Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹22.2 CrAccepted-AOC 81 ARYA NAGAR ASSANDH ROAD PANIPAT HARYANA 132103 | PANIPAT | HARYANA | 132103 | ₹22.2 Cr Quoted ₹22.4 Cr | 1 | Accepted-AOC Awarded due to L1 |
| 2 | 2₹23.9 CrRejected-AOC 81 ARYA NAGAR ASSANDH ROAD PANIPAT HARYANA 132103 | PANIPAT | HARYANA | 132103 | ₹23.9 Cr | 2 | Rejected-AOC Rejected due to L-2 |
Tender Value
₹20.8 Cr
EMD Value
₹41.6 L
Closing Date
21 Jan 2025, 3:00 pmClosed
AMAN Mor
Bahadurgarh PHED
18 MLD STP Bahadurgarh Town DNIT for Rehabilitation of Existing MPS and Grit Channel, Const. of CC Path around all new structures and interconnecting all old structures, Const. of 1 No Circular RCC Tank with Walkway and Stairs 9 m Dia with 3m (Recall
2025_HRY_423531_1
20254E640F53 8C65 4703 A3FB D6BB1B272575593PUH
Open Tender
Civil Works
548 days
Bahadurgarh
Eligibility Criteria as per approved DNIT.
3 documents required · 3 mandatory
₹20,000
₹41.6 L
Yes
30 Jul 2025
14 Jan 2025
21 Jan 2025
14 Jan 2025
21 Jan 2025
14 Jan 2025
Amount
Chlorine toners with rail arrangement 900 Kg
Crane arrangement with guide rails for lifting and lowering of Toners
Providing and Installation of Sluice Valves of 450 mm for Byepass arrangement
Office Furniture
Providing and Installation of RAS Pumps 190m3/H @ 12 MWC (2W plus 2S)
Providing and Installation of Two no Mechanical Coarse screen at MPS and removal of One No Non functional Mechanical screen with Belt Conveyor removal mechanism of 20 mm spacing . Including Panels and Cables of required thickness and length
Re Installation after cleaning of Bio gas Domes and replacement of 2 inch gas pipe with clamp
Providing and Installation of two No. Mechanical Fine screen of 6mm spacing with specifications as per DNIT of 700mm x 900mm and removal existing one no mechanical dysfuntional fine screen. The screen shall be equipped with conveyor and arrangement of screenings to be automatically removed including Panels and Cables of required size.
FRP Feed Boxes to be supplied and Installed new with 8 feeder pipes each feed box in all three reactors 6b in each reactor
Raisin Paint on all FRP Gas Pipes
Credit for old 5 Nos.Raw Sewage pumps, Non Clog submersible with all specials 8000 LPM x 18.00 M x 55.00 BHP Weight of each Pump = 700 Kg. Rate of Scrap = 60/- Kg. Total weight of 5 Pumps 5 x 700 = 3500 Kg. Total cost of scraped pumps 3500 x 60 = Rs. 210000/-
NON CLOG SUBMERSIBLE PUMPING SET FOR SEWERAGE: Supplying, erection, testing and commissioning of submersible motor pumping set non clog for sewerage having head 18.00 m as per the indicated requirements of discharge in LPM and power capacity in BHP as per IS marked including all accessories (like SS Pipes, SS Chain (Shackle Chain) ,SS Foundation Bolt, complete base frame, Monorail, Chain Guide Pipe, Auto Compiling, Duct Foot Bend (D/F Bend) etc. complete in all respect. Discharge Capacity (LPM) – 8000
Supply, erection, testing and commissioning of LT cables PVC insulated single core 1100 VER copper conductor confirming to BS 6004-1984 including cost of thimbles, lugs for making connection underground covered with sand and bricks/In trench/in pipe on steel bridges (Detail of cable sizes and length to be provided be clearly mentioned for making following connection. 10sq mm single core electric copper wire from electric meter to 15 Nos. Street lights at 18 MLD STP of Bahadurgarh Town
Providing and fixing of LED Street light of 100 W of reputed make with all accessories.
Credit for old Mechanical Coarse screen at MPS. Total weight of Coarse Screen = 500 Kg. Rate of Scrap = 120/- Kg Total cost = 500 x 120 = 60000/-
Credit for old Mechanical Fine screen at MPS. Total weight of Fine Screen = 200 Kg. Rate of Scrap = 120/- Kg Total cost = 200 x 120 = 24000/-
Providing HDPE Pipe of 90 mm o/d including freight, loading, unloading charges..
Supply, installation, Clamping of GLSS Sheets 396 sqm each in three UASB reactors. (Excluding Hydra Charges)
Hydra Charges for Installation, fixing of broken FRP, GLSS Sheets in UASB reactors.
Providing and Installation of EOT crane with 2 tonne capacity and with single girder and 2 HP Motor
Providing and Installation of Gate Valves
Providing and Installation of IR Pumps 750m3/H @ 12 MWC
Providing and Installation of SS 304 Sludge Scrapper and MS Scrapping bridge with MS rail 10 mm thick and Related Mechanical and Civil Works (Installation of DI pipe of 450 mm or more dia pipe from Aeration Tank Launder to Secondary clarifier is included
Providing and Installation of Disc filters including all inlet outlet pipes, valves, specials, backwash arrangement and piping . Filters must be covered with shed of specification as per tender document..
Providing and Installation of SS 304 Pipe of 100 mm from Biogas Baloon to Flare System
Providing and Installation of Biogas Holder with 18 m diameter, working pressure 3-5 m bar. with 1. anchoring system including flat SS 304 profile, SS -304 Anchors, sealant, protection foil, Air Hose, Compressed air connection set 2. Supporting system Including 3. Blower set with bracket and surround with supply air duct of SS 4. Over and under pressure relief valves 5. 18 m Diameter Double membrane balloon 1100 GSM 6. Installation and Commissioning of ground mounted Double membrane balloon
Providing and Installation of Surplus Sludge pumps (2W plus 1S) 300m3/H
Cutting Jointing, clamping and Removal of HDPE pipes from inside the UASB reactors and Clamping of HDPE pipes with S.S Nuts above 6 inch over the UASB reactor bed
Providing and Installation of Dissolved Oxygen Meter with 2 probes
Providing and Installation of Level Sensors/ controllers (0 to 7.5 M)
Providing and installation of Control Panel for 8000 LPM having head 12.00 pumping set non clog for sewerage.
Providing and Installation of Control Panels for RAS Pumps 190m3/H @ 12 MWC (2W plus 2S)
Providing and Installation of Control Panels for Surplus Sludge pumps (2W plus 1S) 300m3/H
Providing and Installation of Control Panels for IR Pumps 750m3/H @ 12 MWC (2W plus 2S)
Providing and Installation of wall mounted Anoxic Mixers (5 HP Each)
Providing and Installation of Control Panels for wall mounted Anoxic Mixers in Both Anoxic tanks (5 HP Each)
Providing and Installation of Control Panels for twin Lobe Blowers of Capacity 2700 m3/H @ 0.5 kgf/cm2 ( 2W plus 2S)
Providing and Installation of Control Panels for Secondary Clarifier.
Providing and installation of Cables for required length and Sizes.
Providing and Installation of SS-316 (As per design) Aeration Grid in Both Tanks along with diffusers of size 900 mm x 90 mm with silicon laser cut membrane SS-304 clamps on both and capacity 8 - 10 m3/H air flow rate.
Providing and Installation of Split Air Conditioners of 2.00 Ton Capacity of reputed make like O General, Hitachi and Carrier etc.
Providing and Installing Computers (Intel Core i7 Quad-core processor (Intel 11th Generation Core i7 or newer, minimum 2.3 gigahertz).
Providing and Installing All in one Printer of reputed make like HP, Canon, Epson etc.
Providing and Installation of 265 L Frost Free Double Door Refrigerator of reputed make like, Whirlpool, Samsung, Godrej, Kelvinator etc.
Providing and fixing of 450 mm Electromagnetic Flow meter of reputed make like Endress Haider, Honeywell, Himag -100, Hydrocontrols
Providing and fixing of 700 mm Electromagnetic Flow meter of reputed make like Endress Haider, Honeywell, Himag -100, Hydrocontrols
Supply and installation of UPVC support angles for GLSS Sheet clamping with UPVC Nuts as per existing design.
Repair of Existing Gate Valves
Repair of Existing Gate Valves.
Providing and installation of Control Panel for 8000 LPM having head 18.00 pumping set non clog for sewerage..
Supply and Installation of twin Lobe Blowers of Capacity 2700 m3/H @ 0.5 kgf/cm2 ( 2W plus 2S) with Acoustic Casing (Make: Kay / Everest / Swam/ Kirloskar pneumatic Co./K..G. khosla Compressors Ltd/Ingersoll Rand/Chicago Pneumatic/Spencer (I)Ltd./Elgi) (As per design).
Providing and Installation of Centrifuge machines of 500 Kg/H including Poly Elecrolyte dosing pumps in Centrifuge Building, 700 LPH as per desired specification.
Chlorination System with chlorine leak detectors with dual sensors and all emergency equipments as per desired specification.
Providing and Installation of Auto Ignition Gas Flaring System, atleast at height of 5 m as per desired specifications.
Providing and Installation and Laying of SS-304 Pipe of 100 mm from UASB gas header pipe to Bio Gas Balloon after 3 reactors as per desired specifications.
Providing Lab Equipments and Chemicals, BOD Incubator, COD Digestor, Oven, Auto clave as per desired specifications. COD DIGESTION APPARATUS, DIGITAL pH METER, SPECTRO HOTOMETER,TURBIDITY/NEPHELOMETERS, B. O.D Incubator (LOW TEMPERATURE) DIGITAL MODEL COOLING SYSTEM, DIGIAL BALANCE, MUFFLE FURNACE RECTANGULAR, DO METER, DEEP FREEZER, MAGNETIC STIRRER, BACTERIOLOGICAL ORBITAL SHAKING Incubator, DISTILLATION APPARATUS ALL GLASS (ELECTRICALLY HEATED), BIOLOGICAL SAFETY CABINET/SAMPLING BOOTH, FUME HOOD, AUTOCLAVE VERTICA and ALL REQUIRED GLASSWARE and Chemicals
Providing and Installation of 5 CCTV Outdoor Camera including 1 No. of 360 Degree, DVR having storage capacity of 2 TB and 1 No. 32` LED Screen supporting 8 cameras at 18 MLD STP of Bahadurgarh and connecting of Camera and flow meter to HSPCB and Head office with dedicated Internet connection, transfer of data through modem including all accessories.
HT/LT Panel 11 KV HT Panel Board with 1 incomer VCB 11 KV and 2 Outgoing VCB 11 KW, 630A 21KA RMS with CT / PT transformers, GO switches and all accessories including Cables of required sizes and Panel Enclosure make: Rittal , Pyrotech , Schneider , president, Cuttler Hammer, Crompton as per desired specifications.
Operation and Maintenance for complete scope of work covered under this contract as per OandM schedule for a period of 5 year after successful completion of 12 month`s defect liability period and 3 Months trial run complete in all respect as per approved NIT. The amount will be charged to the A/Mtc. estimate. Operation during defect liability period: Operation after successful completion of 3 month trial run period for complete scope of work covered under this contract complete in all respect as per as per OandM schedule and approved DNIT. The amount will be charged to the A/Mtc. estimate
OandM during 1st. year: Operation and maintenance for complete scope of work covered under this contract complete in all respect as per as per OandM schedule and approved DNIT. The amount will be charged to the A/Mtc. estimate.
OandM during 2nd. year: Operation and Maintenance for complete scope of work covered under this contract complete in all respect as per as per OandM schedule and approved DNIT. The amount will be charged to the A/Mtc. estimate.
OandM during 3rd. year: Operation and Maintenance for complete scope of work covered under this contract complete in all respect as per as per OandM schedule and approved DNIT. The amount will be charged to the A/Mtc. estimate.
OandM during 4th. year: Operation and Maintenance for complete scope of work covered under this contract complete in all respect as per as per OandM schedule and approved DNIT. The amount will be charged to the A/Mtc. estimate.
OandM during 5th. year: Operation and Maintenance for complete scope of work covered under this contract complete in all respect as per as per OandM schedule and approved DNIT. The amount will be charged to the A/Mtc. estimate.
Anil Kumar Contractor (BID ID -1203336)
Anil Kumar Contractor (BID ID -1203336)
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid