-Infra-25-26-92RT2
Open
12 Months
Unknown (Unspecified Location)
₹0
₹1.1 L
1 Jul 2026
1 Jul 2026
8 Jul 2026
storied) and open sheds for LCR work and water tank testing of CBS
Item- 1 Proposed Double storied godown and office (30M x 10.5M)
S No. Item Description of Item Unit Qty Rate Amount
1 1 Supply, installation, testing and commissioning of Numbers 42.00 727.10 30538.20
20W LED tube light
2 2 Supply, installation, testing and commissioning of Numbers 20.00 5029.20 100584.00
BLDC wall fan 400 mm sweep
3 3 Supply, installation, testing and commissioning of Numbers 15.00 3225.20 48378.00
BLDC exhaust fan, 200 mm sweep
commissioning of Cable PVC/XLPE insulated
copper conductor HRFR, 4 sq. Mm single core
5 5 Supply, laying/binding, testing and Metre 210.00 1400.30 294063.00
commissioning of Cable PVC/XLPE insulated
copper conductor unarmoured 35 sq. mm. Single
core ( FOR MAIN CIRCUIT) (P+N),
6 6 Supply & Wiring of light point concealed type Numbers 56.00 400.45 22425.20
through wall by single core PVC insulated
1.5sq.mm Copper wire 1.1 KV Grade confirming is
694/1990 Concealed through Medium Gauge PVC
conduit pipe of suitable size including Modular
switch 6A, Cover & plate & MS concealed box with
ceiling rose/ Angle holder and all accessories.
7 7 Supply & Wiring for Fan point (ceiling fan/ Numbers 53.00 473.61 25101.33
exhaust fan/wall fan) concealed type through
Wall by Single core PVC insulated Wall by Single
core PVC insulated 1.5sq.mm copper wire 1.1 KV
confirming is 694/1990 concealed through
medium grade PVC conduit pipe with 1.0sq.mm
copper earthing wire earth continuity including
modular switch & Socket 6AMPS with cover plate
& MS Concealed box with all accessories and
8 8 Supply & Wiring of 6 AMPS Plug/socket point Numbers 37.00 924.12 34192.44
concealed type by single core PVC insulated
4sq.mm. PVC cable 1.1 KV grade is 694/1990
Concealed through medium gauge PVC conduit
pipe with earth continuity PVC copper wire
2.5sq.mm including modular socket & switch 6A
installed on M.S. Concealed box with Plate and
9 9 Supply, installation, testing and commissioning of Numbers 9.00 3609.59 32486.31
8-way circuit distribution board comprising 08
nos. Of SP MCB of 10 Amps. with complete
10 10 Supply, installation, testing and commissioning of Numbers 7.00 1755.96 12291.72
MCB 4-pole 63Amps. With SS enclosure
11 11 Supply, installation, testing & commissioning of Numbers 1.00 149857.47 149857.47
SDB with 3 phase electronic energy meter, digital
Ampere meter with CT, selector switch, suitable
digital voltmeter & LED indicator lamp with
following incoming and outgoing- incoming:
MCCB 4 Pole, 250A, 36kA=01 no. Outgoing: MCCB
4 pole, 125A, 36kA=03 nos, MCCB 4 pole, 100A,
36kA=03 nos, MCB TPN 40A, 10Ka-02 Nos.
CW-SHOP-CWM-ELECTRICAL/N F RLY
12 12 Supply, erection, testing and commissioning of 50 Numbers 10.00 1132.71 11327.10
mm dia. 3 mtr. Long G.I. Pipe (medium gauge,
Tata/Zindal make) earth electrode, complete with
06 SWG G.I. Earth wire and G.I. Nut, bolts, washer
etc. including supply of materials for construction
of suitable masonry earth pit and provision of
alternate layer of salt and charcoal. (earth
electrode to be erected by digging of earth pit.)
13 13 Supply, fitting/fixing, testing and commissioning Metre 250.00 105.72 26430.00
of Earth Bus with (32x6) mm G.I. Flat including
suitable mounting arrangement and connection
upto earth electrode. Provision of 12mm dia.
Holes to be made on earth bus, as per site
requirement, for earth connection.
14 14 Supply, installation, testing and commissioning of Numbers 1.00 17701.21 17701.21
200A MCCB 4-pole with enclosure and
15 15 Supply, laying/binding, testing and Metre 50.00 9872.50 493625.00
commissioning of Cable PVC/XLPE insulated
copper conductor unarmoured 70 sq. Mm. 4-core
(From Panel at ground floor to MCCB)
16 16 Supply, installation, testing and commissioning of Numbers 14.00 1975.01 27650.14
2' X 2' LED panel light (on ceiling)
17 17 Supply, installation, testing and commissioning of Numbers 14.00 5126.00 71764.00
BLDC ceiling fan 1200 mm sweep with all
18 18 Supply & Wiring of 16 AMPS Plug/socket point Numbers 11.00 924.12 10165.32
concealed type by single core PVC insulated
4sq.mm. PVC cable 1.1 KV grade is 694/1990
Concealed through medium gauge PVC conduit
pipe with earth continuity PVC copper wire
2.5sq.mm including modular socket & switch 16A
installed on M.S. Concealed box with Plate and
19 19 Supply and wiring of concealed wiring of Air Numbers 4.00 1155.15 4620.60
Conditioner Point for 1.5/2 TON Capacity by
4sq.mm Copper wire through PVC Pipe (M) and
Earthing continuity by 1.5 sq.mm copper cable
with 16 Amps Modular Socket and 25Amps Single
phase starter with concealed box,cover,plate,as
20 20 Supply, laying/ binding, and commissioing of Metre 550.00 118.80 65340.00
Cable HRFR PVC insulated copper conductor 6 sq.
Mm. Single core (For SUB-MAINS) (P+N)
21 21 Supply, laying/ binding, and commissioing of Metre 800.00 15.76 12608.00
Cable FR PVC insulated copper conductor 0.75 sq.
Mm (For EARTHING)
22 22 Supply, laying/ binding, and commissioing of Metre 120.00 668.80 80256.00
Cable XLPE/ PVC insulated copper conductor 16
sq. Mm single core (For MAIN CIRCUIT) (P+N))
23 23 Supply, installation, testing and commissioning of Numbers 6.00 1570.77 9424.62
30W LED flood light with mounting bracket
Item- 2 PROPOSED SHED FOR WATER TANK TESTING & REPAIRING (10.5M X 5.6M)
S No. Item Description of Item Unit Qty Rate Amount
1 1 Supply, installation, testing and commissioning of Numbers 3.00 12584.67 37754.01
125A MCCB 4-pole with SS enclosure and
2 2 Supply, installation, testing and commissioning of Numbers 6.00 3514.41 21086.46
100W LED flood light with mounting bracket
CW-SHOP-CWM-ELECTRICAL/N F RLY
3 3 Supply, installation, testing and commissioning of Numbers 6.00 5973.14 35838.84
600 mm sweep energy efficient Air Circulator,
wall/pillar mounted type complete with sturdy
mounting arrangement, 01 no. 16A flush type
switch, 01 no. 16A flush type 5-pin socket, 02
(two) MS board with hylum / mica sheet top (for
switch & socket) , 19 mm dia. 2.00 mm thich PVC
pipe (for drawing of 2.5 sq. mm single core cable)
with (25x5) mm MS clamp (02 no. per metre) with
nut & bolts (for fixing of PVC pipe), 16 SWG bare
copper earth continuity conductor etc.
4 4 Supply, installation, testing & commissioning of Numbers 6.00 7781.83 46690.98
Heavy duty Industrial metal Plug & Socket, 63
Amps. 415 V DS-5-pin, (with integral Switching
device), MCCB & SS enclosure with pre-wired
including all accessories.
5 5 Supply, installation, testing & commissioning of Numbers 6.00 4612.13 27672.78
Heavy duty Industrial metal Plug & Socket, 32
Amps. 415 V DS-5-pin, (with integral Switching
device), MCB & SS enclosure with pre-wired
including all accessories.
6 6 Supply, installation, testing & commissioning of Numbers 6.00 762.81 4576.86
SP&N Enclosure with 2-pole and Earth, 20A metal
Plug & Socket for incorporating 20A SPN MCB
with all accessories.
7 7 Supply, installation, testing & commissioning of Numbers 1.00 147740.00 147740.00
Pillar / wall mounted 3-phase Battery Charger.
Input : 415 VAC (3-phase). Output: 110 VDC.
Capacity: 40 Amps. Including fabricated frame as
8 8 Supply, installation, testing & commissioning of Numbers 1.00 3029.66 3029.66
DOL Starter 5 HP/3.7KW , 20A, overload relay
range(A): 7.5-11 (FOR WATER PUMP)
9 9 Supply, installation, testing & commissioning of Numbers 2.00 1406.02 2812.04
32A MCB 2-pole with SS enclosure (FOR PUMP)
10 10 Supply, laying/ binding and commissioning of Metre 100.00 1400.30 140030.00
Cable PVC/XLPE insulated copper conductor
unarmoured 35 sq. Mm.single core (FOR MAINS)
11 11 Supply, fitting/fixing of support Bracket for Power Set 4.00 302.02 1208.08
Circuit complete with all accessories suitable
shapped and fabricated with GI strip and GI rod,
to fastening on pillar comprising of 04 nos. LT
insulators (Sackle/Reel) of size : 75 mm x 90 mm
light gauge GI pipe pieces to be placed in
between the insulators and two edges of the
bracket to prevent movement of the insulators.
12 12 Supply, fitting/fixing of support Bracket for Set 4.00 151.00 604.00
Lighting Circuit complete with all accessories
suitable shapped and fabricated with GI strip and
GI rod, to fastening on roof truss, comprising of
02 nos. LT insulators (Sackle/ Reel) of size : 75
mm x 90 mm light gauge GI pipe pieces to be
placed in between the insulators and two edges
of the bracket to prevent movement of the
13 13 Supply, laying/ binding, commssioning of 50 sq. Metre 90.00 1922.80 173052.00
Mm. Copper conductor XLPE/ PVC insulated
unarmoured single core (12M x 4L x 2 side) MTR.
(3P+1N) (POWER CIRCUIT)
14 14 Supply, laying/ binding, commssioning of 35 sq. Metre 48.00 1400.30 67214.40
Mm. Cable copper conductor PVC/XPLE insulated
unarmoured single core (1P+1N) (12M x 2L x 2
sides) MTR. (FAN CIRCUIT)
15 15 Supply, laying/ binding, commssioning of 16 sq. Metre 24.00 668.80 16051.20
Mm. Cable copper conductor PVC/XPLE insulated
unarmoured single core (LIGHT CIRCUIT) (1P+1N)
CW-SHOP-CWM-ELECTRICAL/N F RLY
16 16 Supply, laying/binding, testing and Metre 50.00 79.95 3997.50
commissioning of Cable PVC/XLPE insulated
copper conductor HRFR, 4 sq. Mm single core (For
earthing of Power Circuit)
17 17 Supply, laying/binding, testing and Metre 50.00 32.70 1635.00
commissioning of Cable PVC/XLPE insulated
copper conductor HRFR, 1.5 sq. Mm single core
(For earthing of Light & Fan Circuit)
Item- 3 PROPOSED OPEN SHED FOR LCR WORKS (10.5M X 8.5M)
S No. Item Description of Item Unit Qty Rate Amount
1 1 Supply, fitting/fixing, commissioning of PVC Metre 200.00 136.47 27294.00
Conduit pipe (Heavy duty), 50 mm dia. complete
with all accessories.
2 2 Supply, installation, testing and commissioning of Numbers 6.00 3514.41 21086.46
100W LED FLOOD LIGHT with mounting bracket
3 3 Supply, installation, testing and commissioning of Numbers 6.00 5973.14 35838.84
600 mm sweep energy efficient Air Circulator,
wall/pillar mounted type complete with sturdy
mounting arrangement, 01 no. 16A flush type
switch, 01 no. 16A flush type 5-pin socket, 02
(two) MS board with hylum / mica sheet top (for
switch & socket) , 19 mm dia. 2.00 mm thich PVC
pipe (for drawing of 2.5 sq. mm single core cable)
with (25x5) mm MS clamp (02 no. per metre) with
nut & bolts (for fixing of PVC pipe), 16 SWG bare
copper earth continuity conductor etc.
4 4 Supply, installation, testing & commissioning of Numbers 6.00 7781.83 46690.98
Heavy duty Industrial Plug & Socket, 63 Amps.
415 V DS-5-pin, (with integral Switching device),
MCCB & SS enclosure with pre-wired including all
5 5 Supply, installation, testing & commissioning of Numbers 6.00 4612.13 27672.78
Heavy duty Industrial Plug & Socket, 32 Amps.
415 V DS-5-pin, (with integral Switching device),
MCB & SS enclosure with pre-wired including all
6 6 Supply, installation, testing & commissioning of Numbers 6.00 762.81 4576.86
SP&N Enclosure with 2-pole and Earth, 20A metal
Plug & Socket for incorporating 20A SPN MCB
with all accessories.
7 7 Supply, installation, testing & commissioning of Numbers 2.00 1406.02 2812.04
32A MCB 2-pole with SS enclosure (For Pump)
8 8 Supply, laying/ binding and commissioning of Metre 100.00 1400.30 140030.00
Cable PVC/XLPE insulated copper conductor
unarmoured 35 sq. Mm.single core (FOR MAINS)
9 9 Supply, laying/ binding, commssioning of 50 sq. Metre 85.00 1922.80 163438.00
Mm. Copper conductor XLPE/ PVC insulated
unarmoured single core (12M x 4L x 2 side) MTR.
(3P+1N) (POWER CIRCUIT)
10 10 Supply, laying/ binding, commssioning of 35 sq. Metre 48.00 1400.30 67214.40
Mm. Cable copper conductor PVC/XPLE insulated
unarmoured single core (1P+1N) (12M x 2L x 2
sides) MTR. (FAN CIRCUIT)
11 11 Supply, laying/ binding, commssioning of 16 sq. Metre 24.00 668.80 16051.20
Mm. Cable copper conductor PVC/XPLE insulated
unarmoured single core (LIGHT CIRCUIT) (1P+1N)
12 12 Supply, laying/binding, testing and Metre 50.00 79.95 3997.50
commissioning of Cable PVC/XLPE insulated
copper conductor HRFR, 4 sq. Mm single core (For
earthing of Power Circuit)
13 13 Supply, laying/binding, testing and Metre 50.00 32.70 1635.00
commissioning of Cable PVC/XLPE insulated
copper conductor HRFR 1.5 sq. Mm. Single core
(for Earthing of Light & Fan circuit)
CW-SHOP-CWM-ELECTRICAL/N F RLY
14 14 Supply, fitting/fixing of support Bracket for Power Set 4.00 332.22 1328.88
Circuit complete with all accessories suitable
shapped and fabricated with GI strip and GI rod,
to fastening on pillar comprising of 04 nos. LT
insulators (Sackle/Reel) of size : 75 mm x 90 mm
light gauge GI pipe pieces to be placed in
between the insulators and two edges of the
bracket to prevent movement of the insulators.
15 15 Supply, fitting/fixing of support Bracket for Set 4.00 166.11 664.44
Lighting Circuit complete with all accessories
suitable shapped and fabricated with GI strip and
GI rod, to fastening on roof truss, comprising of
02 nos. LT insulators (Sackle/ Reel) of size : 75
mm x 90 mm light gauge GI pipe pieces to be
placed in between the insulators and two edges
of the bracket to prevent movement of the
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
HTML
nit.pdf
NIT
TenderDocumentRT2Infra.pdf
ATTACHMENT
RBletterLabourlawprovision.pdf Labour Law Provisions
ATTACHMENT
RBletterLabourlawprovision.pdf
ATTACHMENT
Download all tender documents and submit your bid