Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹81.1 LAccepted-AOC PLOT NO 112 SHAILI GARDENIA YAPRAL RANGAREDDI TELANGANA 500087 | MEDCHAL MALKAJGIRI | TELANGANA | 500087 | L1 | Accepted-AOC Accepted | |
| 2 | L2₹88.8 L+₹7.7 L (9.47%)Rejected-Finance PRAGATHI PRIDE APARTMENT 3 4 520 FLAT NO 203 BARKATPURA HYDERABAD 500 027 | HYDERABAD | TELANGANA | 500027 | L2 | Rejected-Finance rejected | |
| 3 | L3₹89.4 L+₹8.3 L (10.2%)Rejected-Finance 1 3 183 40 46 PLOT NO 36 VAIKUNTHA SAI NAGAR NEW BAKARAM GANDHI NAGAR HYDERABAD TELANGANA 500080 | HYDERABAD | TELANGANA | 500080 | L3 | Rejected-Finance Rejected | |
| 4 | L4₹89.9 L+₹8.8 L (10.9%)Rejected-Finance | L4 | Rejected-Finance Rejected | |
| 5 | L5₹98.2 L+₹17.0 L (21.0%)Rejected-Finance 61 DANDA KHUDANEWALA NEAR GAS GODAM SAHASTRADHARA ROAD DEHRADUN 248001 | DEHRADUN | UTTARAKHAND | 248001 | L5 | Rejected-Finance Rejected |
Tender Value
₹1.0 Cr
EMD Value
₹2.0 L
Closing Date
7 Nov 2022, 3:00 pmClosed
CCE R and D South
P.B NO 1569 AKBAR ROAD SECUNDERABAD 500003
Operation and Maintenance of ENM Installations for Internal N External Electrification DG Sets EOT AND Mono Rail Cranes Air conditioning system Fire alarm system Fighting system Water supply EPABX System Water coolers with RO and Area Liem F
2022_DRDO_718618_1
83648/ONM/FCS/CON
Limited
Support/Maintenance Service
Item Rate
330 days
FCS INTEGRATION FACILITY BENGALURU
as per nit
2 documents required · 2 mandatory
₹1,000
Yes
CCE R and D South Secunderabad
₹2.0 L
Yes
31 Jan 2023
18 Oct 2022
9 Nov 2022
18 Oct 2022
7 Nov 2022
31 Oct 2022
Amount
Operation and Maintenance of E&M Installations for Internal & External Electrification, DG Sets, EOT & MONO Rail Cranes, Air- Conditioning System, Fire Alaram System. Fire Fighting System, Water Supply, EPABX System, Water Coolers witj RO, and Area Lighting for FCS Integration Facility at ADE, Bengaluruas per mentioned in Anexure-II to VII by deploying manpower on all days including Sundays and Holidays.
a) Internal and External electrifications.
b) Inter and External Water Suuply.
c) DG Sets
d) Lighting Protection
e) Fire Fighting system
F)Fir alaram system
g) Air-conditioning System
h) RO Plant
i) EPBAX System
"B" check for 750 KVA DG set
Load testing of 2 Ton Capacity EOT cranes ( The cost shall be inclusive of test loads,slings, D shakles etc, transportation to site and back, and cost of certifacation carried out by State Government Inspetor of Factories) nothing extra shall be paid.
Over Time for Skiled Labour
Over Time for Un Skiled Labour
CONSUMBLES:
Transporation of Diesel
Replacement of 1 set (4 Nos) of Pre filters for water coolers
Lighting Fixtures
12 Watt Recessed LED Downlighter with minimum luminaire system efficacy of 100 lm/w having a color temperature of 5700K and housing should made up of pressure die cast aluminium with high efficiency diffuser with driver, accessories wiring etc. Model No.PDLM26128
20 Watt Surface mounted LED Downlighter with minimum luminaire system efficacy of 100 lm/w having a color temperature of 5700K and housing should made up of powder coated CRCA with high eff. Model No.PDLM10206
20 Watt Recessed LED Downlighter with minimum luminaire system efficacy of 100 lm/w having a color temperature of 5700K and housing should made up of pressure die cast aluminium with high efficiency diffuser with driver, accessories wiring etc. Model No.PDLM26208
20W,2000 lumens T8,1200mm length LED retrofit tube light with aluminium anodised body, input voltage AC 220 - 260 Volts with PF>0.9, Surge protection: 2KV,THD<10%, with inbuilt driver and frosted cover CCT: 3000K - 5700K, minimum CRI>70, .etc., complete as per IS 10322. Model No.PBTM17228
IP65 20W,2000 lumens T8,1200mm length LED retrofit tube light with aluminium anodised body, input voltage AC 220 - 260 Volts with PF>0.9, Surge protection: 2KV,THD<10%, with inbuilt driver and frosted cover CCT: 3000K - 5700K, minimum CRI>70, .etc., complete as per IS 10322. Model No.PBTM19208
100 Watt Recessed LED 2 x 2 panel High bay Fitting with minimum luminaire system efficacy of 100 lm/w having a color temperature of 5700K and housing should made up of powder coated CRCA with high efficiency diffuser with driver, accessories wiring etc. Model No.PCNM02AB8,
36 Watt Recessed LED 2 x 2 panel with minimum luminaire system efficacy of 100 lm/w having a color temperature of 5700K and housing should made up of powder coated CRCA with high efficiency diffuser with driver, accessories wiring etc. Model No.PBLM22368
10 Watt Bulkhead LED light fixture with minimum luminaire system efficacy of 70 lm/w having a color temperature of 5700K and housing should made up of pressure die cast aluminium with high efficiency diffuser with driver, accessories wiring etc Model No.PBHM01107
14 Watt Decorative Mirror Light LED light fixture with minimum luminaire system efficacy of 70 lm/w having a color temperature of 5700K and housing should made up of pressure die cast aluminium with high efficiency diffuser with driver, accessories wiring etc Model No.58157 AQUILA 15W LED WALL LIGHT (PHILIPS)
CHARAN ELECTRICALS
HYDRO PNEUMATIC ENGINEERS HYD PVT LTD
Shri Sai Enterprises
M/s New Weather
SATYAM ELECTRICALS
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .